0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
MTR283R3S

MTR283R3S

  • 厂商:

    INTERPOINT

  • 封装:

  • 描述:

    MTR283R3S - DC/DC CONVERTERS 28 VOLT INPUT - Interpoint Corporation Company

  • 数据手册
  • 价格&库存
MTR283R3S 数据手册
FEATURES • • • • • • • • • • • –55° to +125°C operation 16 to 40 VDC input Fully isolated Magnetic feedback Fixed frequency 600 kHz typical Topology – Single Ended Forward 50 V for up to 50 ms transient protection Inhibit and synchronization functions Indefinite short circuit protection Up to 30 watts output power Trim and remote sense on single output models • Up to 84% efficiency DC/DC CONVERTERS 28 VOLT INPUT MTR SERIES 30 WATT MODELS VDC OUTPUT SINGLE DUAL TRIPLE 3.3 ±5 +5 & 5 ±12 ±12 12 ±15 +5 & 15 ±15 18 Size (max): Non-flanged: Single and dual output models, case H2 (H4 for MTR Dual with standard or ES screening, ht 0.417", 10.59 mm) 2.125 x 1.125 x 0.400 inches (53.98 x 28.58 x 10.16 mm) Triple output models, case F1, 1.950 x 1.350 x 0.405 inches (49.53 x 34.29 x 10.29 mm) Flanged: Single and dual output models, case K3 (or K5 for MTR Dual with standard or ES screening, ht. 0.417", 10.59 mm) 2.910 x 1.125 x 0.400 inches (73.91 x 28.58 x 10.16 mm) Triple output models, case J1, 2.720 x 1.350 x 0.405 inches (69.09 x 34.29 x 10.29 mm) Weight: Single and dual non-flanged 50 grams max., flanged 52 grams max. Triple non-flanged 58 grams max., flanged 62 grams max. Screening: Standard, ES, or 883 (Class H). DESCRIPTION The MTR Series™ of DC/DC converters offers up to 30 watts of output power from single, dual, or triple output configurations. They operate over the full military temperature range with up to 84% efficiency. MTR converters are packaged in hermetically sealed metal cases, making them ideal for use in military, aerospace and other high reliability applications. SYNCHRONIZATION Synchronizing the converter with the system clock allows the designer to confine switching noise to clock transitions, minimizing interference and reducing the need for filtering. In sync mode, the converter will run at any frequency between 500 kHz and 675 kHz. The sync control operates with a quasi-TTL signal at any duty cycle between 40% and 60%. The sync pin must be connected to input common pin when not in use. CONVERTER DESIGN The MTR converters are constant frequency, pulse-width modulated switching regulators which use a quasi-square wave, single ended, forward converter design. Tight load regulation is maintained via wide bandwidth magnetic feedback and, on single output models, through use of remote sense. On dual output models, the positive output is independently regulated and the negative output is cross regulated through the use of tightly coupled magnetics and shunt regulators. The MTR Series triple output DC/DC converter’s design includes individual regulators on the auxiliary outputs which provide for no cross regulation error when a minimum 500 mA load is maintained on the main (+5) output. Indefinite short circuit protection and overload protection are provided by a constant current-limit feature. This protective system senses current in the converter’s secondary stage and limits it to approximately 115% of the maximum rated output current. MTR converters are provided with internal filtering capacitors that help reduce the need for external components in normal operation. For systems that require compliance with MIL-STD-461C’s CE03 standard, Interpoint offers filter/transient suppression modules (including the FMC-461, FMD-461 and FM-704A series filters) which will result in compliance. Contact your Interpoint representative for further details. WIDE VOLTAGE RANGE MTR