0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
TL-11683

TL-11683

  • 厂商:

    HONEYWELL(霍尼韦尔)

  • 封装:

    -

  • 描述:

    HEX NUT 15/32 TL SERIES

  • 数据手册
  • 价格&库存
TL-11683 数据手册
MICRO SWITCH Military-Grade Toggle Switches TL Series 005430 Issue 4 Datasheet FEATURES • • • • • • • MIL-DTL-3950 qualified 1-, 2-, and 4-pole options 2- and 3-position, maintained and momentary Wide temperature range: -65 °C to 71 °C [-85 °F to 160 °F] UL recognized, CSA certified, and CE approved Optional leverlocks Three termination options: screw, solder lugs, IWTS (Integrated Wire Termination System) • Silver alloy or gold-plated contact options • Engineered step-design case provides added space between terminals to prevent electrical shorting DESCRIPTION POTENTIAL APPLICATIONS Honeywell MICRO SWITCH TL Series toggle switches are military qualified to MIL-DTL-3950, specifications for sealed toggle switches. Quality construction features include a bonded seal between the toggle lever and bushing, and between the cover and case. • Miliitary and commercial aircraft: fixed wing aircraft and helicopter flight decks • Aviation ground support equipment: pumps, lights, and lift platforms • Military land vehicles (track and wheeled vehicles): lights, pumps, arming equipment, and lifts/ramps, etc. • Construction equipment: road milling, road pavers, trenchers, and stump cutters The robust design of the TL Series toggle is well-suited for many military, aerospace and other demanding applications where reliability is essential. These applications include environments where the panels are subjected to mechanical shock, vibration, and temperature extremes as well as environments with dust, splashing or hose-directed water. TL Series toggle switches offer a variety of circuitry and pole options to easily integrate into a number of applications. A long history in military and aerospace applications has shown the TL Series toggle switches provide reliable performance with long operating life under the toughest conditions. VALUE TO CUSTOMERS • MIL-DTL-3950 qualified switches available to meet military specifications • Environmental sealing enables switches to withstand many demanding indoor and outdoor applications • 1-, 2-, and 4-pole options for a variety of circuitry requirements • 2- and 3-position, maintained and momentary toggle action to meet circuit and actuator requirements • UL recognized, CSA certified, and CE approved for global use Sensing and Internet of Things DIFFERENTIATION • Robust construction: Built from military-grade components to achieve MIL-DTL-3950 requirements • Locking levers reduce unintended actuation PORTFOLIO Honeywell offers an extensive line of MICRO SWITCH toggle switches, including the following Series: MT, NT, TW, TS, AT, and