0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
M1520P-L55-T

M1520P-L55-T

  • 厂商:

    MICROESYS

  • 封装:

  • 描述:

    M1520P-L55-T - Mercury TM1500P PCB-Mount Digital Encoders Factory Set Resolution to 0.50μm - GSI Gro...

  • 数据手册
  • 价格&库存
M1520P-L55-T 数据手册
Mercury TM 1500P PCB-Mount Digital Encoders Factory Set Resolution to 0.50μm Reflective Linear and Rotary Encoders Resolution Factory Set: Sensor the size of a Dime x4, x8, x20, or x40 Linear: 5μm, 2.5μm, 1.0μm, or 0.50μm Rotary: 6,600 to 655,000 CPR Accuracy Linear: ± 1μm available ± 3μm to ± 5μm standard Rotary: Up to ± 2.1 arc-sec Output A-quad-B and Digital Index Window The Mercury 1500P encoder is a digital output system. Designed for PC board mounting, it is available with linear or rotary scales. Mercury’s space-saving, integrated configuration gives OEM system designers a breakthrough in performance. Imagine what you can do with this! OEMs can now use encoders for closed loop control where it was previously not possible or cost effective. Engineers can achieve dramatic improvements in system speed, throughput, and reliability, while reducing cost, size and weight. The Mercury 1500P series kit encoders make it all possible. The digital output sensors mount directly on your printed circuit board within an EMI shielded module. The low Z height of the sensor, only 5.6mm, opens up exciting design possibilities. Table of Contents System & Sensor pg . 2 Specifications pg 3 -4 Scales pg . 5 - 6 Ordering Information pg. 6 Standard Features • Small PCB mount sensor • Sensor is 5.6mm (H) x 12.7mm (W) x 15.2mm (L) and weighs 2.6g • Resolution: Linear 5, 2.5, 1.0, 0.5µm; Rotary 6,600 to 655,000 CPR • Digital Differential Outputs: A-quad-B and Index window • Bi-directional Index window signal • Index mark at the center or end of the glass scale (linear) O ptional features • Glass scale length or diameter: Linear lengths from 5mm to 2m Rotary diameters from 12mm to 108mm Broader Alignment Tolerances, Increased Standoff Clearance, Smallest Sensor and More Why Mercury Encoders Make It Easier To Design High Performance Into Your Equipment Eliminate the Frustration of Touchy Encoder Alignment Mercury Solves this Problem for Good Fussy alignment is no longer a concern. With Mercury’s patented PurePrecision™ optics, advanced SmartPrecision™ electronics and LED alignment indicators, you can push the sensor against your reference surface, tighten the screws and you’re finished. Try that with brand X or Y. This performance is possible thanks to relaxed alignment tolerances, particularly in the theta Z axis. Mercury offers a ± 2° sweet spot– that’s a 300% improvement over the best competitive encoder. And that will result in dramatic savings in manufacturing costs. No other commercially available encoder is easier to align, easier to use, or easier to integrate into your designs. Theta Z Alignment Tolerance ± 2° ± 0.5° ± 0.006° Mercury Brand Y Brand X Alignment Tolerance Comparison** Z Standoff Y theta X theta Y theta Z Mercury* ± 0.15mm ± 0.20mm for linear _ ± 0.10mm for rotary > 19mm dia. ± 1.0° ± 2.0° ± 2.0° Brand X ± 0.1mm ± 0.1mm unspecified ± 0.1° ± 0.006° Brand Y ± 0.1mm unspecified ± 1.0° ± 1.0° ± 0.5° Mercury vs. Best Competitor Mercury is 50% better Mercury is 100% better Mercury is 100% better Mercury is 300% better *Measured at a constant temperature for one axis at a time with all other axes at their ideal positions. **Based on published specifications Mercury Can Reduce System Size and Cost Mercury’s sensor height is 44% shorter than competitive encoders, making it easy to fit into your design. This reduction can also cut total system weight and cost by allowing the use of smaller motors and stages. Safe system operation is also enhanced thanks to Mercury’s generous standoff clearance– 200% greater than other encoders. And it’s standoff tolerance is 50% greater than the best alternative. This significantly relaxes mechanical system tolerances, while reducing system costs. Standoff Clearance Mercury 2.4mm* ± 0.15mm Brand Y Mechanical Dimension Comparison** Sensor Z height Standoff clearance Standoff tolerance System height Mercury Brand X Brand Y Mercury vs. Best Competitor 8.4mm 23mm 15mm 44% better 2.4mm 0.5mm 0.8mm 200% better ± 0.15mm ± 0.1mm ± 0.1mm 50% better 11.7mm 28.5mm 15.8mm 26% better Brand X 0.8mm ± 0.1mm **Based on published specifications 