LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
Features
* Package in 12mm tape on 7" diameter reels.
* Compatible with automatic placement equipment.
* Compatible with infrared and vapor phase reflow solder process.
* EIA STD package.
* I.C. compatible.
* Meet green product and Pb-free(According to RoHS)
Package
Dimensions
Part No.
LTST-020ZGL
Lens Color
Water Clear
Source Color
InGaN Green
Notes:
1. All dimensions are in millimeters (inches).
2. Tolerance is ±0.1 mm (.004") unless otherwise noted.
Definition of Distance Between of PAD and Reflector
A: The distance between pad’s bottom and reflector.
B: The tolerance between right and left pad.
C: The distance between pad and reflector.
Part No. : LTST-020ZGL
BNS-OD-C131/A4
Symbol
A
B
C
0
0
0
Dimension (mm)
min
0.05
min
0.03
min
0.05
Page :
1
max
max
max
of
10
LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
℃
Absolute Maximum Ratings at Ta=25℃
Parameter
LTST-020ZGL
Unit
120
mW
(1/10 Duty Cycle, 0.1ms Pulse Width)
100
mA
DC Forward Current
30
mA
Reverse Voltage
5
V
Power Dissipation
Peak Forward Current
Operating Temperature Range
-30℃ to + 85℃
Storage Temperature Range
-40℃ to + 100℃
Reflow Soldering Condition
260℃ For 10 Seconds
Suggest IR Reflow Condition :
R-Reflow Soldering Profile for lead free soldering (Acc. to J-STD-020B)
Part No. : LTST-020ZGL
BNS-OD-C131/A4
Page :
2
of
10
LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
Electrical
Optical
Characteristics
At
Ta=25℃
℃
Symbol
Part No.
LTW-
Min.
Typ.
Max.
Unit
Test Condition
IV
020ZGL
300
-
600
mcd
IF = 20mA
Note 1, 2, 4
2θ1/2
020ZGL
deg
Fig.6
Dominant Wavelength
λd
020ZGL
525
535
nm
IF = 20mA
Note 2, 5
Fig.1
Forward Voltage
VF
020ZGL
3.0
3.5
V
IF = 20mA
ESD-Withstand Voltage
ESD
020ZGL
2K
V
HBM
Parameter
Luminous Intensity
Viewing Angle
110
-
Note : 1. Luminous intensity is measured with a light sensor and filter combination that approximates the
CIE eye-response curve.
2. Iv classification code is marked on each packing bag.
3. Caution in ESD:
Static Electricity and surge damages the LED. It is recommend to use a wrist band or
anti-electrostatic glove when handling the LED. All devices, equipment and machinery
must be properly grounded.
4. CAS140B is the test standard for the Dominant Wavelength & IV.
5. The Dominant Wavelength guarantee should be added +/- 2nm tolerance.
Part
No. : LTST-020ZGL
BNS-OD-C131/A4
Page :
3
of
10
LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
Bin Code List
VF Spec. Table
VF Bin
Forward Voltage (V) at IF = 20mA
Min.
Max.
V1
3.0
3.1
V2
3.1
3.2
V3
3.2
3.3
V4
3.3
3.4
V5
3.4
3.5
V6
3.5
3.6
Tolerance on each Forward Voltage bin is +/-0.10 volt
IV Spec. Table
Luminous Intensity (mcd) at IF = 20mA
IV Bin
Min.
Max.
P1
200
300
P2
300
400
Q1
400
500
Q2
500
600
R1
700
800
Tolerance on each Luminous Intensity bin is +/- 10%.
Part
No. : LTST-020ZGL
BNS-OD-C131/A4
Page :
4
of
10
LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
Typical Electrical / Optical Characteristics Curves
(25°° C Ambient Temperature Unless Otherwise Noted)
Part No. : LTST-020ZGL
BNS-OD-C131/A
Page :
5
of
10
LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
User Guide
Cleaning
Do not use unspecified chemical liquid to clean LED they could harm the package.
If cleaning is necessary, immerse the LED in ethyl alcohol or isopropyl alcohol at
normal temperature for less one minute.
Recommend Printed Circuit Board Attachment Pad
Infrared / vapor phase
Reflow Soldering
Package Dimensions of Tape
Part No. : LTST-020ZGL
BNS-OD-C131/A4
Page :
6
of
10
LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
Package Dimensions of Reel
Notes:
1. Empty component pockets sealed with top cover tape.
2. 7 inch reel-2000 pieces per reel.
3. The maximum number of consecutive missing lamps is two.
4. In accordance with EIA-481-1-B specifications.
5. Vacate 20 cm (min) on start of packing tape and vacate 50 cm (min) on last of packing tape.
Part No. : LTST-020ZGL
BNS-OD-C131/A4
Page :
7
of
10
LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
CAUTIONS
1. Application
The LEDs described here are intended to be used for ordinary electronic equipment (such as office
equipment, communication equipment and household applications).Consult Liteon’s Sales in advance
for information on applications in which exceptional reliability is required, particularly when the failure
or malfunction of the LEDs may directly jeopardize life or health (such as in aviation, transportation,
traffic control equipment, medical and life support systems and safety devices).
2. Storage
The storage ambient for the LEDs should not exceed 85°C temperature or 60% relative humidity.