ET. MICRO SWITCH Military-Grade Toggle Switches, TL Series Table 1. Specifications Characteristic Parameter Description military-grade toggle switch Sealing qualified to MIL-DTL-3950 Operating temperature -65 °C to 71 °C [-85 °F to 160 °F] Actuators standard, locking, special design, tab Action 2- or 3- position; momentary and maintained Mounting Bushing 15/32 in (0.47 in) Ø Circuitry SPST, SPDT, DPST, DPDT, 4PST, 4PDT Terminations IWTS, solder, screw, quick-connect, leadwire Contacts Silver alloy or gold-plated Amp rating Up to 20 A, ac and dc capability Approvals UL, CSA, CE Measurement 26,7 mm H x 33,5 mm W x 22,6 mm D [1.05 in H x 1.32 in W x 0.89 in D] Table 2. UL and CSA Electrical Ratings Rating Code Electrical Rating L192 10 amps, 125, 250, 277 Vac; ¼ Hp, 125 Vac; ½ Hp, 250, 277 Vac; 3 amps, 125 Vac “L” L191 15 amps, 125, 250, 277 Vac; ½ Hp, 125 Vac; 1 Hp, 250, 277 Vac; 5 amps, 125 Vac “L” Table 3. Electrical Ratings (in amperes) Electrical rating code 28 Vdc 115 Vdc 250 Vdc 115 Vac, 60 Hz & 400 Hz Max. 230 Vac Ind. Res. Lamp Res. Res. Ind. Res. Lamp Res. 1 15 20 5 0.75 0.5 10 15 3 6 2 10 15 4 0.75 0.5 7 15 2 6 3 15 20 7 0.75 0.5 15 15 4 6 4 10 18 5 0.75 0.5 8 11 2 6 5 12 20 5 0.75 0.5 15 15 4 6 6 10 18 4 0.75 0.5 8 11 2 6 2 sensing.honeywell.com MICRO SWITCH Military-Grade Toggle Switches, TL Series TERMINAL CIRCUIT IDENTIFICATION SPECIAL CIRCUITRIES Terminal identifications are referred to in the order guides to indicate which circuits are made in each toggle position (i.e., 1-2 refers to circuit closure through terminals 1 and 2). Catalog listings with -10, -50, and -70 suffix numbers, as shown in the order guides, have special “on-on-on” circuits, as illustrated below. TLs with -12 suffix are the same as -50 except the keyway position is maintained. The -72 is the same as -50 except that the opposite keyway position is momentary. One Pole -10 CIRCUITRY No of poles Two Pole Keyway Side Maint. Position Center Maint. Position Opposite Keyway Maint. Position Center Maint. Position Opposite Keyway Maint. Position Center Maint. Position Opposite Keyway Momentary Position 2 4 Four Pole -50 CIRCUITRY No of poles TERMINALS In addition to the screw terminal listings in the order guides, IWTS (Integrated Wire Termination Systems) versions and solder turrent terminals are available. IWTS provides a reliable, completely serviceable unit which meets MIL-DTL-3950 requirements. IWTS improves maintainability since wiring bundles need not be disturbed. Leads are quickly and easily assembled or removed with an insert-extract tool. A unique three-rib (grommet style) elastomer seal protects the lead connections without potting. There are no exposed metal terminals. Versions available that will accept No. 16 wire with M39029/1102 contact pins or