NTA1215MC

NTA1215MC

  • 厂商:

    MURATA

  • 封装:

  • 描述:

    NTA1215MC - Isolated 1W Dual Output SM DC/DC Converters - Murata Manufacturing Co., Ltd.

  • 数据手册
  • 价格&库存
NTA1215MC 数据手册
NTA Series Isolated 1W Dual Output SM DC/DC Converters SELECTION GUIDE Order Code 1 Nominal Input Voltage V 3.3 3.3 3.3 3.3 3.3 5 5 5 5 5 5 12 12 12 12 Output Voltage V ±3.3 ±5 ±9 ±12 ±15 ±3.3 ±5 ±5 ±9 ±12 ±15 ±5 ±9 ±12 ±15 Output Current mA ±152 ±100 ±55 ±42 ±33 ±152 ±100 ±100 ±55 ±42 ±33 ±100 ±55 ±42 ±33 Input Current at Rated Load mA 402 388 405 390 392 259 290 251 267 260 256 121 113 111 110 Efficiency % 75 78 75 77 77 77 69 80 75 77 78 69 74 75 76 Isolation MTTF2 Capacitance pF 29 30 34 40 42 31 33 42 38 44 43 50 72 89 100 kHrs 1005 399 827 375 206 964 1697 367 682 343 188 559 375 243 154 FEATURES RoHS compliant Efficiency up to 78% Wide temperature performance at full 1 Watt load, –40°C to 85°C UL 94V-0 Package material Footprint over pins 1.64cm2 Lead frame technology 3.3V, 5V & 12V Input 3.3V, 5V, 9V, 12V & 15V Output Internal SMD construction Toroidal magnetics 1kVDC Isolation MTTF up to 2.1 Million hours Power density 1.36W/cm3 No heatsink required Custom solutions available Multi-layer ceramic capacitors NTA0303MC NTA0305MC NTA0309MC NTA0312MC NTA0315MC NTA0503MC NTA0505MC NTA0505MEC NTA0509MC NTA0512MC NTA0515MC NTA1205MC NTA1209MC NTA1212MC NTA1215MC When operated with additional external load capacitance the rise time of the input voltage will determine the maximum external capacitance value for guaranteed start up. The slower the rise time of the input voltage the greater the maximum value of the additional external capacitance for reliable start up. INPUT CHARACTERISTICS Parameter Voltage range Reflected ripple current Conditions Continuous operation, 3V input types Continuous operation, 5V input types Continuous operation, 12V input types Min. 2.97 4.5 10.8 Typ. 3.3 5 12 41 Max. 3.63 5.5 13.2 50 Units V mA p-p ISOLATION CHARACTERISTICS Parameter Isolation voltage Resistance Conditions Flash tested for 1 second Viso= 1000VDC Min. 1000 10 Typ. Max. Units VDC GΩ GENERAL CHARACTERISTICS PRODUCT OVERVIEW The NTA series of miniature surface mounted DC/DC Converters employ leadframe technology and transfer moulding techniques to bring all of the benefits of IC style packaging to hybrid circuitry. Co-planarity of the lead positions is based upon IEC 191-6:1990. The devices are suitable for all applications where high volume production is envisaged. Parameter Switching frequency Conditions 0312MC, 0315MC 0303MC, 0305MC, 0503MC, 0505MEC All other variants Min. Typ. 100 110 115 Max. Units kHz ABSOLUTE MAXIMUM RATINGS Short-circuit protection3 Lead temperature 1.5mm from case for 10 seconds Internal power dissipation Input voltage VIN, NTA03 types Input voltage VIN, NTA05 types Input voltage VIN, NTA12 types 1 second 300°C 700mW 5.5V 7V 15V   1. If components are required in tape and reel format suffix order code code with -R, e.g. NTA0505MC-R. 2. Calculated using MIL-HDBK-217F with nominal input voltage at full load. 3. Supply voltage must be disconnected at the end of the short circuit duration. All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified. For full details go to www.murata-ps.com/rohs