It is recommended that LEDs out of their original packaging are IR-reflowed within one week.
For extended storage out of their original packaging, it is recommended that the LEDs be stored in a
sealed container with appropriate desiccant, or in a desiccators with nitrogen ambient.
LEDs stored out of their original packaging for more than a week should be baked at about 60 deg C
for at least 24 hours before solder assembly.
3. Cleaning
Use alcohol-based cleaning solvents such as isopropyl alcohol to clean the LED if necessary.
4. Soldering
Recommended soldering conditions:
Reflow soldering
Pre-heat
Pre-heat time
Peak temperature
Soldering time
120~150°C
120 sec. Max.
260°C Max.
30 sec. Max.
Soldering iron
300°C Max.
Temperature
Soldering time 3 sec. Max.
(one time only)
5. Drive Method
An LED is a current-operated device. In order to ensure intensity uniformity on multiple LEDs
connected in parallel in an application, it is recommended that a current limiting resistor be incorporated
in the drive circuit, in series with each LED as shown in Circuit A below.
Circuit model A
LED
Circuit model B
LED
(A) Recommended circuit.
(B) The brightness of each LED might appear different due to the differences in the I-V characteristics
of those LEDs.
6. ESD (Electrostatic Discharge)
Static Electricity or power surge will damage the LED.
Suggestions to prevent ESD damage:
Use of a conductive wrist band or anti-electrostatic glove when handling these LEDs.
All devices, equipment, and machinery must be properly grounded.
Work tables, storage racks, etc. should be properly grounded.
Use ion blower to neutralize the static charge which might have built up on surface of the LED’s
plastic lens as a result of friction between LEDs during storage and handling.
Part
No. : LTST-020ZGL
BNS-OD-C131/A4
Page :
8
of
10
LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
ESD-damaged LEDs will exhibit abnormal characteristics such as high reverse leakage current, low forward
voltage, or “ no lightup ” at low currents.
To verify for ESD damage, check for “ lightup ” and Vf of the suspect LEDs at low currents.
The Vf of “ good ” LEDs should be >2.0V@0.1mA for InGaN product
7.1 Reliability Test
Reference Standard
Note
Number of
Damaged
1000 hrs
0/25
0
o
1000 hrs
0/25
0
o
1000 hrs
0/25
0
1000 hrs
0/25
0
100 cycles
0/25
0
100 cycles
0/25
0
1 time
0/25
0
3 time
0/25
0
Test Item
Test Condition
Steady State Operating Life
Condition
Ta= 25 C, IF=20mA
High Temperature Storage
Ta= 105 C
Low Temperature Storage
Ta= -55 C
Temperature Humidity
Storage
o
o
Ta= 65 C,
o
RH= 90%
o
o
o
Thermal Cycle
-55 C ~25 C ~105 C~ 25 C
30min 5min 30min 5min
Thermal Shock
-40 C ~ 85 C
10min
10min
Solder Resistance
Tsld=260+/- 5 C, 10sec
(Lead Free Solder Profile)
IR-REFLOW
Tsld=250+/- 5 C, 20~40sec
(Lead Free Solder Profile)
o
o
o
o
7.2 Criteria for Judging the Damage
Part
Criteria for Judgment
Min.
Max.
Item
Symbol
Test Conditions
Forward Voltage
VF
IF=20mA
-
U.S.L.*) ╳ 1.1
Luminous Intensity
IV
IF=20mA
U.S.L.**) ╳ 0.7
-
No. : LTST-020ZGL
BNS-OD-C131/A4
Page :
9
of
10
LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
8. Others
The appearance and specifications of the product may be modified for improvement without prior notice.
9. Suggested Checking List
Training and Certification
1. Everyone working in a static-safe area is ESD-certified?
2. Training records kept and re-certification dates monitored?
Static-Safe Workstation & Work Areas
1. Static-safe workstation or work-areas have ESD signs?
2. All surfaces and objects at all static-safe workstation and within 1 ft measure less than 100V?
3. All ionizer activated, positioned towards the units?
4. Each work surface mats grounding is good?
Personnel Grounding
1. Every person (including visitors) handling ESD sensitive (ESDS) items wear wrist strap, heel strap or
conductive shoes with conductive flooring?
2. If conductive footwear used, conductive flooring also present where operator stand or walk?
3. Garments, hairs or anything closer than 1 ft to ESD items measure less than 100V*?
4. Every wrist strap or heel strap/conductive shoes checked daily and result recorded for all DLs?
5. All wrist strap or heel strap checkers calibration up to date?
Note: *50V for Blue LED.
Device Handling
1. Every ESDS items identified by EIA-471 labels on item or packaging?
2. All ESDS items completely inside properly closed static-shielding containers when not at static-safe
workstation?
3. No static charge generators (e.g. plastics) inside shielding containers with ESDS items?
4. All flexible conductive and dissipative package materials inspected before reuse or recycle?
Others
1. Audit result reported to entity ESD control coordinator?
2. Corrective action from previous audits completed?
3. Are audit records complete and on file?
Part No. : LTST-020ZGL
BNS-OD-C131/A4
Page :
10
of
10
很抱歉,暂时无法提供与“LTST-020ZGL”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 4000+1.705404000+0.20636
- 8000+1.697438000+0.20540