No. 20 wire with MS39029/1-101 contact pins. Connections are resistant to shock, vibration, and high pull-out force. Keyway Side Momentary Position 2 4 -70 CIRCUITRY No of poles Keyway Side Momentary Position 2 4 Sensing and Internet of Things 3 MICRO SWITCH Military-Grade Toggle Switches, TL Series TL (SCREW TERMINAL) 2-POSITION ORDER GUIDE Circuits Made with Toggle At: No. of poles 1 2 4 Keyway Position Standard Toggle Opposite Keyway Elect. Rating Code UL Rating Code Catalog Listing Military Number Pull-to-Unlock Toggle Add Suffix to Standard Toggle Listing D Military Number** OFF 2-3 1 L191 1TL1-2 MS24523-22 D, F, G MS24658-22 OFF* 2-3 2 L192 1TL1-4 MS24523-29 F MS24658-29 1-2* OFF 2 L192 1TL1-6 MS24523-30 F MS24658-30 1-2 2-3 1 L191 1TL1-3 MS24523-23 D, F, G MS24658-23 1-2* 2-3 2 L192 1TL1-8 MS24523-26 F MS24658-26 OFF 2-3, 5-6 3 L191 2TL1-2 MS24524-22 D, F, G MS24659-22 OFF* 2-3, 5-6 4 L192 2TL1-4 MS24524-29 F MS24659-29 1-2, 4-5* OFF 4 L192 2TL1-6 MS24524-30 F MS24659-30 1-2, 4-5 2-3, 5-6 3 L191 2TL1-3 MS24524-23 D, F, G MS24659-23 1-2, 4-5* 2-3, 5-6 4 L192 2TL1-8 MS24524-26 F MS24659-26 OFF 2-3, 5-6, 8-9, 11-12 5 L191 4TL1-2 MS24525-22 D, F, G MS24660-22 OFF* 2-3, 5-6, 8-9, 11-12 6 L192 4TL1-4 MS24525-29 F MS24660-29 1-2, 4-5, 7-8, 1011* OFF 6 L192 4TL1-6 MS24525-30 F MS24660-30 1-2, 4-5, 7-8, 10-11 2-3, 5-6, 8-9, 11-12 5 L191 4TL1-3 MS24525-23 D, F, G MS24660-23 1-2, 4-5*, 7-8, 10-11 2-3, 5-6, 8-9, 11-12 6 L192 4TL1-8 MS24525-26 F MS24660-26 * These positions are momentary. All others are maintained. ** Also add the appropriate suffix to the military number. D See page 10 for locking configurations. PULL-TO-UNLOCK OPTION When ordering pull-to-unlock toggle listings (see page 12 for configurations), add the suffix letter shown in the chart on page XXX to the standard toggle listing or the MS part number. For example, to order a 1TL1-1 pull-to-unlock toggle switch with the lever locked in the center position, add the letter E (i.e., 1TL1-1E, MS24658-21E) SOLDER TURRET TERMINAL VERSION 11TL, 12TL, and 14TL type switches with solder turrent terminals are qualified to MIL-DTL-3950. They have the same circuitry and electrical ratings as their 1TL, 2TL, and 4TL counterparts, For example, an 11TL1-2 is the same as a 1TL1-2, except it has solder turret terminals instead of screw terminals. Type Standard Lever Lever Lock One pole Circuitry 11TL MS27734 MS27737 Two pole 12TL MS27735 MS27738 Four pole 14TL MS27736 MS27739 4 sensing.honeywell.com MICRO SWITCH Military-Grade Toggle Switches, TL Series TL (SCREW TERMINAL) 3-POSITION ORDER GUIDE Circuits Made with Toggle At: 2 4 UL/CSA Rating Code 1 Pull-to-Unlock Toggle Elect. Rating Code No. of poles Standard Toggle Catalog Listing 1-2 OFF 2-3 1 L191 1TL1-1 MS24523-21 ALL TYPES MS24658-21 