KOTRON® MODEL 805 SMART RF LEVEL TRANSMITTER Installation and Operating Manual RF Capacitance Level Measurement 7xxx 6xxx 5xxx 4xxx 3xxx 2xxx 1xxx Read this Manual Before Installing This manual provides information on the Kotron Model 805 Smart RF Transmitter. It is important that all instructions are read carefully and followed in sequence. The QuickStart Installation instructions are a brief guide to the sequence of steps for experienced technicians to follow when installing the equipment. Detailed instructions are included in the Complete Installation section of this manual. Conventions Used in this Manual Certain conventions are used in this manual to convey specific types of information. General technical material, support data, and safety information are presented in narrative form. The following styles are used for notes, cautions, and warnings. Notes Notes contain information that augments or clarifies an operating step. Notes do not normally contain actions. They follow the procedural steps to which they refer. Cautions Cautions alert the technician to special conditions that could injure personnel, damage equipment, or reduce a component’s mechanical integrity. Cautions are also used to alert the technician to unsafe practices or the need for special protective equipment or specific materials. In this manual, a caution box indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. Warnings Warnings identify potentially dangerous situations or serious hazards. In this manual, a warning indicates an imminently hazardous situation which, if not avoided, could result in serious injury or death. Safety Messages The Kotron Model 805 system may be properly installed in Category II, Pollution Degree 2 installations. Follow all standard industry procedures for servicing electrical and computer equipment when working with or around high voltage. Always shut off the power supply before touching any components. Although high voltage is not present in this system, it may be present in other systems. Electrical components are sensitive to electrostatic discharge. To prevent equipment damage, observe safety procedures when working with electrostatic sensitive components. Low Voltage Directive For use in Category II installations. If equipment is used in a manner not specified by manufacturer, protection provided by equipment may be impaired. WARNING! Explosion hazard. Do not connect or disconnect equipment unless power has been switched off or the area is known to be non-hazardous. Notice of Trademark, Copyright, and Limitations Kotron is a registered trademark of Magnetrol International, Incorporated. Kotron Model 805 Smart RF Transmitter is a tradename of Magnetrol International, Incorporated. Copyright © 2004 Magnetrol International, Incorporated. All rights reserved. Magnetrol reserves the right to make changes to the product described in this manual at any time without notice. Magnetrol makes no warranty with respect to the accuracy of the information in this manual. Warranty All Magnetrol/STI electronic level and flow controls are warranted free of defects in materials or workmanship for one full year from the date of original factory shipment. If returned within the warranty period; and, upon factory inspection of the control, the cause of the claim is determined to be covered under the warranty; then, Magnetrol/STI will repair or replace the control at no cost to the purchaser (or owner) other than transportation. Magnetrol/STI shall not be liable for misapplication, labor claims, direct or consequential damage or expense arising from the installation or use of equipment. There are no other warranties expressed or implied, except special written warranties covering some Magnetrol/STI products. Quality Assurance The quality assurance system in place at Magnetrol/STI guarantees the highest level of quality throughout the company. Magnetrol/STI is committed to providing full customer satisfaction both in quality products and quality service. Magnetrol’s quality assurance system is registered to ISO 9001 affirming its commitment to known international quality standards providing the strongest assurance of product/service quality available. Kotron Model 805 Smart RF Level Transmitter Table of Contents 1.0 QuickStart Installation 1.1 Getting Started .......................................................1 1.1.1 Equipment and Tools...................................1 1.1.2 Configuration Information ..........................1 1.2 QuickStart Mounting .............................................2 1.2.1 Probe ...........................................................2 1.2.2 Transmitter ..................................................2 1.3 QuickStart Wiring ..................................................3 1.4 QuickStart Configuration and Calibration (LCD version) ........................................................3 2.0 Complete Installation 2.1 Unpacking ..............................................................5 2.2 Electrostatic Discharge (ESD) Handling Procedure...5 2.3 Before You Begin ....................................................6 2.3.1 Site Preparation............................................6 2.3.2 Equipment and Tools...................................6 2.3.3 Operational Considerations .........................6 2.4 Mounting ...............................................................7 2.4.1 Installing a Rigid Probe................................8 2.4.2 Installing a Flexible Probe ............................8 2.4.3 Installing the Transmitter .............................9 2.5 Wiring ..................................................................10 2.5.1 General Purpose or Non-incendive (CI I, Div 2) ..............................................10 2.5.2 Intrinsically Safe .........................................10 2.6 Configuring & Calibrating the Transmitter (LCD Version)......................................................11 2.6.1 Operating Parameters .................................11 2.6.2 LCD Transmitter Display and Keypad .......12 2.6.3 Password Protection (Default = 0) .............12 2.6.4 LCD Menu: Step-By-Step Procedure .........12 2.7 Configuration Using HART®..............................14 2.7.1 Connections...............................................14 2.7.2 HART Display Menu ................................14 2.7.3 HART Device Description (DD)...............14 2.7.4 HART Menu .............................................15 3.0 Reference Information 3.1 Description...........................................................16 3.2 Theory of Operation ............................................16 3.3 Troubleshooting....................................................17 3.3.1 Troubleshooting System Problems (LCD)..18 3.3.2 Error Messages (LCD) ...............................18 3.3.3 Troubleshooting Flowchart (LCD).............19 3.4 Agency Approvals .................................................22 3.4.1 Agency Specifications – Intrinsically Safe Installation..........................................23 3.5 Parts......................................................................24 3.5.1 Replacement Parts......................................24 3.5.2 Recommended Spare Parts .........................24 3.6 Specifications ........................................................25 3.6.1 Functional..................................................25 3.6.2 Performance ...............................................26 3.6.3 Physical......................................................27 3.7 Model Numbers ...................................................28 3.7.1 Transmitter .................................................28 Glossary ..............................................................................29 Index...................................................................................31 Configuration and Calibration Data Sheet........................32 1.0 QuickStart Installation The QuickStart Installation procedures provide the key steps for mounting, wiring, and configuring the Kotron Model 805 Level Transmitter. These procedures are intended for experienced installers of electronic level measurement instruments. See Complete Installation, Section 2.0, for detailed installation instructions. 1.1 Getting Started Before beginning the QuickStart Installation procedures, have the correct equipment, tools, and information available. 1.1.1 Equipment and Tools • 11⁄8" open-end wrench or adjustable wrench to fit the probe process connection size and type. • 11⁄4" open-end wrench or adjustable wrench to fit adaptor on transmitter housing. • Flat-blade screwdriver • Digital multimeter or digital volt/ammeter • 24 VDC power supply, 23 mA 1.1.2 Configuration Information Some key information is needed to configure the Model 805 transmitter. Complete the following operating parameters table before beginning configuration. Display Units Set 4.0 mA Set 20.0 mA Question What units of measurement will be used? (inches or centimeters) What is the 0% reference point for the 4.0 mA value? What is the 100% reference point for the 20.0 mA value? Answer _____________ _____________ _____________ 1 50-660 Kotron Model 805 Smart RF Level Transmitter 1.2 QuickStart Mounting NOTE: Confirm the configuration style and process connection size and type of the Kotron Model 805 transmitter. Ensure it matches the requirements of the installation before continuing with the QuickStart installation. x x Confirm the model and serial numbers. 1.2.1 Probe | y Carefully place the probe into the vessel. Align the probe process connection with the threaded or flanged mounting on the vessel. z Tighten the probe using the flats of the probe process connection or flange bolts. } x y z 1.2.2 Transmitter { Loosen screw on top of the probe and attach white wire to probe, making sure that spade lug is at a 90° upward angle. Tighten probe screw securely. (See figure below) | Place the transmitter on the probe. } Tighten the connection by using the flats on the adaptor. { 90° Bend 50-660 Kotron Model 805 Smart RF Level Transmitter 2 1.3 QuickStart Wiring WARNING! Explosion hazard. Do not connect or disconnect equipment unless power has been switched off or the area is known to be safe. NOTE: Make sure the electrical wiring to the Kotron Model 805 transmitter is complete and in compliance with all regulations and codes. 1. Remove the cover of the wiring compartment of the transmitter. Black (-) Red (+) (+) (-) 2. Attach a conduit fitting and mount the conduit plug in the spare opening. Pull the power supply wire (twisted, shielded pair of at least 22 AWG) through the conduit fitting. 3. Connect shield to an earth ground at power supply and leave floating at the transmitter. 4. Connect an earth ground to the nearest green ground screw. (Not shown in illustration.) 5. Connect the positive supply wire to the (+) terminal and the negative supply wire to the (-) terminal. 6. Replace the cover and tighten. 1.4 QuickStart Configuration and Calibration (LCD version) NOTE: The Kotron Model 805 transmitter can be equipped with either a 2-line by 8-character LCD. 1. Power-up the transmitter. The display changes every 5 seconds to show one of the three measured values: Level, %Output, and Loop current. 2. Remove the cover of the electronic compartment. Á 3. Use the Up ( ) or Down ( ) Arrow keys to move from one step of the configuration program to the next step. 4. Press the Enter Arrow ( ) key. The last character in the first line of the display changes to an exclamation point (!). For example: Units! xxx Á Enter Down 5. Use the Up ( ) or Down ( ) keys to increase or decrease the value in the display or to scroll through the choices. Á 3 Á Up 50-660 Kotron Model 805 Smart RF Level Transmitter Á 6. Press the Enter Arrow ( ) key to accept a value and move to the next step of the configuration program. 