7032AAB

7032AAB

  • 厂商:

    HUMIREL(泰科)

  • 封装:

    -

  • 描述:

    RELAYTIMEDELAY

  • 数据手册
  • 价格&库存
7032AAB 数据手册
Specialty Relays AGASTAT 7000 Series, Industrial Electropneumatic Timing Relay Design & Construction n Available in on-delay, true off-delay, and on/off-delay n Timing from 0.1 seconds to 60 minutes, in linear increments n Oversize adjustment knobs, serrated with high-resolution markings visible from all angles makes the timer easy to set timers There are three main components of Series 7000 Timing Relays: Timing Head circulates air through a variable length to provide linearly adjustable timing. Patented design provides easy adjustment and long service life under severe operating conditions. Precision-Wound Potted Coil Total sealing without external leads eliminates moisture problems, gives maximum insulation value. Snap-Action Switch Assembly — custom-designed over-center mechanism provides snap action. Standard switches are DPDT arrangement. Each of these subassemblies forms self-contained modules assembled at the factory with the other two to afford a wide choice of operating types, coil voltages, and timing ranges. The squared design with front terminals and rear mounting permits the grouping of Series 7000 units side-by-side in minimum panel space. Auxiliary switches may be added in the base of the unit, without affecting the overall width or depth. n Inherent transient immunity Operation n Standard voltages from 6-550VAC and 12-550VDC (special voltages available) n Available in 2-pole or 4-pole models n Numerous enclosure options — explosion proof, dust tight, watertight, hermetically-sealed, NEMA 1 n Auxiliary timed and instantaneous switches can be added for greater switching flexibility n Many mounting options — Surface mount, Panel mount, Octal plug-in mounting n Options: quick-connect terminals, dial stops, and transient protection module n Easy-to-reach screw terminals, all on the face of the unit, clearly identified Two basic operating types are available. “On-Delay” models provide a delay period on energization, at the end of which the switch transfers the load from one set of contacts to another. De-energizing the unit during the delay period immediately recycles the unit, readying it for another full delay period on re-energization. In "Off-Delay" models the switch transfers the load immediately upon energization and the delay period does not begin until the unit is de-energized. At the end of the delay period the switch returns to its original position. Re-energizing the unit during the delay period immediately resets the timing, readying it for another full delay period on de-energization. No power is required during the timing period, providing a true off delay. In addition to these basic operating types, “Double-Head” models offer sequential delays on pull-in and drop-out in one unit. With the addition of auxiliary switches the basic models provide twostep timing. Note: Seismic & radiation tested E7000 models are available. Consult factory for detailed information. n Modular assembly — timing head, coil assembly and switchblock are all individual modules, with switches field-replaceable n File E15631, File LR29186 Product Facts On-delay model 7012 (delay on pickup) Applying voltage to the coil (L1-L2) for at least 50 msec starts a time delay lasting for the preset time. During this period the normally closed contacts (3-5 and 4-6) remain closed. At the end of the delay period the normally closed contacts break and the normally open contacts (1-5 and 2-6) make. The contacts remain in this transferred position until the coil is deenergized, at which time the switch returns to its original position. De-energizing the coil, either during or after the delay period, will recycle the unit within 50 msec. It will then provide a