35670A

35670A

  • 厂商:

    HP

  • 封装:

  • 描述:

    35670A - Dynamic Signal Analyzer - Agilent(Hewlett-Packard)

  • 数据手册
  • 价格&库存
35670A 数据手册
Agilent 35670A Dynamic Signal Analyzer Versatile two- or four-channel high-performance FFT-based spectrum/network analyzer 122 µHz to 102.4 kHz 16-bit ADC Data Sheet Key Specifications Frequency range 102.4 kHz 1 channel 51.2 kHz 2 channel 25.6 kHz 4 channel 90 dB typical ±0.15 dB ±0.04 dB and ±0.5 degrees 25.6 kHz/1 channel 100, 200, 400, 800 & 1600 lines > 6 Msamples Random, burst random, periodic chirp, burst chirp, pink noise, sine, swept-sine ( Option1D2), arbitrary ( Option 1D4) Dynamic range Accuracy Channel match Real-time bandwidth Resolution Time capture Source types Summary of Features on Standard Instrument The following features are standard with the Agilent 35670A: Display scaling Autoscale Selectable reference Manual Scale Linear or log X-axis Input range tracking Y-axis log X & Y scale markers with expand and scroll Instrument modes FFT analysis Correlation analysis Histogram/time Time capture Measurement Frequency domain Frequency response Linear spectrum Cross spectrum Power spectrum Coherence Power spectral density Marker functions Individual trace markers Coupled multi-trace markers Absolute or relative marker Peak search Harmonic markers Band marker Sideband power markers Waterfall markers Time parameter markers Frequency response markers Time domain (oscilloscope mode) Time waveform Autocorrelation Cross-correlation Orbit diagram Amplitude domain Histogram, PDF, CDF Trace coordinates Linear magnitude Log magnitude dB magnitude Group delay Phase Unwrapped phase Real part Imaginary part Nyquist diagram Polar Signal averaging (FFT mode) Average types (1 to 9,999,999 averages) RMS Time exponential RMS exponential Peak hold Time Averaging controls Overload reject Fast averaging on/off Update rate select Select overlap process percentage Preview time record Trace units Y-axis amplitude: combinations of units, unit value, calculated value, and unit format describe y-axis amplitude Units: volts, g, meters/sec2, inches/sec2, meters/sec, inches/sec, meters, mils, inches, pascals, Kg, N, dyn, lb, user-defined EUs Unit value: rms, peak, peak-to-peak Calculated value: V, V2, V2/Hz, √Hz, V2s/Hz (ESD) Unit format: linear, dB’s with user selectable dB reference, dBm with user selectable impedance. Y-axis phase: degrees, radians X-axis: Hz, cpm, order, seconds, user-defined Measurement control Start measurement Pause/continue measurement Triggering Continuous (Freerun) External (analog or TTL level) Internal trigger from any channel Source synchronized trigger GPIB trigger Armed triggers Automatic/manual RPM step Time step Pre- and post-trigger measurement Delay Display formats Single Quad Dual upper/lower traces Small upper and largelower Front/back overlay traces Measurement state Bode diagram Waterfall display with skew, -45 to 45 degrees Trace grids on/off Display blanking Screen saver Tachometer input: ±4 V or ±20 V range 40 mv or 200 mV resolution Up to 2048 pulses/rev Tach hold-off control 2 Source outputs Random Burst random Periodic chirp Burst chirp Pink noise Fixed sine Note: Some source types are not available for use in optional modes. See option description for details. Data storage functions Built-in 3.5 in., 1.44-Mbyte flexible disk also supports 720-KByte disks, and 2 Mbyte NVRAM disk. Both MS-DOS® and HP-LIF formats are available. Data can be formatted as either ASCII or binary (SDF). The 35670A provides storage and recall from the internal disk, internal RAM disk, internal NVRAM disk, or external GPIB disk for any of the following information: Instrument setup states User-math Time capture buffers Waterfall display data Data tables Trace data Limit data Agilent Instrument BASIC Programs Curve fit/synthesis tables Input channels Manual range Up-only auto range Up/down auto range Anti-alias filters On/Off AC or DC coupling LED half range and overload indicators Floating or grounded A-weight filters On/Off Transducer power supplies (4 ma constant current) Frequency 20 spans from 195 mHz to 102.4 kHz (1 channel mode) 20 spans from 98 mHz to 51.2 kHz (2 channel mode) Digital zoom with 244 µHz resolution throughout the 102.4 kHz frequency bands. GPIB capabilities Conforms to IEEE 488.1/488.2 Conforms to SCPI 1992 Controller with Agilent Instrument Basic Option Calibration & memory Resolution 100, 200, 400, 800 and 1600 lines Single or automatic calibration Built-in diagnostics & service tests Nonvolatile clock with time/date Time/date stamp on plots and saved data files Windows Hann Flat top Uniform Force/exponential Online help Access to topics via keyboard or index Math +,-,*, / Magnitude Square Root LN *jω or /jω Differentiation Integration Conjugate Real and imaginary FFT, FFT-1 EXP PSD A, B, and C weighting Constants K1 thru K5 Functions F1 thru F5 Fan On/Off Analysis Limit test with pass/fail Data table with tabular readout Data editing Time capture functions Capture transient events for repeated analysis in FFT, octave, order, histogram, or correlation modes (except swept-sine). Time-captured data may be saved to internal or external disk, or transferred over GPIB. Zoom on captured data for detailed narrowband analysis. 3 Agilent 35670A Specifications Instrument specifications apply after 15 minutes warm-up and within 2 hours of the last self-calibration. When the internal cooling fan has been turned OFF, specifications apply within 5 minutes of the last self-calibration. All specifications are with 400 line frequency resolution and with anti-alias filters enabled unless stated otherwise. Frequency Maximum range** 1 channel mode Accuracy ±30 ppm (.003%) Single channel ampltude Absolute amplitude accuracy (FFT) (A combination of full scale accuracy, full scale flatness, and amplitude linearity.) ±2.92% (0.25 dB) of reading ±0.025% of full scale FFT full scale accuracy at 1 kHz (0 dBfs) ±0.15 dB (1.74%) FFT full scale flatness (0 dBfs) relative to 1 kHz ±0.2 dB (2.33%) FFT amplitude linearity at 1 kHz measured on +27 dBVrms range with time avg, 0 to -80 dBfs ±0.58% (0.05 dB) of reading ±0.025% of full scale Amplitude resolution (16 bits less 2 dB over-range) with averaging 0.0019% of full scale (typical) Residual DC response (FFT mode) Frequency display (excludes A-weight filter)
35670A 价格&库存

很抱歉,暂时无法提供与“35670A”相匹配的价格&库存,您可以联系我们找货

免费人工找货