0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
MPM-05T-0505

MPM-05T-0505

  • 厂商:

    MPD

  • 封装:

  • 描述:

    MPM-05T-0505 - Compact, 5W PC Mount Single, Dual & Triple Out AC/DC Power Supplies - MicroPower Dire...

  • 数据手册
  • 价格&库存
MPM-05T-0505 数据手册
MPM-05 Series Compact, 5W PC Mount Single, Dual & Triple Out AC/DC Power Supplies Electrical Specifications Key Features: • 5W Output Power • Universal 85-264 VAC Input • EN 60950 Approved Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Input Voltage Range Input Frequency Conditions Min. Typ. Max. 85 264 120 370 47 63 See Model Selection Guide 115 VAC 10.0 230 VAC 20.0 Meets CISPR Pub. 22/FCC Class B 115 VAC 0.1 230 VAC 0.3 Max. Units VAC VDC Hz A Pk • Single, Dual & Triple Outputs Input Current • Meets EN55022 B Inrush Current • >200 kHour MTBF • Compact PC Mount Case EMI Safety Ground Leakage Current mA Units Output Parameter Output Voltage Output Current Output Voltage Accuracy Line Regulation Load Regulation Ripple & Noise (20 MHz) Hold-Up Time Temperature Coefficient Short Circuit Protection Overload Protection Conditions Min. Typ. See Model Selection Guide See Model Selection Guide ±2.0 ±0.5 See Model Selection Guide 50 115 VAC 20 230 VAC 80 ±0.02 Continuous (Autorecovery) Typ. 110% of Output Power Conditions Input to Output Input to Ground Output to Ground Conducted Electrostatic Discharge (ESD) RF Field Susceptibility Electrical Fast Transients/Bursts On Mains Surge Min. 3,000 1,500 500 Typ. % mV Pk - Pk mSec %/°C General Parameter Isolation Voltage EMI/RFI EMC Compliance Max. Units VAC MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Switching Frequency EN 55022 Level B IEC/EN 61000-4-2 Level 3 IEC/EN61000-4-3 IEC/EN 61000-4-4 Level 3 2 kV IEC/EN 61000-4-5 Level 3 1kV/2 kV 150 kHz Min. -20 Typ. +25 Units °C °C °C % Environmental Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Conditions Max. +70 +90 -25 +105 Free Air Convection (See Derating Curve) RH, Non-condensing 85 Ambient Case Physical Case Size Case Material Weight 1.91 x 1.42 x 0.81 Inches (48.5 x 36.0 x 20.5 mm) Non-Conductive Black Plastic (UL94-V0) 3.77 Oz (107g) Conditions Min. Typ. MIL HDBK 217F, 25°C, Gnd Benign 200 IEN 60950, IEC 60950 IEN 60950, IEC 60950 Max. Units kHours Reliability Specifications Parameter MTBF Safety Standards Safety Approvals, See Note 3 Model Selection Guide Model Number MPM-05S-03 MPM-05S-05 MPM-05S-12 MPM-05S-15 MPM-05S-24 MPM-05D-05 MPM-05D-12 MPM-05D-15 MPM-05T-0505 MPM-05T-0512 MPM-05T-0515 MPM-05T-0524 Input Current (A) 115 VAC 230 VAC 0.12 0.12 0.12 0.12 0.12 0.12 0.12 0.12 0.12 0.12 0.12 0.12 0.07 0.07 0.07 0.07 0.07 0.07 0.07 0.07 0.07 0.07 0.07 0.07 Voltage (VDC) 3.3 5.0 12.0 15.0 24.0 +5.0 +12.0 +15.0 5.0 5.0 5.0 5.0 Output 2 (Vout 2) Output 3 (Vout 3) Output 1 (Vout 1) Current (A) Current (A) Current (A) Efficiency Over Volt. Over Volt. Voltage Voltage (%, Typ) Load Protection (VDC) Load Protection (VDC) Load Typ. Typ. Typ. (VDC) (VDC) Reg. Reg. Reg. 1.00 ±1.0% 6.5 76 1.00 ±1.0% 6.5 76 0.42 ±1.0% 20.0 76 0.33 ±1.0% 20.0 76 0.23 ±1.0% 30.0 76 +0.50 ±2.0% 6.5 -5.0 -0.50 ±2.0% 6.5 76 +0.21 ±2.0% 20.0 -12.0 -0.21 ±2.0% 20.0 76 +0.16 ±2.0% 20.0 -15.0 -0.16 ±2.0% 20.0 76 0.90 ±3.0% 6.5 +5.0 +0.10 ±5.0% -5.0 -0.10 ±5.0% 76 0.70 ±3.0% 6.5 +12.0 +0.10 ±5.0% -12.0 -0.10 ±5.0% 76 0.70 ±3.0% 6.5 +15.0 +0.08 ±5.0% -15.0 -0.08 ±5.0% 76 0.70 ±3.0% 6.5 +24.0 +0.05 ±5.0% -24.0 -0.05 ±5.0% 76 Notes: 1. Load regulation is measured for an output change of 10% to 90% at nominal input line. For multiple output models, the loads are balanced. 2. The MPM-05 series is specified for operation over the wide operating temperature range of -20°C to +55°C without derating. For operation over +55°C, derate the power linearly by 3.75%/°C from +55°C to +70°C. 3. Single output models are approved to EN60950. Approval for other models is pending. 4. It is recommended that a fuse be used on the input of a power supply for protection. For the MPM-05 series, a 1A/250 VAC slow blow should be used. Typical Connection Mechanical Dimensions Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) Pin Connections Pin 1 2 3 4 5 6 7 8 Single Dual Triple AC-Ground AC-Ground AC-Ground AC-Neutral AC-Neutral AC-Neutral AC-Line AC-Line AC-Line -Vo 1 -Vo 2 -Vo 1 No Pin No Pin +Vo 1 No Pin Common -Vo 2 No Pin No Pin Common +Vo 1 +Vo 1 +Vo 2 Typical Component Values Vout C1, C3, C5 C2, C4, C6 Fuse TVS 3.3 330 ~ 1,000 µF/16V P6KE6.8A 5.0 330 ~ 1,000 µF/16V P6KE6.8A 1A/ 0.1 µF/50V 12.0 220 µF/25V 250 VAC P6KE16A Ceramic Slow Blow P6KE20A 15.0 220 µF/25V 24.0 120 µF/35V P6KE33A Notes: 1. C1, C3 and C5 are high frequency, low resistance electrolytic capacitors. Refer to the suppliers specifications for capacitance/current ratings. 2. Voltage derating on all capacitors should be 80% or higher. 3. C2, C4 and C6 eliminate high frequency noise. 4. The TVS is recommended to protect load circuitry in the event of a module failure. • MicroPower Direct www.micropowerdirect.com • 292 Page Street Ste D Stoughton, MA 02072 TEL: (781) 344-8226 FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com
MPM-05T-0505 价格&库存

很抱歉,暂时无法提供与“MPM-05T-0505”相匹配的价格&库存,您可以联系我们找货

免费人工找货