0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
30ETH06

30ETH06

  • 厂商:

    IRF

  • 封装:

  • 描述:

    30ETH06 - Hyperfast Rectifier - International Rectifier

  • 数据手册
  • 价格&库存
30ETH06 数据手册
Bulletin PD-20880 rev. B 10/06 30ETH06PbF Hyperfast Rectifier Features • • • • • • Hyperfast Recovery Time Low Forward Voltage Drop Low Leakage Current 175°C Operating Junction Temperature Dual Diode Center Tap Lead-Free ("PbF" suffix) trr = 28ns typ. IF(AV) = 30Amp VR = 600V Description/ Applications State of the art Hyperfast recovery rectifiers designed with optimized performance of forward voltage drop, Hyperfast recover time, and soft recovery. The planar structure and the platinum doped life time control guarantee the best overall performance, ruggedness and reliability characteristics. These devices are intended for use in PFC Boost stage in the AC-DC section of SMPS, inverters or as freewheeling diodes. The IR extremely optimized stored charge and low recovery current minimize the switching losses and reduce over dissipation in the switching element and snubbers. Absolute Maximum Ratings Parameters VRRM IF(AV) IFSM TJ, TSTG Peak Repetitive Reverse Voltage Average Rectifier Forward Current Non Repetitive Peak Surge Current @ TC = 103°C @ TJ = 25°C Max 600 30 200 - 65 to 175 Units V A °C Operating Junction and Storage Temperatures Case Styles Base Cathode 1 3 Cathode Anode TO-220AC www.irf.com 1 30ETH06PbF Bulletin PD-20880 rev. B 10/06 Electrical Characteristics @ TJ = 25°C (unless otherwise specified) Parameters VBR, Vr VF Breakdown Voltage, Blocking Voltage Forward Voltage Min Typ Max Units Test Conditions 600 2.0 2.6 V V V μA μA pF nH IR = 100μA IF = 30A, TJ = 25°C IF = 30A, TJ = 150°C VR = VR Rated TJ = 150°C, VR = VR Rated VR = 600V Meas. lead to lead 5mm from package body 1.34 1.75 0.3 60 33 8.0 50 500 - IR Reverse Leakage Current - CT LS Junction Capacitance Series Inductance - Dynamic Recovery Characteristics @ TJ = 25°C (unless otherwise specified) Parameters trr Reverse Recovery Time Min Typ Max Units Test Conditions 28 31 77 35 nC A ns IF = 1.0A, diF/dt = 50A/μs, VR = 30V TJ = 25°C TJ = 125°C TJ = 25°C TJ = 125°C TJ = 25°C TJ = 125°C IF = 30A VR = 200V diF /dt = 200A/μs IRRM Peak Recovery Current - 3.5 7.7 65 345 Qrr Reverse Recovery Charge - Thermal - Mechanical Characteristics Parameters TJ TStg RthJC RthJA RthCS Wt Max. Junction Temperature Range Max. Storage Temperature Range Thermal Resistance, Junction to Case Per Leg Min - 65 - 65 - Typ 0.7 0.2 2.0 0.07 TO-220AC 30ETH06 Max 175 175 1.1 70 12 10 Units °C °C/W Thermal Resistance, Junction to Ambient Per Leg Thermal Resistance, Case to Heatsink Weight g (oz) Kg-cm lbf.in JEDEC Mounting Torque 6.0 5.0 Case Style Marking Device Typical Socket Mount Mounting Surface, Flat, Smooth and Greased 2 www.irf.com 30ETH06PbF Bulletin PD-20880 rev. B 10/06 1000 (μA) 1000 100 10 1 0.1 Tj = 175˚C 150˚C 125˚C 100˚C Reverse Current - I R 25˚C Instantaneous Forward Current - I F (A) 0.01 0.001 100 0.0001 0 100 200 300 400 500 600 Reverse Voltage - VR (V) Fig. 2 - Typical Values Of Reverse Current Vs. Reverse Voltage 1000 10 T = 175˚C J T = 150˚C J T = 25˚C J Junction Capacitance - C T (pF) T J = 25˚C 100 1 0 0.5 1 1.5 2 2.5 3 3.5 Forward Voltage Drop - VFM (V) Fig. 1 - Typical Forward Voltage Drop Characteristics 10 0 100 200 300 400 500 600 Reverse Voltage - VR (V) Fig. 3 - Typical Junction Capacitance Vs. Reverse Voltage 10 Thermal Impedance Z thJC (°C/W) 1 0.1 D = 0.50 