converters are designed to provide full power operation over a full 16 to 40 VDC voltage range. Operation below 16 volts, including MIL-STD-704E emergency power conditions is possible with derated power. Refer to the low line dropout graph (Figure 22) for details. IMPROVED DYNAMIC RESPONSE The MTR Series feed-forward compensation system provides excellent dynamic response and noise rejection. Audio rejection is typically 50 dB. The minimum to maximum step line transient response is typically less than 4%. INHIBIT FUNCTION MTR converters provide an inhibit terminal that can be used to disable internal switching, resulting in no output and very low quiescent input current. The converter is inhibited when a TTL compatible low (≤0.8 V) is applied to the inhibit pin. The unit is enabled when the pin, which is internally connected to a pull-up resistor, is left unconnected or is connected to an open-collector gate. The open circuit output voltage associated with the inhibit pin is 9 to 11 V. In the inhibit mode, a maximum of 8 mA must be sunk from the inhibit pin. 89 MTR SERIES 30 WATT ABSOLUTE MAXIMUM RATINGS Input Voltage • 16 to 40 VDC Output Power • 25 to 30 watts depending on model Lead Soldering Temperature (10 sec per pin) • 300°C Storage Temperature Range (Case) • –65°C to +135°C DC/DC CONVERTERS SYNC AND INHIBIT Sync (500 to 675 kHz) • Duty cycle 40% min, 60% max • Logic low 0.8 V max • Logic high 4.5 V min, 5 V max • Referenced to input common • If not used, connect to input common Inhibit TTL Open Collector • Logic low (output disabled) Voltage ≤0.8 V Inhibit pin current 8.0 mA max • Referenced to input common • Logic high (output enabled) Open collector TYPICAL CHARACTERISTICS Output Voltage Temperature Coefficient • 100 ppm/°C typical single and dual outputs • 200 ppm/°C main, 300 ppm/°C aux triple output Input to Output Capacitance • 50 pF typ (100 pF typ triple outputs) Current Limit • 115% of full load typical Isolation • 100 megohm minimum at 500 V Audio Rejection • 40 dB typ (50 dB typ triple output)l Conversion Frequency • Free run 550 min, 600 typ, 650 max kHz • External sync 500 to 675 kHz Inhibit Pin Voltage (unit enabled) • 9 to 11 V RECOMMENDED OPERATING CONDITIONS Input Voltage Range • 16 to 40 VDC continuous • 50 V for 50 msec transient Case Operating Temperature (Tc) • –55°C to +125°C full power • –55°C to +135°C absolute Derating Output Power/Current • Linearly from 100% at 125°C to 0% at 135°C Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified. SINGLE OUTPUT MODELS PARAMETER OUTPUT VOLTAGE OUTPUT CURRENT1 OUTPUT POWER1 OUTPUT RIPPLE VOLTAGE LINE REGULATION2 LOAD REGULATION INPUT VOLTAGE1 NO LOAD TO FULL INPUT CURRENT1 CONDITION VIN = 16 to 40 VDC VIN = 16 to 40 VDC 10 kHz – 2 MHz Tc = –55°C TO +125°C Vin = 16 to 40 VDC Tc = –55°C TO +125°C NO LOAD TO FULL Tc = –55°C TO +125°C CONTINUOUS TRANSIENT 50 ms NO LOAD FULL LOAD INHIBITED 10 kHz – 10 MHz Tc = –55°C TO +125°C SHORT CIRCUIT POWER DISSIPATION RECOVERY1, 4 50% – 100% – 50% TRANSIENT RECOVERY4 16 – 40 – 16 VDC TRANSIENT5 RECOVERY4 DELAY OVERSHOOT FULL LOAD NO LOAD MTR283R3S MIN 3.27 0 0 — — — — — — 16 — — — — — 74 — — — — — — — — — TYP 3.30 –– — 15 — 5 — 2 — 28 — 30 0.94 7 25 76 — 1.4 MAX 3.33 6.06 20 40 50 10 10 10 10 40 50 75 — 8 50 — 10 6 MTR2805S MIN 4.95 0 0 — — — — — — 16 — — — — — 76 — — — — — — — — — TYP 5.00 — — 35 50 10 15 5 15 28 — 35 1.15 3 20 78 — 1.4 MTR2812S MTR2815S MTR2818S MAX MIN TYP MAX MIN TYP MAX MIN TYP MAX UNITS 5.05 11.88 12.00 12.12 14.85 15.00 15.15 17.82 18.00 18.18 VDC 5.0 0 — 2.5 0 — 2.0 0 — 1.67 A 25 50 90 30 50 30 50 40 50 75 — 8 50 — 10 5 0 — — — — — — 16 — — — — — 80 — — — — — — — — — — 25 