LF1005-S_06

LF1005-S_06

  • 厂商:

    LEM(莱姆)

  • 封装:

  • 描述:

    LF1005-S_06 - Current Transducer - LEM

  • 数据手册
  • 价格&库存
LF1005-S_06 数据手册
Current Transducer LF 1005-S For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). IPN = 1000 A 16110 Electrical data IPN IP RM Primary nominal r.m.s. current Primary current, measuring range @ ± 24 V Measuring resistance @ with ± 15 V with ± 24 V ISN KN VC IC @ ± 1000 A max @ ± 1200 A max @ ± 1000 A max @ ± 1500 A max 1000 0 .. ± 1500 TA = 70°C TA = 85°C RM min RM max RM min RM max 0 0 5 5 18 0 7 0 60.5 10 24 10 15 4 57.5 21 A A Features • Closed loop (compensated) current transducer using the Hall effect according to UL 94-V0. Ω Ω Ω Ω • Insulated plastic case recognized Advantages • • • • • • • Excellent accuracy Very good linearity Low temperature drift Optimized response time Wide frequency bandwidth No insertion losses High immunity to external interference • Current overload capability. Secondary nominal r.m.s. current Conversion ratio Supply voltage (± 5 %) Current consumption 200 mA 1 : 5000 ± 15 .. 24 V 28 (@ ± 24 V) + IS mA Accuracy - Dynamic performance data XG ε L Overall accuracy @ IPN , TA = 25°C Linearity error Offset current @ IP = 0, TA = 25°C Thermal drift of IO Response time 1) @ 90 % of IPN di/dt accurately followed Frequency bandwidth (- 1 dB) ± 0.4 < 0.1 Typ Max ± 0.4 ± 0.5 % % mA mA µs A/µs kHz IO IOT tr di/dt f Applications • AC variable speed drives and servo • Static converters for DC motor drives • Battery supplied applications • Uninterruptible Power Supplies • Switched Mode Power Supplies (UPS) motor drives - 10°C .. + 85°C ± 0.3 100 DC .. 150 General data TA TS RS m Ambient operating temperature Ambient storage temperature Secondary coil resistance @ Mass Standards - 10 .. + 85 °C - 25 .. + 100 °C 48 Ω 51 Ω 550 g EN 50178 : 1997 • Power supplies for welding applications. (SMPS) TA = 70°C TA = 85°C Application Domain • Industrial. Note : 1) With a di/dt of 100 A/µs. page 1/3 060821/7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. w w w .lem.com Current Transducer LF 1005-S Isolation characteristics Vd Vw dCp dCl CTI R.m.s. voltage for AC isolation test, 50 Hz, 1 mn Impulse withstand voltage 1.2/50 µs Creepage distance Clearance distance Comparative Tracking Index (Group IIIa) 3.8 16 Min 20.6 19.6 175 kV kV mm mm Application examples According to EN 50178 and CEI 61010-1 standards and following conditions : • Over voltage category OV 3 • Pollution degree PD2 • Non-uniform field EN 50178 dCp, dCI, V W Single isolation Reinforced isolation Rated isolation voltage 1500 V 1000 V CEI 61010-1 Nominal voltage 2000 V 1000 V Safety This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer's operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a built-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. page 2/3 060821/7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. w w w .lem.com Dimensions LF 1005-S (in mm. 1 mm = 0.0394 inch) Bottom view Back view Front view Top view Connection Mechanical characteristics • General tolerance • Transducer fastening Vertical position ± 0.5 mm Remarks • IS is positive when IP flows in the direction of the arrow. • Temperature of the primary conductor should not exceed • Dynamic performances (di/dt and response time) are best • This is a standard model. For different versions (supply voltages, turns ratios, unidirectional measurements...), please contact us. with a single bar completely filling the primary hole. 100°C. 2 holes ∅ 5.3 mm 2 M5 steel screws Recommended fastening torque 4 Nm or 2.96 Lb. - Ft. or 4 holes ∅ 4.2 mm 4 M4 steel screws Recommended fastening torque 3.2 Nm or 2.37 Lb. - Ft. or 4 holes ∅ 2.25 mm depth10 mm 4 x PT KA30 screws long 10 mm Recommended fastening torque 0.9 Nm or 0.66 Lb. - Ft. • Transducer fastening Horizontal position 4 holes ∅ 5.3 mm 4 M5 steel screws Recommended fastening torque 4 Nm or 2.96 Lb. - Ft. or 4 holes ∅ 2.25 mm depth16 mm 4 x PT KA30 screws long 16 mm Fastening torque, maxi 1 Nm or 0.74 Lb. - Ft. • Primary through-hole 40.5 x 13 mm or ∅ 38 mm • Connection of secondary Molex 5045-03/A page 3/3 060821/7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. w w w .lem.com
LF1005-S_06 价格&库存

很抱歉,暂时无法提供与“LF1005-S_06”相匹配的价格&库存,您可以联系我们找货

免费人工找货