full delay period upon re-energization, regardless of how often the coil voltage is interrupted before the unit has been permitted to "time-out" to its full delay setting. Off-delay model 7022 (delay on dropout) Applying voltage to the coil (for at least 50 msec) will transfer the switch, breaking the normally closed contacts (1-5 and 2-6), and making the normally open contacts (3-5 and 4-6). Contacts remain in this transferred position as long as the coil is energized. The time delay begins immediately upon de-energization. At the end of the delay period the switch returns to its normal position. Re-energizing the coil during the delay period will immediately return the timing mechanism to a point where it will provide a full delay period upon subsequent de-energization. The switch remains in the transferred position. Note: 7032 types and certain models with accessories are not agency approved. Users should thoroughly review the technical data before selecting a product part number. It is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Consult factory for ordering information. R R 12–8 Catalog 5-1773450-5 Revised 3-13 www.te.com Dimensions are shown for reference purposes only. Specifications subject to change. Dimensions are in millimeters unless otherwise specified. USA: +1 800 522 6752 Asia Pacific: +86 0 400 820 6015 UK: +44 800 267 666 For additional support numbers please visit www.te.com Specialty Relays AGASTAT 7000 Series, Industrial Electropneumatic Timing Relay (Continued) Auxiliary Switch Options To increase the versatility of the basic timer models, auxiliary switches may be added to either on-delay or off-delay types. They switch additional circuits, provide two-step timing action, or furnish electrical interlock for sustained coil energization from a momentary impulse, depending on the type selected and its adjustment. They are installed at the factory. All auxiliary switches are SPDT with UL listings of 10A @ 125, 250, or 480 VAC. A maximum of one Code T or two Code L auxiliary switches may be added to each relay. The L or LL switch is available with on-delay relays only. The T switch is available with both the on-delay and off-delay relays. Auxiliary Switch Options for On-Delay Instant Transfer (Auxiliary Switch Code L, maximum of 2 per relay.) 1. Energizing coil begins time delay and transfers auxiliary switch. 2. Main switch transfers after total preset delay. 3. De-energizing coil resets both switches instantly. Auxiliary switch is nonadjustable. Two-Step Timing (Auxiliary Switch Code T, maximum of 1 per relay.) 1. Energizing coil begins time delay. 2. After first delay auxiliary switch transfers. 3. Main switch transfers after total preset delay. 4. De-energizing coil resets both switches instantly. First delay is independently adjustable, up to 30% of overall delay. (Recommended maximum 100 seconds.) Auxiliary Switch Options for Off-Delay In these models the same auxiliary switch provides either two-step timing or instant transfer action, depending on the adjustment of the actuator. Two-Step Timing (Auxiliary Switch Code T, maximum of 1 per relay.) 1. Energizing coil transfers main and auxiliary switches instantly. 2. De-energizing coil begins time delay. 3. After first delay auxiliary switch transfers. 4. Main switch transfers after total preset delay. First delay is independently adjustable, up to 30% of overall delay. (Recommended maximum 100 seconds.) Instant Transfer (Auxiliary Switch Code L, maximum of 1 per relay.) 1. Energizing coil transfers main and auxiliary switches instantly. 2. De-energizing coil resets auxiliary switch and begins time delay. 