40 10 15 5 15 28 — 35 1.30 3 20 83 — 1.4 30 50 90 30 50 30 50 40 50 75 — 8 50 — 10 5 0 — — — — — — 16 — — — — — 81 — — — — — — — — — — 25 40 10 15 5 15 28 — 35 1.25 3 20 84 — 1.4 30 50 90 30 50 30 50 40 50 75 — 8 50 — 10 5 0 — — — — — — 16 — — — — — 81 — — — — — — — — — — — — — — — — 28 — — 1.33 — — — — 1.4 — 60 ±500 300 — 0 — 30 40 90 30 50 30 50 40 50 50 — 8 50 — 10 — W mV p-p mV mV VDC V mA A mA mA p-p % W ms INPUT RIPPLE CURRENT EFFICIENCY LOAD FAULT3 STEP LOAD RESP. ±125 ±250 — 200 — — 1.4 0 33 ±300 300 5 50 150 ±200 ±300 60 200 ±200 ±300 — 300 1.4 0 50 5 50 250 ±250 ±400 60 200 ±400 ±500 — 300 1.4 0 120 5 120 600 ±350 ±500 60 200 ±500 ±600 — 300 1.4 0 150 5 150 750 ±600 mV pk — µs — — 5 — — mV pk µs ms STEP LINE RESP. START-UP1 mV pk Notes 1. Tc = –55°C to +125°C 2. Operation is limited below 16V (see Figure 22). 3. Indefinite short circuit protection not guaranteed above 125°C case. 4. Recovery time is measured from application of the transient to point at which Vout is within 1% of final value. 5. Transition time ≥10 µs. 90 DC/DC CONVERTERS DUAL OUTPUT MODELS PARAMETER OUTPUT VOLTAGE OUTPUT CURRENT1, 2 OUTPUT POWER1, 2 OUTPUT RIPPLE VOLTAGE +/– VOUT LINE REGULATION3 VIN = 16 TO 40 VDC Tc = –55°C TO +125°C LOAD REGULATION NO LOAD TO FULL Tc = –55°C TO +125°C CROSS REGULATION EFFECT ON –VOUT INPUT VOLTAGE1 NO LOAD TO FULL INPUT CURRENT SEE NOTE 4 SEE NOTE 5 CONTINUOUS TRANSIENT 50 ms NO LOAD FULL LOAD INHIBITED 10 kHz - 10 MHz POWER DISSIPATION SHORT CIRCUIT1 RECOVERY 50 – 100 – 50% BALANCED TRANSIENT RECOVERY7 16 – 40 – 16 VIN TRANSIENT8 RECOVERY7 DELAY OVERSHOOT FULL LOAD NO LOAD — — 0 50 50 250 — — 0 120 120 600 — — 0 150 CONDITIONS +VOUT –VOUT VIN = 16 TO 40 VDC VIN = 16 TO 40 VDC 10 kHz - 2 MHz Tc = –55°C TO +125°C +VOUT –VOUT +VOUT –VOUT +VOUT –VOUT +VOUT –VOUT MTR2805D MIN TYP MAX 4.95 5.00 5.05 4.92 0 0 — — — — — — — — — — — — 16 0 — — — — 76 — — — — — — — 5.00 2.5 — 20 40 10 50 10 50 5 25 5 25 7 4 28 — 35 1.10 3 15 78 — 1.4 ±200 100 ±200 — 1.4 5.07 4.5 25 50 80 50 100 50 100 30 50 50 100 12 6 40 50 75 — 8 50 — 10 5.0 ±300 200 ±400 300 5 MTR2812D MIN TYP MAX 11.88 12.00 12.12 11.82 0 0 — — — — — — — — — — — — 16 0 — — — — 78 — — — — — — — 12.00 1.25 — 30 40 10 50 10 50 15 30 15 30 4 4 28 — 50 1.34 3 20 81 — 1.4 ±150 100 ±200 — 1.4 12.18 2.25 30 80 120 30 120 50 150 30 120 50 180 8.3 6 40 50 75 — 8 50 — 10 5.0 ±300 200 ±400 300 5 MTR SERIES 30 WATT MTR2815D MIN TYP MAX 14.85 15.00 15.15 14.77 15.00 0 0 — — — — — — — — — — — — 16 0 — — — — 80 — — — — — — — 1.0 — 25 40 10 50 10 50 15 30 15 30 3 4 28 — 50 1.29 3 20 83 — 1.4 ±200 100 ±400 — 1.4 15.23 1.8 30 80 120 30 150 50 180 30 150 50 180 8 6 40 50 75 — 8 50 — 10 5.0 ±400 200 ±500 300 5 150 750 % VDC V mA A mA mA p-p % W ms mV pk µs mV pk µs ms mV mV A W mV p-p UNITS VDC Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified. INPUT RIPPLE CURRENT1 EFFICIENCY LOAD FAULT6 STEP LOAD RESPONSE ± VOUT STEP LINE RESPONSE ± VOUT START–UP1 mV pk Notes 1. Tc = –55°C to +125°C. 2. Up to 90% of the total output current/power is available from either output providing the positive output is carrying at least 10% of the total output power. 3. Operation is limited below 16 V (see Figure 22). 4. Effect on the negative output under the following conditions: +Pout 20% to 80%; –Pout 80% to 20% 5. Effect on the negative output under the following conditions: +Pout 50%; –Pout 10% to 50% 6. Indefinite short circuit protection not guaranteed above 125°C case. 7. Recovery time is measured from application of the transient to point at which Vout is within 1% of final value. 