0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
BxxooXN2S-1W

BxxooXN2S-1W

  • 厂商:

    MICRODC

  • 封装:

  • 描述:

    各系列产品被广泛地应用于工业自动化控制、仪器仪表、通信设备、通讯系统、基站、总 线隔离、电力设备、车载设备、铁路信号、用户电源系统、监控系统、智能楼宇、医疗设备等 行业,还专门针对总线隔离器、网络通信...

  • 数据手册
  • 价格&库存
BxxooXN2S-1W 数据手册
B-XN2S-1WSeries Isolated 1W Single Output DC/DC Converters SELECTION GUIDE 5 5 200 289 5 9 111 5 12 B0515XN2S-1W 5 B0524XN2S-1W MTTF1 (%) Isolation Capacitance (PF) (KHRS) 69 30 3415 260 77 37 3078 83 256 78 33 2205 15 66 250 80 40 1532 5 24 42 248 80 48 900 B1205XN2S-1W 12 5 200 120 69 33 2493 B1209XN2S-1W 12 9 111 116 74 48 2311 B1212XN2S-1W 12 12 83 110 76 55 1780 B1215XN2S-1W 12 15 66 111 75 52 1313 B2405XN2S-1W 24 5 200 60 70 40 201 B2409XN2S-1W 24 9 111 55 75 59 185 B2412XN2S-1W 24 12 83 52 80 78 163 B2415XN2S-1W 24 15 66 52 80 79 136 B4805XN2S-1W 48 5 200 30 70 32 213 B4809XN2S-1W 48 9 111 28 75 50 194 B4812XN2S-1W 48 12 83 26 80 76 164 B4815XN2S-1W I/O isolation voltage 1000VDC Input Current (Rated Load) (MA) B0512XN2S-1W Footprint from 0.69cm2 Output Current (MA) B0509XN2S-1W ◆ Output Voltage (V) B0505XN2S-1W FEATURES Input Voltage (V) Efficiency Order code 48 15 66 26 80 75 140 ◆ Operating Temperature: -40℃~﹢85℃ ◆ High efficiency up to 80% ◆ Fully encapsulated toroidal magnetics ◆ Internal SMD construction ◆ 3 Power density up to 0.85W/cm ◆ No electrolytic or tantalum capacitors ◆ 5V,9V,12V and 15V output ◆ 1. Calculated using MIL-HDBK-217F with nominal input voltage at full load. All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified. No heatsink required ◆ Dual output from a single input rail ◆ UL 94V-0 package material ◆ No external components required ◆ Industry standard pinout ◆ Power sharing on output ◆ Input Characteristics Parameter Conditions MTTF up to 3.4 million hours ◆ ① ② ③ ④ ⑤ ⑥ ⑦ B 05 05 X N2 S -1W ①Product Series ②Input Voltage ③Output Voltage ④Fixed Input ⑤Negation output & pin in the following ⑥SIP Package ⑦Rated Power Max. Units 5 5.5 VDC 10.8 12 13.2 VDC Continuous operation, 15V input 13.5 15 16.5 VDC Continuous operation,24V input 21.6 24 26.4 VDC Continuous operation,48V input Voltage range Typ. 4.5 Continuous operation,12V input MODEL SELECTION Min. Continuous operation,5V input 43.2 48 52.8 VDC 20 40 mA p-p Reflected ripple current APPLICATIONS The B-XN2S-1W series of DC/DC converters is particularly suited to isolating and/or converting DC power rails. The galvanic isolation allows the device to be configured to provide an isolated negative rail in systems where only positive rails exist. The wide temperature range guarantees startup from -40°C and full 1 watt output at 85°C. For lower ripple,refer to output ripple reduction section. Absolute Maximum Ratings Parameter Conditions Lead temperature 1.5mm from case for 10 seconds 300℃ Internal power dissipation 700mW Input voltage V , B05 types 18V Input voltage Vin, B24 types http://www.microdc.cn 15V Input voltage Vin, B15 types MICRODC RESERVES THE COPYRIGHT 7V Input voltage Vin, B12 types 28V Input voltage Vin, B48 types 54V Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646 Page 1 of 4 B-XN2S-1WSeries Output Specifications Parameter Conditions Max. Units Rated Power TA= -40°C to 120°C 1.0 W Rated Power(B24、B48) TA=0°C to 70°C 1.0 W Voltage Set Point Accuracy See tolerance envelope Line regulation High VIN to low VIN 1.2 %% Line regulation(B24、B48) High VIN to low VIN 1.2 %% 10% load to rated load, 5V output types 15 % 10% load to rated load,all other output types 10 % Load regulation(B24、B48) Load regulation(5Vinput、 Min. Typ. 1.0 10% load to rated load, 5V output types 10 % 6.5 7.5 % 10% load to rated load,15V output types 6 7.0 % 10% load to rated load, 5V output types 5.5 10 % 10% load to rated load,12V output types 2.6 3.0 % 10% load to rated load, 15V output types Ripple&Noise(B24、B48) % 9 10% load to rated load,12V output types Load regulation(15V input) 12.5 10% load to rated load, 9V output types 12Vinput) 10 2.3 3.0 % 150 mV p-p BW=DC to 20MHz, all input types BW=DC to 20MHz, 5V output types 20 mV p-p 7 15 mV p-p BW=DC to 20MHz, 12V output types 7.5 15 mV p-p BW=DC to 20MHz, 15V output types Ripple&Noise 10 BW=DC to 20MHz, 9V output types 8 15 mV p-p Isolation Characteristics Parameter Conditions Min. Isolation voltage Flash tested for 1 second 1000 Resistance Viso= 1000VDC Resistance(B24、B48) Viso= 