3. Main switch transfers after total preset delay. Auxiliary switch is factory adjusted to give instant transfer operation. Two-step timing may be set at the factory to customer specification up to a 3:2 ratio. On-delay, Off-delay Model 7032 (Double Head) The Double Head model provides delayed switch transfer on energization of its coil, and delayed resetting upon coil deenergization. Each delay period is independently adjustable. In new circuit designs or the improvement of existing controls now using two or more conventional timers, the Double Head unit offers distinct advantages. Its compact design saves panel space, while the simplified wiring reduces costly interconnection. 12 Specialty Relays On-delay Model 7014, Off-delay Model 7024 With the addition of an extra switch block at the bottom of the basic unit, this version of the Series 7000 offers four pole switch capacity with simultaneous timing or two-step timing. The two-step operation is achieved by factory adjustment to your specifications. For two-step operation, a maximum timing ratio between upper and lower switches of 3:2 is recommended. Once adjusted at the factory, this ratio remains constant regardless of changes in dial settings. (Ex: If upper switch transfer is set on dial at 60 sec., minimum time on lower switch should be 40 sec.) This Series 7000 unit offers many of the performance features found in basic models — voltage ranges, timing and switch capacities. Four pole models add approximately 1-1/4" to the maximum height of the basic model, approximately 1/8" to the depth. They are designed for vertical operation only. 12–9 Catalog 5-1773450-5 Revised 3-13 www.te.com Dimensions are shown for reference purposes only. Specifications subject to change. Dimensions are in millimeters unless otherwise specified. USA: +1 800 522 6752 Asia Pacific: +86 0 400 820 6015 UK: +44 800 267 666 For additional support numbers please visit www.te.com Specialty Relays AGASTAT 7000 Series, Industrial Electropneumatic Timing Relay (Continued) Surge/Transient Protection Option Product Facts Transient Suppressor Option "V" n Protect electronic control circuits from voltage transients generated by the timer coil n Fast response to the rapidly rising back E.M.F. n High performance clamping voltage characteristics n UL recognized, (except varistor and coil together). n Timer NOT polarity sensitive The Surge/Transient Protection Option protects electronic control circuits from transients and surges which are generated when the timer coil is activated. The device is not polarity sensitive and permits the user to initiate, delay, sequence and program equipment actions over a wide range of applications under the most severe operating conditions. The varistor will not affect the operating characteristics of the 7000 Timer. The varistor has bilateral and symmetrical voltage and current characteristics. Timing Specifications (All values shown are at nominal voltage and 25°C unless otherwise specified) Operating Modes — Model 7012/7014 — On-delay (delay on pick-up). Model 7022/7024 — Off-delay (delay on drop-out). Model 7032 — On-delay, off-delay (double head). Timing Adjustment — Timing is set by simply turning the dial to the desired time value. In the zone of approximately 25° separating the high and low end of timing ranges A,D,E, and K, instantaneous operation (no time delay) will occur. All other ranges produce an infinite time delay when the dial is set in this zone. Models 7014 and 7032 are available with letter dials only. The upper end of the time ranges in these models may be twice the values shown. Linear Timing Ranges — Code A B C D E F H I J K Models 7012, 7022, 7024 .1 to 1 Sec. .5 to 5 Sec. 1.5 to 15 Sec 5 to 50 Sec. 20 to 200 Sec. 1 to 10 Min. 3 to 30 Min. 6 to 60 Min. 3 to 120 Cyc. 1 to 300 Sec. Operating Voltage Coil Data (for DPDT) Coil Part # Code Letter Rated Voltage 7000 A B C D E F G H I J 120 240 480 550 24 AC Models 7014, 7032 .2 to 2 Sec. .7 to 7 Sec. 2 to 20 Sec. 10 to 100 Sec. 30 to 300 Sec. 1.5 to 15 Min. 3 to 30 Min. Not Avail. Not Avail. Not Avail. K L 7010 Repeat Accuracy — For delays of 200 seconds or less: For delays greater than 200 seconds: 7012*, 7022, 7024: 7014*: 7032: 7012*, 7022, 7014*, 7024: 7032: DC ±5% ±10% ±15% ±10% ±15% * The first time delay afforded by Model 7012 with H (3 to 30 min.) and I (6 to 60 min.) time ranges or Model 7014 with H time range will be approx. 