8. Transition time ≥ 10 µs. 91 MTR SERIES 30 WATT TRIPLE OUTPUT MODELS PARAMETER OUTPUT VOLTAGE DC/DC CONVERTERS MTR28512T CONDITION MAIN + AUXILIARY – AUXILIARY MIN 4.95 11.82 11.82 0.5 — — — — — — MAIN ± AUXILIARY — — — — — — 16 — — — — — 72 POWER DISSIPATION SHORT CIRCUIT ALL OUTPUTS SHORTED TOTAL RECOVERY EACH OUTPUT MAIN ± AUXILIARY MAIN ± AUXILIARY MAIN ± AUXILIARY MAIN ± AUXILIARY — — — — — — — — — — — — 1.4 150 500 0.05 3 150 100 1.4 0 0 14 2.0 250 750 0.10 5 250 250 2.0 500 1500 — — — — — — — — — — — — 1.4 150 500 0.05 2 150 100 1.4 0 0 14 2.0 250 750 0.10 5 250 250 2.0 500 1500 W ms mV ms mV ms mV TYP 5.0 12.0 12.0 — 0.416 0.416 20 5 5 — 50 20 10 25 10 30 28 — 70 1.37 3.0 20 75 MAX 5.05 12.18 12.18 4.0 0.750 0.750 20 9 9 30 115 80 20 60 20 75 40 50 100 1.45 8 40 — MIN 4.95 14.77 14.77 0.5 — — — — — — — — — — — — 16 — — — — — 73 MTR28515T TYP 5.0 15.0 15.0 — 0.333 0.333 20 5 5 — 50 20 10 30 10 30 28 — 70 1.37 3.0 20 75 MAX 5.05 15.23 15.23 4.0 0.600 0.600 20 9 9 30 115 80 20 75 50 75 40 50 100 1.45 8 40 — mA A mA mA p-p % VDC mV mV p-p mV W A VDC UNITS Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified. OUTPUT CURRENT1 VIN = 16 TO 40 OUTPUT POWER1 VIN = 16 TO 40 MAIN + AUXILIARY – AUXILIARY MAIN + AUXILIARY – AUXILIARY TOTAL OUTPUT RIPPLE VOLTAGE LINE REGULATION VIN = 16 TO 40 LOAD REGULATION2, 3 INPUT VOLTAGE 10 kHz to 2 MHz MAIN ±AUXILIARY MAIN ± AUXILIARY CONTINUOUS TRANSIENT 50 ms INPUT CURRENT NO LOAD FULL LOAD INHIBITED INPUT RIPPLE CURRENT EFFICIENCY LOAD FAULT4 10 kHz TO 10 MHz STEP LOAD RESPONSE TRANSIENT5 RECOVERY6 STEP LINE RESPONSE VIN = 16 TO 40 START-UP TRANSIENT DELAY OVERSHOOT Notes 1. The sum of the two aux outputs is not to exceed 10 watts. The maximum load per aux output is 9 watts. 2. To maintain regulation when operating the ±Aux at full load, a minimum load of 500 mA is required on the main. 3. Measured on each output one at a time with the other outputs at full load. 4. Indefinite short circuit protection not guaranteed above 125°C (case). 5. Response of each output as all outputs are simultaneously transitioned. Main: 50% - 100% - 50% of main full load Auxiliaries: 25% - 50% - 25% each, of total auxiliary full load 6. Recovery time is measured from application of the transient to point at which Vout is within 1% of regulation. 92 DC/DC CONVERTERS TRIM AND REMOTE SENSE (AVAILABLE ON SINGLE OUTPUT MODELS ONLY) MTR SINGLE OUTPUT CONVERTER 1 +VIN OUTPUT COMMON SENSE RETURN SENSE INPUT COMMON POSITIVE OUTPUT 4 1 3 6 1 RT 5 10 RL SENSE INPUT COMMON POSITIVE OUTPUT 1 +VIN OUTPUT COMMON SENSE RETURN MTR SERIES 30 WATT 4 2 3 6 2 RL MTR SINGLE OUTPUT CONVERTER 10 5 EXTERNAL TRIM CONNECTION 1 Make connections at converter. REMOTE SENSE CONNECTION 2 Make connections at load. FIGURE 1: TRIM CONNECTION1, 2, 3 Trim Formulas Vout = desired output voltage; Rt = trim resistor 3.3V: Rt = 1300 * Vout – 4304 1.2475 5V: Rt = 1300 * Vout – 6512 1.2475 12V: Rt = 1300 * Vout – 15631 1.2475 15V: Rt = 1300 * Vout – 19498 1.2475 FIGURE 2: REMOTE SENSE2, 3 Notes for Remote Sense and Trim 1. When trimming output voltage and/or remote sensing, the total output voltage increase must be less than 0.6 volts at the converters pins to maintain specified performance. 2. If neither voltage trim nor remote sense will be used, connect pin 3 to pin 4 and pin 5 to pin 6 or the output voltage will increase by 1.2 volts. 