D = 0.20 D = 0.10 D = 0.05 D = 0.02 D = 0.01 Single Pulse (Thermal Resistance) Notes: PDM t1 t2 0.01 1. Duty factor D = t1/ t2 2. Peak Tj = Pdm x ZthJC + Tc 0.001 0.00001 0.0001 0.001 0.01 0.1 t1, Rectangular Pulse Duration (Seconds) Fig. 4 - Max. Thermal Impedance Z thJC Characteristics 1 10 www.irf.com 3 30ETH06PbF Bulletin PD-20880 rev. B 10/06 180 Allowable Case Temperature (°C) 90 Average Power Loss ( Watts ) 80 70 60 50 40 30 20 10 0 0 RMS Limit 160 140 120 Square wave (D = 0.50) 100 Rated Vr applied see note (3) DC D = 0.01 D = 0.02 D = 0.05 D = 0.1 D = 0.2 D = 0.5 DC 80 0 5 10 15 20 25 30 35 40 45 Average Forward Current - IF(AV) (A) Fig. 5 - Max. Allowable Case Temperature Vs. Average Forward Current 5 10 15 20 25 30 35 40 45 Average Forward Current - I F(AV) (A) Fig. 6 - Forward Power Loss Characteristics 90 80 70 60 50 40 30 20 IF = 30 A IF = 15 A 1200 V R = 200V T J = 125˚C T J = 25˚C 1000 IF = 30 A IF = 15 A 800 Qrr ( nC ) V R = 200V T J = 125˚C T J = 25˚C trr ( ns ) 600 400 200 10 0 100 di F /dt (A/μs ) Fig. 7 - Typical Reverse Recovery vs. di F /dt 1000 0 100 1000 di F /dt (A/μs ) Fig. 8 - Typical Stored Charge vs. di F /dt (3) Formula used: TC = T J - (Pd + PdREV) x RthJC ; Pd = Forward Power Loss = IF(AV) x VFM @ (IF(AV) / D) (see Fig. 6); PdREV = Inverse Power Loss = VR1 x I R (1 - D); I R @ VR1 = rated VR 4 www.irf.com 30ETH06PbF Bulletin PD-20880 rev. B 10/06 Reverse Recovery Circuit VR = 200V 0.01 Ω L = 70µH D.U.T. diF /dt dif/dt ADJUST G D IRFP250 S Fig. 9- Reverse Recovery Parameter Test Circuit 3 IF 0 t rr ta tb 4 2 Q rr I RRM 0.5 I RRM di(rec)M/dt 0.75 I RRM 5 1 diF /dt f /dt 4. Qrr - Area under curve defined by t rr and IRRM t x I RRM Q rr = rr 2 5. di (rec) M / dt - Peak rate of change of current during t b portion of t rr 1. diF/dt - Rate of change of current through zero crossing 2. IRRM - Peak reverse recovery current 3. trr - Reverse recovery time measured from zero crossing point of negative going IF to point where a line passing through 0.75 IRRM and 0.50 IRRM extrapolated to zero current Fig. 10 - Reverse Recovery Waveform and Definitions www.irf.com 5 30ETH06PbF Bulletin PD-20880 rev. B 10/06 Outline Table Conforms to JEDEC Outline TO-220AC Dimensions in millimeters and (inches) Part Marking Information IRXC Assembly Line EXAMPLE: THIS IS A 30ETH06 LOT CODE 1789 ASSEMBLED ON WW 19, 2001 IN THE ASSEMBLY LINE "C" INTERNATIONAL RECTIFIER LOGO DATE CODE ASSEMBLY LOT CODE P = LEAD-FREE YEAR 1 = 2001 WEEK 19 LINE C PART NUMBER IRMX Assembly Line EXAMPLE: THIS IS A 30ETH06 LOT CODE 1789 ASSEMBLED ON WW 19, 2001 IN THE ASSEMBLY LINE "C" INTERNATIONAL RECTIFIER LOGO PART NUMBER DATE CODE ASSEMBLY LOT CODE YEAR 1 = 2001 WEEK 19 P = LEAD-FREE 6 www.irf.com 30ETH06PbF Bulletin PD-20880 rev. B 10/06 Ordering Information Table Device Code 30 1 E 2 T 3 H 4 06 5 PbF 6 1 2 3 4 4 5 6 - Current Rating (30 = 30A) E = Single Diode Package T = TO-220 H = HyperFast Recovery Voltage Rating (06 = 600V) none = Standard Production PbF = Lead-Free Tube Standard Pack Quantity : 50 pieces Data and specifications subject to change without notice. This product has been designed and qualified for Industrial Level and Lead-Free. Qualification Standards can be found on IR's Web site. IR WORLD HEADQUARTERS: 2 33 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105 TAC Fax: (310) 252-7309 Visit us at www.irf.com for sales contact information. 10/06 www.irf.com 7
30ETH06 价格&库存

很抱歉,暂时无法提供与“30ETH06”相匹配的价格&库存,您可以联系我们找货

免费人工找货