15% longer than subsequent delays due to coil temperature rise. Reset Time — 50 msec. (except model 7032) Relay Release Time — 50 msec. for on-delay models (7012/7014) Relay Operate Time — 50 msec. for off-delay models (7022/7024) 12 6 208 M N O P Q R S T U V W Y Z 28 48 24 125 12 60 250 550 16 32 96 6 220 X Operating* Voltage Range @ 60Hz 102-132 204-264 408-528 468-605 20.5-26.5 110 220 Operating Voltage Range @50Hz 93.5-121 187-242 127 240 108-140 204-264 Rated Voltage 10.2-13.2 5.1-6.6 178-229 Dual Voltage Coil (Combines A&B) Special AC Coils (L1, L2, etc.) 22.4-30.8 38.4-52.8 19.2-26.4 100-137.5 9.6-13.2 48-66 200-275 440-605 12.8-17.6 25.8-35.2 76.8-105.6 4.8-6.6 176-242 Special DC Coils (X1, X2, etc.) *Four pole Models: Operational voltage range 90% to 110% for AC units; 85% to 110% for DC units. See next page for more coil data. 12–10 Catalog 5-1773450-5 Revised 3-13 www.te.com Dimensions are shown for reference purposes only. Specifications subject to change. Dimensions are in millimeters unless otherwise specified. USA: +1 800 522 6752 Asia Pacific: +86 0 400 820 6015 UK: +44 800 267 666 For additional support numbers please visit www.te.com Specialty Relays AGASTAT 7000 Series, Industrial Electropneumatic Timing Relay (Continued) Timing Specifications (All values shown are at nominal voltage and 25°C unless otherwise specified) Minimum operating voltages are based on vertically mounted 7012 units. 7012 horizontally mounted or 7022 vertically or horizontally mounted units will operate satisfactorily at minimum voltages approximately 5% lower than those listed. AC units drop out at approximately 50% of rated voltage. DC units drop out at approximately 10% of rated voltage. All units may be operated on intermittent duty cycles at voltages 10% above the listed maximums (intermittent duty - maximum 50% duty cycle and 30 minutes “on” time.) Surge/Transient Protection Option Characteristics (DC Timers Only) Coil Voltage Nominal (DC) 12 V 24 V 28 V 32 V 48 V 60 V 96 V 110 V 125 V 220 V 250 V Max Excess Energy Capacity (Joule) 0.4 J 1.8 J 1.8 J 2.5 J 3.57 J 6J 10 J 10 J 10 J 17 J 17 J Max De-energization Transient Voltage 48 V 93 V 93 V 135 V 145 V 250 V 340 V 340 V 340 V 366 V 366 V Surge Life — Applied 100,000 times continuously with the interval of 10 seconds at room temperature. Below 68 VAC: 12A; Above 68 VAC: 35A Temperature Range — Operating — -22°F to +167°F (-30°C to + 75°C) Storage — -40°F to +167°F (-40°C to +75°C) Output/Life Contact Ratings — Contact Capacity in Amps (Resistive Load) Min. 100,000 Operations 15.0 1.0 20.0 20.0 12.0 Min. 1,000,000 Operations 7.0 0.5 15.0 15.0 10.0 12 Specialty Relays Contact Voltage 30 VDC 110 VDC 120 V 60Hz 240 V 60Hz 480 V 60Hz Dielectric — Withstands 1500 volts RMS 60Hz between terminals and ground. 1,000 volts RMS 60 Hz between non-connected terminals. For dielectric specification on hermetically sealed models consult factory. Insulation Resistance — 500 Megohms with 500VDC applied. Temperature Range — Operating — -20°F to +165°F (-29°C to 74°C) Storage — -67°F to +165°F (-55°C to 74°C) Temperature Variation — Using a fixed time delay which was set and measured when the ambient temperature was 77°F (25°C), the maximum observed shift in the average of three consecutive time delays was -20% at -20°F (-29°C) and +20% at 165°F (74°C). Mounting/Terminals — Normal mounting of the basic unit is in a