3. CAUTION: The converter will be permanently damaged if the positive remote sense (pin 6) is shorted to ground. Damage may also result if the output common or positive output is disconnected from the load with the remote sense leads connected to the load. PIN OUT Dot on top of cover indicates pin one. Pin 1 2 3 4 5 6 7 8 9 10 Single Output Positive Input Inhibit Sense Return Output Common Positive Output Positive Sense Case Ground Case Ground Sync Input Common Dual Output Positive Input Inhibit Positive Output Output Common Negative Output Case Ground Case Ground Case Ground Sync Input Common Triple Output Positive Input Main (+5) Output Output Common Neg. Aux. Output Pos. Aux. Output Case Ground Case Ground Inhibit Sync Input Common 1 2 3 4 5 BOTTOM VIEW MTR SINGLE FLANGED AND NON-FLANGED 10 9 8 7 6 Dotted line outlines flanged package option. See pages 10, 13, and for dimensions. FIGURE 3: PIN OUT SINGLE OUTPUT MODELS Dot on top of cover indicates pin one. Squared corner and dot on top of package indicate pin one. 1 1 2 3 4 5 2 3 4 5 BOTTOM VIEW MTR DUAL FLANGED AND NON-FLANGED 10 9 8 7 6 BOTTOM VIEW MTR TRIPLE FLANGED AND NON-FLANGED 10 9 8 7 6 Dotted line outlines flanged package option. See pages 10, 11, 13, 14, and 15 for dimensions. Dotted line outlines flanged package option. See pages 9 and 12 for dimensions. FIGURE 4: PIN OUT DUAL OUTPUT MODELS FIGURE 5: PIN OUT TRIPLE OUTPUT MODELS 1 MTR SERIES 30 WATT DC/DC CONVERTERS SMD NUMBERS STANDARD MICROCIRCUIT DRAWING (SMD) 5962-0150101HXC 5962-9306801HXC 5962-9306901HXC 5962-9307001HXC 5962-9320201HXC 5962-9320501HXC 5962-9307101HXC 5962-9307201HXC 5962-9307301HXC 5962-9307401HXC MTR SERIES SIMILAR PART MTR283R3S/883 MTR2805S/883 MTR2812S/883 MTR2815S/883 MTR2818S/883 MTR2805D/883 MTR2812D/883 MTR2815D/883 MTR28512T/883 MTR28515T/883 MODEL NUMBERING KEY MTR Base Model Input Voltage Output Voltage (Main and aux. Vout for triple models) Number of Outputs (S = single, D = dual, T = triple) Case Option ("F" indicates flanged option, non-flanged case has no designator in this position) Screening (Standard screening has no designator in this position.) 28 512 T F / 883 To indicate the flanged case option change the “X” to “Z” In the SMD number. The SMD number shown is for Class H screening, nonflanged. For exact specifications for an SMD product, refer to the SMD drawing. SMDs can be downloaded from: http://www.dscc.dla.mil/programs/smcr Typical Performance Curves: 25°C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified. 85 16V 80 80 85 16V 82 87 16V 28V EFFICIENCY (%) EFFICIENCY (%) EFFICIENCY (%) 28V 75 28V 75 40V 70 77 40V 72 70 40V 65 65 67 60 5 10 15 20 25 60 62 5 10 15 20 5 10 15 20 25 OUTPUT POWER (Watts) OUTPUT POWER (Watts) OUTPUT POWER (Watts) MTR2805S EFFICIENCY MTR2812S EFFICIENCY MTR2815S EFFICIENCY FIGURE 6 85 16V 80 28V 85 16V 90 FIGURE 7 FIGURE 8 0 10 EFFICIENCY (%) EFFICIENCY (%) ATTENUATION (dB) 20 28V 80 20 30 40 50 60 70 80 90 75 70 40V 65 75 40V 70 60 5 10 15 20 65 5 10 15 OUTPUT POWER (Watts) 100 0.1 1 10 100 MTR2812D EFFICIENCY OUTPUT POWER (Watts) FREQUENCY (kHz) MTR2815D EFFICIENCY AUDIO REJECTION, MTR SERIES FIGURE 9 FIGURE 10 FIGURE 11 2 DC/DC CONVERTERS 20V/div 25W to 12.5W VIN 25W to 2.5W MTR SERIES 30 WATT Typical Performance Curves: 25°C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified. 100mV/div 20mV/div 200mV/div VOUT 12.5W to 25W 2.5W to 25W 50µs/div 16 TO 40V 50µs/div 50% 100% 50µs/div 10% 100% MTR2805S STEP LINE RESPONSE MTR2805S STEP LOAD RESPONSE MTR2805S STEP LOAD RESPONSE FIGURE 12 20V/div 20V/div FIGURE 13 FIGURE 14 –POUT =15W VIN 15W to 7.5W +VOUT VIN 1V/div 20mV/div 100mV/div 7.5W to 15W VOUT –VOUT 500 µs / div MTR2805S TURN-ON INTO NO LOAD 50µs/div 16 TO 40 50µs/div 25% 50% MTR2815D STEP LINE RESPONSE MTR2815D +VOUT STEP LOAD RESPONSE FIGURE 15 FIGURE 16 FIGURE 17 10 9 8 7 2812D 6 5 4 2805D 3 2 1 2815D 0 -1 2815D -2 -3 -4 2812D -5 -6 2805D -7 -8 -9 -10 +POUT 0 3 6 9 12 15 18 21 24 27 30 –POUT 30 27 24 21 18 15 12 9 6 3 0 15W to 3W VIN +VOUT 3W to 15W –VOUT 50µs/div 10% 100% 