UWR-5/7-D12A-C

UWR-5/7-D12A-C

  • 厂商:

    MURATA-PS(村田)

  • 封装:

    DIP7 模块

  • 描述:

    隔离模块 直流转换器 1 输出 5V 7A 10V - 18V 输入

  • 数据手册
  • 价格&库存
UWR-5/7-D12A-C 数据手册
UWR 26-40W Series www.murata-ps.com Single Output, High-Density, 3.3VOUT and 5 VOUT, 26-40 Watt, DC/DC Converters FEATURES n Standard 2" x 2" packages/pinouts n Output voltages/currents: • 3.3 • 5 Volts @ 8/9 Amps Volts @ 7/8 Amps n Choice of 3 input voltage ranges: 10-18V, 18-36V, 36-75V n Fully synchronous forward topology n Outstanding performance: • ±1% setpoint accuracy • Efficiencies to 90% • Noise as low as 75mVp-p • Stable no-load operation n On/off control and VOUT trim pins n Fully isolated (1500Vdc); I/O protected n Thermal shutdown n Designed to meet UL/EN/IEC60950-1 certification; CE marked PRODUCT OVERVIEW The newest products in Murata Power Solutions' flagship A-Series are the UWR, 26-40 Watt isolated singles. Housed in standard 2" x 2" metal packages (which have traditionally carried 15-20 Watt devices), these power converters supply up to 9 Amps @ 3.3V or 8 Amps at 5V. They exemplify Murata Power Solutions' relentless drive to bring designers more power/current, in standard packages/pinouts, without compromising reliability or resorting to thermal specmanship. Input voltage ranges are 10-18V (“D12” models), 18-36V (“D24” models) or 36-75V (“D48”) models. Employing an advanced, fully synchronous, high-frequency (300-360kHz) forward topology, UWR 26-40W singles attain 88-90% efficiencies enabling full-power operation to ambient temperatures as high as +55°C without supplemental air flow. Assembled using fully automated, SMT-on-pcb techniques, these DC/DC’s additionally provide low noise (75mVp-p), high accuracy (±1%), tight line/load regulation (±0.5%), quick step response (200µsec), and stable no-load operation. All models feature input pi filters, input undervoltage and overvoltage shutdown, output overvoltage protection, current limiting, short-circuit protection, and thermal shutdown. Each model has a VOUT trim pin as well as an on/off control function that may be ordered with either positive or negative logic. These devices are fully isolated (1500Vdc) and satisfy UL/ EN/IEC60950-1 safety requirements. “D48” models (36-75V inputs) are CE marked. FIGURE 1. SIMPLIFIED SCHEMATIC +OUTPUT (6) +INPUT (1) SWITCH CONTROL –OUTPUT (7) THERMAL SHUTDOWN –INPUT (2) PWM CONTROLLER ON/OFF CONTROL (4) UVLO & OVLO COMPARATORS OPTO ISOLATION REFERENCE & ERROR AMP VOUT TRIM (8) Typical topology is shown. For full details go to www.murata-ps.com/rohs www.murata-ps.com/support MDC_UWR26-40W.D02 Page 1 of 10 UWR 26-40W Series Single Output, High-Density, 3.3VOUT and 5 VOUT, 26-40 Watt, DC/DC Converters ➀ Performance Specifications and Ordering Guide * To Be Discontinued Input Output Model ➄ VOUT IOUT (Volts) (Amps) R/N (mVp-p) ➁ Regulation (Max.) VIN Nom. Typ. Max. Line Load ➂ (Volts) Range (Volts) IIN ➃ (mA/A) Package Efficiency (Case, Min. Typ. Pinout) UWR-3.3/8-D12A-C 3.3 8 75 110 ±0.05% ±0.5% 12 10-18 145/2.97 88% 89% UWR-3.3/9-D24A-C 3.3 9 75 110 ±0.5% ±0.5% 24 18-36 50/1.4 86% 88.5% C4, P6 UWR-3.3/9-D48AN-C 3.3 9 75 110 ±0.5% ±0.5% 48 36-75 25/0.7 86% 88.5% C4, P6 C4, P6 UWR-5/7-D12A-C 5 7 75 110 ±0.5% ±0.5% 12 10-18 160/3.26 85.5% 89.5% C4, P6 UWR-5/8-D24A-C 5 8 75 110 ±0.05% ±0.15% 24 18-36 90/1.82 90% 91.5% C4, P6 UWR-5/8-D48AN-C 5 8 75 