1-2* OFF 2-3 2 L192 1TL1-5 MS24523-31 E, F, K, L, M, N MS24658-31 1-2* OFF 2-3* 2 L192 1TL1-7 MS24523-27 E, L, N MS24658-27 NONE** OFF 2-3 1 L191 1TL1-21 MS24523-24 E, F, K, M MS24658-24 NONE** 1-2 2-3 1 L192 1TL1-31 MS24523-33 E, F, K, M MS24658-33 NONE** 1-2 2-3* 2 L192 1TL1-51 MS24523-32 E MS24658-32 1-2* OFF NONE** 2 L192 1TL1-61 MS24523-28 E MS24658-28 1-2, 4-5 OFF 2-3, 5-6 3 L191 2TL1-1 MS24524-21 ALL TYPES MS24659-21 1-2, 4-5* OFF 2-3, 5-6 4 L192 2TL1-5 MS24524-31 E, F, K, L, M, N MS24659-31 1-2, 4-5* OFF 2-3, 5-6* 4 L192 2TL1-7 MS24524-27 E, L, N MS24659-27 NONE** OFF 2-3, 5-6 3 L191 2TL1-21 MS24524-24 E, F, K, M MS24659-24 NONE** 1-2, 4-5 2-3, 5-6 3 L191 2TL1-31 MS24524-33 E, F, K, M MS24659-33 NONE** 1-2, 4-5 2-3, 5-6* 4 L192 2TL1-51 MS24524-32 E MS24659-32 1-2, 4-5* OFF NONE** 4 L192 2TL1-61 MS24524-28 E MS24659-28 1-2, 4-5 1-2, 5-6 2-3, 5-6 3 L191 2TL1-10 MS27407-4 ALL TYPES MS27408-4 1-2, 4-5* 1-2, 5-6 2-3, 5-6 4 L192 2TL1-50 MS27407-5 E, F, K, L, M, N MS27408-5 1-2, 4-5* 1-2, 5-6 2-3, 5-6* 4 L192 2TL1-70 MS27407-6 E, L, N MS27408-6 1-2, 4-5, 7-8, 10-11 OFF 2-3, 5-6, 8-9, 11-12 5 L191 4TL1-1 MS24525-21 ALL TYPES MS24660-21 1-2, 4-5, 7-8, 10-11* OFF 2-3, 5-6, 8-9, 11-12 6 L192 4TL1-5 MS24525-31 E, F, K, L, M, N MS24660-31 1-2, 4-5, 7-8, 10-11* OFF 2-3, 5-6, 8-9, 11-12* 6 L192 4TL1-7 MS24525-27 E, L, N MS24660-27 NONE** OFF 2-3, 5-6, 8-9, 11-12 5 L191 4TL1-21 MS24525-24 E, F, K, M MS24660-24 NONE** 1-2, 4-5, 7-8, 10-11 2-3, 5-6, 8-9, 11-12 5 L191 4TL1-31 MS24525-33 E, F, K, M MS24660-33 NONE** 1-2, 4-5, 7-8, 10-11 2-3, 5-6, 8-9, 11-12* 6 L192 4TL1-51 MS24525-32 E MS24660-32 1-2, 4-5, 7-8, 10-11* OFF NONE** 6 L192 4TL1-61 MS24525-38 E MS24660-28 1-2, 4-5, 7-8, 10-11 2-3, 4-5 2-3, 5-6, 8-9, 11-12 5 L191 4TL1-10 – ALL TYPES – 1-2, 4-5, 7-8, 10-11* 2-3, 4-5, 7-8, 11-12 2-3, 5-6, 8-9, 11-12 6 L192 4TL1-50 MS27406-2 E, F, K, L, M, N MS27409-2 1-2, 4-5, 7-8, 10-11* 2-3, 4-5 2-3, 5-6, 8-9, 11-12* 6 L192 4TL1-70 – E, L, N – 1-2, 4-5, 7-8, 10-11 2-3, 4-5, 7-8, 11-12 2-3, 5-6, 8-9, 11-12 5 L191 4TL1-12 MS27406-1 ALL TYPES MS27409-1 1-2, 4-5, 7-8, 10-11* 2-3, 4-5, 7-8, 11-12 2-3, 5-6, 8-9, 11-12* 6 L192 4TL1-72 MS27406-3 E, L, N MS27409-3 Keyway Position Center Position Opposite Keyway Military Number Add Suffix to Standard Toggle Listing D Military Number*** * These positions are momentary. All others are maintained. ** Toggle lever is blocked from these products. Toggle becomes 2-position, with center being one extreme position. *** Also add appropriate suffix letter to military number D See page 10 for locking configurations. Sensing and Internet of Things 5 MICRO SWITCH Military-Grade Toggle Switches, TL Series TL (IWTS TERMINATION) 2-POSITION ORDER GUIDE Circuits Made with Toggle At: No. of poles 1 2 4 Keyway Position Opposite Keyway