0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
VKA150MS24-205C

VKA150MS24-205C

  • 厂商:

    MURATA-PS(村田)

  • 封装:

  • 描述:

    VKA150MS24-205C - 150 Watt Single Output Half Brick DC/DC Converter - Murata Power Solutions Inc.

  • 数据手册
  • 价格&库存
VKA150MS24-205C 数据手册
V VKA150MS24-205C OBSOLETE PRODUCTle Output Half Brick DC/DC Converter 150 Watt Sing O Watt Single Contact Factory for Replacement Model RoHS Compliant 33 - 75V Input Range High Efficiency: 90% Typical 100μS Transient Response 50 - 100% Load Step 420 kHz Fixed-Frequency Operation Remote Sense UL/CUL 1950, VDE EN60950 Operation to +100°C Baseplate Temperature Primary Remote On/Off, Negative Logic Output Voltage Trim Continuout Short-Circuit Protection Thermal Shutdown Case Ground Pin The VKA150MS24-205C DC/DC converter presents an economical and practical solution for distributed power system architectures which require high power density and efficiency while maintaining system modularity and upgradeability. With the ability to operate over a wide input voltage range of 33 to 75 volts, this module is ideal for use in battery backup applications common in todays’ telecommunication and electronic data processing applications. The output is fully isolated from the input, allowing for a variety of polarity and grounding configurations. The VKA150MS24-205’s proprietary control circuitry responds to 50-100% load steps in 100μSeconds to within 1% nominal Vout. The patented fixed frequency architecture combined with surface mount technology results in a compact, efficient and reliable solution to DC/DC conversion requirements. Safety approvals per UL/CUL 1950, EN 60950. PRODUCT IDENTIFICATION MODEL VKA150MS24-205C INPUT VOLTAGE 48VDC VOUT (VDC) 24.0V IOUT (A) 6.25 EFFICIENCY MIN 89 TYP 90 ORDERING INFORMATION VKA150 MS24-205C Device Family Indicates 150 Watt Regulated Unit Model Number Lead Length 0.200” Remote On-Off Logic: Negative C = RoHS Compliant   ISO9001 CERTIFIED For full details go to www.murata-ps.com/rohs www.murata-ps.com Technical enquiries - email: sales@murata-ps.com, tel: +1 508 339 3000 VKA150MS24-205C.B01 Page 1 of 3 VKA150MS24-205C 150 Watt Single Output Half Brick DC/DC Converter SPECIFICATIONS, ALL MODELS Specifications are at TCASE = +40°C Nominal Input Voltage unless otherwise specified. PARAMETER INPUT Voltage Range Maximum Input Current Reflected Ripple Current Input Ripple Rejection No Load Input Current MS Power Dissipation MS No Load Standby, Primary On/Off Disabled MS Inrush Charge Quiescent Operating Current Primary On/Off Disabled CONDITIONS MIN TYP 48 MAX 75 6.6 550 UNITS VDC A mA dB mA W W mC mA INPUT VIN = 30VDC Peak - Peak DC to 1KHz 50 60 100 4.8 0.4 VIN = VINmax 8 0.360 12 PARAMETER OUTPUT Rated Power Set point Accuracy Line Regulation Load Regulation Output Temperature Drift Output Ripple, p-p Output Current Limit Inception Output Short-Circuit Current Output Overvoltage Limit Transient Response Peak Deviation Settling Time CONDITIONS MIN TYP MAX 150 1 0.05 0.5 ±.05 1.5% 150% 150% 140% 3% 100 UNITS W % % % %/°C VOUT, Nom lOUT, Nom lOUT, Nom VOUT, Nom VOUT, Nom μSec OUTPUT High Line to Low Line No Load to Rated Load DC to 20MHz BW 105% 120% 50 to 100% Load Step di/dt = 0.1A/μSec VOUT, 1% of Nominal Output 0.02 0.2 ±.02 130% 120% 2 75 PARAMETER ISOLATION Input to Output Input to Baseplate Output to Baseplate Resistance Capacitance Leakage Current GENERAL Switching Frequency Remote Sense Compensation CONDITIONS Peak Test for 2 Seconds MIN 1500 1500 500 10 TYP MAX UNITS VDC VDC VDC MΩ pF μA, rms VISO = 240VAC, 60Hz 400 2000 180 420 440 0.5 KHz V VOUT, Nom GENERAL Output Voltage Adjust Range -50% / +10% Remote On/Off Control Inputs Primary Sink Current-Logic Low Vlow Vhigh