0.5mm ± 0.1mm * Dimensions shown illustrate encoder system standoff clearance; see Mercury Encoder Interface Drawings for correct design reference surfaces. Note: Mercury 1500P is even smaller at 5.6mm sensor height Page 2 of 5 System Specifications Resolution and Maximum Speed Mercury 1500P systems have factory set interpolation: x4, x8, x20, x40. Below is the table of available resolutions. Linear - 20μm grating pitch Interpolation Resolution Maximum Speed x4 x8 x20 x40 5.000µm/count 2.500µm/count 1.000µm/count 0.500µm/count 7200mm/s 7200mm/s 7200mm/s 7200mm/s R otary - 20μm grating pitch Rotary Glass Scale Diameter Fundamental Resolution Interpolation Below is a table of the available resolutions. 0.472” [12.00mm] 1650 CPR interpolated resolution (CPR) interpolated resolution (arc-sec/count)* interpolated resolution (µrad/count)* maximum speed (RPM) x4 6,600 196.4 952 13090 x4 10,000 129.6 628 8640 x4 16,384 79.1 383 5273 x4 32,768 39.6 191.7 2637 x8 13,200 98.2 476 13090 x8 20,000 64.8 314 8640 x8 32,768 39.6 191.7 5273 x8 65,536 19.78 95.8 2637 x8 131,072 9.89 47.9 1318 x20 33,000 39.2 190.3 13090 x20 50,000 25.9 125.6 8640 x20 81,920 15.82 76.6 5273 x20 163,840 7.92 38.3 2637 x20 327,680 3.96 19.16 1318 x40 66,000 19.64 95.2 13090 x40 100,000 12.96 62.8 8640 x40 163,840 7.91 38.3 5273 x40 327,680 3.96 19.17 2637 x40 655,360 1.978 9.58 1318 0.750” [19.05mm] 2500 CPR interpolated resolution (CPR) interpolated resolution (arc-sec/count)* interpolated resolution (µrad/count)* maximum speed (RPM) 1.250” [31.75mm] 4096 CPR interpolated resolution (CPR) interpolated resolution (arc-sec/count)* interpolated resolution (µrad/count)* maximum speed (RPM) 2.250” [57.15mm] 8192 CPR interpolated resolution (CPR) interpolated resolution (arc-sec/count)* interpolated resolution (µrad/count)* maximum speed (RPM) 4.250” [107.95mm] 16384 CPR x4 interpolated resolution (CPR) 65,536 interpolated resolution (arc-sec/count)* 19.78 interpolated resolution (µrad/count)* 95.8 maximum speed (RPM) 1318 * Resolution values shown are approximate. To calculate exact resolution values, convert from CPR (Counts Per Revolution) to the desired units. Note: Specifications assume XOR function which is available in all standard controllers. All Specifications are subject to change. All data is accurate to the best of our knowledge. MicroE Systems is not responsible for errors. Page 3 of 6 System Specifications System Grating Period 20µm System Resolution 5µm, 2.5µm, 1.00µm, or 0.50µm (linear) Linear Accuracy* Better than ±1µm** available; contact MicroE Better than ±3µm** up to 130mm, ±5µm from 155mm to 1m, ±5µm per meter from 1m to 2m *Maximum peak to peak error over the specified movement when compared to a NIST-traceable laser interferometer standard, used at room temperature and with MicroE interpolation electronics. **Or +/- one quadrature count, whichever error value is greater. Mercury 1500P Outputs 10-pin interface PIN 1 2 3 4 5 6 7 8 9 10 FUNCTION BB+ Sin + * Cos + * + 5 V DC Index Window + Index Window A+ AGround Rotary Accuracy* Scale O.D. 12.00mm 19.05mm 31.75mm 57.15mm 107.95mm Microradians** ±100 ±63 ±38 ±19 ±10 Arc-Seconds** ±21 ±13 ±7.8 ±3.9 ±2.1 *Based on ideal scale mounting concentricity **Or +/- one quadrature count, whichever error value is greater. * Analog outputs are for sensor alignment only. Output Signals** Sensor Size W: L: H: 12.70mm 15.24mm 5.59mm 0.500" 0.600" 0.220" Pins 8 & 9 Pins 2 & 1 A B Quadrature TTL Operating and Electrical Specifications Power Supply Temperature Operating: Storage: Humidity: Shock: Sensor Weight: 5VDC ±5% @ 33mA1 Resolution 0 to 70°C -20 to 70°C 10 - 90% RH non-condensing 1500G 0.5 ms half sine (Sensor) 2.6g Index Window 20µm Typical Pins 6 & 7 5VDC ** Inverse signals not shown for clarity. 