No. 16 Termination Elect. Rating Code UL Rating Code Catalog Listing Military Number No. 20 Termination Catalog Listing Military Number OFF 2-3 1 L191 101TL1-2 MS27722-22 101TL2-2 MS27784-22 OFF* 2-3 2 L192 101TL1-4 MS27722-29 101TL2-4 MS27784-29 1-2* OFF 2 L192 101TL1-6 MS27722-30 101TL2-6 MS27784-30 1-2 2-3 1 L191 101TL1-3 MS27722-23 101TL2-3 MS27784-23 1-2* 2-3 2 L192 101TL1-8 MS27722-26 101TL2-8 MS27784-26 OFF 2-3, 5-6 3 L191 102TL1-2 MS27723-22 102TL2-2 MS27785-22 OFF* 2-3, 5-6 4 L192 102TL1-4 MS27723-29 102TL2-4 MS27785-29 1-2, 4-5* OFF 4 L192 102TL1-6 MS27723-30 102TL2-6 MS27785-30 1-2, 4-5 2-3, 5-6 3 L191 102TL1-3 MS27723-23 102TL2-3 MS27785-23 1-2, 4-5* 2-3, 5-6 4 L192 102TL1-8 MS27723-26 102TL2-8 MS27785-26 OFF 2-3, 5-6, 8-9, 11-12 5 L191 104TL1-2 MS27724-22 104TL2-2 MS27786-22 OFF* 2-3, 5-6, 8-9, 11-12 6 L192 104TL1-4 MS27724-29 104TL2-4 MS27786-29 1-2, 4-5, 7-8, 10-11* OFF 6 L192 104TL1-6 MS27724-30 104TL2-6 MS27786-30 1-2, 4-5, 7-8, 10-11 2-3, 5-6, 8-9, 11-12 5 L191 104TL1-3 MS27724-23 104TL2-3 MS27786-23 1-2, 4-5, 7-8, 10-11* 2-3, 5-6, 8-9, 11-12 6 L192 104TL1-8 MS27724-26 104TL2-8 MS27786-26 TL (IWTS TERMINATION) 3-POSITION ORDER GUIDE Circuits Made with Toggle At: 2 4 UL/CSA Rating Code 1 No. 20 Termination Elect. Rating Code No. of poles No. 16 Termination Catalog Listing 1-2 OFF 2-3 1 L191 101TL1-1 MS27722-21 101TL2-1 MS27784-21 1-2* OFF 2-3 2 L192 101TL1-5 MS27722-31 101TL2-5 MS27784-31 1-2* OFF 2-3* 2 L192 101TL1-7 MS27722-27 101TL2-7 MS27784-27 1-2, 4-5 OFF 2-3, 5-6 3 L191 102TL1-1 MS27723-21 102TL2-1 MS27785-21 1-2, 4-5* OFF 2-3, 5-6 4 L192 102TL1-5 MS27723-31 102TL2-5 MS27785-31 1-2, 4-5* OFF 2-3, 5-6* 4 L192 102TL1-7 MS27723-6 102TL2-7 MS27785-27 1-2, 4-5, 7-8, 10-11 Keyway Position Center Position Opposite Keyway Military Number Catalog Listing Military Number OFF 2-3, 5-6, 8-9, 11-12 5 L191 104TL1-1 MS27724-21 104TL2-1 MS27786-21 1-2, 4-5, 7-8, 10-11* OFF 2-3, 5-6, 8-9, 11-12 6 L192 104TL1-5 MS27724-31 104TL2-5 MS27786-31 1-2, 4-5, 7-8, 10-11* OFF 2-3, 5-6, 8-9, 11-12* 6 L192 104TL1-7 MS27724-27 104TL2-7 MS27786-27 * These positions are momentary. All others are maintained. NOTE: For TL switches featuring IWTS termination and a “pull-to-unlock” lever option, contact a Honeywell Sensing and Control representative at 1-800-537-6945. 6 sensing.honeywell.com MICRO SWITCH Military-Grade Toggle Switches, TL Series TL SERIES 1-POLE STANDARD ACTUATOR OPTIONS, TERMINALS, & DIMENSIONS Note: Three-position switches shown 1TL1: Single pole, standard lever, screw terminals 11TL1: Single pole, standard lever, solder terminals 1,93 mm ±0,20 mm wide keyway [0.076 in ±0.008 wide keyway] 101TL1: Single pole, standard lever, IWTS terminals 1,93 mm ±0,20 mm wide keyway [0.076 in ±0.008 wide keyway] 1,93 mm ±0,20 mm wide keyway [0.076 