Reference Data Sheet_MZB3004T04
1
Appearance
(No Polarity)
Table.1-1
Item
Specificaton
Outside dimension/tolerance
21±0.2mm
Thickness/tolerance
2
Condition
Except the terminal
19±0.2mm
3.4±0.2mm
Except the Jet nozzle
Ratings
Table.2-1
Rating
Operating Voltage Range
Environmental Operating
Temperature Range
Value
※1-1
Vdc
Condition
Back pressure <10kPa
8 to 19.5 ※1-1
Vdc
Back pressure ≧10kPa
0 to +45 ※1-2
°C
-
8 to 18
Unit
※1-1 Voltage to be applied to recommended driver circuit.
Less than 8Vdc driving may be occurred oscillation failure.
The pump can be driven by a voltage of 18 Vdc or more, only in the case where the back
pressure is +10 kPa.
If the back pressure is less than +10 kPa, and in addition the pump is driven by a voltage of
18 Vdc or more, there is a possibility of a breakdown occurring.
※1-2 Pump’s performance may decrease by self heating.
Please use it in its metal surface temperature less than or equal to 60°C.
1 / 14
Reference Data Sheet_MZB3004T04
3 Performance
3.1 Air Performance
Table. 3-1
Item
Specification
Free Flow Rate
@18Vdc
≧155ml/min
Static Pressure
@19.5Vdc
≧50kPa
Condition
Ambient temperature:18 to 28℃
Relative humidity: 25 to 85%RH
Atomspsheric pressure: 950 to 1020 hPa
3.2 Electrical Performance
Table. 3-2
Item
Drive Resonant
Frequency
Specification
Condition
21.5 to
24.5kHz
Note:
This catalog is for reference only and not an official product specification document, therefore, please review and approve our official product specification before ordering this product.
4 Typical Characteristic※4-1
Table. 4-1
Item
Free Flow Rate (0kPa)
@18Vdc
Power consumption
@Free Flow Rate 18Vdc
Static Pressure (0ml/min)
@19.5Vdc
Power consumption
@Static Pressure 19.5Vdc
Exhaust time ※4-2
Drive Resonant
Frequency
200ml/min
0.9W
60kPa
1.2W
≦10sec
23kHz
※4-1 There are not guaranteed values.
※4-2Time during which the pressure in the 100cc tank connected to MZB3004T04 which is connected to 100cc tank falls from 260mmHg to 15mmHg when the MZB3004T04 is turned off.
2 / 14
Reference Data Sheet_MZB3004T04
5 Test Result
※The following test results are only experimental results and are not guaranteed.
5.1 Physical Stress Test
Table. 5-1
Item
Test Condition
Vibration
Applying the vibration of maximum amplitude 1.5mm
and vibration frequency 10 to 55Hz/10G in each of 3
perpendicular directions for 11min x 24 times.
100G/6msec,
Applying the shock of 100G 3 times for six aspects.
75 cm height, wood floor, 3 times
Shock
Free Drop
Number
Result
10
G
10
G
10
G
Each direction 5
G
Outer Terminal (1) Pull
Strength
(1)Pull
Test force 5N, tensile direction is horizontal direction
for terminal,time-of-stressing 10 seconds
(2) Bend
(2)Bend
Test force 2.5N, bending direction is vertical direction
for terminal,time-of-stressing 2-3 seconds
Judgement condition:
After test, characteristics of table 3-1 and table 3-2 are within spec or variation in the characteristics is within 15%
3 / 14
Reference Data Sheet_MZB3004T04
5.2 Strage Test
Table. 5-2
Item
Test Condition
Pump shall be left in a chamber
(Temperature:-40±2℃) for 500 hours, then measured after leaving in natural condition for 2 hours.
Pump shall be left in a chamber
Dry Heat
(Temperature:+70±2℃,65±5%RH) for 500 hours,
then measured after leaving in natural condition for
2 hours.
Humidity
Pump shall be left in a chamber
(95±5%R.H.at +50±2℃) for 500 hours, then
measured after leaving in natural condition for 2
hour.
Thermal schock test Test temperature -25±3 ℃ / 60±2 ℃, Test time
30 min/, 30 min, 500 cycles tested, then measured
after leaving in natural condition for 2 hours.
Note) At Murata test condition
Number
Result
10
G
10
G
10
G
10
G
Cold
Judgement condition:
After test, characteristics of table 3-1 and table 3-2 are within spec or variation in the characteristics is within 15%.
5.3 Driving Test
Table. 5-3
Item
Test Condition
Number
Result
Continuous Driving
Test 1
Drive Voltage:16.5Vdc
Drive mode:Pressure mode (Closed space)
In crean room
10
G
Driving period:500hr
Environmental temperature:Room temperature
Continuous Driving Drive Voltage:16.5Vdc
Test 2
Drive mode:Flow mode (Opened space)
In crean room
10
G
Driving period:500hr
Environmental temperature:Room temperature
Note) At Murata test condition
The metal surface temperature of the products was 60 ° C or less when driven under the
above conditions.
Judgement condition:
After test, characteristics of table 3-1 and table 3-2 are within spec or variation in the
characteristics is within 15%.
4 / 14
Reference Data Sheet_MZB3004T04
6
Dimensioins
Y
X
Unit:mm
※ The dimensions without tolerances shown in the following figure are reference values.
5 / 14
Reference Data Sheet_MZB3004T04
7 Printing
1. Company symbol (
) and Parts number: MZB3004
2. Lot no.: 7 letters
1)
(1) Year : the last 2 digits of the year
(2) Month : 1~9, X:Oct., Y:Nov., Z:Dec.
