0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
NTExxooX

NTExxooX

  • 厂商:

    MICRODC

  • 封装:

  • 描述:

    各系列产品被广泛地应用于工业自动化控制、仪器仪表、通信设备、通讯系统、基站、总 线隔离、电力设备、车载设备、铁路信号、用户电源系统、监控系统、智能楼宇、医疗设备等 行业,还专门针对总线隔离器、网络通信...

  • 数据手册
  • 价格&库存
NTExxooX 数据手册
NTE-X Series 1W, FIXED INPUT, ISOLATED SINGLE OUTPUT SMD DC-DC CONVERTER SMD SELECTION GUIDE Input Nominal Current (mA) Rated Load NTE0303XMC 3.3 NTE0305XMC NTE0309XMC ◆Short Circuit Protection(automatic recovery) ◆I/O isolation voltage 1000VDC Order code Voltage(VDC) Efficiency Output MTTF1 (VDC) Current (mA) (%.Typ.) pF KHrs 410 3.3 303 81 29 5348 3.3 390 5 200 83 30 3847 3.3 400 9 111 74 34 3134 NTE0312XMC 3.3 400 12 83 76 40 3473 NTE0315XMC 3.3 400 15 66 81 42 2473 NTE0503XMC 5 270 3.3 303 85 31 5515 NTE0505XMC 5 294 5 200 83 33 6857 ◆High efficiency up to 78% NTE0505NXMC 5 260 5 200 86 42 3933 ◆Toroidal magnetics NTE0506XMC 5 278 6 167 83 43 6677 NTE0509XMC 5 267 9 111 85 38 5501 NTE0512XMC 5 260 12 83 74 44 3957 NTE0515XMC 5 256 15 66 78 43 2747 ◆Lead frame technology NTE1205XMC 12 124 5 200 80 50 4683 ◆Multi-layer ceramic capacitors NTE1209XMC 12 114 9 111 80 72 4008 ◆Custom solutions available NTE1212XMC 12 113 12 83 85 89 3121 NTE1215XMC 12 111 15 66 81 100 2316 FEATURES ◆Footprint over pins 1.37cm2 ◆Operating Temperature: -40℃~﹢85℃ ◆Small SMD package with footprint ◆Power density 1.8W/cm3 Voltage Isolation Capacitance 1. Calculated using MIL-HDBK-217FN2 with nominal input voltage at full load. All specifications typical at TA=25℃, nominal input voltage and rated output current unless otherwise specified. MODEL SELECTION NTE①05②05③XMC④ ①Product Series ③Output Voltage ②Input Voltage ④Fixed Input&SMD Package Input Characteristics Parameter Conditions converters with high isolation in a SMD package. With a new package design these Units 2.97 3.3 3.63 VDC 4.5 5 5.5 VDC Continuous operation, 12V input The NTE-X series are miniature,1W DC/DC Max. Continuous operation, 5V input 10.8 12 13.2 VDC 30 APPLICATIONS Typ. Continuous operation, 3.3V input Voltage range Min. 47 mA p-p Typ. Max. Units Start up time Isolation Characteristics are qualified for the higher temperatures requested by lead-free reflow Parameter Conditions Min. Isolation voltage Flash tested for 1 second 1000 VDC Resistance converters Viso= 1000VDC 10 GΩ solder processes. With the small footprint, these converters are the ideal solution for General Characteristics board level power distribution,mainly for Parameter Conditions applications in the industrial and telecom field. Switching frequency All output types Min. Typ. Max. Units 110 kHz For automated SMD production lines the devices can be supplied in standard tape and Absolute Maximum Ratings Parameter Conditions Lead temperature 1.5mm from case for 10 seconds 300℃ Internal power dissipation 600mW Input voltage V , NTE03 types reel package. 5.5V Input voltage Vin, NTE05 types 7V Input voltage Vin, NTE12 types 15V MICRODC RESERVES THE COPYRIGHT http://www.microdc.cn Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646 Page 1 of 6 NTE-X Series Output Specifications Parameter Conditions Rated Power TA=-40°C to 85°C Voltage Set Point See tolerance envelope Line regulation Min. Typ. Max. Units 1.0 W High VIN to low VIN 1.0 1.2 %% 10% load to rated load, 0303XMC& 0503XMC 10 14 % 10% load to rated load, 0505XMC&1205XMC 12.8 15 % 10% load to rated load, 0506XMC 9.2 10 % 10% load to rated load, 0509XMC& 1209XMC 8.3 9.0 % 10% load to rated load, 0512XMC& 1212XMC 6.8 7.5 % 10% load to rated load, 0515XMC& 1215XMC 6.3 7.0 % BW=DC to 20MHz, 3.3V output types, 0305XMC & 0505XMC 40 60 mV p-p Load regulation1 BW=DC to 20MHz, 3.3V output types,0505XMC & 1205XMC 62 85 mV p-p BW=DC to 20MHz, 0506XMC 103 170 mV p-p BW=DC to 20MHz, 0509XMC& 1209XMC 49 75 mV p-p BW=DC to 20MHz, 0512XMC& 1212XMC 39 65 mV p-p BW=DC to 20MHz, 0515XMC& 1215XMC 38 76 mV p-p Typ. Ripple&Noise Note:1、12V input types have typically 3% less load regulation change. Temperature Characteristics Parameter Conditions Min. Max. Units Specification All output types -40 85 ℃ -55 125 ℃ Storage 0305, 0309, 0315 ℃ 43 ℃ 1209, 1212, 1215 Cooling 30 0505, 1205 rise above ambient ℃ 0303, 0312, 0503, 0505, 0509, 0512, 0515 Case temperature 25 40 ℃ Free air convection Technical notes ISOLATION VOLTAGE ‘Hi Pot Test’“Flash Tested’”Withstand Voltage“、 、 、 ‘Proof Voltage”“Dielectric Withstand Voltage'&'Isolation Test Voltage”are all terms that relate to the same thing, a test voltage, applied for a speciffi 、 ed time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Professional Power Module NTE-X series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second. A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?” For a part holding no speciffic agency approvals, such as the NTE-X series, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard requirements. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. The NTE-X series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from speciffied test voltage. This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further insulation system of physical spacing or barriers. Temperature derating graph http://www.microdc.cn Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646 Page 2 of 6 NTE-X Series Application Notes Minimum load The minimum load to meet data sheet speciffication is 10% of the full rated load across the speciffied input voltage range. Lower than 10% minimum loading will result in an increase in output voltage, which may rise to typically double the speciffied output voltage if the output load falls to less than 5%. Capacitive loading and start up Typical start up times for this series, with a typical input voltage rise time of 2.2μs and output capacitance of 10μF, are shown in the table below. The product series will start into a capacitance of 47μF with an increased start time, however, the maximum recommended output capacitance is 10μF. Start-up time Start-up time μs μs NTE0303XMC 437 NTE0506XMC 7200 NTE0305XMC 1359 NTE0509XMC 3146 NTE0309XMC 3435 NTE0512XMC 4960 NTE0312XMC 6590 NTE0515XMC 7740 NTE0315XMC 7625 NTE1205XMC 895 NTE0503XMC 533 NTE1209XMC 2150 NTE0505XMC 1368 NTE1212XMC 3640 NTE0505NXMC 721 NTE1215XMC 7180 Ripple & Noise Characterization Method Ripple and noise measurements are performed with the following test configuration. C1 1μF X7R multilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC/DC converter 10μF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC/DC converter with an ESR of less C2 than 100mΩ at 100 kHz C3 100nF multilayer ceramic capacitor, general purpose R1 450Ω resistor, carbon fi lm, ±1% tolerance R2 50Ω BNC termination T1 3T of the coax cable through a ferrite toroid RLOAD Resistive load to the maximum power rating of the DC/DC converter. Connections should be made via twisted wires Measured values are multiplied by 10 to obtain the specified values. Differential Mode Noise Test Schematic http://www.microdc.cn Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646 Page 3 of 6 NTE-X Series Application Notes Output Ripple Reduction By using the values of inductance and capacitance stated, the output ripple at the rated load is lowered to 5mV p-p max. Component selection Capacitor: It is required that the ESR (Equivalent Series Resistance) should be as low as possible, ceramic types are recommended. The voltage rating should be at least twice (except for 15V output), the rated output voltage of the DC/DC converter. Inductor: The rated current of the inductor should not be less than that of the output of the DC/DC converter. At the rated current, the DC resistance of the inductor should be such that the voltage drop across the inductor is 20MHz. Inductor Capacitor L,μH SMD Through Hole C,μF NTE0303XMC 10 82103C 11R103C 4.7 NTE0305XMC 47 82473C 11R103C 4.7 NTE0309XMC 22 82223C 11R223C 2.2 NTE0312XMC 10 82103C 11R103C 1 NTE0315XMC 47 82473C 11R473C 1 NTE0503XMC 10 82103C 11R103C 4.7 NTE0505XMC 47 82473C 11R473C 4.7 NTE0505NXMC 47 82473C 11R473C 4.7 NTE0506XMC 10 82103C 11R103C 4.7 NTE0509XMC 22 82223C 11R223C 2.2 NTE0512XMC 47 82473C 11R473C 1 NTE0515XMC 47 82473C 11R473C 1 NTE1205XMC 47 82473C 11R473C 4.7 NTE1209XMC 22 82223C 11R223C 2.2 NTE1212XMC 47 82473C 11R473C 1 NTE1215XMC 47 82473C 11R473C 1 Tolerance Envelopes The voltage tolerance envelope shows typical load regulation characteristics for this product series. The tolerance envelope is the maximum output voltage variation due to changes in output loading. http://www.microdc.cn Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646 Page 4 of 6 NTE-X Series OUTLINE DIMENSIONS & FOOTPRINT DETAILS MECHANICAL DIMENSIONS SOLDER PAD DIMENSION Dimensions in [mm], () = Inch Pin pitch tolerances: ±0.13 (±0.005) Other tolerances: ±0.25 (±0.01) PRODUCT ID DESCRIPTION Note: Unit:mm[inch] Pin section tolerances:±0.10mm[±0.004inch] General tolerances:±0.25mm[±0.010inch] Weight: 1.21g FOOTPRINT DETAILS Pin Single 1 -Vin 3 +Vin 5 NA 7 -Vout 8 +Vout 10 NA 12 NA 14 NA TUBE OUTLINE DIMENSIONS NA - Not available for electrical connection. Specifications can be changed any time without notice. No parallel connection or plug and play. Note: Unless otherwise stated all dimensions in mm±0.5 (inches ±0.02). Tube length : 475±2.0 (18.70±0.07). Tube Quantity :35 1. The load shouldn't be less than 10%, otherwise ripple will increase dramatically. 2. Operation under 10% load will not damage the converter; However, they may not meet all specification listed. 3. All specifications measured at Ta=25°C, humidity
NTExxooX 价格&库存

很抱歉,暂时无法提供与“NTExxooX”相匹配的价格&库存,您可以联系我们找货

免费人工找货