10613
SPECIFICATION CONTROL DRAWING
CHEMINAX
77 OHM, AWG 24, 19 STRANDS OF AWG 36,
OPTIMIZED DOUBLE SHIELDS, DATA BUS CABLE, MIL-STD-1553
Date:
2-13-18
Revision:
T
THIS SPECIFICATION SHEET FORMS A PART OF THE LATEST ISSUE OF RAYCHEM SPECIFICATION 1200.
CONSTRUCTION DETAILS
ELECTRICAL CHARACTERISTICS
DIMENSIONS ARE NOMINAL VALUES IN INCHES, UNLESS OTHERWISE CHARACTERISTIC IMPEDANCE
DESIGNATED.
CONDUCTORS
AWG 24,
19 Strands of AWG 36,
Silver-Coated HighStrength Copper Alloy
.0250
(.635 mm)
77 ± 5 ohms, Method C at 1 MHz
MUTUAL CAPACITANCE
30.0 pF/ft. (98.4 pF/m) (maximum)
ATTENUATION
1.4 dB/100 ft. (4.59 dB/100 m) (maximum)
at 1 MHz
SURFACE TRANSFER IMPEDANCE 10 milliohms/meter (maximum)
(Per SAE AS85485)
at 30 MHz
ADDITIONAL REQUIREMENTS
COMPONENT WIRE PRIOR TO CABLING
(Test procedures per SAE AS22759)
DIELECTRICS
Radiation-Crosslinked,
CONDUCTOR RESISTANCE
26.5 ohms/1000 ft. (86.9 ohms/km) (nominal)
Modified ETFE
300 ± 3°C for 1 hour,
Colors - Light Blue/White CROSSLINKING PROOF TEST
.500 inch (12.7 mm) mandrel,
FILLERS
.375 lb (170 g), 2.5 kV dielectric test
Radiation-Crosslinked,
INSULATION (DIELECTRIC)
Modified ETFE
ELONGATION
50% (minimum)
.048 ± .002
(1.22 ± .05 mm)
.032
(.813 mm)
TENSILE STRENGTH
INSULATION FLAWS
SPARK TEST
IMPULSE TEST
1st SHIELD
AWG 38,
Tin-Coated Copper,
Optimized
.113
(2.87 mm)
2nd SHIELD
AWG 38,
Tin-Coated Copper,
Optimized
.130
(3.30 mm)
5000 megohms for 1000 ft.
(1524 megohms-km) (minimum)
LOW TEMPERATURE-COLD BEND
-65 ± 3°C for 4 hours,
.750 inch (19.1 mm) mandrel,
1.00 lb (454 g), 2.5 kV dielectric test
SHRINKAGE
200 ± 3°C for 1 hour,
.125 inch (3.18 mm) (maximum)
in 12 inches (305 mm)
FINISHED CABLE
(Test procedures per NEMA WC 27500, unless otherwise specified)
BLOCKING
CABLE LAY LENGTH
FLAMMABILITY
(Method B of Spec 1200)
JACKET
Radiation-Crosslinked,
Modified ETFE
3.0 kV (rms)
8.0 kV (peak)
INSULATION RESISTANCE
CROSSLINKED VERIFICATION
.146 (3.71 mm)
(nominal)
.154 (3.91 mm)
(maximum)
5000 lbf/in2 (34.5 N/mm2) (minimum)
JACKET
ELONGATION
TENSILE STRENGTH
JACKET FLAWS
SPARK TEST
IMPULSE TEST
JACKET THICKNESS
LOW TEMPERATURE-COLD BEND
200°C for 6 hours
.75 inch (19.1 mm) (minimum),
1.25 inches (31.8 mm) (maximum)
300 ± 5°C for 6 hours,
6.00 inch (152 mm) mandrel
3 seconds (maximum);
3 inches (76.2 mm) (maximum);
no flaming of facial tissue
50% (minimum)
5000 lbf/in2 (34.5 N/mm2) (minimum)
1.0 kV (rms)
6.0 kV (peak)
.008 inch (.203 mm) (nominal)
-55 ± 5°C for 4 hours,
6.00 inch (152 mm) mandrel
1000 volts (rms) (minimum)
VOLTAGE WITHSTAND
(DIELECTRIC)
The conductor AWG size and outer jacket color will be appended to
WEIGHT
26.2 lbs/1000 ft. (39.0 kg/km) (maximum)
the part number. Unless otherwise specified, outer jacket color will
be white designated by a "-9" in accordance with MIL-STD-681,
CABLE IDENTIFICATION: Outer jacket shall be marked in contrasting color at 12
(e.g. 10613-24-9).
inch (305 mm) (nominal) intervals between marks as follows: "10613 RAYCHEM"
Other codes and suffixes may be added to the part number, as
necessary, to capture any additional requirements imposed by the
purchase order.
ENGINEERING REFERENCE
TEMPERATURE RATING
150°C (maximum)
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. TE Connectivity also reserves the
right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
Page 1 of 2
(Page 2 is for internal use only)
Cheminax, Raychem, TE Connectivity, and TE connectivity (logo) are trademarks.
Raychem Wire & Cable
501 Oakside Avenue
Redwood City, California 94063-3800
Phone: 1-800-522-6752 Fax: 1-650-361-6297
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
© 2009-2018 TE Connectivity Ltd. family of companies. All Rights Reserved.