vertical position, from the back of the panel. All units are tested for vertical operation. Basic models (7012, 7022) may also be horizontally mounted, and will be adjusted accordingly when Accessory Y1 is specified in your order. Standard screw terminals (8-32 truss head screws supplied) are located on the front of the unit, with permanent schematic markings. Barrier isolation is designed to accommodate spade or ring tongue terminals, with spacing to meet all industrial control specifications. The basic Series 7000 may also be panel mounted with the addition of a panel mount kit, X option, that includes all necessary hardware and faceplate. This offers the convenience of “out-front” adjustment, with large dial skirt knob. The faceplate and knob blend with advanced equipment and console designs, while the body of the unit and its wiring are protected behind the panel. Other mounting options include plug-in styles and special configurations to meet unusual installation requirements. Contact factory for details. Power Consumption — Approximately 8 watts power at rated voltage . Approximate Weights — Models 7012, 7022 . . . . . . . . . . . . . . . . . . . . . . . 2 lbs. 4 ozs. 7014, 7024 . . . . . . . . . . . . . . . . . . . . . . 2 lbs. 10 ozs. 7032 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 lbs. 5 ozs. Weight may vary slightly with coil voltage. 10 Amps Resistive, 240 VAC 1/4 Horsepower, 120 VAC/240VAC (per pole) 15 Amps 30 VDC (per pole) 5 Amps, General Purpose, 600VAC (per pole) 12–11 Catalog 5-1773450-5 Revised 3-13 www.te.com Dimensions are shown for reference purposes only. Specifications subject to change. Dimensions are in millimeters unless otherwise specified. USA: +1 800 522 6752 Asia Pacific: +86 0 400 820 6015 UK: +44 800 267 666 For additional support numbers please visit www.te.com Specialty Relays AGASTAT 7000 Series, Industrial Electropneumatic Timing Relay (Continued) Outline Dimensions (Dimensions in inches) Models 7012, 7022 Models 7014, 7024 Panel Mount Option “X” Model 7032 Surge/Transient Protection Option 12–12 Catalog 5-1773450-5 Revised 3-13 www.te.com Dimensions are shown for reference purposes only. Specifications subject to change. Dimensions are in millimeters unless otherwise specified. USA: +1 800 522 6752 Asia Pacific: +86 0 400 820 6015 UK: +44 800 267 666 For additional support numbers please visit www.te.com Specialty Relays AGASTAT 7000 Series, Industrial Electropneumatic Timing Relay (Continued) Ordering Information 70 Typical Part No. ‰ 1 2 A D GZ 1. Basic Series: 70 = 7000 series electropneumatic timing relay 2. Operation: 1 = On-delay 2 = Off-delay 3 = On-delay, off-delay (double head) 3. Contact Arrangement: 2 = 2PDT (2 form C) **4 = 4PDT (4 form C) 4. Coil Voltage: AC Coils A = 120VAC, 60 Hz.; 110VAC, 50Hz. B = 240VAC, 60 Hz.; 220VAC, 50Hz. C = 480VAC, 60 Hz. D = 550VAC, 60 Hz. E = 24VAC, 60 Hz. F = 127VAC, 50 Hz. G = 240VAC, 50Hz. H = 12VAC, 60 Hz. K = Dual voltage (combines A & B) L = Special AC coils (L1, L2, etc.) †Models 7014 & 7032 For model 7032 specify separate time range code for each head. Example: AB. Any two ranges may be selected. A = .2 to 2 sec. B = .7 to 7 sec. C = 2 to 20 sec. D = 10 to 100 sec. E = 30 to 300 sec. F = 1.5 to 15 min. H = 3 to 30 min. 6. Options: A1 = Single quick-connect terminals (note 4). A2 = Double quick-connect terminals (note 4). B = Plug-in connectors (note 4). GZ = Enclosure with bottom knockouts (note 1). H2 = Hermetically sealed enclosure, 8 pin solder (notes 1 & 4). H3 = Hermetically sealed enclosure, 8 pin octal (notes 1 & 4). H4 = Hermetically sealed enclosure, 8 screw terminal block (notes 1 & 4). *H6 = Hermetically sealed enclosure, 11 pin solder (notes 1 & 4). *H7 = Hermetically sealed enclosure, 11 pin octal (notes 1 & 4). *H8 = Hermetically sealed enclosure, 11 screw terminal block (notes 1 & 4). l1 = Tamper-proof Cap, opaque black (Cannot be combined with Option X). 