2)
(3) Lot No : 0001~9999
1680017
The serial number each lot
Ex.) 2016. August lot
16
8
(1)
(2)
0017
(3)
Laser marking above letters
・Parts number details
MZ
B3
004
T04
①
②
③
④
④Packing (T04 : Tray)
③Representative characteristic
②Category・Model
①ID Mark
6 / 14
Reference Data Sheet_MZB3004T04
8 Packing Standard
8.1 Dimensions of Tray
7 / 14
Reference Data Sheet_MZB3004T04
8.2 Packaging Form
8.3 The Quantity per a box
Packaging Quantity: 400 pieces max. (= 50 pieces /tray x 8 trays)
However, total number of tray is 9 trays because empty tray is set on the top
Maximum 3 Lot mix/carton box
8.4 Content of Outer Label
The minimum packaging unit shall be a box. Each minimum package unit of pumps
shall be in a carton box and it shall be clearly marked with your company name, customer’s
and Murata’s part numbers, quantity and so on.
8 / 14
Reference Data Sheet_MZB3004T04
9. Considerations for soldering
9.1 Wiring
Lead wire should be through from back side terminal hole to top side.
And soldering is enough to treat top side only.
Metal side
Soldering iron
Wiring
Resin side
External terminal
9-2. Condition for soldering
Please solder the sample by using the soldering iron, and please don’t touch the housing directly.
Soldering Conditions
Temperature of iron
Contact time
Note
≦350℃
≦3Sec / each terminal
less than 3 cycle ( 350℃,3sec(max.) /cycle)
Note) Please careful excessive terminal bent.
To avoid trouble, please keep bending force to terminal 2.5N or less.
9 / 14
Reference Data Sheet_MZB3004T04
10.
!
Cautions
10-1 Limitation of applications
The products are designed and produced for application in ordinary electronic equipment (AV
equipment, OA equipment, telecommunication, etc). If the products are to be used in devices
requiring extremely high reliability following the application listed below, you should consult with
the Murata staff in advance.
- Aircraft equipment.
- Aerospace equipment
- Undersea equipment.
- Power plant control equipment.
- Medical equipment.
- Transportation equipment (vehicles, trains, ships, etc.).
- Traffic signal equipment.
- Disaster prevention / crime prevention equipment.
- Data-procession equipment.
- Application which malfunction or operational error may endanger human life and property of
assets.
- Application which related to occurrence the serious damage
- Application of similar complexity and/ or reliability requirements to the applications listed in the
above.
10-2 Fail-safe
If product malfunctions may result in serious damage, including that to human life, sufficient failsafe measures must be taken, including the following:
(1) Installation of protection circuits or other protective device to improve system safety
(2) Installation of redundant circuits in the case of single-circuit failure
10 / 14
Reference Data Sheet_MZB3004T04
11 Instruction for use
11-1. Since the product sucks and dischages air,contaminants and dust in the air tend to
accmulate inside the pump, and the contaminants and dust will influence the operation
time. Use the product in a clean environment, or use a filter to remove at least
submicron level of contaminants to prevent particles and dust from entering.
(※The use of filter does not guarantee suppression of the characteristics deterioration
of the product.) Our company doesn’t bear any responsibility with respect to the problems.
11.2 Please do not touch the component (included nozzle, Outer terminal.) with bare hands.
11.3 Applying load on the product during operation may cause characteristics drop or sound
noise generation. And more, when you push the center of a body temporarily at the time of
assembly, etc., please do not apply load more than 1kgf (10N).
11.4 Please refrain from using the product under the condensation environment.
11.5 When the drive of the product is stopped while it is connected to it with the container of
10cc or less, the noisy may occur. But it isn’t a defect.
11.6 Please pay attention to protect operating circuit from surge voltage provided by something
11.7 Please pay attention never to apply DC voltage and over 100mA current to the product.
11.8 Washing of the component is not acceptable, because it is not sealed.
11.9 Automatic mounting (SMT) is not acceptable.
11.10 No effect for the performance even if there are scratches on appearance and tarnishes of
material.
11.11 Please take electrostatic countermeasure with wrist band etc.
11 / 14
Reference Data Sheet_MZB3004T04
12 Notice on Storage
12.1 Please store the products in room where the temperature/humidity is stable. And avoid such
places where there are large temperature changes. Please store the products.
Under the following conditions : Temperature -10 to +40 deg
Humidity
10 to 85% RH
12.2 Expire date (Shelf life) of the products is 6 months after delivery under the conditions of a
sealed and an unopened package. Please use the products within 6 months after delivery. If
you store the products for a long time (more than 6months), use carefully because the prod
ucts may be degraded in the solder-ability and/or rusty.Please confirm solder-ability and char
acteristics for the products regularly
12.3 Please do not store the products in a chemical atmosphere (Acids, Alkali, Bases, Organic
gas, Sulfides and so on), because the characteristics may be reduced in quality, and/or be
degraded in the solder-ability due to the storage in a chemical atmosphere.
12.4 Please do not put the products directly on the floor without anything under them to avoid
damp places and/or dusty places
12.5 Please do not store the products in the places such as : in a damp heated place, in a place
where direct sunlight comes in, in place applying vibrations.
12.6 Please use the products immediately after the package is opened, because the characteris
tics may be reduced in quality, and/or be degraded in the solder-ability due to storage under
the poor condition.
12.7 Please do not drop products to avoid cracking of ceramic element.
12 / 14
Reference Data Sheet_MZB3004T04
13 Note
13.1 Please make sure that your product has been evaluated and confirmed against your specifi
cations when our product is mounted to your product.
13.2 Product specifications are subject to change or our products in it may be discontinued
without advance notice.
13.3 This catalog is for reference only and not an official product specification document,
therefore, please review and approve our official product specification before ordering
this product.
13 / 14
Reference Data Sheet_MZB3004T04
(Reference material)
Recommended circuit dirver
Schematic
BOM
14 / 14