1 Note: a voltage regulator on the customer’s printed circuit board, such as Analog Devices’ ADP 3334 or equivalent, is recommended at the 5V input to the encoder for maximum reliability. Alignment Signals 20µm Pins 3 & 4 800mVp-p ± 25% on a 1.7V DC offset. Mechanical Information - Sensor .126 3.21 PI N 1 .050 1.28 PIN SP ACING PI N 5 90° .600 15.24 .069 1.75 2X 0-80UNC-2B THRU. .295 7.49 .344 8.75 .500 12.70 .148 3.76 .162 4.11 .220 5.59 .330 8.38 PI N 10 .183 4.65 PI N 6 .096 2.44 4X R.047 1.19 .348 8.85 All Specifications are subject to change. All data is accurate to the best of our knowledge. MicroE Systems is not responsible for errors. Page 4 of 6 Scale Specifications Standard and Customized Scales MicroE Systems offers a wide array of chrome on glass scales for the highest accuracy and best thermal stability. Easy to install, standard linear and rotary scales meet most application requirements. Customized linear, rotary, and rotary segment scales are available where needed. All scales include an optical index. Mercury's glass scales save time by eliminating motion system calibrations or linearity corrections required by other encoders, and provide better thermal stability than metal tape scales. Options include: • Standard linear: 18mm - 2m • Standard rotary: 12mm - 107.95mm diameter, with or without hubs • Custom linear*: special lengths, widths, thickness, index mark locations and special low CTE materials • Custom rotary*: special ID's, OD's (up to 304.8mm), index mark outside the main track and special low CTE materials • Mounting of hubs for rotary scales: MicroE Systems can mount and align standard, custom, or customer-supplied hubs • Rotary segments*: any angle range; wide range of radius values *Custom scales or rotary segments are available in OEM quantities. Contact your local MicroE Systems sales office. Standard Short Linear Scales 130mm and Shorter Key: inches[mm] 0.036 [0.9] Scale Length Measured Length is always 5 mm less then total length 0.250 [6.35] End Index Center Index Model Scale Length Measured Length L18 0.709 [18] 0.512 [13] L30 1.181 [30] 0.984 [25] L55 2.165 [55] 1.969 [50] ±3µm standard ±1µm available Material Soda lime glass Typical CTE 8ppm/°C Index Center or End L80 L105 L130 3.150 [80] 4.134 [105] 5.118 [130] 2.953 [75] 3.937 [100] 4.921 [125] Specifications Accuracy Custom scales available Standard Long Linear Scales 1 55mm and Longer Key: inches[mm] 0.098 [2.5] Scale Length Measured Length is always 5 mm less then total length 0.787 [20.00] Center Index Specifications Accuracy Material Typical CTE Index End Index ±5 µm 1m Soda lime glass 8ppm/°C Center or End Model Scale length Measured length L155 6.102 [155] 5.906 [150] L225 8.858 [225] 8.661 [220] L325 12.795 [325] 12.598 [320] L425 16.732 [425] 16.535 [420] L525 20.669 [525] 20.472 [520] L1025 L2025 40.354 [1025] 79.724 [2025] 40.157 [1020] 79.528 [2020] Custom scales available All Specifications are subject to change. All data is accurate to the best of our knowledge. MicroE Systems is not responsible for errors. Page 5 of 6 Standard Rotary Scales HUB THICKNESS SCALE PATTERN SCALE O.D. HUB I.D. MOUNTING HOLES OPTICAL DIAMETER Specifications Material Typical CTE Soda lime glass 8ppm/°C Key: inches[mm] Model No. Scale Outer Diameter Scale Inner Diameter Optical Diameter Hub Inner Diameter +.0005/-0.0000 Hub Thickness Fundamental CPR R1206 R1910 R3213 R5725 R10851 0.472 [12.00] 0.750 [19.05] 1.250 [31.75] 2.250 [57.15] 4.250 [107.95] 0.250 [6.35] 0.375 [9.52] 0.500 [12.70] 1.000 [25.40] 2.000 [50.80] 0.413 [10.50] 0.627 [15.92] 1.027 [26.08] 2.053 [52.15] 4.106 [104.30] 0.1253 [3.18] 0.1253 [3.183] 0.2503 [6.358] 0.5003 [12.708] 1.0003 [25.408] 0.040 [1.02] 0.040 [1.02] 0.050 [1.27] 0.060 [1.52] 0.080 [2.03] 1650 2500 4096 8192 16384 Custom scales available How to Order Mercury 1500P Encoder Systems To specify your Mercury encoder with the desired scale, consult the chart below to create the correct part number for your order. Call MicroE Systems’ Rapid Customer Response team for more information at [781] 266-5700. Example (linear): M1540P-L55-C1 (rotary): M1540P-R3213-HB M15xxP – Scale Model – Scale Mounting Lxxx or Rxxxx For Linear Scales: T = Tape Mounting C1 = 3 scale clamps* C2 = 10 scale clamps** Hubs for Rotary Scales: NH = No hub HE = for R1206 HA = for R1910 HB = for R3213 HC = for R5725 HD = for R10851 M1504P = 4x interpolation M1508P = 8x M1520P = 20x M1540P = 40x * 3 clamps come standard with linear scales up to 130mm ** 10 clamps come standard with linear scales 155mm or longer All Specifications are subject to change. All data is accurate to the best of our knowledge. MicroE Systems is not responsible for errors. DS-M1500P Rev 1 © 2008 MicroE Systems MicroE Systems – World Headquarters: 125 Middlesex Turnpike • Bedford • MA 01730 www.microesys.com • info@microesys.com • T. [781]-266-5700 • F. [781]-266-5112 Page 6 of 6
M1520P-L55-T 价格&库存

很抱歉,暂时无法提供与“M1520P-L55-T”相匹配的价格&库存,您可以联系我们找货

免费人工找货