7. The default password is 0. (No password is required.) The following parameter entries are the minimum required for initial setup and calibration. The default password is 0. 1 In or Cm 5 3 Hi Cal 2 Lo Cal Á 4 4mA Level (0%-point) z Hi Cal xxx.x lu Move the media in the tank to a higher level. The greater the amount at level change, the more accurate the level measurement. Scroll down to the Hi Cal display. Press the Enter Arrow ( ) key. Enter the new current media level in the same manner as above. Press the Enter Arrow ( ) key. NOTE: If calibrating the 805 for interface measurement, enter the level of the interface rather than the upper level. The transmitter is now calibrated for this probe in this medium in this tank (or vessel) and it provides a 4–20 mA output over the desired range. Damping factor and Fault output will automatically default to factory set values of 1 second and 22 mA. Changing these values and those for other parameters are covered in detail in the next section, Complete Installation. 50-660 Kotron Model 805 Smart RF Level Transmitter Á Á | Set 20mA xxx.x Scroll down to the Set 20 mA display. Press the Enter Arrow ( ) key. Enter the maximum level value for the desired 20 mA point. Press the Enter Arrow ( ) key. Á { Set 4mA xxx.x Scroll down to the Set 4 mA display. Press the Enter Arrow ( ) key. Enter the minimum level value for the desired 4 mA point. Press the Enter Arrow ( ) key. Á Á Á Á Á 20mA Level (100%-point) y Lo Cal xxx.x lu Scroll down to the Lo Cal display. Press the Enter Arrow ( ) key. Enter the current level (in or cm) of media on the probe by using the Up and Down Arrow ( ) keys. Holding either key down causes the values to change first by 1’s and then by 10’s. Single depression of either key causes the values to change by 0.1’s. Once the desired value is displayed, press the Enter Arrow ( ) key. Á Á x Units lu Scroll down to the Units display. Press the Enter Arrow ( ) key. Select the Units of measurement for the level readout (cm or inches). Press the Enter Arrow ( ) key. Á Á 4 2.0 Complete Installation This section provides detailed procedures for properly installing, configuring, and, as needed, troubleshooting the Kotron Model 805 Level Transmitter. 2.1 Unpacking Unpack the instrument carefully. Make sure all components have been removed from the packing material. Check all the contents against the packing slip and report any discrepancies to the factory. Before proceeding with the installation, do the following: • Inspect all components for damage. Report any damage to the carrier within 24 hours. • Make sure the nameplate model number agrees with the packing slip and purchase order. • Record the model and serial numbers for future reference when ordering parts. 2.2 Electrostatic Discharge (ESD) Handling Procedure Magnetrol’s electronic instruments are manufactured to the highest quality standards. These instruments use electronic components that may be damaged by static electricity present in most work environments. The following steps are recommended to reduce the risk of component failure due to electrostatic discharge. • Ship and store circuit boards in anti-static bags. If an antistatic bag is not available, wrap the board in aluminum foil. Do not place boards on foam packing materials. • Use a grounding wrist strap when installing and removing circuit boards. A grounded workstation is recommended. • Handle circuit boards only by the edges. Do not touch components or connector pins. • Make sure that all electrical connections are completely made and none are partial or floating. Ground all equipment to a good, earth ground. 5 50-660 Kotron Model 805 Smart RF Level Transmitter 2.3 Before You Begin 2.3.1 Site Preparation Each Kotron Model 805 transmitter is built to match the specific physical specifications of the required installation. Make sure the probe connection is correct for the threaded or flanged mounting on the vessel or tank where the transmitter will be placed. See Mounting, Section 2.4. Make sure that the wiring between the power supply and Model 805 transmitter is complete and correct for the type of installation. See Specifications, Section 3.6. When installing the Model 805 transmitter in a general purpose or hazardous area, all local, state, and federal regulations and guidelines must be observed. See Wiring, Section 2.5. 2.3.2 Equipment and Tools No special equipment or tools are required to install the Model 805 transmitter. The following items are recommended: • 11⁄8" Open-end wrench or adjustable wrench to fit the probe process connection size and type • Flat-blade screwdriver • Digital multimeter or digital volt/ammeter • 24 VDC power supply, 23 mA 2.3.3 Operational Considerations The Model 805 transmitter should be located for easy access for service, configuration, and monitoring. There should be sufficient headroom to allow the probe to be inserted into the tank. Special precautions should be made to prevent exposure to corrosive atmosphere, excessive vibration, shock, or physical damage. The transmitter electronics should not be exposed to ambient temperatures above +175° F (+80° C) or below -40° F (-40° C). The proper operating temperature range for the display is -10° to +160° F (-20° to +70° C). The temperature limits for the probe depend on the style and part number of the specific probe used. See Brochure 50-125, Kotron RF Sensing Probes. 