Incremental Shaft Encoder
OPE1275S Single Channel (Tachometer)
OPE2275S Dual Channel
Features:
• Body O.D. = 28mm [1.10”]
• Shaft Diameter 6.35 mm [0.25”]
• 3/8”-32 UNF Thread
• Pulses per revolution 256 maximum
•
•
Analog Output
100 - 5,000 RPM
Description:
The OPE1275S and OPE2275S are designed for small shaft motors. The OPE1275S provides a single channel
analog output for speed of rotation while the OPE2275S provides a dual channel analog output for speed and
direction of rotation.
The output of the OPE1275S provides a rise and fall pulse providing the designer two slopes for each pulse
doubling the count capability. The OPE2275S provides quadrature rise and fall pulse patterns providing the
design engineer 4 times the pulse per revolution count.
Power requirements are 5 volts ± .5 volts.
Electrical connection is achieved with a 4-pin Molex 53048-0410 connector providing V+, Ground and Output pins.
The mating connector is a 4-pin Molex 51021-0400 (Terminal pin 50058 or 50079)
or equivalent.
Frequency response is from DC to 25 kHz providing a maximum of 256 cycles per revolution (CPR) and 1024
quadrature states per revolution (PPR).
This product is designed for general encoding for low-speed applications.
The OPE1275S and OPE2275S are fully assembled and ready to be connected to your application.
Applications:
• Printer motors
• Machine automation
• Machine safety
OPTEK Product Encoder
Channels:
1 = Single channel
2 = Dual Channel
Motor Diameter- 27.5mm
RoHS
Ordering Information
OPE X 275 S - ZZZ
Resolution per revolution:
128 holes per revolution
256 holes per revolution
Shaft Configuration:
S = Extended Shaft
OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747
FAX: (972) 323-2396 sensors@optekinc.com www.optekinc.com
Issue A
10/09
Page 1 of 4
Incremental Shaft Encoder
OPE1275S Single Channel (Tachometer)
OPE2275S Dual Channel
OPE1275S
OPE2275S
PIN #1
Pin Out
1
2
3
4
VCC
CH A
CH B
GND
OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
Issue A 10/09
Page 2 of 4
OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747
FAX: (972) 323-2396 sensors@optekinc.com www.optekinc.com
Incremental Shaft Encoder
OPE1275S Single Channel (Tachometer)
OPE2275S Dual Channel
Absolute Maximum Ratings (TA=25°C unless otherwise noted)
Units
Maximum
-40o C to +85o
Storage Temperature Range
o
Operating Temperature Range
0 C to +85
Power Supply Voltage VCC
Power Dissipation
C
o
C
4.5 to 5.5
VDC
250
mW
(2)
Vibration (5 Hz to 2 kHz)
20
Shaft Axial Play
± 0.51 mm [0.02”]
Off-Axis Mounting Tolerance
0.254 mm [0.01”]
Acceleration
g
rad/sec2
250,000
Mechanical Specifications:
Units
Dimensions
Moment of Inertia
6.48 X 10
Shaft Length
-5
OZ-IN-S2
0.3 to 0.7
Inches
Electrical Characteristics (TA = 25°C unless otherwise noted — for reference only)
SYMBOL
PARAMETER
MIN
TYP
MAX
UNITS
TEST CONDITIONS
VCC
Supply Voltage
4.5
5.0
5.5
V
ICC
Supply Current
-
21
27
mA
VOH
High Level Output Voltage
Vcc-0.5
-
-
V
IC = 100 µA
VOL
Low Level Output Voltage
-
-
0.4
V
IC = 20 mA
TR
Rise Time
-
500
-
ns
10% to 90%, VCC = 5.0 volts
TF
Fall Time
-
100
-
ns
10% to 90%, VCC = 5.0 volts
FR
Frequency Response
-
-
60
kHz
0.10
-
-
inch
-
-
100
rev/sec
H.S.
Rotation
Hole Size
Maximum speed of rotation with 1024
holes per rotation
VCC = 5.0 volts
Encoding Characteristics:
SE
Symmetry Error
0
16
75
QE
Quadrature Error—OPE2275 only
0
12
60
°e
Notes:
1. All parameters measured using pulse technique, Vcc = 5.0 volts and TA = 25°C.
OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747
FAX: (972) 323-2396 sensors@optekinc.com www.optekinc.com
Issue A
10/09
Page 3 of 4
Incremental Shaft Encoder
OPE1275S Single Channel (Tachometer)
OPE2275S Dual Channel
Timing Diagram:
Timing Definitions:
PPR = Pulses Per Revolution
Electrical Degree (°e) = 1/360th of 1 cycle
Cycle = 360 electrical degrees (°e)
Symmetry = Relationship between X & Y in electrical
degrees (°e).
Position Error = The difference between the actual
shaft position and the position indicated by
the encoder cycle count.
Quadrature: The lead or lag difference between
channels “A” and “B” in electrical degrees
(normally 90°e)
Cycle Error = The difference between the actual shaft
rotational position and the cycle count
rotational position.
Rise Time = Time required to switch between 10% and
90% of the highest to lowest signal levels.
Fall Time = Time required to switch between 90% and
10% of the highest to lowest signal levels.
OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
Issue A 10/09
Page 4 of 4
OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747
FAX: (972) 323-2396 sensors@optekinc.com www.optekinc.com
很抱歉,暂时无法提供与“OPE2275S-128”相匹配的价格&库存,您可以联系我们找货
免费人工找货