in ±0.008 wide keyway] 10,9 mm [0.43 in] 10,9 mm [0.43 in] 10,9 mm [0.43 in] 31° ±7° total travel 31° ±7° total travel 31° ±7° total travel 15° 30’ ±3° 30’ Ø 6,09 mm [Ø 0.24 in] 15° 30’ ±3° 30’ 15° 30’ ±3° 30’ Ø 6,09 mm [Ø 0.24 in] Ø 6,09 mm [Ø 0.24 in] 17,0 mm [0.67 in] 15/32 - 32 UNS 2A thread to within 1,52 mm [0.060 in] of shoulder 17,0 mm [0.67 in] 11,9 mm [0.47 in] 29,5 mm [1.16 in] 15/32 - 32 UNS 2A thread to within 1,52 mm [0.060 in] of shoulder 6,1 mm [0.24 in] 23,1 mm [0.91 in] Sealed to prevent entrance of liquids or dust 11,9 mm [0.47 in] 29,5 mm [1.16 in] 6,1 mm [0.24 in] Sealed to prevent entrance of liquids or dust 23,1 mm [0.91 in] 4,7 mm ± 0,38 mm [0.185 in ±0.015 in] (3) 6,4 mm [0.25 in] 17,0 mm [0.67 in] 11,9 mm [0.47 in] 15/32 - 32 UNS-2 thread to within 1,52 mm [0.060 in] of shoulder 6,1 mm [0.24 in] Sealed to prevent entrance of liquids or dust 36,07 mm [1.42 in] 4,57 mm dia [0.18 in dia] (3) 2,29 mm dia [0.09 in dia] (3) 28,4 mm [1.12 in] 28,4 mm [1.12 in] 4,8 mm [0.19 in] 19,05 mm [0.75 in] 4,8 mm [0.19 in] 9,7 mm [0.38 in] 3X 6-32 UNC-2A X (0.260) binding head terminal screw and lockwasher (sems) 15,7 mm [0.62 in] 28,7 mm ±0,76 mm [1.130 ±0.030 in] 19,05 mm [0.75 in] 9,7 mm [0.38 in] 28,4 mm [1.12 in] 15,7 mm [0.62 in] 9,7 mm [0.38 in] 15,7 mm [0.62 in] 9,7 mm [0.38 in] Sealed construction (blue seal) Locking lever dimensions for single pole TL toggles 31° ±7° total travel 15° ±3° Ø 10,67 mm [Ø 0.42 in] 2,28 mm [0.090 in] 26,67 mm approx. pullout [1.05 in] to change position Sensing and Internet of Things 7 MICRO SWITCH Military-Grade Toggle Switches, TL Series TL SERIES 2-POLE STANDARD ACTUATOR OPTIONS, TERMINALS, & DIMENSIONS Note: Three-position switches shown 2TL1: Single pole, standard lever, screw terminals 12TL1: Single pole, standard lever, solder terminals Ø 6,09 mm [Ø 0.24 in] Ø 6,09 mm [Ø 0.24 in] 10,9 mm [0.43 in] 10,9 mm [0.43 in] 17° ±4° 17° ±4° Ø 6,09 mm [Ø 0.24 in] 15/32 - 32 UNS 2A thread to within 1,52 mm [0.060 in] of shoulder 3,3 mm min. [0.130 in min.] Sealed to prevent entrance of liquids or dust 3,05 mm 17,0 mm [0.67 in] [0.12 in] 15/32 - 32 UNS-2 thread to within 1,52 mm [0.060 in] of shoulder 11,9 mm [0.47 in] 6,09 mm [0.24 in] Sealed to prevent entrance of liquids or dust 4,57 mm dia [0.18 in dia] (6) 27,94 mm 3,3 mm min. 34,29 mm [1.10 in] [0.130 in min.] [1.35 in] 0,76 mm [0.03 in] (6) 3,3 mm min. [0.130 in min.] 1 Sealed construction (blue seal) Terminals accept PIN M39029/1-102 4 6 8 sensing.honeywell.com 9,7 mm [0.38 in] 5 2,28 mm [0.090 in] 26,67 mm approx. pullout [1.05 in] to change position 2 Ø 10,67 mm [Ø 0.42 in] 3 17° ±4° 22,6 mm [0.89 in] 9,7 mm [0.38 in] 4 34° ±8° total travel 1 Locking lever dimensions for double pole TL toggles 9,7 mm [0.38 in] 5 6X 6-32 UNC-2A x (0.260) binding head terminal screw and lockwsher (sems) 9,7 mm [0.38 in] 23,1 mm max. [0.91 in max] 33,53 mm [1.320 in] 9,7 mm [0.38 in] 9,7 mm [0.38 in] 6 6,6 mm [0.26 in] 19,05 mm [0.75 in] 15/32 - 32 UNS-2 thread to within 1,52 mm [0.060 in] of shoulder 37,34 mm max [1.47 in max.] 2 9,7 mm [0.38 in] Sealed to prevent entrance of liquids or dust 6,09 mm [0.24 in] 19,05 mm [0.75 in] 6,6 mm [0.26 in] 3 7,1 mm [0.28 in] 11,9 mm [0.47 in] 3,05 mm [0.12 in] 34,0 mm max. [1.34 in max.] 7,1 mm [0.28 in] 33,53 mm [1.32 in] 17,0 mm [0.67 in] 4,83 mm dia [0.19 in dia] (6) 2,29 mm dia [0.09 in dia] (6) 3,3 mm min. [0.130 in min.] 22,6 mm [0.89 in] 34° ±8° total travel 17° ±4° 11,9 mm [0.47 in] 6,1 mm [0.24 in] 34,29 mm [1.35 in] 10,9 mm [0.43 in] 34° ±8° total travel 34° ±8° total travel 27,94 mm [1.10 in] 1,93 mm ±0,20 mm wide keyway [0.076 in ±0.008 wide keyway] 1,93 mm ±0,20 mm wide keyway [0.076 in ±0.008 wide keyway] 1,93 mm ±0,20 mm wide keyway [0.076 in ±0.008 wide keyway] 17,0 mm [0.67 in] 102TL1: Single pole, standard lever, IWTS terminals MICRO SWITCH Military-Grade Toggle Switches, TL Series TL SERIES 4-POLE STANDARD ACTUATOR OPTIONS, TERMINALS, & DIMENSIONS Note: Three-position switches shown 4TL1: Four-pole, standard lever, screw terminals 14TL1: Four-pole, standard lever, solder terminals 104TL1: Four pole, standard lever, IWTS terminals 10,9 mm [0.43 in] 1,93 mm ±0,20 mm wide keyway [0.076 in ±0.008 wide keyway] 10,9 mm [0.43 in] 1,93 mm ±0,20 mm wide keyway [0.076 in ±0.008 wide keyway] 1,93 mm ±0,20 mm wide keyway [0.076 in ±0.008 wide keyway] Ø 6,09 mm [Ø 0.24 in] Ø 6,09 mm [Ø 0.24 in] 10,9 mm [0.43 in] 10,9 mm [0.43 in] 34° ±8° total travel 17° ±4° 34° ±8° total travel 34° ±8° total travel 17,0 mm [0.67 in] 3,05 mm [0.12 in] 15/32 - 32 UNS-2 thread to within 1,52 mm [0.060 in] of shoulder 17° ±4° Ø 6,09 mm [Ø 0.24 in] 11,9 mm [0.47 in] 6,09 mm [0.24 in] 3,05 mm [0.12 in] 17,01 mm [0.67 in] 15/32 - 32 UNS 2A thread to within 1,52 mm [0.060 in] of shoulder 6,1 mm [0.24 in] Sealed to prevent entrance of liquids or dust 27,94 mm 34,29 mm [1.10 in] 3,3 mm min. [0.130 in min.] [1.35 in] 17° ±4° 17,0 mm [0.67 in] 3,05 mm [0.12 in] 0,76 mm [0.03 in] (12) 15/32 - 32 UNS-2 thread to within 1,52 mm [0.060 in] of shoulder 4,83 mm dia [0.19 in dia] (12) 11,9 mm [0.47 in] 6,09 mm [0.24 in] Sealed to prevent entrance of liquids or dust 27,94 mm [1.10 in] 3,3 mm min. [0.130 in min.] 34,29 mm [1.35 in] 3,3 mm min. [0.130 in min.] 19,05 mm [0.75 in] Sealed to prevent entrance of liquids or dust 37,3 mm [1.47 in] 3 1 6 5 8 4 7 11 10 9,4 mm [0.37 in] 41,7 mm [1.64 in] 9,4 mm [0.37 in] 9 33,53 mm [1.32 in] 12X 6-32 UNC-2 X (0.260) binding head terminal screw and lockwasher (sems) 7,1 mm [0.28 in] 2 3,3 mm min. [0.130 in min.] 4,57 mm dia [0.18 in dia] (12) 