0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
HR43-2812

HR43-2812

  • 厂商:

    INTERPOINT

  • 封装:

  • 描述:

    HR43-2812 - DC/DC CONVERTERS 28 VOLT INPUT - Interpoint Corporation Company

  • 数据手册
  • 价格&库存
HR43-2812 数据手册
FEATURES • • • • • –40°C to +85°C operation 16 to 32 VDC input voltage Fully isolated Opto-coupler feedback Switching frequency Single and dual outputs typical 80 kHz, variable freq. Triple output 200 kHz, fixed Topology – Flyback Inhibit function Indefinite short circuit protection Up to 75% efficiency Requires external capacitors DC/DC CONVERTERS 28 VOLT INPUT HR40 SERIES 4 WATT MODELS VDC OUTPUT SINGLE DUAL TRIPLE 5 ±12 +5 & ±12 ±15 +5 & ±15 • • • • • Size (max.): 1.075 x 1.075 x 0.370 inches (27.31 x 27.31 x 9.40 mm) See Section B8, case C2, for dimensions. Weight: 20 grams maximum Screening: Standard only. See Section C2 for screening description. DESCRIPTION The HR40 Series™ DC/DC converters offer the high efficiencies associated with switching regulators, yet have full isolation of input and output grounds. The units are built using thick-film hybrid technology and are sealed in metal packages for high-reliability applications. All models are guaranteed to pass a gross leak test (maximum leak rate of 1 x 10-3 atm-cc/sec). The HR40 Series devices are flyback energy storage switching regulators which require a minimum of components resulting in small package size. Single and dual models self-oscillate at an operating frequency which is an approximate inverse function of the load. At full load, the frequency is typically 80 kHz for single and dual output models. Triple output models operate at a fixed frequency of approximately 200 kHz. A transformer in the forward power circuit and an opto-coupler in the feedback/control loop maintain input to output isolation. Models are available with single 5 volt, dual 12 or 15 volt, or triple (+5 and either ±12 or ±15) outputs with an input voltage range of 16 to 32 VDC. Output power of up to 4 watts is available from the dual output models for either balanced or unbalanced loads; however, at least 25% of the total load should be on the positive output. The single output device can provide 3.5 watts, and the triple output can supply up to 3.2 watts. The high efficiency is almost constant over the entire input voltage range and from approximately 25% of full load to full load. This makes the unit ideal for battery applications. An open collector TTL inhibit is provided to allow power shutdown and startup from a logic input. An open circuit on the inhibit terminal (pin 15) gives normal operation, and a TTL low level shuts down the converter. The inhibit pin has an open circuit voltage of 12 to 28 V. Input current in the shutdown mode will be less than 15 mA. Current limiting is provided on each output for indefinite short circuit protection. Due to the high efficiency, heat sinking requirements are minimized, but consideration should be given to removing self-generated heat when operating these devices at maximum ratings. To increase dissipation, heat conducting material (PCB, copper sheet, heat sink, etc.) should be brought into contact with the converter’s baseplate. The converter can be operated at full load at a case temperature of 85°C, with the output power derated linearly to zero at 105°C. WARNING: EXTERNAL CAPACITORS REQUIRED