0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
A504ERW

A504ERW

  • 厂商:

    MPD

  • 封装:

  • 描述:

    A504ERW - Low Cost, Wide Input, 5W Single & Dual Output DC/DC Converters - MicroPower Direct, LLC

  • 数据手册
  • 价格&库存
A504ERW 数据手册
A500ERW Series Low Cost, Wide Input, 5W Single & Dual Output DC/DC Converters Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Key Features: • 5W Output Power • 2:1 Input Voltage Range • 1,500 VDC Isolation • Compact DIP Case • Single & Dual Outputs • 1.0 MH MTBF • Industry Standard Pin-Out • Low Cost Input Parameter Input Start Voltage Input Filter Reverse Polarity Input Current Short Circuit Input Power Conditions Min. 12 VDC Input 4.5 24 VDC Input 8.0 π (Pi) Filter Typ. 6.0 12.0 Max. 8.0 16.0 1.0 3,000 Max. ±1.0 ±2.0 ±0.3 ±1.0 75 100 15 300 ±6.0 ±0.02 Units VDC 1,000 Conditions Dual Output , Balanced Loads Vin = Min to Max Iout = 20% to 100% Over Line, Load & Temp. 120 25% Load Step Change 150 ±2.0 ±0.01 Continuous (Autorecovery) Min. 1,500 1,000 Typ. Min. Typ. ±0.5 ±0.5 ±0.1 ±0.3 50 A mW Units % % % % mV P - P mV P - P mV rms % µSec % %/ºC Output Parameter Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation Ripple & Noise (20 MHz) (Note 1) Ripple & Noise (20 MHz) Ripple & Noise (20 MHz) Output Power Protection Transient Recovery Time (Note 2) Transient Response Deviation Temperature Coefficient Output Short Circuit General Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency Conditions 60 Seconds 500 VDC 100 kHz, 1V Max. Units VDC MΩ pF kHz Units ºC ºC ºC % RoHS Compliant 380 300 500 Environmental Parameter Operating Temperature Range Operating Temperature Range Storage Temperature Range Cooling Humidity Conditions Min. Typ. -40 +25 -40 -40 Free Air Convection RH, Non-condensing Ambient Case Max. +71 +90 +125 95 MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Physical Case Size Case Material Weight 1.25 x 0.80 x 0.40 Inches (31.8 x 20.3 x 10.2 mm) Non-Conductive Black Plastic (UL94-V0) 0.60 Oz (17g) Conditions MIL HDBK 217F, 25ºC, Gnd Benign Conditions 12 VDC Input 24 VDC Input 1.5mm From Case For 10 Sec All Models Min. Typ. 1.0 Typ. Max. Units MHours Units VDC ºC mW Reliability Specifications Parameter MTBF Absolute Maximum Ratings Parameter Input Voltage Surge (1 Sec) Lead Temperature Internal Power Dissipation Min. -0.7 -0.7 Max. 25.0 50.0 260 2,500 Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. Model Selection Guide Model Number A501ERW A502ERW A503ERW A504ERW A505ERW A511ERW A512ERW A513ERW A514ERW A515ERW Voltage (VDC) Nominal 12 12 12 12 12 24 24 24 24 24 Range 9.0 - 18.0 9.0 - 18.0 9.0 - 18.0 9.0 - 18.0 9.0 - 18.0 18.0 - 36.0 18.0 - 36.0 18.0 - 36.0 18.0 - 36.0 18.0 - 36.0 Input Current (mA) Full-Load 429 514 595 595 595 209 251 291 291 291 Output Reflected Efficiency Current Ripple Voltage Current (%, Typ) (VDC) (mA, Max) (mA, Min) No-Load Current (mA, Typ) Fuse Rating Slow-Blow (mA) 1,500 1,500 1,500 1,500 1,500 700 700 700 700 700 20 20 20 20 20 5 5 5 5 5 25 25 25 25 25 15 15 15 15 15 3.3 5.0 12.0 ±12.0 ±15.0 3.3 5.0 12.0 ±12.0 ±15.0 1,200.0 1,000.0 500.0 ±250.0 ±200.0 1,200.0 1,000.0 500.0 ±250.0 ±200.0 60.0 50.0 25.0 ±12.5 ±10.0 60.0 50.0 25.0 ±12.5 ±10.0 77 81 84 84 84 79 83 86 86 86 Notes: 1. When measuring output ripple, it is recommended that an external 0.47 µF ceramic capacitor be placed from the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units. For noise sensitive applications, the use of 3.3 µF capacitors will reduce the output ripple. 2. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%. 3. Operation at no-load will not damage these units. However, they may not meet all specifications. 4. Dual output units may be connected to provide a 10 VDC, 24 VDC or 30 VDC output. To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs and float the output common. 5. The converter should be connected to a low ac-impedance source. An input source with a highly inductive impedance may affect the stability of the converter. In applications where the converter output loading is high and input power is supplied over long lines, it may be necessary to use a capacitor on the input to insure start-up. In this case, it is recommended that a low ESR (ESR
A504ERW 价格&库存

很抱歉,暂时无法提供与“A504ERW”相匹配的价格&库存,您可以联系我们找货

免费人工找货