2,29 mm dia [0.09 in dia] (12) 33,53 mm [1.32 in] 9,7 mm [0.38 in] 6,6 mm [0.26 in] 6,4 mm [0.25 in] 7,1 mm [0.28 in] 11,9 mm [0.47 in] 33,53 mm [1.320 in] 9,4 mm [0.37 in] 19,05 mm [0.75 in] 12 9,7 mm [0.38 in] Terminals accept PIN M39029/1-102 2 6,6 mm [0.26 in] 1 3 9,4 mm [0.37 in] 9,7 mm [0.38 in] 4 9,7 mm [0.38 in] 7 8 9 41,7 mm [1.64 in] 9,4 mm [0.37 in] 5 9,4 mm [0.37 in] 6 41,66 mm [1.64 in] 9,7 mm [0.38 in] 9,7 mm [0.38 in] Sealed construction (blue seal) 9,7 mm [0.38 in] 10 12 11 Locking lever dimensions for four-pole TL toggles 34° ±8° total travel 17° ±4° Ø 10,67 mm [Ø 0.42 in] 2,28 mm [0.090 in] 26,67 mm approx. pullout [1.05 in] to change position Sensing and Internet of Things 9 MICRO SWITCH Military-Grade Toggle Switches, TL Series MICRO SWITCH TL SERIES LOCKING CONFIGURATIONS 10 sensing.honeywell.com m WARNING ADDITIONAL MATERIALS The following associated literature is available on the Honeywell web site at sensing.honeywell.com: • Product installation instructions • Product range guide • Product application-specific information – Flight deck toggle switches – Sensors and switches in front loaders PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. m WARNING – Sensors and switches in mobile cranes MISUSE OF DOCUMENTATION – Sensors and switches in oil rig applications • • The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Warranty/Remedy Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship during the applicable warranty period. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items that Honeywell, in its sole discretion, finds defective. The foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. For more information Honeywell Sensing and Internet of Things services its customers through a worldwide network of sales offices and While Honeywell may provide application assistance personally, through our literature and the Honeywell web site, it is buyer’s sole responsibility to determine the suitability of the product in the application. distributors. For application assistance, Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this writing. current specifications, pricing or the However, Honeywell assumes no responsibility for its use. nearest Authorized Distributor, visit sensing.honeywell.com or call: Asia Pacific +65 6355-2828 Europe +44 1698 481481 USA/Canada +1-800-537-6945 Honeywell Sensing and Internet of Things 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywell.com 005430-4-EN | 4 | 02/19 © 2019 Honeywell International Inc. All rights reserved. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Honeywell: TL-10090 TL-11683 TL-11681 TL-10632 TL-10434 TL-11100 TL-10041 TL-10435 TL-10243 TL-11274 TL11169 TL-10045 TL-11682
TL-11683 价格&库存

很抱歉,暂时无法提供与“TL-11683”相匹配的价格&库存,您可以联系我们找货

免费人工找货