500VDC 10 Conditions Typ. Min. Max. Units VDC 10 GΩ GΩ General Characteristics Parameter Typ. Max. Units 5V input types 140 kHz 15V input types 90 kHz All input types Switching frequency(B24、B48) kHz 12V input types Switching frequency 110 100 kHz Temperature Characteristics Parameter Conditions Min. Specification B05、B12、B15 Specification B24、B48 Storage Max. Units -40 85 ℃ 0 70 ℃ B05、B12、B15 -50 130 ℃ Storage B24、B48 -55 150 ℃ Case temperature rise 0505,1205 33 ℃ 0509,0512,0515,1209,1212,1215 28 ℃ 1505 26 ℃ ambient 1512,1515 17 ℃ Cooling Free air convection above Tolerance envelope O u tp u t P o w e r (W ) Temperature derating graph 5V & 12V Input 24V & 48V Input 7 0° c8 5° c Ambient Temperature ( http://www.microdc.cn Typ. C ) Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646 Page 2 of 4 B-XN2S-1WSeries Technical notes ISOLATION VOLTAGE "Hi Pot Test","Flash Tested","Withstand Voltage","Dielectric Withstand Voltage"&”Isolation Test Voltage" are all terms that relate to the same thing, a test voltage. Applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Professional Power Module B series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1KVDC for 1 second. A question commonly asked is,"What is the continuous voltage that can be applied across the part in normal operation?" For a part holding no specific agency approvals, such as the B series ,both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC.The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier, but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-acssible circuitry according to safety standard requirements. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials. Construction and environment. The B series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing. but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage. This consideration equally applies to agency recognized parts for better than functional isolation where the wire enamel insulation is always supplemented by a further insulation system of physical spacing or barriers. Technical notes Output ripple reduction By using the values of inductance and capacitance stated, the output ripple at the rated load is lowered to 5mV p-p max. Component selection Capacitor: Ceramic chip capacitors are recommended. It is required that the ESR(Equivalent Series Resistance)should be as low as possible.X7R types are recommended. The voltage rating should be at least twice(except for 15V output),the rated output voltage of the DC/DC converter. Inductor: The rated current of the inductor should not be less than of the output of the DC/DC converter. At the rated current, the DC resistance of the inductor should be such that the voltage drop across the inductor is 20MHz. Ripple & Noise Characterisation Method Ripple and noise measurements are performed with the following test configuration. C1 1μF X7R multilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC/DC converter C2 10μF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC/DC converter with an ESR of less than 100mΩ at 100 KHz C3 100nF multilayer ceramic capacitor, general purpose R1 450Ω resistor, carbon fi lm, ±1% tolerance R2 50Ω BNC termination T1 3T of the coax cable through a ferrite toroid RLOAD R3 Resistive load to the maximum power rating of the DC/DC converter. Connections should be made via twisted wires 50Ω resistor, carbon film,±1% Measured values are multiplied by 10 to obtain the specified values. Differential Mode Noise Test Schematic http://www.microdc.cn Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646 Page 3 of 4 B-XN2S-1WSeries OUTLINE DIMENSIONS & FOOTPRINT DETAILS FOOTPRINT DETAILS MECHANICAL DIMENSIONS -4 PIN SIP SIP Package Pin Function +Vin -Vin +Vout -Vout 1 2 3 4 Specifcations can be changed any time without notice. NOTICE:Pin in the following All dimensions in inches ±0.01(mm±0.25mm).All pins on a 0.1(2.54) pitch and within ±0.01(0.25)of true position. 0.01(mm± Weight: 1.48g (DIP)1.30g (SIP) No parallel connection or plug and play. Note: 1. The load shouldn't be less than 10%, otherwise ripple will increase dramatically. 2. Operation under 10% load will not damage the converter; However, they may not meet all specification listed. 3. All specifications measured at Ta=25°C, humidity
BxxooXN2S-1W 价格&库存

很抱歉,暂时无法提供与“BxxooXN2S-1W”相匹配的价格&库存,您可以联系我们找货

免费人工找货