NME 48V Series
www.murata-ps.com
Isolated 1W Single Output DC/DC Converters
Efficiency up to 80%
MTTF1
1kVDC Isolation
Isolation
Capacitance
Single Isolated Output
Efficiency
RoHS Compliant
Output Current
FEATURES
NME4805DC
NME4809DC
NME4812DC
NME4815DC
NME4805SC
NME4809SC
NME4812SC
NME4815SC
Output
Voltage
Order Code
Nominal Input
Voltage
SELECTION GUIDE
V
V
mA
%
pF
kHrs
48
48
48
48
48
48
48
48
5
9
12
15
5
9
12
15
200
111
83
66
200
111
83
66
70
75
80
80
70
75
80
80
32
50
76
75
32
50
76
75
213
194
164
140
213
194
164
140
Package
Style
Recommended
Alternative
DIP
DIP
DIP
DIP
SIP
SIP
SIP
SIP
MER1S4805SC
MER1S4809SC
MER1S4812SC
MER1S4815SC
MER1S4805SC
MER1S4809SC
MER1S4812SC
MER1S4815SC
Power Density 1.45W/cm3
When operated with additional external load capacitance the rise time of the input voltage will determine the maximum external
capacitance value for guaranteed start up. The slower the rise time of the input voltage the greater the maximum value of the
additional external capacitance for reliable start up.
UL 94V-0 Package Material
INPUT CHARACTERISTICS
Footprint from 0.69cm2
Parameter
Conditions
Min.
Typ.
Max.
Units
Industry Standard Pinout
Voltage Range
Continuous operation, 48V input types
43.2
48
52.8
V
48V Input
OUTPUT CHARACTERISTICS
Min.
Typ.
Max.
Units
1.0
W
1.2
15
10
150
%/%
5V, 9V, 12V and 15V Output
No Heatsink Required
Internal SMD Construction
Fully Encapsulated with Toroidal
Magnetics
No External Components Required
Custom Solutions Available
DESCRIPTION
Parameter
Conditions
Rated Power2
Voltage Set Point Accuracy
Line regulation
TA=0°C to 70°C
See tolerance envelope
High VIN to low VIN
10% load to rated load, 5V output types
10% load to rated load, all other output types
BW=DC to 20MHz, all output types
Load Regulation
2
Ripple and Noise
%
mV p-p
ABSOLUTE MAXIMUM RATINGS
Short-circuit protection3
Lead temperature 1.5mm from case for 10 seconds
Input voltage VIN, NME48 types
1 second
300°C
54V
The NME series of DC/DC Converters is
particularly suited to isolating and/or converting
DC power rails. The galvanic isolation allows
the device to be configured to provide an
isolated negative rail in systems where only
positive rails exist.
For full details go to
www.murata-ps.com/rohs
1. Calculated using MIL-HDBK-217F with nominal input voltage at full load.
2. See derating curve.
3. Supply voltage must be disconnected at the end of the short circuit duration.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
www.murata-ps.com/support
KDC_NME2.F02 Page 1 of 4
NME 48V Series
Isolated 1W Single Output DC/DC Converters
ISOLATION CHARACTERISTICS
Parameter
Conditions
Min.
Isolation test voltage
Resistance
Flash tested for 1 second
Viso= 500VDC
1000
1
Parameter
Conditions
Min.
Switching frequency
All types
Typ.
Max.
Units
VDC
GΩ
GENERAL CHARACTERISTICS
Typ.
Max.
100
Units
kHz
TEMPERATURE CHARACTERISTICS
Parameter
Conditions
Min.
Specification
Storage
Cooling
All output types
0
-55
Typ.
Max.
Units
70
150
°C
Free air convection
TOLERANCE ENVELOPE
+10%
+5%
VNOM
70°C
1.0
0.5 Safe Operating Area
125°C
0
0
150
50
100
Ambient Temperature (°C)
Output Voltage
Output Power (W)
TEMPERATURE DERATING GRAPH
1.5
Typical
L
oad Line
+2.5%
-2.5%
-7.5%
10
75
50
25
Output Load Current (%)
100
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions NME series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
For a part holding no specific agency approvals, such as the NME series, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or
60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part
could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must
be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to
safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,
construction and environment. The NME series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enamelled wire. While
parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically
polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We
therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage.
This consideration equally applies to agency recognised parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
www.murata-ps.com/support
KDC_NME2.F02 Page 2 of 4
NME 48V Series
Isolated 1W Single Output DC/DC Converters
PACKAGE SPECIFICATIONS
MECHANICAL DIMENSIONS
PIN CONNECTIONS - 8 PIN DIP
DIP Package
Pin
1
0.267 (6.80)*
0.386 (9.80)
NME4815DC
XYYWW
4
0.043 (1.09)
0.3 (7.62)
0.181 (4.60)
0.142 (3.60)
7
5
0.0118 (0.30)
0.0078 (0.20)
0.022 (0.55)
0.018 (0.45)
0.2 (5.08)
Function
1
-VIN
4
+VIN
5
+VOUT
7
-VOUT
0.3 (7.62)
0.453 (11.50)
PIN CONNECTIONS - 4 PIN SIP
0.0763 (1.94)
SIP Package
Pin
0.45
(11.48)
0.074 (1.89)
0.109 (2.77)
0.236
(6.00)**
0.393
(10.0)
NME4815SC
XYYWW
0.022 (0.55)
0.018 (0.45)
0.0118 (0.30)
0.0078 (0.20)
0.049
(1.25)
Function
1
-VIN
2
+VIN
3
-VOUT
4
+VOUT
0.3
(7.62)
1
0.181 (4.60)
0.142 (3.60)
2
3
4
0.022 (0.55)
0.018 (0.45)
* 0.303 (7.70) for 48V variants
** 0.3 (7.50) for 48V variants
All dimensions in inches ±0.01 (mm ±0.25mm). All pins on a 0.1 (2.54) pitch and within ±0.01 (0.25) of true position.
Weight: 1.48g (DIP) 1.30g (SIP)
www.murata-ps.com/support
KDC_NME2.F02 Page 3 of 4
NME 48V Series
Isolated 1W Single Output DC/DC Converters
PACKAGE SPECIFICATIONS (continued)
RECOMMENDED FOOTPRINT DETAILS
4 Pin SIP Package
8 Pin DIP Package
)0-&4
)0-&4
TUBE OUTLINE DIMENSIONS
4 Pin SIP Tube
8 Pin DIP Tube
Unless otherwise stated all dimensions in inches (mm) ±0.5mm.
Tube length (8 Pin DIP) : 20.47 (520mm ±2mm).
Tube length (4 Pin SIP) : 20.47 (520mm ±2mm).
Tube Quantity : 35
RoHS COMPLIANCE INFORMATION
This series is compatible with RoHS soldering systems with a peak wave solder temperature of 300°C for 10 seconds. The pin termination finish
on the SIP package type is Tin Plate, Hot Dipped over Matte Tin with Nickel Preplate. The DIP types are Matte Tin over Nickel Preplate. Both types
in this series are backward compatible with Sn/Pb soldering systems.
For further information, please visit www.murata-ps.com/rohs
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2018 Murata Power Solutions, Inc.
www.murata-ps.com/support
KDC_NME2.F02 Page 4 of 4
很抱歉,暂时无法提供与“NME2412DC”相匹配的价格&库存,您可以联系我们找货