50-660 Kotron Model 805 Smart RF Level Transmitter 6 2.4 Mounting The Model 805 transmitter can be mounted to a tank using a variety of process connections. Generally, either a threaded or flanged connection is used. For information about the sizes and types of connections available, see Brochure 50-125, Kotron RF Sensing Probes. Make sure all mounting connections are properly in place on the tank before installing the probe. Make sure the Kotron probe is correct for the intended installation. It is common practice to use the metal tank wall as the reference electrode. In such cases, it is required that the probe housing makes a good electrical connection to the tank wall. If there is any doubt about this connection or to the use of PTFE thread tape gaskets, paint, rust, or any other reason, a separate strap should be installed between the probe housing and the tank. Caution: This unit contains CMOS electronics which may be damaged by static electricity. Do not touch any semi-conductor devices unless you are properly grounded. Metal Walled Tanks On water-based liquids, there should be no problem with sensitivity or linearity. With non-conductive, low dielectric media, sensitivity can be enhanced by locating the probe close to and parallel with the tank wall. If this is not practical, a concentric ground tube surrounding the probe (sometimes called a stilling well), may be the solution. NOTE: These comments are also true for glass-lined metal walled tanks. Tanks/Silos with Non-Conductive Materials of Construction With plastic, concrete, wood, or any other non-conductive walled vessels, the reference electrode mentioned above needs clarification. Most commonly, this electrode will be in the form of a concentric ground tube (i.e. stilling well). In questionable circumstances, consult the factory. In all cases, a good electrical connection must be made between the ground surface and the probe housing. 7 50-660 Kotron Model 805 Smart RF Level Transmitter Transmitter/Probe Assembly Transmitters with probes up to and including 12 inches (305 mm) in length are shipped pre-assembled. All other transmitters are shipped unassembled to avoid damage during transit. These transmitters must be assembled prior to mounting. Choose your particular configuration from the following sections and follow the instructions carefully. 2.4.1 Installing a Rigid Probe x y z { Before installing, ensure the: • Probe has adequate headroom for installation and has unobstructed entry to the bottom of the vessel. • Process temperature, pressure, dielectric, and viscosity are within the probe specifications for the installation. See Specifications, Section 3.6. To install a probe: x Make sure the process connection is at least 3⁄4" NPT or a flanged mounting. y Carefully place the probe into the vessel. Align the gasket on flanged installations. z Align the probe process connection with the threaded or flanged mounting on the vessel. { Tighten the threaded probe process connection using only the flats on the probe. Caution: Packing glands used on all Magnetrol rigid probe assemblies have been sealed at the factory under controlled conditions. Care must be exercised when installing probe assemblies to avoid breaking the pressure tight gland seal, which destroys the seal. 2.4.2 Installing a Flexible Probe Caution: Flexible probes are shipped with the cable clamp and the packing gland nut hand tightened. The end of a flexible probe MUST be kept taut by attaching the anchor end at the bottom of the vessel or by using a Magnetrol supplied probe weight. Caution: Do not discard the Mylar housing insulator. Caution: The probe cable must not be in contact with any metallic surface in its final installation position. 50-660 Kotron Model 805 Smart RF Level Transmitter 8 To install a probe: Probe Connection Screw ➃➉ Mylar Housing Insulator (slips over clamp) ➄➉ Socket Head Clamp Screws (2) ➅➆ Upper Probe Mounting Gland ➂ Lower Probe Mounting Gland Flexible Probe Probe Termination ➀ Optional Weight Probe Locking Set Screw ➀ Optional Mounting Bracket (Used w/ Insulated Probes) ➁ Tank Bracket Connection x Attach the weight or anchor assembly to the end of the probe. Insert the probe through the vessel’s mounting connection, and feed the cable into the vessel. Do not allow the probe to scrape against the connection threads. ➄➈ Clamp ➄➈ Teflon Retaining Bushing y Secure the anchor assembly (if used), to the bottom of the vessel. z Apply thread sealant to the mounting nut. Screw the mounting nut into the mounting connection until tight. { Remove the Mylar housing insulator located over the clamp. DO NOT DISCARD. | Loosen both socket head screws from the clamp. Pull the clamp and Teflon retaining bushing off of the probe. } While holding on to the probe cable, loosen the upper packing gland nut. DO NOT ALLOW THE PROBE CABLE TO FALL INTO THE VESSEL. ~ Pull the excess cable up through the packing gland nut until the cable is taut. Tighten the packing gland nut.  Cut the cable 1.35" (34 mm) above the packing gland nut and strip off 1.25" (32 mm) of insulation. € Slide the Teflon retaining bushing onto the cable and seat it into the packing gland nut. Slide the clamp onto the cable and seat it against the Teflon retaining bushing. y y  Tighten both socket head screws, on the clamp, to approximately 35 in/lbs of torque. Slip the Mylar insulator over the clamp. 