External capacitors are required on the outputs. Operating the unit without external capacitors will result in damage to the internal circuitry. Minimum recommended capacitor values are given in Tables 1 and 2. For optimum performance, low ESR (Equivalent Series Resistance) solid tantalum capacitors are required. The specifications on the following pages are based on the use of highquality solid tantalums. Operation with different types of capacitors will seriously affect performance. B4-51 HR40 SERIES 4 WATT ABSOLUTE MAXIMUM RATINGS Input Voltage • 16 to 32 VDC Output Power • 3.2 to 4 watts depending on model Lead Soldering Temperature (10 sec) • 300°C Storage Temperature Range (Case) • –40°C to +125°C DC/DC CONVERTERS INHIBIT Inhibit TTL Open Collector • Logic low (output disabled) ≤ 0.8 V • Referenced to input common • Logic high (output enabled) ≥ 12 V TYPICAL CHARACTERISTICS Output Voltage Temperature Coefficient • HR41-2805 100 ppm/°C typ, 200 max. • HR42-28XX 50 ppm/°C typ. • HR43-28XX 100 ppm/°C typ. Input to Output Capacitance • 60 pF typical Isolation • 100 megohm minimum at 500 V Conversion Frequency • Single and dual output models, 80 kHz at full load typical, variable frequency • Triple output models, 200 kHz typical fixed frequency Inhibit Pin Voltage (unit enabled) • 12 to 28 V RECOMMENDED OPERATING CONDITIONS Input Voltage Range • 16 to 32 VDC continuous • 40 V for 50 ms transient Case Operating Temperature (Tc) • –40°C to +85°C full power • –40°C to +105°C absolute Derating Output Power/Current • Linearly from 100% at 85°C to 0% at 105°C WARNING: EXTERNAL CAPACITORS REQUIRED Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified. SINGLE AND DUAL OUTPUT MODELS PARAMETER1 OUTPUT VOLTAGE OUTPUT CURRENT OUTPUT POWER2 OUTPUT RIPPLE LINE REGULATION LOAD REGULATION INPUT VOLTAGE CONDITIONS POUT = 2 W 18 TO 32 VIN Tc = –40°C TO +85°C BW = 1 MHz 18 - 32 VIN, POUT = 2 W NO LOAD TO FULL Tc = –40°C TO +85°C TRANSIENT 50 ms INPUT CURRENT NO LOAD FULL LOAD INHIBITED EFFICIENCY FULL LOAD MIN 4.90 — — — — — 16 — — — — 68 HR41-2805 TYP 5.0 — — 75 5 25 28 — 7 — — 72 MAX 5.10 700 3.5 150 10 50 32 40 10 192 15 — MIN ±11.88 — — — — — 16 — — — — 70 HR42-2812 TYP ±12 — — 75 10 12 28 — 10 — — 75 MAX ±12.12 ±167 4.0 150 20 24 32 40 15 213 15 — MIN ±14.85 — — — — — 16 — — — — 70 HR42-2815 TYP ±15 — — 75 10 12 28 — 10 — — 75 MAX ±15.15 ±133 4.0 150 20 24 32 40 15 213 15 — % mA UNITS VDC mA W mV p-p mV mV VDC V Notes 1. External capacitors required to prevent damage to internal circuitry (see Table 1 for specifications). 2. Dual output models deliver up to 4 watts total for balanced or unbalanced loads, however, the positive output should carry at least 25% of the total load. SINGLE AND DUAL OUTPUT EXTERNAL CAPACITORS OPERATION WITHOUT EXTERNAL CAPACITORS WILL RESULT IN DAMAGE TO THE INTERNAL CIRCUITRY. TABLE 1: EXTERNAL CAPACITOR REQUIREMENTS Required Connection Positive Output (12 & 13) to Output Common (8 & 9) Positive Output (10) to 2 Dual Outputs Output Common (8) HR42-2812 External Capacitor (14) to and Output Common (8)3 HR42-2815 Negative Output (12) to Output Common (8) Model Single Output HR41-2805 Minimum Capacitor Value1 220 µF, 10 V 100 µF, 25 V 100 µF, 25 V 10 µF, 25 V POSITIVE INPUT 1, 2 INHIBIT 15 17, 18 INPUT COMMON FEEDBACK POSITIVE OUTPUT 10 OUTPUT COMMON 8 LOGIC TIMING CONTROL SWITCH VOLTAGE REGULATOR + + EXTERNAL CAPACITORS 100µF NEGATIVE OUTPUT 12 14 10µF + 100µF Table 1 Notes 1. Capacitors should be high quality, low ESR components — solid tantalum is recommended. 