0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
801-4234-A0

801-4234-A0

  • 厂商:

    MAGNETROL

  • 封装:

  • 描述:

    801-4234-A0 - Kotron® Model 801 RF Capacitance Transmitter for Level/Flow/Volume - Magnetrol Interna...

  • 数据手册
  • 价格&库存
801-4234-A0 数据手册
Kotron® Model 801 RF Capacitance Transmitter for Level/Flow/Volume DESCRIPTION The Kotron Model 801 Transmitter is a new generation RF Capacitance multi-function transmitter that offers the user unparalleled power. The preamplifier circuit provides installation flexibility of a 2500 feet maximum remote distance. The Model 801 can interface with two separate vessels, essentially making it a mini-multiplexer, while software mathematics allow for the sum or differential of the two signals. FEATURES • Capability for dual input of two probes from separate vessels. • The level signal from one vessel can be mathematically added to or subtracted from another vessel. • Level/Volume and Level/Flow characterization for all standard vessels and flumes/weirs. • Integral keypad on front panel maintains NEMA 4X rating; no need to open the enclosure during calibration or setup. • Provides one 4–20 mA isolated analog output signal. • Four 10-amp SPDT relays provide complete flexibility from simple alarm applications to complex pump control including lead/lag alternation of pumps. • 16-character alphanumeric display of all parameters. • Display may be configured in units of level, volume, or flow. • Continuous diagnostics check all major functions of the device including integrity of the probe. • Unit may be remote mounted up to 2500 feet (760 m) using twisted, shielded pair cable. • Intrinsically safe version can be remote mounted to 800 feet (240 m) and is supplied with on-board barriers. • RS-232 for downloading of collected flow data (up to the last 31 days). APPLICATIONS • Hydrocarbons and solvents • Slurries • Viscous fluids • Open channel flow • High temperature/pressure liquids • Acids TECHNOLOGY The amount of capacitance developed in any vessel is determined by the size (surface area) of the probe, the distance from the probe to its ground reference, and the dielectric constant of the medium being measured. Considering that the probe’s mounting position is fixed and the dielectric of the medium is constant, then the amount of capacitance developed in a vessel becomes dependent upon the amount of the probe which is covered with media. As the media rises and falls in the tank, the amount of capacitance developed between the probe and the ground reference also rises and falls. The Pulsatel circuit mounted on the probe changes the capacitance signal to a digital waveform proportional to the change in level. The amplifier then converts this digital signal into an isolated 4–20 mA analog output signal. TYPICAL APPLICATIONS Level/Volume monitoring of two tanks The Model 801, with its dual input capability, can monitor the level or volume of two different tanks. The tanks can be of different sizes and configuration and contain different materials. The display will provide a visual indication of the level or volume and the alarms can be set up to provide high and low level detection on each tank. P1 P2 HL HL LL LL 2 TYPICAL APPLICATIONS Sum the volume of two tanks P1 Using the dual input, the 801 can measure the total volume of two tanks. For instance there may be a main storage tank plus a smaller day tank. The 801 will display the volume of each tank plus provide a 4–20 mA signal of the total volume. Each tank can be a different size and shape. Alarms can also be provided for high or low level detection. P2 Level differential The 801 is ideal for bar screen applications. Probes can be installed on either side of the bar screen. The 801 can measure the difference in level measured by the two probes. This will provide an indication that the bar screen requires cleaning. The 4–20 mA output can be provided on the actual level or on the level differential between the two probes. Alarms can also be set if the differential reaches a specific value. P1 minus P2 Flow Bar Screen Two Inputs — Differential (Bar Screen) 3 SPECIFICATIONS Supply voltage 120 VAC, 50/60 Hz (+10 / -15%) 240 VAC, 50/60 Hz (+10 / -15%) 24 VDC (±10%) 4–20 mA (isolated), reversible 1000 ohms max. loop resistance RS-232 5 pF minimum / 50,000 pF maximum Better than 1.0% of span ±0.1% ±0.5% Full numeric keypad 16-character alphanumeric LCD display 10 amp @ 120/240 VAC resistive 10 amp @ 30 VDC resistive, 0.5 amp @ 125 VDC resistive 0–50,000 pF 0.50 pF minimum / 50,000 pF maximum 0–120 seconds level rising, falling, both 15 Watts maximum 65 Watts maximum with heater 99% non-condensing (electronics) 0.5 to approximately 2 seconds, depending upon probe capacitance and damping value -4° to +160° F (-20° to +70° C) -40° to +160° F (-40° to +70° C) ±0.01% / degree F (±0.018% / degree C) 2500 feet (760 meters) 800 feet (240 meters) Output: Analog Digital Range Accuracy Repeatability Linearity Data: Entry Indication Relays 4 SPDT: AC DC Set point range Differential range Time delay Power consumption Humidity Response time