0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
B1022RW

B1022RW

  • 厂商:

    MPD

  • 封装:

  • 描述:

    B1022RW - Compact 1 x 2 Inch 10W Wide Input Range DC/DC Converters - MicroPower Direct, LLC

  • 数据手册
  • 价格&库存
B1022RW 数据手册
B1000RW Series Compact 1 x 2 Inch 10W Wide Input Range DC/DC Converters Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Key Features: ● 10W Output Power ● UL Approved (File E245422) ● 2:1 Input Voltage Range ● 1,500 VDC Isolation ● Meets EN55022 Class “A” ● Compact 1 x 2 Inch Case ● Single & Dual Outputs ● Industry Standard Pin-Out Parameter Input Start Voltage Input Filter Reverse Polarity Input Current Short Circuit Input Power Conditions Min. Typ. Max. 12 VDC Input 8.0 8.5 9.0 24 VDC Input 15.0 17.0 18.0 48 VDC Input 30.0 33.0 36.0 π (Pi) Filter (Complies with EN55022 Class “A”) 2.0 3,500 4,500 Conditions Dual Output , Balanced Loads Vin = Min to Max Iout = 10% to 100% Over Line, Load & Temp. 120 25% Load Step Change Continuous Conditions 60 Seconds Flash Tested For 1 Sec 500 VDC 100 kHz, 1V Min. 1,500 1,650 1,000 260 Conditions Typ. Max. 150 ±2.0 ±0.01 300 ±4.0 ±0.02 Min. Typ. ±0.5 ±0.5 ±0.1 ±0.1 50 Max. ±1.0 ±1.0 ±0.3 ±0.5 75 100 15 Units VDC A mW Units % % % % mV P - P mV P - P mV rms % μSec % %/°C Output Parameter Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation Ripple & Noise (20 MHz) (Note 1) Ripple & Noise (20 MHz) Ripple & Noise (20 MHz) Output Power Protection Transient Recovery Time (Note 2) Transient Response Deviation Temperature Coefficient Output Short Circuit General Parameter Isolation Voltage Isolation Test Voltage Isolation Resistance Isolation Capacitance Switching Frequency Units VDC VDC MΩ pF kHz Units °C °C °C % 120 300 160 340 Max. +71 +90 +125 95 Environmental Parameter Operating Temperature Range Operating Temperature Range Storage Temperature Range Cooling Humidity RFI Conducted EMI Min. Typ. -40 +25 -40 -50 Free Air Convection RH, Non-condensing Six-Side Shielded Metal Case EN55022 Class “A” Ambient Case MicroPower Direct 232 Tosca Drive Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Physical Case Size Case Material Weight 2.0 x 1.0 x 0.40 Inches (50.8 x 25.4 x 10.2 mm) Metal with Non-Conductive Base (UL94-V0) 1.06 Oz (30g) Conditions MIL HDBK 217F, 25°C, Gnd Benign Min. Typ. Max. Units 700 kHours UL 1950, EN 60950, IEC 60950 UL, cUL; File No. E245422 Min. -0.7 -0.7 -0.7 Typ. Max. 25.0 50.0 100.0 260.0 5,000 Units VDC °C mW Reliability Specifications Parameter MTBF Safety Standards Safety Approvals Absolute Maximum Ratings Parameter Input Voltage Surge (1 Sec) Lead Temperature Internal Power Dissipation Conditions 12 VDC Input 24 VDC Input 48 VDC Input 1.5 mm From Case For 10 Sec All Models Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. Model Selection Guide Model Number B1001RW B1002RW B1003RW B1004RW B1005RW B1006RW B1007RW B1008RW B1011RW B1012RW B1013RW B1014RW B1015RW B1016RW B1017RW B1018RW B1021RW B1022RW B1023RW B1024RW B1025RW B1026RW B1027RW B1028RW Notes: 1. When measuring output ripple, it is recommended that an external 0.47 μF ceramic capacitor be placed from the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units. 2. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%. 3. Operation at no-load will not damage these units. However, they may not meet all specifications. 4. Dual output units may be connected to provide a 10 VDC, 24 VDC or 30 VDC output. To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs and float the output common. 5. The converter should be connected to a low ac-impedance source. An input source with a highly inductive impedance may affect the stability of the converter. In applications where the converter output loading is high and input power is supplied over long lines, it may be necessary to use a capacitor on the input to insure start-up. In this case, it is recommended that a low ESR (ESR
B1022RW 价格&库存

很抱歉,暂时无法提供与“B1022RW”相匹配的价格&库存,您可以联系我们找货

免费人工找货