2.4.3 Installing the Transmitter x Loosen screw on top of the probe and attach white wire to probe, making sure that spade lug is at a 90° upward angle. Tighten probe screw securely. y Slide white wire through the adaptor while placing the transmitter on the probe. Tighten the connection by using the flats on the adaptor. x 90° Bend 9 50-660 Kotron Model 805 Smart RF Level Transmitter 2.5 Wiring Black (-) Red (+) Caution: The Kotron Model 805 transmitter operates at voltages of 11–36 VDC (GP) and 11–28.6 VDC (IS). Higher voltages will damage the transmitter. (+) (-) All wiring between the power supply and the Model 805 transmitter should be made using 18–22 AWG shielded twisted pair instrument cable. Within the transmitter enclosure, connections are made to the terminal strip and the ground connections. The directions for wiring the Model 805 transmitter depend on the application: • General Purpose or Non-incendive (Cl I, Div. 2) • Intrinsically Safe WARNING! Explosion hazard. Do not disconnect equipment unless power has been switched off or the area is known to be safe. 2.5.1 General Purpose or Non-incendive (Cl I, Div. 2) A general purpose installation does not have flammable media present. Areas rated non-incendive (Cl I, Div. 2) have flammable media present only under abnormal conditions. No special electrical connections are required. If flammable media is contained in the vessel, the transmitter must be installed per Cl I, Div. 1 standards of area classification. 1. 2. 3. 4. 5. 6. To install General Purpose or Non-incendive wiring: Remove the cover to the wiring compartment of the transmitter. Install the conduit plug in the unused opening. Install a conduit fitting and pull the supply wires. Connect shield to an earth ground at power supply and leave floating at the transmitter. Connect an earth ground wire to the nearest green ground screw. (Not shown in illustration.) Connect the positive supply wire to the (+) terminal and the negative supply wire to the (-) terminal. Replace the cover to the wiring compartment of the transmitter. 2.5.2 Intrinsically Safe An intrinsically safe (IS) installation potentially has flammable media present. An approved IS barrier must be installed in the nonhazardous (safe) area. See Agency Drawing – Intrinsically Safe Installation, Section 3.4.4. 50-660 Kotron Model 805 Smart RF Level Transmitter 10 1. 2. 3. 4. 5. 6. 7. To install Intrinsically Safe wiring: Make sure the IS barrier is properly installed in the safe area (refer to local plant or facility procedures). Complete the wiring from the barrier to the Model 805 transmitter. See Agency Specifications – Intrinsically Safe Installations, Section 3.4.1. Remove the cover to the wiring compartment of the transmitter. Install the conduit plug in the unused opening. Install a conduit fitting and pull the supply wires. Connect shield to an earth ground at power supply and leave floating at the transmitter. Connect an earth ground wire to the nearest green ground screw. (Not shown in illustration.) Connect the positive supply wire to the (+) terminal and the negative supply wire to the (-) terminal. Replace the cover to the wiring compartment of the transmitter. Configuring and Calibrating the Transmitter (LCD version) Before configuring the Model 805 transmitter, collect the operating parameters information. Then, power-up the transmitter. Information on configuring the transmitter using a HART communicator is given in Configuration Using HART, Section 2.7. 2.6 2.6.1 Operating Parameters Some key information is needed to calibrate the Model 805 transmitter. Complete the configuration information table. See Configuration Information, Section 1.1.2. 2.6.2 LCD Transmitter Display and Keypad The Model 805 LCD transmitter has a liquid-crystal display (LCD) capable of showing two lines of 8 characters each. Transmitter measurements and configuration menu screens are shown on the LCD. The transmitter default display is the measurement screen. It cycles every 5 seconds to display LEVEL, %OUTPUT, and LOOP information. The transmitter defaults to this display after 5 minutes if no keystrokes are sensed. The keypad has three arrows used to scroll through the displays and to calibrate the transmitter – the Up ( ) or Down ( ) Arrow keys and the Enter ( ) key. Either the Lo Cal or Hi Cal point levels can be entered first. It is not necessary to do the Lo Cal first. In addition, the 4 mA and 20 mA setpoints can be entered for either DIRECT action or REVERSE action as desired. 11 50-660 Kotron Model 805 Smart RF Level Transmitter Á Á Á Arrows Function in Display Mode Function in Configuration Mode Increases or decreases the value displayed or moves to another choice. NOTE: Hold arrow key for rapid scrolling. Up and Down Moves forward and backward in the configuration program from one display to another. Á Á Enter Enters the configuration mode Accepts a value and moves (noted by an exclamation point to the next step of the as the last character in the top configuration program. display line). 2.6.3 Password Protection (Default = 0) NOTE: If the password is not known, the menu item New Password displays an encrypted value representing the present password. Call the factory with this encrypted value to determine the present password. 2.6.4 LCD Menu: Step-By-Step Procedure 50-660 Kotron Model 805 Smart RF Level Transmitter Á The Model 805 transmitter includes optional password protection to restrict access to certain portions of the menu structure that affect the operation of the system. The password can be changed to any numerical value up to 255. The password is required whenever configuration values are changed. The default password installed in the transmitter at the factory is 0. The last step in the configuration menu provides the option to enter a new password. With 0 as the password, the transmitter is no longer password protected and any value in the menu can be altered without entering a confirming password. The following table provides a complete explanation of the software menus displayed by the Model 805 transmitter. Use this table as a step-by-step guide to configure the transmitter. The first column presents the menus shown on the transmitter display. The displays are in the order they would appear if the arrow keys were used to scroll through the menu. The numbers are not shown on the display. They are provided as a reference. The second column provides the actions to take when configuring the transmitter. Additional information or an explanation of an action is given in the third column. 