0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
MPM-15D-15CM

MPM-15D-15CM

  • 厂商:

    MPD

  • 封装:

  • 描述:

    MPM-15D-15CM - Chassis Mount, 15W Single, Dual & Triple Out AC/DC Power Supplies - MicroPower Direct...

  • 数据手册
  • 价格&库存
MPM-15D-15CM 数据手册
MPM-15CM Series Ch Chassis M i Mount, 15W t 15W Single, Dual & Triple Out AC/DC Power Supplies Key Features: • 15W Output Power • Universal 85-265 VAC Input • EN60950 Approved • Single, Dual & Triple Outputs • Meets EN55022 B • Meets IEC Safety Class II • Chassis Mount Case DIN Rail Mounting Kit Available! Electrical Specifications Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Input Voltage Range Input Frequency Input Current Inrush Current EMI Safety Ground Leakage Current Conditions Min. Typ. Max. 85 265 47 440 See Model Selection Guide 115 VAC 15.0 230 VAC 30.0 Meets CISPR Pub. 22/FCC Class B 115 VAC 0.1 230 VAC 0.3 Units VAC Hz A Pk mA Units Output Parameter Output Voltage Output Current Output Voltage Accuracy Line Regulation Load Regulation, Single Output Load Regulation, Dual, Triple Aux Output Ripple & Noise (20 MHz) Hold-Up Time Temperature Coefficient Over Voltage Protection Short Circuit Protection, Note 3 Overload Protection, Note 4 Conditions Min. Typ. Max. See Model Selection Guide See Model Selection Guide ±1.0 ±2.0 VIN = Min to Max ±0.2 ±1.0 IO = Min to Max ±0.5 ±1.0 IO = Min to Max ±2.5 ±5.0 5.0 VDC Output 1.5 1.8 All Other Outputs 0.8 1.0 115 VAC, 60 Hz 20 ±0.02 Zener Diode Clamp 120 Continuous (Autorecovery) Typ. 120% to 180% of Output Power Conditions Input to Output Input to Output, Flash Tested For 60S 500 VDC Conducted Electrostatic Discharge (ESD) RF Field Susceptibility Electrical Fast Transients/Bursts On Mains Surge Min. 3,000 4,700 100 Typ. Max. % % % % %VP-P of VO mSec %/°C % of VO General Parameter Isolation Voltage Isolation Test Voltage Isolation Resistance EMI/RFI EMC Compliance Units VAC VAC MΩ EN 55022 Level B IEC/EN 61000-4-2 Level B IEC/EN61000-4-3 IEC/EN 61000-4-4 Level 3 2 kV IEC/EN 61000-4-5 Level 3 1kV/2 kV 100 kHz Units °C °C % MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Switching Frequency Environmental Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Conditions Min. Typ. Max. -25 +25 +71 -40 +85 Free Air Convection (See Derating Curve) RH, Non-condensing 95 Ambient Physical Case Size, Chassis Mount Case Size, DIN Rail Option Case Material Weight 3.81 x 2.13 x 0.92 Inches (96.7 x 54.0 x 23.3 mm) 3.81 x 2.13 x 1.35 Inches (96.7 x 54.0 x 34.3 mm) Non-Conductive Plastic& Fiberglass (UL94-V0) 5.69 Oz (162g) Conditions Min. Typ. MIL HDBK 217F, 25°C, Gnd Benign 280 IEN 60950, IEC 60950 IEN 60950, IEC 60950 IEC 61140 Class II Max. Units kHours Reliability Specifications Parameter MTBF Safety Standards Safety Approvals Safety Class Model Selection Guide Model Number MPM-15S-05CM MPM-15S-12CM MPM-15S-15CM MPM-15S-24CM MPM-15S-48CM MPM-15D-12CM MPM-15D-15CM MPM-15T-0512CM MPM-15T-0515CM Output 1 (Vout 1) Current (A) Voltage 115 VAC 230 VAC (VDC) Max. Min. 0.290 0.275 0.275 0.275 0.273 0.275 0.275 0.290 0.284 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 5.0 12.0 15.0 24.0 48.0 +12.0 +15.0 5.0 5.0 3.000 1.250 1.000 0.625 0.310 +0.625 +0.500 2.000 1.80 0.300 0.125 0.100 0.063 0.030 +0.063 +0.050 +0.200 +0.200 Input Current (A) Output 2 (Vout 2) Current (A) Voltage (VDC) Max. Min. Output 3 (Vout 3) Current (A) Voltage (VDC) Max. Min. Capacitive Efficiency Load (%, Typ) (µF, Max) -12.0 -15.0 +12.0 +15.0 -0.625 -0.500 +0.200 +0.150 -0.063 -0.050 +0.020 +0.015 -12.0 -15.0 -0.200 -0.150 -0.020 -0.015 3,900 2,200 2,200 2,200 1,000 ±1,500 ±1,500 Note 5 Note 5 75 79 79 79 79 79 79 74 74 Other output combinations are available Contact the factory for details at: sales@micropowerdirect.com Notes: 1. Load regulation is measured for an output change of 0% to 100% at nominal input line. For multiple output models, the loads are balanced. 2. Operation at no-load will not damage these units. However, they may not meet all specifications. 3. Output short circuit protection is provided by a “hiccup mode” circuit. The unit recovers automatically when the fault condition is removed. 4. Output overload protection is provided by a fold back current limiting circuit. 5. For triple output models, the maximum capacitive load for 5 VDC outputs is 2,200 µF. For all other outputs it is ±1,500 µF. 6. The MPM-15CM series includes a built-in 2.0A/250 VAC fuse. It is recommended that an external 1.5A slow blow fuse also be used on the input for protection. Derating Curve Mechanical Dimensions, Chassis Mount Pin Connections Pin Single Dual Triple 1 AC-Neutral 2 AC-Line 3 +Vo +Vo +Vo 2 4 NC NC +Vo 1 5 -Vo Common Common 2/3 6 NC NC -Vo 1 7 NC -Vo +Vo 3 NC = No Connection A DIN Rail mounting kit is available Contact the factory for details at: sales@micropowerdirect.com MicroPower Direct www.micropowerdirect.com • Notes: • All dimensions are typical in inches (mm) • Tolerance x. = ±0.01 (±0.25) Tolerance x.xx 292 Page Street Ste D Stoughton, MA 02072 TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com
MPM-15D-15CM 价格&库存

很抱歉,暂时无法提供与“MPM-15D-15CM”相匹配的价格&库存,您可以联系我们找货

免费人工找货