2. See Figure 1 for connection diagram 3. Place positive side of capacitor toward pin 8. EXTERNAL CAPACITOR TERMINAL FIGURE 1: DUAL OUTPUT EXTERNAL CAPACITOR CONNECTIONS B4-52 DC/DC CONVERTERS WARNING: EXTERNAL CAPACITORS REQUIRED TRIPLE OUTPUT MODELS PARAMETER1 OUTPUT VOLTAGE 2 HR40 SERIES 4 WATT Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified. HR43-2812 CONDITIONS POUT = 2 W BALANCED LOAD OUTPUT CURRENT OUTPUT POWER OUTPUT RIPPLE 18 TO 32 VIN MAIN AUX MAIN AUX MIN 4.9 ±11.5 10.0 — — — — — — — — 16 — — — — 68 TYP 5.0 ±12.0 — — — 50 50 5 3 15 15 28 — 10 — — 70 MAX 5.1 ±12.5 400 ±50.0 3.2 100 100 10 6 30 30 32 40 20 176 15 — MIN 4.9 ±14.5 10.0 — — — — — — — — 16 — — — — 68 HR43-2815 TYP 5.0 MAX 5.1 UNITS VDC ±15.0 ±15.5 — — — 50 50 5 3 15 12 28 — 10 — — 70 400 ±40.0 3.2 100 100 10 7.5 30 24 32 40 20 176 15 — % mA VDC V mV mV W mV p-p mA Tc = –40°C TO +85°C BW DC TO 1 MHz POUT = 2 W 18 TO 32 VIN MAIN ± AUX LINE REGULATION MAIN ± AUX MAIN ± AUX LOAD REGULATION NO LOAD TO FULL INPUT VOLTAGE Tc = –40°C TO +85°C TRANSIENT 50 ms NO LOAD INPUT CURRENT FULL LOAD INHIBITED EFFICIENCY FULL LOAD Notes 1. External capacitors required to prevent damage to internal circuitry 2. Minimum load required on main output for full power auxiliary oper(see Table 2 for specifications). ation. TRIPLE OUTPUT EXTERNAL CAPACITOR OPERATION WITHOUT EXTERNAL CAPACITORS WILL RESULT IN DAMAGE TO THE INTERNAL CIRCUITRY. TABLE 2: EXTERNAL CAPACITOR REQUIREMENTS FEEDBACK Model HR43-2812 and HR43-2815 Required Connection1 Positive 5 VDC Output (9) to Output Common (6 or 7) Minimum Capacitor Value2 220 µF, 10 V POSITIVE INPUT 1, 2 INHIBIT 15 INPUT COMMON 17, 18 +5 OUTPUT 9 REF. & COMP OUTPUT COMMON 6, 7 8 POSITIVE AUXILIARY OUTPUT 5 NEGATIVE AUXILIARY OUTPUT 220µF EXTERNAL CAPACITOR LOGIC TIMING CONTROL SWITCH Table 2 Notes 1. See Figure 2 for connection diagram. 2. Capacitors should be high quality, low ESR components — solid tantalum is recommended. DUAL TRACKING REGULATOR FIGURE 2: TRIPLE OUTPUT EXTERNAL CAPACITOR CONNECTIONS B4-53 HR40 SERIES 4 WATT DC/DC CONVERTERS PIN OUT WARNING: EXTERNAL CAPACITORS REQUIRED OPERATION WITHOUT EXTERNAL CAPACITORS WILL RESULT IN DAMAGE TO THE INTERNAL CIRCUITRY. Pin 1, 21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17, 181 Single Output Positive Input No connection Case No connection No connection No connection Output Common3 Output Common3 No connection No connection Positive Output3 Positive Output3 No connection Inhibit No connection Input Common Dual Output Positive Input No connection Case No connection No Connection No connection Output Common No connection Positive Output No connection Negative Output No connection Ext. Capacitor Inhibit No connection Input Common Triple Output Positive Input No connection Case Negative Aux. Output Output Common Main2 Output Common Aux.2 Positive Aux. Output +5 VDC Output No connection No connection No connection See Section B8. case C2, for dimensions 18 17 10 12 9 Dot on top of cover indicates pin one. BOTTOM VIEW HR40 No connection No connection Inhibit No connection Input Common FIGURE 3: PIN OUT Pin Out Notes 1. Make external connection to both pins on all models. Pins 1 and 2 positive input Pins 17 and 18 input common 2. Pins 6 and 7 on triple output models are connected internally. 