110 ±0.5% ±0.5% 48 36-75 25/0.93 86% 90% C4, P6 ➀ Typical at TA = +25°C under nominal line voltage and full-load conditions, unless noted. ➁ Ripple/Noise (R/N) is tested/speciifed over a 20MHz bandwidth. All models are specified with an external 0.47µF multi-layer ceramic capacitor installed across their output pins. Using a 10µF multi-layer ceramic capacitor instead (e.g. TDK part no. C3225X5R1C106M) will further reduce the R/N to 35mVp-p typical and 75mVp-p maximum. ➂ Load regulation is specified over 0-100% load conditions. All models are stable and regulate within spec under noload conditions, with perhaps a slight increase in output ripple/noise. ➃ Nominal line voltage, no-load/full-load conditions. ➄ Please refer to the part number structure when ordering. P A R T N U M B E R M E C H A N I C A L S T R U C T U R E S P E C I F I C A T I O N S U WR - 3.3 / 9 - D48 A N - C Output Configuration: U = Unipolar RoHS-6 hazardous substance compliant Wide Range Input 2.00 (50.8) 0.45 (11.4) On/Off Logic, see below Nominal Output Voltage: 3.3 or 5 Volts Maximum Output Current in Amps INSULATED BASE 0.20 MIN (5.1) A-Series High Reliability Input Voltage Range: D12 = 10-18 Volts (12V nominal) D24 = 18-36 Volts (24V nominal) D48 = 36-75 Volts (48V nominal) 0.040 ± 0.002 DIA. (1.02 ± 0.05) 1.800 (45.72) 6 2 Part Number Suffixes 7 0.400 (10.16) UWR 26-40W DC/DC's are designed so the On/Off Control function on pin 4 can be ordered with either positive (open or "high" = on) or negative (open = off, pull low = on) logic. The standard part number with no suffix denotes positive logic. Add an "N" suffix to select negative logic. On/Off Control function (positive logic) on pin 4. Standard for D12, D24. 1.200 (30.48) 3 EQ. SP. @ 0.400 (10.16) 2.00 (50.8) 4 8 0.100 (2.54) 0.40 (10.2) BOTTOM VIEW "N" Suffix On/Off Control function (negative logic) on pin 4. Standard for D48. I/O Connections Pin Function P6 1 +Vin 2 –Vin 3 No Pin 4 On/Off Control 5 No Pin 6 +Vout 7 –Vout 8 Trim 0.10 (2.5) 5 0.200 (5.08) 1 No Suffix METAL CASE Case C4 Dimensions are in inches (mm shown for ref. only). Third Angle Projection Note For D12A and D24A models, the case is connected to Pin 2 (–Input). For D48A models, the case is connected to Pin 1 (+Input). Tolerances (unless otherwise specified): .XX ± 0.02 (0.5) .XXX ± 0.010 (0.25) Angles ± 2˚ Components are shown for reference only. www.murata-ps.com/support * Last time buy date is 3/31/2021. Please click here to view product discontinuance notice MDC_UWR26-40W.D02 Page 2 of 10 UWR 26-40W Series Single Output, High-Density, 3.3VOUT and 5 VOUT, 26-40 Watt, DC/DC Converters Performance/Functional Specifications Typical @ TA = +25°C under nominal line voltage and full-load conditions, unless noted. ➀➁ Dynamic Characteristics Input Input Voltage Range: D12 Models D24 Models D48 Models 10-18 Volts (12V nominal) 18-36 Volts (24V nominal) 36-75 Volts (48V nominal) Overvoltage Shutdown: D12 Models D24 Models D48 Models 19-23 Volts (21V typical) 37-43 Volts (40V typical) 76.5-82 Volts (78V typical) Start-Up Threshold: ➂ D12 Models D24 Models D48 Models 8.5-10 Volts (9V typical) 16-18 Volts (17V typical) 33.5-36 Volts (35V typical) Undervoltage Shutdown: ➂ D12 Models D24 Models D48 Models 7.5-9 Volts (8V typical) 15-17 Volts (16V typical) 31-33.5 Volts (32V typical) Input Current: Normal Operating Conditions