200µs/div –VOUT VOLTAGE CHANGE (%) 100mV/div 5V/div 20V/div MTR2815D +VOUT STEP LOAD RESPONSE MTR2815D TURN-ON INTO NO LOAD OUTPUT LOAD (Watts) 10% to 90% LOAD +V 90% to 10% LOAD –V CROSS REGULATION FIGURE 18 8 7 6 5 4 3 2 1 0 –1 –2 –3 –4 –5 –6 –7 –8 16.0 FIGURE 19 80 15.5 FIGURE 20 –VOUT VOLTAGE CHANGE (%) 16V 75 2805D COND A 2815D COND B 2805D 2812D INPUT VOLTAGE (Volts) 2812D 15.0 EFFICIENCY (%) 40V 70 28V 65 14.5 14.0 13.5 60 13.0 10 20 30 40 50 9 12 15 18 21 24 27 30 55 5 10 15 20 25 30 OUTPUT LOAD (%) COND. B: 50% LOAD +V, 50% to 10% –V COND. A: 50% LOAD –V, 50% to 10% +V OUTPUT POWER (Watts) 1% DROP CROSS REGULATION MTR SINGLES AND DUALS LOW LINE DROPOUT OUTPUT POWER (WATTS) MTR28512T EFFICIENCY FIGURE 21 FIGURE 22 FIGURE 23 3 MTR SERIES 30 WATT 80 16V 75 DC/DC CONVERTERS 0 10 20 Typical Performance Curves: 25°C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified. 20V/div 100mV/div EFFICIENCY (%) 40V 70 28V 65 ATTENUATION (dB) 30 40 50 60 70 80 90 VIN +5 VOUT +AUX 60 –AUX 1 10 100 55 5 10 15 20 25 30 100 0.1 OUTPUT POWER (WATTS) FREQUENCY (kHz) 50µs/div 16V TO 40V MTR28515T EFFICIENCY MTR SERIES AUDIO REJECTION MTR28515T STEP LINE RESPONSE FIGURE 24 FIGURE 25 FIGURE 26 100mV/div 20V/div 20V/div 5V/div +5 V 50% to 100% 50 µs/div VIN VIN +AUX ±15 VOUT 200mV/div 1ms/div 50% to 100% –AUX 2V/div +5 VOUT 50% 100% 500 µs/div MTR28515T STEP LOAD RESPONSE MTR28515T, MAIN (+5) TURN-ON INTO FULL LOAD MTR28515T, AUX. (±15)TURN-ON INTO FULL LOAD 500µs/div FIGURE 27 16.0 16.0 FIGURE 28 FIGURE 29 INPUT VOLTAGE (VOLTS) INPUT VOLTAGE (VOLTS) 15.5 15.5 15.0 15.0 14.5 14.5 14.0 14.0 13.5 13.5 5 10 15 20 25 30 5 10 15 20 25 30 OUTPUT POWER (WATTS) 1% DROP OUTPUT POWER (WATTS) 1% DROP MTR28512T LOW LINE DROPOUT VS. LOAD MTR28515T LOW LINE DROPOUT VS. LOAD FIGURE 30 FIGURE 31 4 DC/DC CONVERTERS Dot on top of case indicates pin one Materials Header Cold Rolled Steel/Nickel/Gold Cover Kovar/Nickel Pins #52 alloy (all cases) ceramic seal MTR SERIES 30 WATT CASE F BOTTOM VIEW See Figure 33 for pin configuration 1.350 max (34.29) Case dimensions in inches (mm) Tolerance ±0.005 (0.13) for three decimal places ±0.01 (0.2) for two decimal places unless otherwise specified 1.950 max (49.53) CAUTION Heat from reflow or wave soldering may damage the device. Solder pins individually with heat application not exceeding 300°C for 10 seconds per pin. FIGURE 32: CASE F MAXIMUM DIMENSIONS BOTTOM VIEW CASE F1 MTR Series Triple: Screening – Standard, ES, or 883 Seam Seal Platform Header 1.170 (29.72) 0.040 dia. (1.02) Dot on top of case indicates pin one 1 2 3 4 5 10 0.170 (4.32) 0.000 0.405 max (10.29) 9 8 7 6 0.570 (14.48) 0.970 (24.64) 1.370 (34.80) Note: Although every effort has been made to render the case drawings at actual size, variations in the printing process may cause some distortion. Please refer to the numerical dimensions for accuracy. 0.25 (6.4) 1.770 (44.96) 0.000 0.000 0.170 (4.32) 5 MTR SERIES 30 WATT Dot on top of case indicates pin one DC/DC CONVERTERS Materials Header Cold Rolled Steel/Nickel/Gold case H2 Cold Rolled Steel/Nickel/Tin case H4 Cover Kovar/Nickel case H2 Cold Rolled Steel/Nickel/Tin case H4 Pins #52 alloy ceramic seal case H1 compression glass seal case H4 Case dimensions in inches (mm) Tolerance ±0.005 (0.13) for three decimal places ±0.01 (0.3) for two decimal places unless otherwise specified CASE H BOTTOM VIEW See Figures 35 and 36 for pin configurations. 