0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
MPM-10D-12IS

MPM-10D-12IS

  • 厂商:

    MPD

  • 封装:

  • 描述:

    MPM-10D-12IS - Chassis Mount, 15W Single, Dual & Triple Out AC/DC Power Supplies - MicroPower Direct...

  • 数据手册
  • 价格&库存
MPM-10D-12IS 数据手册
MPM-10IS Series Board Mount, 10W Single & Dual Output AC/DC Power Supplies Key Features: • 10W Output Power • Universal 85-265 VAC Input • EN 60950 Approved • Meets IEC Safety Class II • Industry Standard Pin-Out • Single and Dual Outputs • Meets EN55022 B • >300 kHour MTBF Electrical Specifications Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Input Voltage Range Input Frequency Input Current Inrush Current EMI Safety Ground Leakage Current Conditions Min. Typ. 85 47 See Model Selection Guide 115 VAC 10.0 230 VAC 20.0 Meets CISPR Pub. 22/FCC Class B 115 VAC 230 VAC Max. 265 440 Units VAC Hz A Pk 0.1 0.3 mA Units Output Parameter Output Voltage Output Current Output Voltage Accuracy Line Regulation Load Regulation, Single Output Load Regulation, Dual Output Ripple & Noise (20 MHz) Hold-Up Time Temperature Coefficient Over Voltage Protection Short Circuit Protection, Note 3 Overload Protection, Note 4 Conditions Min. Typ. Max. See Model Selection Guide See Model Selection Guide ±1.0 ±2.0 VIN = Min to Max ±0.5 ±1.0 IO = Min to Max ±0.5 ±1.0 IO = Min to Max ±2.5 ±5.0 3.3V & 5.0 VDC Output 1.5 1.8 All Other Outputs 0.8 1.0 115 VAC, 60 Hz 20 ±0.02 Zener Diode Clamp 120 Continuous (Autorecovery) Typ. 120% to 180% of Output Power Conditions Input to Output Input to Output, Flash Tested For 60S 500 VDC Conducted Electrostatic Discharge (ESD) RF Field Susceptibility Electrical Fast Transients/Bursts On Mains Surge Min. 3,000 4,700 100 Typ. Max. % % % % %VP-P of VO mSec %/°C % of VO General Parameter Isolation Voltage Isolation Test Voltage Isolation Resistance EMI/RFI EMC Compliance Switching Frequency Units VAC VAC M EN 55022 Level B IEC/EN 61000-4-2 Level 3 IEC/EN61000-4-3 IEC/EN 61000-4-4 Level 3 2 kV IEC/EN 61000-4-5 Level 3 1kV/2 kV 100 kHz Units °C °C % MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Environmental Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Conditions Min. Typ. Max. -25 +25 +71 -40 +85 Free Air Convection (See Derating Curve) RH, Non-condensing 95 Ambient Physical Case Size Case Material Weight 2.52 x 1.77 x 0.75 Inches (64.0 x 45.0 x 19.0 mm) Non-Conductive Plastic& Fiberglass (UL94-V0) 3.23 Oz (92g) Conditions Min. Typ. MIL HDBK 217F, 25°C, Gnd Benign 300 IEN 60950, IEC 60950 IEN 60950, IEC 60950 IEC 61140 Class II Max. Units kHours Reliability Specifications Parameter MTBF Safety Standards Safety Approvals Safety Class Model Selection Guide Input Model Number MPM-10S-03IS MPM-10S-05IS MPM-10S-12IS MPM-10S-15IS MPM-10S-24IS MPM-10D-12IS MPM-10D-15IS Current (A) 115 VAC 0.137 0.199 0.191 0.191 0.190 0.172 0.169 230 VAC 0.075 0.075 0.075 0.075 0.075 0.075 0.075 Output 1 (Vout 1) Voltage (VDC) Output 2 (Vout 2) Voltage (VDC) Current (A) Max. 2.000 2.000 0.833 0.666 0.416 +0.380 +0.300 Min. 0.200 0.200 0.083 0.066 0.042 +0.038 +0.030 Current (A) Max. Min. Capacitive Load (µF, Max) Efficiency (%, Typ) 3.3 5.0 12.0 15.0 24.0 +12.0 +15.0 3,900 3,300 2,200 2,200 1,000 -12.0 -15.0 -0.380 -0.300 -0.038 -0.030 ±1,000 ±1,000 70 73 76 76 76 77 77 Other output combinations are available Contact the factory for details at: sales@micropowerdirect.com Notes: 1. Load regulation is measured for an output change of 0% to 100% at nominal input line. For multiple output models, the loads are balanced. 2. Operation at no-load will not damage these units. However, they may not meet all specifications. 3. Output short circuit protection is provided by a “hiccup mode” circuit. The unit recovers automatically when the fault condition is removed. 4. Output overload protection is provided by a fold back current limiting circuit. 5. The MPM-10IS series includes a built-in 2A/250 VAC fuse. It is recommended that an external 1.5A slow blow fuse also be used on the input for protection. Derating Curve Mechanical Dimensions Pin Connections Pin Single Dual 1 AC-Neutral AC-Neutral 2 AC-Line AC-Line 3 -Vo -Vo 4 NC Common 5 +Vo +Vo NP = No Connection Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) MicroPower Direct www.micropowerdirect.com • 292 Page Street Ste D Stoughton, MA 02072 TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com
MPM-10D-12IS 价格&库存

很抱歉,暂时无法提供与“MPM-10D-12IS”相匹配的价格&库存,您可以联系我们找货

免费人工找货