12 Display Action Comment 1 *Level* *%Output* *Loop* Transmitter Display Transmitter Display Transmitter Display Transmitter Display Select units for level measurement display. Enter level value for the lower calibration point. Transmitter Display Enter level value for the higher calibration point. Transmitter Display Enter the level value for the 4 mA point. Enter the level value for the 20 mA point. Enter damping factor. Enter the desired loop current in presence of a fault. Enter HART poll address. Trim loop current to 4.00 mA. Trim loop current to 20.00 mA. RUN MODE Transmitter default display. Level, % Output, and Loop values cycle every 5 seconds (two seconds each value). Level measurement in cm or in. Level as percentage of loop current (20 mA) span. Loop current output. lu = cm or in. Use Up and Down keys to set reading to present level of medium in vessel. See Section 1.4. Measured capacitance at low calibration point. Move the level in the tank. Use Up and Down keys to set reading to present level of medium in vessel. See Section 1.4. Measured capacitance at high calibration point. Use Up and Down keys to set reading to level corresponding to 4 mA loop current. Use Up and Down keys to set reading to level corresponding to 20 mA loop current. Choose the damping factor (1–45 sec) for smoothing the level/output/loop displays. Select 22 mA, 3.6 mA or Hold. (3.6 mA is not valid if unit includes both digital display and HART) Select a HART poll address (0–15). Enter 0 for a single transmitter installation. With a meter in the loop, use Up and Down keys to adjust current to 4.00 mA. With a meter in the loop, use Up and Down keys to adjust current to 20.00 mA. Use Up and Down keys to set loop current to a desired value (3.5–22.0 mA) for testing. Measured capacitance at present level of medium in vessel. Internal timing count with known capacitance in circuit (factory diagnostic). Internal timing count with probe disconnected (factory diagnostic). Internal timing count at present level of medium in vessel (factory diagnostic). Resets all configuration parameters to factory default values. Shows version number of firmware. Use Up and Down keys to select desired value (0–255). 2 Level xx.x lu %Output xx.x% Loop xx.xx mA Units lu Lo Cal xxx.x lu Lo Cap xxxx pF Hi Cal xxx.x lu Hi Cap xxxx pF Set 4mA xxx.x lu Set 20mA xxx.x lu Damping xx sec Fault Choice Poll Adr xx Trim 4 xxx Trim 20 xxxx 3 4 5 6 7 CALIBRATION/CONFIGURATION 8 9 10 11 12 13 14 15 16 17 Loop Tst xx.x mA Prb Rdg xxxx pF Osc Tst xxxx tk Opn Prb xxxx tk # Ticks xxxxx tk Reinit xx Ver n.nAa Enter test value of loop current Transmitter Display Transmitter Display Transmitter Display Transmitter Display Select Yes to reinitialize all values Transmitter Display Enter new password 18 19 DIAGNOSTICS 20 21 22 23 24 New Pass xxx 13 50-660 Kotron Model 805 Smart RF Level Transmitter 2.7 Configuring and Calibrating the Transmitter Using HART A HART (Highway Addressable Remote Transducer) remote unit, such as a HART 275 handheld communicator, can be used to provide a communication link to the Model 805 transmitter. When connected to the control loop, the same system measurement readings shown on the transmitter are shown on the communicator. In addition, the communicator can be used to configure the transmitter. The HART communicator may need to be updated to include the Model 805 software (Device Descriptors). Contact your local HART Service Center for additional information. - + 2.7.1 Connections Junction A HART communicator can be operated from a remote location by connecting to a remote junction or by connecting directly to the terminal block in the electronics housing of the Model 805 transmitter. HART uses the Bell 202 frequency shift key technique of high-frequency digital signals. It operates on the 4–20 mA loop and requires 250 W of minimum load resistance. A typical connection between a communicator and the Model 805 transmitter is illustrated. 2.7.2 HART Display Menu R L > 250 - + Control Room Display Power Supply Current Meter A typical HART communicator display is an 8-line by 21-character LCD. When connected, the top line of each online menu displays the model (Model 805) and its tag number or address. Usually the bottom line of each menu is reserved for software-defined function keys (F1–F4). For detailed operating information, refer to the instruction manual provided with the HART communicator. The Model 805 transmitter online menu tree is shown in the following illustration. Open the menu by pressing the alphanumeric key 1, Device Setup, to display the secondlevel menu. 2.7.3 HART Device Description (DD) Device Version 1 (Dev v1), Device Description 2 (DD v2) was registered with HART Communication Foundation in May, 1999 and is available on the CD-ROM 1999–2 issued in July, 1999. 50-660 Kotron Model 805 Smart RF Level Transmitter 14 2.7.4 HART Menu 1 2 3 4 Device Setup Level % Level Output Loop 1 Calibration 1 2 3 4 5 6 7 8 Units Empty Calibration Full Calibration 4 mA Set Point 20 mA Set Point Damping Fault State Date/Time/Initials 2 Basic Setup 1 2 3 4 5 6 7 Tag Descriptor Date Message Final Asmbly Num Poll Address New Password 3 Advanced Setup/ Configuration 1 2 3 4 5 6 7 1 2 3 4 5 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Adjust 4 mA Trim Adjust 20mA Trim 4mA Trim Value 20mA Trim Value Enter Password Set Magnetrol S/N Set Dev ID Number Loop Test Error Codes Probe Reading Cap at Empty Cal Cap at Full Cal Model Manufacturer Dev id Tag Descriptor Date Message Units Cap at Empty Cal Cap at Full Cal 4 mA Set Point 20 mA Set Point Damping Fault State Date/Time/Initials FinalAsmbly Num Universal Rev Fld Dev Rev Software Rev Poll Address Num Req Preams Firmware Version 4 Diagnostics 1 2 3 4 5 3.6 mA 4 mA 20 mA 22 mA Other 5 Review 15 50-660 Kotron Model 805 Smart RF Level Transmitter 3.0 + – + – Test Current Meter Current Meter Power Supply 24 Vdc Reference Information This section presents an overview of the operation of the Kotron Model 805 transmitter, information on troubleshooting common problems, listings of agency approvals, lists of replacement and recommended spare parts, and detailed physical, functional, and performance specifications. 