Standby Mode (Off, OV, UV) See Ordering Guide 5mA Input Reflected Ripple Current 250mAp-p Input Filter Type D12 Models D24 Models D48 Models Capacitive (13.2µF) Pi (0.01µF-1µH-6.6µF) Pi (0.01µF-2.2µH-2µF) Reverse-Polarity Protection Brief duration, 5A maximum On/Off Control: ➃ ➄ "N" Models On = open or 13V - +VIN, IIN = 1.6mA max. Off = 0-0.8V, IIN = 2.6mA max. On = 0-0.8V, IIN = 1mA max. Off = open or 3.3-+VIN, IIN = 1mA max. Output VOUT Accuracy (50% load): Dynamic Load Response: (50-100% load step to 1% VOUT) 200µsec maximum Start-Up Time: VIN to VOUT On/Off to VOUT 10ms 10ms Switching Frequency: UWR-3.3/8-D12A UWR-3.3/9-D24A, -D48A UWR-5/7-D12A UWR-5/8-D24A, -D48A 360kHz (±36kHz) 300kHz (±30kHz) 360kHz (±36kHz) 310kHz (±30kHz) Environmental MTBF ➅ UWR-5/8-D24A Bellcore, ground fixed, full power 25°C ambient 1.6 million hours Operating Temperature ➁ -40 to +85°C, with derating Thermal Shutdown +110°C case Storage Temperature –40 to +120°C Flammability UL94V-0 Physical  Dimensions See mechanical specifications Case Material Corrosion resistant steel with non-conductive, epoxy-based, black enamel finish and plastic baseplate Pin Material RoHS: Gold plate over copper alloy Non-RoHS: Pure tin over copper alloy Weight: 2.7 ounces (76.5 grams) Primary to Secondary Insulation Level Functional (D12, D24 models) Basic (D48 models) ±1.0%, maximum Minimum Loading for Specification: ➁ 10% of IOUT maximum Minimum Loading for Stability: ➆ No load Ripple/Noise (20MHz BW) ➀ ➅ See Ordering Guide Line/Load Regulation See Ordering Guide Efficiency See Ordering Guide Trim Range ➁ ±5% Isolation Voltage: Input-to-Output Output to Case 1500Vdc minimum 1500Vdc minimum Isolation Capacitance 470pF Isolation Resistance 100MΩ Current Limit Inception (@98%VOUT): 3.3VOUT Models 5VOUT Models 10.5-11.5 Amps 8.5-9.5 Amps Short Circuit Current: (Average) 3.3VOUT Models 5VOUT Models 3 Amps maximum 4 Amps maximum Overvoltage Protection: 3.3VOUT Models 5VOUT Models Output voltage comparator 3.7-4.1 Volts 5.6-7.1 Volts Temperature Coefficient ±0.02% per °C. ➀ All models are specified with external 0.47µF ceramic output capacitor. ➁ See Technical Notes/Graphs for details. ➂ Applying a voltage to On/Off Control (pin 4) when no input power is applied to the converter can cause permanent damage. ➃ Output noise may be further reduced with the addition of additional external output capacitors. See Technical Notes. Use only as much output filtering as needed and no more. Larger caps (especially low-ESR ceramic types) may slow transient response or degrade dynamic performance. ➄ The On/Off Control is designed to be driven with open-collector logic or the application of appropriate voltage levels. Voltages may be referenced to the –Input (pin 2). ➅ Demonstrated MTBF available on request. www.murata-ps.com/support MDC_UWR26-40W.D02 Page 3 of 10 UWR 26-40W Series Single Output, High-Density, 3.3VOUT and 5 VOUT, 26-40 Watt, DC/DC Converters Absolute Maximum Ratings Input Voltage: Continuous: D12A Models D24A Models D48A Models Transient (100msec): D12A Models D24A Models D48A Models On/Off Control (pin 4) Max. Voltages Referenced to –Input (pin 2) No Suffix "N" Suffix 18 Volts 36 Volts 75 Volts 25 Volts 50 Volts 100 Volts +VIN +VIN Input Reverse-Polarity Protection Current must be
UWR-5/7-D12A-C 价格&库存

很抱歉,暂时无法提供与“UWR-5/7-D12A-C”相匹配的价格&库存,您可以联系我们找货

免费人工找货