12 Specialty Relays 5. Timing Range: Models 7012, 7022 & 7024 A = .1 to 1 sec. B = .5 to 5 sec. C = 1.5 to 15 sec. D = 5 to 50 sec. E = 20 to 200 sec. F = 1 to 10 min. H = 3 to 30 min. I = 6 to 60 min. J = 3 to 120 cyc. K = 1 to 300 sec. DC Coils M = 28VDC N = 48VDC O = 24VDC P = 125VDC Q = 12VDC R = 60VDC S = 250VDC T = 550VDC U = 16VDC V = 32VDC W = 96VDC Y = 6VDC Z = 220VDC X = Special DC coils (X1, X2, etc.) l2 = Tamper-proof Cap, transparent (Cannot be combined with Option X). L = Auxiliary Switch, instant transfer. 7012 only (notes 2 & 6). LL = Two Aux. Switches, instant transfer. On Model 7014 Factory Installed Only. (notes 2 & 6) M = Dust-tight Gasketing (notes 4 & 5). P = Octal Plug Adapter. Can be combined only with options l1,l2. M, S, X, or Y1. (note 4). S = Dial Stops. T = Auxiliary Switch, two-step timing (notes 2 & 6). V = Transient/Surge Protection (for DC coil voltage only). X = Panelmount includes hardware and adjustment for horizontal operation (note 4) Y1 = Horizontal testing, for horizontal operation without panel mounting (note 4). Y2 = Horizontal testing, with Compensating Spring for vertical operation (note 4). Notes: 1. Cannot be combined with B, P or X Options 2. Cannot be combined with B, P or Y2 Options 3. Cannot be combined with GZ, H, l1, l2, K, W or Y1 Options 4. Not Avail. on 4-Pole Models 5. Not Available with L, T or LL options. 6. Not Available on hermetically sealed units. * Sized to accommodate one L or T Auxiliary Switch ** Not available on 7032 model. † Available with letter graduated dials only. Upper end of time range may be twice the value shown †† 120 cycles = 2 sec. Our authorized distributors are more likely to maintain the following items in stock for immediate delivery. 7012AA 7012AE 7012AB 7012AC 7012AD 7012ACL 7012PB 7012PJ 7022AA 7022AE 7022AJ 7022PA 7012AF 7012BC 7012PC 7012PK 7022AB 7022AF 7022AKT 7022PB 7012AH 7012NC 7012PD 7012PKX 7022AC 7022AH 7022BC 7022PC 7012AK 7012PA 7012PF 7012PJX 7022AD 7022AI 7022BK 7022PK 12–13 Catalog 5-1773450-5 Revised 3-13 www.te.com Dimensions are shown for reference purposes only. Specifications subject to change. Dimensions are in millimeters unless otherwise specified. USA: +1 800 522 6752 Asia Pacific: +86 0 400 820 6015 UK: +44 800 267 666 For additional support numbers please visit www.te.com Specialty Relays AGASTAT 7000 Series, Industrial Electropneumatic Timing Relay (Continued) Ordering Options — Can only be ordered as factory installed options (Dimensions, where shown, are in inches) A1 – Single Quick-Connect Terminals A2 – Double Quick-Connect Terminals B – Plug-In Connectors GZ – Metal Enclosure Use with Accessory “C” or “D” below. With knockouts for bottom connection. 3.16" W x 3.84" D x 7.63"H H – Hermetically Sealed Enclosure I – Tamper-Proof Cover L – Auxiliary Switch LL – Auxiliary Switch M – Dust tight P – Octal Plug Adapter S – Dial Stops T – Auxiliary Switch Gasket Gasket V – Transient/Surge Protection X – Panelmount Kit Mounting hardware included. Transient Protection Accessories (Not available for 7032 models) Plug-In Receptacle (Accessory C) Plug-In Receptacle (Accessory D) Screw Terminals Catalog No. 700137. For use with “B” Option. Quick Connect Terminals Catalog No. 700141. For use with “B” Option. Ordering options can only be ordered as factory installed options. 12–14 Catalog 5-1773450-5 Revised 3-13 www.te.com Dimensions are shown for reference purposes only. Specifications subject to change. Dimensions are in millimeters unless otherwise specified. USA: +1 800 522 6752 Asia Pacific: +86 0 400 820 6015 UK: +44 800 267 666 For additional support numbers please visit www.te.com
7032AAB 价格&库存

很抱歉,暂时无法提供与“7032AAB”相匹配的价格&库存,您可以联系我们找货

免费人工找货