0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
3100Y15Q1999

3100Y15Q1999

  • 厂商:

    MACOM

  • 封装:

  • 描述:

    3100Y15Q1999 - Definite Purpose Contactor 1- or 2-pole, 20-40 FLA AC Coil - Tyco Electronics

  • 数据手册
  • 价格&库存
3100Y15Q1999 数据手册
Catalog 1308242 Issued 3-03 PRODUCTS UNLIMITED Model 96 - 3100 series Definite Purpose Contactor 1- or 2-pole, 20-40 FLA AC Coil File E75492 File EN60947-4-1:1991 IEC 947-4-1 Users should thoroughly review the technical data before selecting a product part number. It is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Features • Robust 1- and 2-pole contactors. • Shunt available on 1-pole models. • Convenient mounting plate. Environmental Data Temperature Range: Storage and Operating: -40°C – +65°C. Flammability: UL 94-HB housing. Mechanical Data Contact Data @ 25°C Arrangements: 1 Form X (SPST-NO-DM) with or without shunt and 2 Form X (DPST-NO-DM). Maximum Ratings: See Contact Ratings Table. Material: Silver Cadmium Oxide. Contact Termination: 20, 25, 30 FLA Models Type: #10-32 Screw with quad 0.250” (6.35 mm) quick connects. Wire Size: 16-8 AWG (Stranding must be split for 8 AWG wire.) Tightening Torque: 25 in.-lbs. 40 FLA Models Type: Box Lug with dual 0.250” (6.35 mm) quick connects. Wire Size: 14-4 Cu/Al AWG Tightening Torque: 40 in.-lbs. Coil Termination: Dual 0.250” (6.35 mm) quick connects. Arc Cover: Optional on 20-30 FLA models, standard on 40 FLA models. Weight: One Pole Types: 8 oz. (227 g) approximately. Two Pole Types: 9.6 oz. (273 g) approximately Coil Data @ 25°C Voltage: 24 - 277 VAC, 50/60 Hz. See Coil Data Table below. Insulation Class: UL Class B (130°C). Duty Cycle: Continuous. Contact Ratings Full Load Amps 20 Number of Poles 2 Line Voltage 240/277 480 600 240/277 480 600 240/277 480 600 240/277 480 600 240/277 480 600 240/277 480 600 240/277 480 600 Locked Rotor Amps 120 100 80 150 50 40 150 125 100 150 75 50 150 125 100 240 200 160 240 200 160 Resistive Amps Rating 30 30 30 30 30 30 35 35 35 40 40 40 40 40 40 50 50 50 50 50 50 Maximum Horsepower Voltage Single Phase 120 2 240 3 120 240 120 240 120 240 120 240 120 240 120 240 1 2 2 3 1 2 2 3 2 3 2 3 25 1 25 2 30 1 30 2 40 1 40 2 Coil Data Nominal Coil Voltage Maximum Pickup Volts Drop-Out Volts Range Nominal Inrush VA @ 50 Hz Nominal Inrush VA @ 60 Hz Nominal Sealed VA @ 50 Hz Nominal Sealed VA @ 60 Hz Nominal DC Resistance - Ohms Dimensions are shown for 24 18 6 - 15 22.5 20 7 5.25 16.5 1-Pole Models 120 88 20 - 70 22.5 20 7 5.25 420 208/240 177 40 - 140 22.5 20 7 5.25 1850 277 221 50 - 165 22.5 20 7 5.25 2650 24 18 6 - 15 37 35 8 7 11 2-Pole Models 120 88 20 - 70 37 35 8 7 250 208/240 177 40 - 140 37 35 8 7 1000 277 221 50 - 165 37 35 8 7 1600 830 reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 PRODUCTS UNLIMITED Ordering Information Typical Part No. B 3100 - 20 Q 6 999 1. Series: 3100 = 1- or 2-pole, 20-40 FLA contactor 2.Packaging: Y = Individual Pack - = Bulk Pack A-ZZZ = Customer specific information (assigned by factory) 3.Pole Configuration: 10 = 1 Form X (SPST-NO-DM) 15 = 1 Form X (SPST-NO-DM) with Shunt 20 = 2 Form X (DPST-NO-DM) 4.Coil Voltage (50/60 Hz.): Q = 24VAC T = 120VAC U = 208/240VAC P = 100VAC S = 200VAC V = 277VAC 5.Contact Ratings (Inductive): 1 = 25 FLA on 1-pole models 3 = 20 FLA on 2-pole models 2 = 30 FLA on 1-pole models 5 = 26 FLA on 2-pole models 14 = 35 FLA on 1-pole models 6 = 30 FLA on 2-pole models 19 - 40 FLA on 1-pole models 18 = 40 FLA on 2-pole models 6.Customer ID Suffix: 999 = Standard Model 000-998 = Factory assigned customer ID 7. Option Code: Leave Blank = No customer-specific options A - ZZ = Factory assigned customer-specific options. Standard part numbers listed below are more likely to be available from stock. 3100-15Q2999 3100-15T2999 3100-15U2999 3100-20Q6999 3100-20T6999 3100-20U6999 3100-20Q18999CL 3100-20T18999CL 3100-20U18999CL Outline Dimensions 1-Pole 2.10 Max. (53.3) Termination Options .253 (6.43) 3.30 (83.8) 1.625 .875 (41.28) (22.2) 2.313 (57 .75) 2.445 (62.1) 1.625 (41.3) 2.00 (50.8) 2.541 (64.5) .215 TYP (5.46) Standard on 20, 25, 30, 35 FLA #10-32 Combination Phillips, Slotted & 5/16 Hex Head #12 Washer Special on 20, 25, 30, 35 FLA #10-32 Sems Screw with Pressure Plate Standard on 40 FLA Lug accepts 14-4 Cu/Al AWG 2-Pole 2.10 Max. (53.3) 3.30 (83.8) 2.313 (57 .75) 1.625 .875 (41.28) (22.2) 2.445 (62.1) 1.625 (41.3) 2.00 (50.8) 2.610 (66.3) .215 TYP (5.46) ORDERING NOTE: “Standard” terminals need not be specified in the “Ordering Information” chart above. “Special” terminals are offered on a special order basis. Special order items may be subject to extended leadtimes and significant minimum order quantities. Your Tyco Electronics sales engineer must consult with the factory before providing price and availability information regarding items with these options. Dimensions are shown for reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. 831
3100Y15Q1999 价格&库存

很抱歉,暂时无法提供与“3100Y15Q1999”相匹配的价格&库存,您可以联系我们找货

免费人工找货