1.125 max (28.58) 2.125 max (53.98) CAUTION Heat from reflow or wave soldering may damage the device. Solder pins individually with heat application not exceeding 300°C for 10 seconds per pin. FIGURE 34: CASE H MAXIMUM DIMENSIONS BOTTOM VIEW CASE H2 MTR Series Single, – Standard, ES, or 883 MTR Series Dual: Screening – 883 Seam Seal Platform 1.110 (28.19) 0.955 (24.26) 0.040 dia (1.02) 1 2 3 4 5 Squared corner and dot on top of case indicate pin one. MTR Series Dual (883) 10 0.155 (3.94) 0.000 0.400 max. (10.16) 0.000 0.000 0.245 (6.22) 0.645 (16.38) 1.045 (26.54) 1.445 (36.70) 1.845 (46.86) 5 6 1.845 (46.86) 0.25 (6.4) 2.090 (53.01) 2.090 (53.01) 9 8 7 6 Squared corner and dot on top of case indicate pin one. 1.110 (28.19) 0.955 (24.26) 1 2 3 4 MTR Series Single 10 0.155 (3.94) 0.000 0.245 (6.22) 0.000 0.645 (16.38) 1.045 (26.54) 1.445 (36.70) 9 8 7 FIGURE 35: CASE H2 6 DC/DC CONVERTERS BOTTOM VIEW CASE H4 MTR Series Dual: Screening – Standard or ES Solder Seal 1.120 (28.45) 0.960 (24.38) 0.040 dia (1.02) 1 2 3 4 5 MTR SERIES 30 WATT Dot on top of case indicates pin one Solder Tip-off 10 0.160 (4.06) 0.000 0.000 0.255 (6.48) 0.655 (16.64) 1.055 (26.80) 1.455 (36.96) 1.855 (47.12) 0.417 max (10.59) 0.25 +0.05/-0.00 (6.4 +1.3/-0.0) 2.110 (53.59) 0.000 9 8 7 6 FIGURE 36: CASE H4 7 MTR SERIES 30 WATT DC/DC CONVERTERS Materials Header Cold Rolled Steel/Nickel/Gold Cover Kovar/Nickel Pins #52 alloy (all cases) ceramic seal Case dimensions in inches (mm) Tolerance ±0.005 (0.13) for three decimal places ±0.01 (0.2) for two decimal places unless otherwise specified CAUTION Heat from reflow or wave soldering may damage the device. Solder pins individually with heat application not exceeding 300°C for 10 seconds per pin. Dot on top of case indicates pin one CASE J BOTTOM VIEW See Figure 38 for pin configuration 1.350 max (34.29) 2.720 max (69.09) Flange Thickness: 0.060 (1.52) FIGURE 37: CASE J MAXIMUM DIMENSIONS BOTTOM VIEW CASE J1 Flanged cases: Designator "F" required in Case Option position of model number. MTR Series Triple: Screening – Standard, ES, or 883 Platform Header Seam Seal 1.170 (29.72) 0.040 dia. (1.02) 0.670 (17.02) Squared corner and dot on top of case indicate pin one. 1 2 3 4 5 0.162 dia (4.11) 0.170 (4.32) 0.000 0.405 max (10.29) 0.25 (6.4) 0.210 (5.33) 10 9 8 7 6 0.170 (4.32) 0.570 (14.48) 0.970 (24.64) 1.370 (34.80) 1.770 (44.96) 0.000 0.000 FIGURE 38: CASE J1 8 2.150 (54.61) DC/DC CONVERTERS Dot on top of case indicates pin one MTR SERIES 30 WATT CASE K BOTTOM VIEW See Figures 40 and 41 for pin configuration 1.125 max (28.58) 2.910 max (73.91) Flange Thickness: Case K3 0.060 (1.52) Case K5 0.067 +0.005/-0.007 (1.70 +0.13/-0.8) Materials Header Case K3 Cold Rolled Steel/Nickel/Gold Case K8 Cold Rolled Steel/Nickel/Tin Cover Case K3 Kovar/Nickel Case K8 Cold Rolled Steel/Nickel/Tin Pins #52 alloy (all cases) Case K3 ceramic seal Case K8 compression glass seal Case dimensions in inches (mm) Tolerance ±0.005 (0.13) for three decimal places ±0.01 (0.2) for two decimal places unless otherwise specified CAUTION Heat from reflow or wave soldering may damage the device. Solder pins individually with heat application not exceeding 300°C for 10 seconds per pin. FIGURE 39: CASE K MAXIMUM DIMENSIONS 9 MTR SERIES 30 WATT DC/DC CONVERTERS BOTTOM VIEW CASE K3 Flanged cases: Designator (F) required in Case Option position of model number. MTR Series Single and Dual: Screening – Standard, ES, or 883 Note: Do ensure timely delivery of product the MTR Series will be built using the most readily available of the cases illustrated below. Also, the MTR Dual, with standard or ES screening, may also be built in case K5. Platform Seam Seal 1.110 (28.19) 0.955 (24.26) 0.040 dia (1.02) 0.555 (14.1) Dot on top of case indicates pin one 1 2 3 4 5 0.162 dia (4.11) MTR Series Single 10 9 8 7 6 0.155 (3.94) 0.000 0.645 (16.38) 1.045 (26.54) 1.445 (36.70) 1.845 (46.86) 0.230 (5.84) 0.000 0.245 (6.22) 0.400 max. (10.16) 0.25 ±0.03 (6.4 ±0.8) 2.320 (58.93) 0.162 dia (4.11) 2.090 (53.09) 2.150 (54.60) 2.320 (58.93) 0.000 Bathtub Seam Seal 1.110 (28.19) 1.035 (26.30) 0.955 (24.26) 0.040 dia (1.02) 0.555 (14.1) Dot on top of case indicates pin one 1 2 3 4 5 MTR Series Single Alternate Case 10 9 8 7 6 0.155 (3.94) 0.075 (1.90) 0.000 0.400 max. (10.16) 0.20 (0.5) 0.000 0.230 (5.84) 0.060 (5.84) 0.000 0.245 (6.22) 0.645 (16.38) 1.045 (26.54) 1.445 (36.70) 1.845 (46.86) 0.25 ±0.03 (6.4 ±0.8) FIGURE 40: CASE K3 (CONTINUED ON NEXT PAGE) 10 DC/DC CONVERTERS Figure 40 continued: BOTTOM VIEW CASE K3 Platform MTR SERIES 30 WATT Seam Seal 1.110 (28.19) 0.955 (24.26) 0.040 dia (1.02) 0.555 (14.1) Dot on top of case indicates pin one 1 2 3 4 5 0.162 dia (4.11) MTR Series Dual 10 9 8 7 6 0.155 (3.94) 0.000 – 0.230 (5.84) 0.000 0.245 (6.22) 0.645 (16.38) 1.045 (26.54) 1.445 (36.70) 1.845 (46.86) 0.400 max. (10.16) 0.25 ±0.03 (6.4 ±0.8) 2.320 (58.93) 0.000 Bathtub Seam Seal 1.110 (28.19) 1.035 (26.30) 0.955 (24.26) 0.040 dia (1.02) 0.555 (14.1) Dot on top of case indicates pin one 1 2 3 4 5 0.162 dia (4.11) MTR Series Dual Alternate Case 10 9 8 7 6 0.155 (3.94) 0.075 (1.90) 0.000 0.645 (16.38) 1.045 (26.54) 1.445 (36.70) 2.090 (53.09) 2.150 (54.60) 0.230 (5.84) 0.060 (5.84) 0.000 0.245 (6.22) 1.845 (46.86) 2.320 (58.93) 0.400 max. (10.16) 0.20 (0.5) 0.000 0.25 ±0.03 (6.4 ±0.8) FIGURE 40: CASE K3 CONTINUED BOTTOM VIEW CASE K5 Flanged cases: Designator "F" required in Case Option position of model number. MTR Series Dual: Screening – Standard or ES Solder Seal 1.115 (28.32) 0.955 (24.26) 0.040 dia (1.02) 0.555 (14.1) 1 2 3 4 5 0.162 dia (4.11) Squared corner and dot on top of case indicate pin one. Solder Tip-off 10 0.155 (3.94) 0.000 – 0.230 (5.84) 0.245 (6.22) 0.645 (16.38) 1.045 (26.54) 1.445 (36.70) 1.845 (46.86) 0.417 max (10.59) 0.25 ±0.03 (6.4 ±0.8) 2.320 (58.93) 0.000 0.000 9 8 7 6 FIGURE 41: CASE K5 11 MTR SERIES 30 WATT TEST PRE-CAP INSPECTION Method 2017, 2032 DC/DC CONVERTERS ENVIRONMENTAL SCREENING STANDARD /ES /883 (Class H)* yes yes yes TEMPERATURE CYCLE (10 times) Method 1010, Cond. C, -65°C to 150°C Method 1010, Cond. B, -55°C to 125°C CONSTANT ACCELERATION Method 2001, 3000 g Method 2001, 500 g BURN-IN Method 1015, 160 hours at 125°C 96 hours at 125°C case (typical) FINAL ELECTRICAL TEST MIL-PRF-38534, Group A Subgroups 1 through 6: -55°C, +25°C, +125°C Subgroups 1 and 4: +25°C case HERMETICITY TESTING Fine Leak, Method 1014, Cond. A Gross Leak, Method 1014, Cond. C Gross Leak, Dip (1 x 10-3) FINAL VISUAL INSPECTION Method 2009 no no no yes yes no no no no yes yes no no no no yes yes no no yes no yes yes no no no yes yes yes no yes yes no yes yes yes Test methods are referenced to MIL-STD-883 as determined by MIL-PRF-38534. *883 products are built with element evaluated components and are 100% tested and guaranteed over the full military temperature range of –55°C to +125°C. Contact Information: Interpoint Headquarters USA Phone: 1-800-822-8782 +425-882-3100 Email: power@intp.com www.interpoint.com Interpoint UK Phone: +44-1252-815511 Email: poweruk@intp.com Interpoint France Phone: +33-134285455 Email: powerfr@intp.com 12 20821-001-DTS Rev F. This revision supercedes all previous releases. All technical information is believed to be accurate, but no responsibility is assumed for errors or omissions. Interpoint reserves the right to make changes in products or specifications without notice. MTR Series is a trademark of Interpoint. Copyright © 1994 - 2003 Interpoint Corporation. All rights reserved.
MTR283R3S 价格&库存

很抱歉,暂时无法提供与“MTR283R3S”相匹配的价格&库存,您可以联系我们找货

免费人工找货