3. On the HR41-2805: Make external connections to both output common pins (8 and 9). Make external connections to both positive output pins (12 and 13). MODEL NUMBERING KEY HR4 Base Model Number of Outputs (1 = single, 2 = dual, 3 = triple) Input Voltage Output Voltage (Auxiliary output on triple output models) 3 - 28 12 B4-54 24021-009-DTS Rev A DQ# 2012 All technical information is believed to be accurate, but no responsibility is assumed for errors or omissions. Interpoint reserves the right to make changes in products or specifications without notice. HR40 Series is a trademark of Interpoint. Copyright © 1994 - 1999 Interpoint. All rights reserved. CASE C Dot on top of case indicates pin one CASES BOTTOM VIEW CASE C1 MSA Series: Screening – Standard, ES, or 883 SMSA Series: Screening – Space Standard, H, or K Seam Seal Projection Weld 0.932 (23.67) 0.025 (0.64) dia. CASE C BOTTOM VIEW See Figures 9 - 11 for pin configurations. Squared corner and dot on top of case indicate pin one. 1 2 3 4 5 1.075 max (27.31) 1.075 max (27.31) Materials Header Case C1 Cold Rolled Steel/Nickel/Gold Cases C2 and C3 Kovar/Nickel/Tin Cover Case C1 Cold Rolled Steel/Nickel Cases C2 and C3 Kovar/Nickel/Tin Pins Case C1 Copper/Nickel/Gold Cases C2 and C3 Kovar/Nickel/Gold, matched glass seal Case dimensions in inches (mm) Tolerance ±0.005 (0.13) for three decimal places ±0.01 (0.3) for two decimal places unless otherwise specified CAUTION Heat from reflow or wave soldering may damage the device. Solder pins individually with heat application not exceeding 300°C for 10 seconds per pin. 0.205 ±0.010 (5.21 ±0.25) 0.270 max. (6.86) 0.000 0.205 ±0.010 (5.21 ±0.25) 0.270 max. (6.86) 0.000 0.132 (3.35) 0.000 0.000 8 7 6 0.132 (3.35) 0.332 (8.43) 0.532 (13.51) 0.732 (18.59) FIGURE 9: CASE C1 BOTTOM VIEW CASE C2 MSR Series: Screening – Standard or ES HR40 Series: No screening options 0.018 ±0.002 dia. (0.46 ±0.05) Dot on top of case indicates pin one 12 0.800 (20.32 9 18 17 0.932 (23.67) 10 34 65 0.205 ±0.010 (5.21 ±0.25) 0.370 max. (9.40) 0.350 (8.89) Marker bead on pin 18 0.100 (2.54) Pins equally spaced 0.800 (20.32) FIGURE 10: CASE C2 FIGURE 8: CASE C MAXIMUM DIMENSIONS Seam Seal BOTTOM VIEW CASE C3 MSF EMI Filter: Screening – Standard or ES 0.018 ±0.002 dia. (0.46 ±0.05) 0.000 Dot on top of case indicates pin one 12 0.800 (20.32 98 0.100 (2.54) 7 FIGURE 11: CASE C3 B8-8 0.800 0.600 (20.32) (15.24) Note: Although every effort has been made to render the case drawings at actual size, variations in the printing process may cause some distortion. Please refer to the numerical dimensions for accuracy. 0.205 ±0.010 (5.21 ±0.25) 0.205 ±0.010 (5.21 ±0.25) 0.370 max. (9.40) 0.350 (8.89) 0.365 max. (9.27) 0.000 0.000 0.300 (7.62) QA SCREENING HR PRODUCTS HR PRODUCTS TEST (HR products) PRE-CAP INSPECTION Method 2017 FINAL ELECTRICAL TEST MIL-PRF-38534, Group A Subgroups 1 and 4: +25°C case HERMETICITY TESTING Gross Leak, Dip (1 x 10-3) FINAL VISUAL INSPECTION Method 2009 STANDARD yes yes yes yes Test methods are referenced to MIL-STD-883 as determined by MILPRF-38534. Applies to the following products: HR700 Series HR300 Series HR150 Series HR120 Series HR40 Series C2-13
HR43-2812 价格&库存

很抱歉,暂时无法提供与“HR43-2812”相匹配的价格&库存,您可以联系我们找货

免费人工找货