Ambient temperature (electronics): Without heater and thermostat With heater and thermostat Temperature coefficient of set point Maximum remote mount distance: Standard Intrinsically safe 4 AGENCY Agency FM APPROVALS Protection Method Non-incendive Class I, II, III, Div 2, Groups A, B, C, D, F & G NEMA 4X, IP 65 Area Classification Approved Model Electronics (with any probe) 801-X034-X4X 801-X134-X4X 801-X234-X4X 801-X334-X4X 801-X434-X4X Probe Non hazardous Intrinsically safe NEMA 4X, IP 65 Class I, Div 1, Groups A, B, C, D, E, F & G Class II, Div 1, Groups E, F & G Class III NEMA 4X, IP 65 Electronics 801-X031-X4X 801-X131-X4X 801-X231-X4X 801-X131-X4X 801-X131-X4X Rigid insulated probes only Non-incendive Class I, II, III, Div 2, Groups A, B, C, D, F & G NEMA 4X, IP 65 Class I, Div 1, Groups C & D Class II, Div 1, Groups E, F & G Non hazardous Explosion proof CSA 801-XX34-N4X Electronics Probe Suitable for Class I, II, III, Div 2, Groups A, B, C, D, E, F & G bare probes not approved for Groups E & F TYPE 4X Class I, Div 1, Groups A, B, C, D, E, F & G Class II, Div 1, Groups E, F & G Class III bare probes not approved for Groups E & F TYPE 4X Class I, Div 1, Groups B, C & D Class II, Div 1, Groups E, F & G NEMA 4X, IP 65 Intrinsically safe 801-XX31-N4X Electronics Rigid insulated probes only Suitable for Explosion proof Class I, Div 1, Groups C & D Class II, Div 1, Groups E, F & G TYPE 4X Class I, II, III, Div 2, Groups A, B, C, D, E, F & G TYPE 4X CAUTION: Agency ratings are dependent upon probe selection. 5 MODEL NUMBER BASIC MODEL NUMBER 801 Kotron Transmitter NUMBER OF PROBES/OUTPUT 2 4 1 probe – One 4–20 mA output with RS-232 2 probes – One 4–20 mA output with RS-232 INPUT POWER 0 1 2 3 4 120 240 24 120 240 VAC, 50/60 Hz VAC, 50/60 Hz VDC VAC with heater and thermostat VAC with heater and thermostat REMOTE MOUNTING CONFIGURATION 1 4 NEMA 4X NEMA 4X with intrinsically safe probe circuit HOUSING A N NEMA 4X Noryl electronics with 316 stainless steel remote probe housing NEMA 4X Noryl electronics with aluminum remote probe housing SPECIAL OPTIONS 0 1 2 3 None Mechanical totalizer 31 day data logger (smart watch) Mechanical totalizer and 31 day logger 8 6 0 1 3 4 PROBES A full range of rigid and flexible probes, for conductive and non-conductive process media, is available in various lengths and materials of construction. For further information on probe assemblies, refer to bulletin 50-125. REMOTE CABLE Specify remote cable by exact length between 10 and 999 feet using part number 009-7146-XXX. For lengths from 1000 to 2500 feet, use part number X009-7146-999. Specify total length required. Example: X009-7146-999, X=1200 feet DIMENSIONAL INCHES 9.50 (241) 2.75 (70) 3/4" NPT 3.23 (82) SPECIFICATIONS 4.63 (118) Dia. 3.00 (76) 2.75 (70) Optional Mounting Flange 3/4" NPT 3/4" NPT Optional Mounting Flange 3/4" NPT 4.87 (124) 1.25 (31) .50 (13) .625 (16) Optional Anchor Assembly P/N 032-8814-001 2.95 (75) 5.50 (139) .75 (19) Optional Weight P/N 004-4355-001 4.63 (118) Dia. 3.00 (76) (mm) 9.50 (241) 13.00 (330) 4.67 (119) I.L. 6.00 (152) Electronics Housing Remote Mount/Standard Rigid Probe Remote Mount/Flexible Probe 7 QUALITY The quality assurance system in place at Magnetrol guarantees the highest level of quality throughout the company. Magnetrol is committed to providing full customer satisfaction both in quality products and quality service. Magnetrol’s quality assurance system is registered to ISO 9001 affirming its commitment to known international quality standards providing the strongest assurance of product and service quality available. WARRANTY All Magnetrol electronic level and flow controls are warranted free of defects in materials or workmanship for one full year from the date of original factory shipment. If returned within the warranty period; and, upon factory inspection of the control, the cause of the claim is determined to be covered under the warranty; then, Magnetrol will repair or replace the control at no cost to the purchaser (or owner) other than transportation. Magnetrol shall not be liable for misapplication, labor claims, direct or consequential damage or expense arising from the installation or use of equipment. There are no other warranties expressed or implied, except special written warranties covering some Magnetrol products. For additional information, see Instruction Manual 50-624. 5300 Belmont Road • Downers Grove, Illinois 60515-4499 • 630-969-4000 • Fax 630-969-9489 • www.magnetrol.com 145 Jardin Drive, Units 1 & 2 • Concord, Ontario Canada L4K 1X7 • 905-738-9600 • Fax 905-738-1306 Heikensstraat 6 • B 9240 Zele, Belgium • 052 45.11.11 • Fax 052 45.09.93 Regent Business Ctr., Jubilee Rd. • Burgess Hill, Sussex RH15 9TL U.K. • 01444-871313 • Fax 01444-871317 Copyright © 2009 Magnetrol International, Incorporated. All rights reserved. Printed in the USA. Performance specifications are effective with date of issue and are subject to change without notice. BULLETIN: 50-105.8 EFFECTIVE: July 2009 SUPERSEDES: June 2001
801-4234-A0 价格&库存

很抱歉,暂时无法提供与“801-4234-A0”相匹配的价格&库存,您可以联系我们找货

免费人工找货