Product Data Sheet
SC DI
FEATURES
TI N O
HL01U
1 WATT UNREGULATED DC/DC CONVERTER
ED NU
LOW COST INTERNAL FILTERING SURFACE MOUNT CONSTRUCTION TEMPERATURE RANGE: -25°C TO +70°C
HIGH EFFICIENCY NON-CONDUCTIVE CASE SURFACE MOUNT PACKAGE (SMD)
DESCRIPTION
The HL01U Series offers an extensive selection of input and output voltages to choose from. These miniature, unregulated DC/DC converters come in 24-pin DIP and SMD packages. This small size is possible through the use of surface mount
manufacturing technologies. The HL01U Series utilizes a 125KHz push-pull oscillator in the input stage with internal filtering to reduce the output noise. The use of surface mount construction and automated manufacturing processes increase consistency and reliability while reducing overall cost.
ABSOLUTE MAXIMUM RATINGS
Internal Power Dissipation..................................................................30 Sec Short Circuit Duration..................................................................Momentary Lead Temperature (soldering, 10 seconds max)..............................+300°C
ORDERING INFORMATION
HL01U xxyzz Y/Z /H Device Family HL Indicates DC/DC Converter Model Number Where: xx = Input Voltage y = Number or Outputs (Single "S", Dual "D") zz = Output Voltage Package Option Screening Option DIP Package only
*
* Note: Refer to Reflow Profile for SMD Models.
HL01U revE, 12/08
Page 1
ELECTRICAL +SPECIFICATIONS current unless otherwise specified. Specifications typical at T = 25°C, nominal input voltage, rated output
A
NOMINAL INPUT MODEL HL01U05S05 HL01U05S12 HL01U05S15 HL01U12S05 HL01U12S12 HL01U12S15 HL01U15S05 HL01U15S12 HL01U15S15 HL01U24S05 HL01U24S12 HL01U24S15 HL01U05D05 HL01U05D12 HL01U05D15 HL01U12D05 HL01U12D12 HL01U12D15 HL01U15D05 HL01U15D12 HL01U15D15 HL01U24D05 HL01U24D12 HL01U24D15 (VDC) 5 5 5 12 12 12 15 15 15 24 24 24 5 5 5 12 12 12 15 15 15 24 24 24
RATED OUTPUT VOLTAGE VOLTAGE (VDC) 5 12 15 5 12 15 5 12 15 5 12 15 ±5 ±12 ±15 ±5 ±12 ±15 ±5 ±12 ±15 ±5 ±12 ±15 (mA) 200 83 67 200 83 67 200 83 67 200 83 67 ±100 ±41 ±33 ±100 ±41 ±33 ±100 ±41 ±33 ±100 ±41 ±33
RATED OUTPUT CURRENT (mA) 30 30 30 25 25 25 20 20 20 15 15 15 30 30 30 25 25 25 20 20 20 15 15 15
INPUT CURRENT NO LOAD RATED LOAD (mA) 300 260 260 120 120 120 100 100 100 65 65 65 300 260 260 120 120 120 100 100 100 65 65 65 70 74 74 67 70 70 67 70 70 67 70 70 70 74 74 67 70 70 67 70 70 67 70 70 (%) EFFICIENCY
COMMON at T = +25°C, nominal input voltage, rated output current unless otherwise specified. SPECIFICATIONS Specifications typical
A
PARAMETER INPUT Voltage Range
CONDITIONS
MIN 4.5 10.8 13.5 22.6
TYP 5 12 15 24 30
MAX 5.5 13.2 16.5 26.4 100
UNITS VDC
Reflected Ripple Current ISOLATION Rated Voltage Test Voltage Resistance Capacitance Leakage Current OUTPUT Rated Power Voltage Setpoint Accuracy Temperature Coefficent Ripple & Noise Line Regulation Load Regulation 5 Vout Models All Others GENERAL Switching Frequency Package Weight MTTF per MIL-HDBK-217, Rev. F Ground Benign
VDC mAp-p
60 Hz, 10 Seconds
500 500 1 25 2 1 ±3 ±0.02 50 10 1 ±5 ±3 125 12
VISO= 240VAC, 60Hz
VDC Vpk G pF μArms W % %/°C mVp-p mVrms %/% % % kHz g kHr kHr
±5 100 ±1.5 ±10 ±10
BW = DC to 10MHz BW =10Hz to 2MHz High Line to Low Line 25% Rated Load to Rated Load 10% Rated Load to Rated Load
Circuit Stress Method TA = +25°C TA = +70°C -25 -40 -40
1100 550
TEMPERATURE Specification Operation Storage
+70 +85 +110
°C °C °C
Page 2
HL01U revE,12/08
MECHANICAL
Package/Pinout "Y" and "Z"
TOP VIEWS
HL01UxxyzzY HL01UxxyzzZ
SIDE VIEWS
END VIEWS
DIP PACKAGE
NU = Do Not Use. NC = No Internal Connection. Duplicate pin functions are internally connected. All dimensions are in inches (millimeters). GRID: 0.100 inches (2.54 millimeters) Typically Marked with: specific model ordered, date code, job code and Logo.
SMD PACKAGE
PIN CONNECTIONS
PIN#
1 2 3 10 11 12 13 14 15 22 23 24
SINGLES
+VIN NU NU -VOUT +VOUT -VIN -VIN +VOUT -VOUT NU NU +VIN
DUALS
+VIN -VOUT Common Common +VOUT -VIN -VIN +VOUT Common Common -VOUT +VIN
RECOMMENDED LAND PATTERN
RECOMMENDED REFLOW PROFILE
HL01U revE, 12/08
Page 3
TYPICAL PERFORMANCE CURVES
SAFE OPERATING AREA
NOTES: 1.) When operated within the SAFE OPERATING AREA as defined by the above curves, the output voltage of HL01U devices is guaranteed to be within 95% of its steady-state value within 100 milliseconds after the input voltage has reached 95% of its steadystate value. 2.) For dual output models, total load capacitance is the sum of the capacitances on the plus and minus outputs.
USA: Canada: UK:
Mansfield (MA), Tel: (508) 339 3000, email: sales@murata-ps.com Toronto, Tel: (866) 740 1232, email: toronto@murata-ps.com Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com
Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
www.murata-ps.com email: sales@murata-ps.com ISO 9001 & ISO 14001 REGISTERED
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2008 Murata Power Solutions, Inc.
France: Japan: China:
Germany: München, Tel: +49 (0)89-544334-0, email: ped.munich@murata-ps.com
Singapore: Parkway Centre, Tel: +65 6348 9096, email: singapore@murata-ps.com
HL01U revE,12/08
Page 4