60W DC-DC Regulated Single Output Converter
Features :
SKA60
series
SPECIFICATION
ORDER NO. DC VOLTAGE CURRENT RANGE RATED POWER OUTPUT LINE REGULATION LOAD REGULATION VOLTAGE ACCURACY SWITCHING FREQUENCY
Note.3 Note.4
2" 2" compact size 2:1 wide input range High efficiency up to 93% 1500VDC I/O isolation Built-in remote ON / OFF control Built-in remote sense Trimming output 10% Comply with CE / FCC without external components Protections: Short circuit / Overload / Input and output Over voltage Cooling by free air convection Six-sided shield metal case 100% burn-in test Low cost / High reliability Output 3.3V available 2 years warranty
SKA60A-05 SKA60B-05 SKA60C-05 SKA60A-12 SKA60B-12 SKA60C-12 SKA60A-15 SKA60B-15 SKA60C-15 5V 1.2 ~ 12A 60W 80mVp-p 100mVp-p 0.5% 0.5% 2.0% 250KHz min. 100uF 12V 0.5 ~ 5A 15V 0.4 ~ 4A
RIPPLE & NOISE (max.) Note.2 60mVp-p
220uF EXTERNAL CAPACITANCE LOAD (max.) 1000uF EXTERNAL TRIM Adj. RANGE(Typ.) 10% A: 9 ~ 18VDC B: 18 ~ 36VDC C: 36 ~ 75VDC VOLTAGE RANGE 91% 90.5% 92% 92% EFFICIENCY (Typ.) INPUT DC CURRENT FILTER REMOTE CONTROL PROTECTION OVER CURRENT PROTECTION SHORT CIRCUIT
(Note. 5)
92.5% 2715mA 120mA
92% 1370mA 60mA
92% 5400mA 160mA
93% 2690mA 120mA
92.5% 1370mA 85mA
Full load 5505mA No load 185mA Pi network
2775mA 120mA
1370mA 60mA
5445mA 160mA
Power ON : R.C ~ -Vin > 2.5VDC or open circuit ; Power OFF : R.C ~ -Vin < 0.5VDC or short Fuse recommended 110% ~ 160% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed All output equipped with short circuit Protection type : Hiccup mode, recovers automatically after fault condition is removed Input(Typ.) A: >20 ~ 25VDC B: >40 ~ 50VDC C: >80 ~ 100VDC input voltage Protection type : Shut down o/p voltage, recovers automatically after fault condition is removed Output(Typ.) 5Vo : 7V ~ 8.95V ; 12Vo : 15V ~ 19.2V ; 15Vo : 18V ~ 23.3V -40 ~ +70 +100 (Refer to "Derating Curve") max. Protection type : Clamp by TVS diode
OVER VOLTAGE WORKING TEMP. CASE TEMP.
20% ~ 90% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY -55 ~ +105 , 10 ~ 95% RH 0.03% / (0 ~ 50 ) TEMP. COEFFICIENT WORKING HUMIDITY VIBRATION WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMC EMI CONDUCTION & RADIATION EMS IMMUNITY DIMENSION WEIGHT 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes I/P-O/P:1.5KVDC I/P-O/P: 100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022 Class A, FCC part 15 Class A without external components Compliance to EN61000-4-2,3,4,5,6,8, light industry level, criteria A 50.8*50.8*11.0 mm or 2"*2"*0.43" inch (L*W*H) 67g
OTHERS
Mechanical Specification
Unit:mm(inch) 50.8 (2.00)
7.62 5.08 7.62 5.08 (0.3) (0.2) (0.3) (0.2)
Pin Configuration
Pin No. Output
1 2 3 4 R.C -Vin +Vin -R.S
Derating Curve
+R.S +Vout -Vout TRIM
Pin No. Output
5 6 7 8
100
5.8 (0.23) 11 (0.43)
4
56
78
50.8 (2.00)
45.7 (1.8)
BOTTOM VIEW 32
5.08 (0.2)
External Output Trimming
2 -Vin +Vout 6 7 LOAD VR VR 3 +Vin TRIM 8 UP DOWN 1M
LOAD (%)
50
1
-Vout
10.16 12.7 (0.4) (0.5)
1.0
(0.04 0.005)
-40
0
25
50 55
70
90
Ta (
TRIMPOT
)
NOTE
1.All parameters are specified at normal input, rated load, 25 70% RH ambient. 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 3.Line regulation is measured from low line to high line at rated load. 4.Load regulation is measured from 10% to 100% rated load. 5.Please prevent the converter from operating in overload or short circuit condition for more than 30 seconds.
File Name:SKA60-SPEC 2012-02-24
很抱歉,暂时无法提供与“SKA60A-05”相匹配的价格&库存,您可以联系我们找货