WRB1205YMD-6W

WRB1205YMD-6W

  • 厂商:

    MORNSUN(金升阳)

  • 封装:

  • 描述:

    WRB1205YMD-6W - DUAL/SINGLE OUTPUT DC-DC CONVERTER - MORNSUN Science& Technology Ltd.

  • 数据手册
  • 价格&库存
WRB1205YMD-6W 数据手册
WRA_YMD-6W & WRB_YMD-6W Series 6W, WIDE INPUT ISOLATED & REGULATED DUAL/SINGLE OUTPUT DC-DC CONVERTER m ulti-country patent protection RoHS F EATURES Efficiency up to 86% DIP Package Operating Temperature: -40°C to +85°C 1.5KVDC Isolation Metal Case Package No Heat sink Required Industry Standard Pin out MTBF>1,000,000 hours RoHS Compliance PRODUCT PROGRAM I nput P art Number W RA0505YMD-6W W RA0512YMD-6W W RA0515YMD-6W W RB0505YMD-6W W RB0512YMD-6W W RB0515YMD-6W W RA1205YMD-6W W RA1212YMD-6W W RA1215YMD-6W W RA1224YMD-6W W RB1205YMD-6W W RB1212YMD-6W W RB1215YMD-6W W RB1224YMD-6W W RA2405YMD-6W W RA2412YMD-6W W RA2415YMD-6W W RA2424YMD-6W W RB2403YMD-6W W RB2405YMD-6W W RB2412YMD-6W W RB2415YMD-6W W RB2424YMD-6W W RA4805YMD-6W W RA4812YMD-6W W RA4815YMD-6W W RA4824YMD-6W W RB4803YMD-6W W RB4805YMD-6W 48 36-72 80 24 18-36 40 12 9-18 20 5 4.5-9 11 Voltage (VDC) Nominal Range Max* Voltage (VDC) ±5 ±12 ±15 5 12 15 ±5 ±12 ±15 ±24 5 12 15 24 ±5 ±12 ±15 ±24 3.3 5 12 15 24 ±5 ±12 ±15 ±24 3.3 5 12 15 24 Output Current (mA) M ax ±600 ±250 ±200 1200 500 400 ±600 ±250 ±200 ±125 1200 500 400 250 ±600 ±250 ±200 ±125 1500 1200 500 400 250 ±600 ±250 ±200 ±125 1500 1200 500 400 250 Min ±60 ±25 ±20 120 50 40 ±60 ±25 ±20 ±13 120 50 40 25 ±60 ±25 ±20 ±13 150 120 50 40 25 ±60 ±25 ±20 ±13 150 120 50 40 25 76 80 82 76 80 82 79 82 84 82 79 82 84 82 81 84 86 84 78 80 84 86 85 80 84 85 86 78 80 84 86 85 Efficiency (%, Typ) APPLICATIONS The WRA_YMD-6W/WRB_YMD-6W Series are specially designed for applications where a wide range input voltage power supplies are isolated from the input power supply in a distributed power supply system on a circuit board. These products apply to: 1) Where the voltage of the input power supply is wide range (voltage range ≤2:1); 2) Where isolation is necessary between input and output (Isolation voltage ≤1500VDC); 3) Where the regulation of the output voltage and the output ripple noise are dem anded. MODEL SELECTION W RB4812YMD-6W W RB4815YMD-6W W RB4824YMD-6W WRA2415YMD-6W Rated Power Package Style Output Voltage Input Voltage Product Series *Input voltage can’t exceed this value, or will cause the permanent damage. Note: The load shouldn't be less than 10%, otherwise ripple will increase dramatically. Operation under 10% load will not damage the converter; However, they may not meet all specification listed. OUTPUT SPECIFICATION I tem Output Power Positive Voltage Accuracy Negative Voltage Accuracy Load Regulation Test Conditions See above products program Refer to recommended circuit Refer to recommended circuit From 10% To 100% load Refer to recommended circuit 20MHz bandwidth 20MHz bandwidth 100% load, nominal Input voltage Min 0.6 ±1 ±3 ±0.5 ±0.2 0.02 20 50 300 50 100 Typ Max 6 ±3 ±5 ±1* ±0.5 %/° C m Vp-p KHz % Units W M ORNSUN Science & Technology co.,Ltd. Address: 2th floor 6th building, Huangzhou Industrial District, Guangzhou, China Tel: 86-20-38601850 Fax: 86-20-38601272 Http://www.mornsun-power.com Line Regulation(at full load) Input voltage from low to high Temperature Drift(Vout) Ripple** Noise** Switching Frequency * Dual output models unbalanced load: ±5%. * * Test ripple and noise by “parallel cable” method. See detailed operation instructions at Testing of Power Converter section, application notes. MORNSUN reserves the copyright Specifications subject to change without notice. WRA_YMD-6W & WRB_YMD-6W A/2-2008 Page 1 of 2 COMMON SPECIFICATIONS I tem Storage Humidity Range Operating temperature Storage Temperature Lead Temperature Temp. Rise at Full Load I solation voltage I solation resistance I solation capacitance No-load power consumption Cooling Short Circuit Protection Case Material MTBF W eight 1000 15 Tested for 1 minute and 1mA max Test at 500VDC Input/Output 1500 1000 100 500 Free Air Convection Continuous, automatic recovery Aluminium alloy K hours g 1.5mm from case for 10 seconds 40 VDC MΩ pF mW -40 -55 Test Conditions Min Typ Max 95 85 125 300 °C Units % Recommended Circuit All the WRA_YMD-6W & WRB_YMD-6W Series have been tested according to the following recommended testing circuit before leaving factory. This series should be tested under load. Never be tested under no load (see Figure 1). Dual Output Vin Cin +Vout DC DC 0V -Vout GND Single Output Vin Ci n +Vout DC DC 0V GND (Figure 1) If you want to further decrease the input/output ripple, you can increase capacitance properly or choose capacitors with low ESR. However, the capacitance of the output filter capacitor must be proper. If the capacitance is too big, a startup problem might arise. For every channel of output, provided the safe and reliable operation is ensured, the greatest capacitance of its filter capacitor sees (Table 1). Cin: 5V&12V 24V&48V 100μF 10μF-47μF General: Note: 1. All specifications measured at TA=25°C, humidity
WRB1205YMD-6W 价格&库存

很抱歉,暂时无法提供与“WRB1205YMD-6W”相匹配的价格&库存,您可以联系我们找货

免费人工找货