3.1 Description Model 805 is a two wire, 24 VDC, level transmitter based on the concept of RF Capacitance. The Model 805 electronics are housed in an ergonomic housing comprised of two tandem compartments angled at 45 degrees for ease of wiring and calibration. These two compartments connect via an explosion-proof and watertight feed-through. 3.2 AC Theory of Operation RF capacitance electronic level measurement utilizes the same fundamentals as any electronic capacitor (Figure A). A capacitor is formed when an AC signal is applied across two conductive plates separated by an insulating medium, or dielectric. The value of a capacitor is determined by the: 1. Area of the conductive plates (A); 2. Distance between the plates (D), and; 3. Dielectric of the insulating medium between the plates (E). Refer to Figure A. Conductive Plate Insulating Medium Conductive Plate Capacitance = EA/D (The AC frequency is fixed as part of the design.) Figure A 50-660 Kotron Model 805 Smart RF Level Transmitter 16 Capacitance is measured in Farads. The value we utilize in industrial measurement is an extremely small unit called a pico Farad (pF). A pico Farad is one trillionth of a Farad (10-12). Bare metal probe Air Capacitance value increases as the dielectric increases, the plate size increases, or the distance between the plates decreases. In industrial applications (Figure B), the probe is one plate of the capacitor, the tank wall is the other plate (ground reference). The insulating material that separates them is the dielectric. A tank that is empty is actually filled with air that has a dielectric of 1, the baseline of the dielectric scale. All materials have a dielectric higher than air, e.g. oil = 2.5, alcohol = 18, tap water = 80, etc. As a tank is filled with media, the air (dielectric = 1) is being displaced by the media having a higher dielectric; consequently, the amount of capacitance being generated between the probe and the tank wall increases. 3.3 Troubleshooting The Model 805 transmitter is designed and built for trouble-free operation over a wide range of operating conditions. Common transmitter problems are discussed in terms of their symptoms and recommended corrective actions. In addition, information on how to handle material build-up on the probe is provided in this section. WARNING! Explosion hazard. Do not connect or disconnect equipment unless power has been switched off or the area is known to be safe. Metal tank wall (ground reference) Non-conductive (insulating) medium Figure B 17 50-660 Kotron Model 805 Smart RF Level Transmitter 3.3.1 Troubleshooting System Problems Symptom OUTPUT signal always at 4 mA. LEVEL, % OUTPUT and LOOP values are all inaccurate. LEVEL readings are repeatable but consistently high or low from actual by a fixed amount. LEVEL, % OUTPUT and LOOP values fluctuate. LOOP value jittery, usually in tenths or hundredths digit. HART device only: handheld will only read Universal Commands. HART device only; reads Product information (e.g., Mfgs. ID, Device #, Serial #, etc.) but will not read any process variables. Problem HART Poll address is not 0. Basic configuration data is questionable. Configuration data does not accurately match tank height. Turbulence. Factory settings corrupted. Most current Device Descriptors (DDs) are not installed in handheld Early HART software does not account for Mfgs. ID #’s greater than 63. Magnetrol’s ID is 86. Solution Change HART Poll Address to 0. See Secion 2.6.4, Step 14. Check values and recalibrate if necessary (either or both points). Recalibrate if necessary. Increase the Damping factor until the readings stabilize. Check # of Ticks. If the number is also jittery, consult the Factory. Contact local HART service center for the latest DDs. Contact manufacturer of your HART master software for upgrade. This is a shortcoming of early HART master software. 3.3.2 Error Messages Problem Open probe. Solution Check probe wiring and electronics module connector. Check probe wiring and integrity of insulated probe in conductive liquid. Check connection between boards and replace electronic module if necessary. Measured capacitance > 12,000 pF. Contact factory. Check all Configuration parameters and. recalibrate if necessary. Bad internal state, unexpected condition. Contact factory. Make sure that both Lo Cal and Hi Cal points have been entered. Symptom 805 FAULT (Open) 805 FAULT (Shorted) OSC FAIL (HART error code = 0x40) ABV RNG Shorted probe. Malfunctioning analog board and/or 32 pin connector. Above range. CORRUPT PARAMTRS (HART error code = 0x10) SFWR ERROR Configuration parameters may have been lost. Software error. LEVEL (Uncal) Unit is not calibrated. 