Turn-on Time Weight TEMPERATURE Operation/Specification Storage Shutdown Temperature Thermal Impedance, case-ambient Lead Solder Temperature Open Collector/Drain 1.0 0.4 Open Collector 8.0 3 (85) +100 +125 +115 +300 mA V mSec oz (g) °C °C °C °C/W °C Within 1% of Rated Output 5.0 Case Temperature Case Temperature Case Temperature 10 Seconds max -40 -55 +100 +25 +25 8.2 www.murata-ps.com Technical enquiries - email: sales@murata-ps.com, tel: +1 508 339 3000 VKA150MS24-205C.B01 Page 2 of 3 VKA150MS24-205C 150 Watt Single Output Half Brick DC/DC Converter MECHANICAL NOTES: All dimensions are in inches (millimeters). 0.530 MAX [13.46] 0.20 [5.1] PIN PLACEMENT TOLERANCE: ± 0.005” MECHANICAL TOLERANCE: ± 0.015” .040 [1.02] DIA. 7 PLACES .081 [2.06] DIA. 2 PLACES Marked with: specific modeL ordered, date code, job code. Material: Units are encapsulated in a low thermal resistance molding compound which has excellent chemical resistance, wide operating temperature range, and good electrical properties under high humidity environments. The encapsulant and outer shell of the unit have ul94v-0 ratings. lead material is matte tin 100 microinches min., over nickel, 40-80 microinches. 0.20 [5.1] 0.50 [12.7] 0.40 [10.16] .400 [10.16] 2.000 [50.80] 1.000 [25.40] 2.40 [61.0] MAX 0.700 [17.78] 1.000 [25.40] 1.400 [35.56] 1.400 [35.56] 0.19 [4.8] 1.900 [48.26] MOUNTING INSERTS M3 X 0.5 THRU, 4 PLACES MAX. TORQUE, 8 IN/LBS 2.28 [57.91] MAX OUTPUT ADJUST VOLTAGE This feature allows the user to accurately adjust the module’s output voltage set point to a specified level. This is achieved by connecting a resistor or potentiometer from the TRIM terminal to either the +Vout terminal (for increased Vout) or the -Vout terminal (for decreased Vout). The formulae below describe the trim resistor value to obtain a Vout change of Δ%. VO is output voltage prior to adjustment. Radj - up = OVP NOTE Special attention should be given to the peak voltage deviation during a dynamic load step when trimming the output above the original set point to avoid tripping the overvoltage protection circuit. Should an OVP condition occur, the converter will go into a latch condition and must be externally reset before it will return to normal operation. ( Vo(100 + Δ%) (100 Δ%) -2 Ω 1.225Δ% _ (100 + 2Δ%) Ω Δ% ) THROUGH-HOLE SOLDERING INFORMATION These devices are intended for wave soldering or manual soldering. They are not intended to be subject to surface mount processes under any circumstances. The normal wave soldering process can be used with these devices where the device is subjected to a maximum wave temperature of 260°C for a period of no more than 10 seconds. Within this time and temperature range, the integrity of the device’s plastic body will not be compromised and internal temperatures within the converter will not exceed 175°C. Care should be taken to control manual soldering limits identical to that of wave soldering. Radj - down = USA: UK: France: Japan: Tucson (Az), Tel: (800) 547 2537, email: sales@murata-ps.com Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com Website: www.murata-ps.jp Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com Canada: Toronto, Tel: (866) 740 1232, email: toronto@murata-ps.com Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356 www.murata-ps.com email: sales@murata-ps.com ISO 9001 REGISTERED 07/28/08 Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2008 Murata Power Solutions, Inc. Germany: München, Tel: +49 (0)89-544334-0, email: munich@murata-ps.com China: www.murata-ps.com Technical enquiries - email: sales@murata-ps.com, tel: +1 508 339 3000 VKA150MS24-205C.B01 Page 3 of 3
VKA150MS24-205C 价格&库存

很抱歉,暂时无法提供与“VKA150MS24-205C”相匹配的价格&库存,您可以联系我们找货

免费人工找货