50-660 Kotron Model 805 Smart RF Level Transmitter 18 3.3.3 Troubleshooting Flowchart (LCD version) Start Unit Equipped with Display? No HART Communications OK? Yes Yes No Active HART Display has Text? No Check Voltage at Terminal Board 3 Some problems could be temporarily solved by power cycling the unit. Please call factory if this problem persists. No Voltage? Yes Check Power Supply and Wiring No Yes Negative Voltage? Yes Reverse Wiring No Voltage Above 36 Volts? Yes Call Factory No Faint Display? Yes Voltage < 11V IS or 16V XP? Yes Check Loop Current at terminal Board No No Loop Current Above 23 mA? Remove Electronic Module Loop Current Above 1 mA? Yes Good Display Failure to Operate with Correct Loop Inputs No No Loop Resistance Wrong? No No Yes 2 1 Yes Replace Electronic Module Replace Terminal Board Correct Loop Resistance Reseat Boards. Check Power Supply and Wiring Display Working? Yes Retest 19 50-660 Kotron Model 805 Smart RF Level Transmitter 1 Failure to Operate with Correct Loop Inputs Reseat Boards No Display Working? Yes Retest No Check Loop Current at Terminal Board Loop Current Above 23 mA? Yes Remove Electronic Module Loop Current Above 1 mA? Yes No Replace Electronic Module Replace Terminal Board 2 Good Display Display Working? No Yes Key Board Responds? No Replace Electronic Module Retest Unit Yes Unit has HART? Yes HART Working? No Check Loop Current at Wiring Board Loop Current 22 - 4.0 mA? No Adjust 4 and 20 mA No Yes Yes Address Correct? Unit with Display Communicates No Correct Address Yes 4 Replace Electronic Module 50-660 Kotron Model 805 Smart RF Level Transmitter 20 4 Unit with Display Communicates Call Factory Yes Yes "Software Error?" Corrupt Display Text? Yes Replace Electronic Module "Above Range?" No No "Shorted Probe?" No Error Displayed? Yes "Open Probe?" No "OSC Fail?" Yes Yes Yes No "Corrupt Parameters?" No No "Uncal?" No Yes Yes Check Analog Parameters Check Calibration Parameters No Check Probe and Connectors Analog Loop Correct? No Trim 4–20mA Check Offset and 4–20 mA Set Points Retest No Same Error Message? 3 Active HART Yes Replace Electronic Module Yes No Display Reading Correctly? Yes Call Factory 21 50-660 Kotron Model 805 Smart RF Level Transmitter 3.4 Agency Approvals MODEL APPROVED APPROVAL CATEGORY APPROVAL CLASSES AGENCY FM 805-5XXX-11X Intrinsically Safe 805-5XXX-11X Non-Incendive CSA 805-5XXX-110 Intrinsically Safe 805-5XXX-110 Suitable for: ATEX 805-5XXX-A1X Intrinsically Safe Class I, Div. 1; Groups A, B, C, & D Class II, Div. 1; Groups E, F, & G Class III T4 Ta = +71° C Entity NEMA 4X IP66 Class I, Div. 2; Groups A, B, C, & D Class II, Div. 2; Groups F & G Class III T4 Ta = +71° C NEMA 4X IP66 Class I, Div. 1; Groups A, B, C, & D Class II, Div. 1; Group E, F, & G (insulated probes) (Group G only with bare probe) Class III T4 Ta = +71° C Entity Type 4X Class I, Div. 2; Groups A, B, C, & D Class II, Div. 2; Groups E, F, & G (insulated probes) (Group G only with bare probe) Class III T4 Ta = +71° C Type 4X II 1G EEx ia IIC T6* (-40° to +40° C ambient temp.) II 1G EEx ia IIC T4* (-40° to +80° C ambient temp.) These units have been tested to EN 50081-2 and EN 50082-2 and are in compliance with the EMC Directive 89/336/EEC. *Special conditions for safe use: Because the enclosure of the transmitter is made of aluminum alloy, the transmitter must be installed so, that even in the event of rare incidents, an ignition source due to impact or friction between the enclosure an iron/steel is excluded. Probes with an insulating layer, used in potentially explosive atmosphere with gas, vapor or mist of gas group IIC, may only be used for the measurment of the level of a conductive fluid. 50-660 Kotron Model 805 Smart RF Level Transmitter 22 3.4.1 Agency Specifications – Intrinsically Safe Installation 23 50-660 Kotron Model 805 Smart RF Level Transmitter 3.5 Parts { z y | z x 3.5.1 Replacement Parts Item 1 Description Electronic module includes: Display (English) and HART Display only Terminal board includes: O-ring (neoprene) Housing cover without glass Housing cover with glass Part Number Z31-2809-001 Z31-2809-003 Z30-9106-003 012-2201-237 004-9193-003 036-4410-001 2 3 4 5 50-660 Kotron Model 805 Smart RF Level Transmitter 24 3.6 Specifications 3.6.1 Functional System Design Measurement Principle Input Measured Variable Zero and Range Span Output Type Range Resolution Analog Analog Digital Analog Digital Loop Resistance (maximum) Alarm Damping LCD User Interface Keypad Indication Digital Communication Power (Measured at instrument terminals) General Purpose Intrinsically Safe Housing Material Cable Entry Aluminum A356T6 (< 0.2% copper) 3 RF Capacitance Level, determined by change in capacitance values 0" to 1800" (0 cm to 4572 cm) 5 pF min., 10,000 pF max. 4 to 20 mA with optional HART digital signal 3.8 to 20.5 mA useable 0 to 1800" (0 to 4472 cm) 0.01 mA 0.1" GP/IS-620 Ω @ 24 VDC Adjustable 3.6 mA, (no Display or no HART) 22 mA, HOLD Adjustable 1–45 seconds 3-button menu-driven data entry and system security 2-line x 8-character display HART Version 5.x compatible 11 to 36 VDC 11 to 28.6 VDC ⁄4" NPT, M20, PG13.5, PG16 1200 1000 20 mA 800 Ω 600 620 400 200 24 VDC 0 11 25 50-660 Kotron Model 805 Smart RF Level Transmitter 3.6 Specifications 3.6.1 Functional (continued) Process Conditions Maximum process temperature Œ Maximum process pressure Œ Minimum process pressure Œ Environment Operating temperature Display function operating temperature Storage temperature Humidity Electromagnetic compatibility Installation Orientation Œ Depends on probe selection. See bulletin 50-125 for specifications of available probes. Vertical, top-mounted -40 to +175° F (-40 to +80° C) -5 to +160° F (-20 to +70° C) -40 to +175° F (-40 to +80° C) 0–99%, non-condensing Meets CE Requirements (EN 50081-2, EN 50082-2) +1000° F @ 500 psig (+538° C @ 35 bar) 5000 psig from -500° to +100° F (345 bar from -296° to +38° C) -85° F (-65° C) 3.6.2 Performance Reference conditions Accuracy Resolution Repeatability Linearity Hysteresis Response time Warm up time Temperature effect +20° C (+68° F) ±0.5% of span or 0.1" (whichever is greater) 0.1 pF ±0.1% of span ±0.25% of span ±0.1% of span < 1 s (adjustable via damping)
805-501A-111 价格&库存

很抱歉,暂时无法提供与“805-501A-111”相匹配的价格&库存,您可以联系我们找货

免费人工找货