www.murata-ps.com Technical enquiries - email: mk@murata-ps.com, tel: +44 (0)1908 615232 KDC_NTA.G04 Page 1 of 4 NTA Series Isolated 1W Dual Output SM DC/DC Converters OUTPUT CHARACTERISTICS Parameter Rated Power Voltage Set Point Accuracy Line regulation Conditions TA=-40°C to 85°C See tolerance envelope High VIN to low VIN 10% load to rated load, 0303MC & 0503MC 10% load to rated load, 5V output types 10% load to rated load, 0309MC 10% load to rated load, 0509MC & 1209MC 10% load to rated load, 0312MC & 0315MC 10% load to rated load, 0512MC & 1212MC 10% load to rated load, 0515MC & 1215MC BW=DC to 20MHz, 3.3V output types, NTA0305MC & NTA0505MEC BW=DC to 20MHz, all other 5V output types BW=DC to 20MHz, 9V output types BW=DC to 20MHz, 12V output types BW=DC to 20MHz, 15V output types Min. Typ. Max. 1.0 Units W %/% Load Regulation1 Ripple and Noise 1.0 10 10 9.0 6.5 11 6.0 6.0 40 50 35 50 65 1.2 15 12 10 8.0 14 8.5 7.0 80 100 80 110 110 % mV p-p TEMPERATURE CHARACTERISTICS Parameter Specification Storage Case temperature rise above ambient Cooling Conditions All output types 0305MC, 0505MEC, 0312MC, 0315MC 0303MC, 0309MC, 0503MC 0505MC, 1205MC All other variants Free air convection Min. -40 -55 Typ. Max. 85 125 Units 19 25 46 35 °C TECHNICAL NOTES ISOLATION VOLTAGE ‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Murata Power Solutions NTA series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second. A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?” For a part holding no specific agency approvals, such as the NTA series, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard requirements. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. The NTA series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage. This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further insulation system of physical spacing or barriers. TEMPERATURE DERATING GRAPH 1.5 RoHS COMPLIANCE INFORMATION This series is compatible with RoHS soldering systems with a peak reflow solder temperature of 245ºC and time above liquidus of 217ºC for 80 seconds. The pin termination finish on this product series is Gold, plating thickness 0.1 microns minimum. The series is backward compatible with Sn/Pb soldering systems. For further information, please visit www.murata-ps.com/rohs 150 Output Power (W) 1.0 0.5 0 -40 85°C Safe Operating Area 100 50 0 Ambient Temperature (°C) 1. 12V input types have typically 3% less load regulation change. www.murata-ps.com Technical enquiries - email: mk@murata-ps.com, tel: +44 (0)1908 615232 KDC_NTA.G04 Page 2 of 4 NTA Series Isolated 1W Dual Output SM DC/DC Converters TOLERANCE ENVELOPES Tolerance Envelope - 3.3V output types. +9% Typical L oad Lin All other types. +10% e +1% VNOM +1% -7% -15% +5% VNOM Typical L oad Line +2.5% -2.5% -7.5% Output Voltage -7% Output Voltage 10 75 50 25 Output Load Current (%) 100 10 75 50 25 Output Load Current (%) 100 PACKAGE SPECIFICATIONS MECHANICAL DIMENSIONS 0.600 (15.24) PIN CONNECTIONS Pin 0.400 (10.16) 18 16 14 12 10 Function -VIN +VIN NA OV -VOUT NA 1 3 REFERENCE PLANE P 0.441 0.409 (11.20) (10.40) 0.303 (7.70) 0.020(0.5) 5 7 9 10 NTA0505MC XYYWW 5 7 1 3 9 0.059(1.50) 0.047(1.20) 10 PINS 0.008(0.2) S ±5.00 ° 0.100(2.54) 0.026(0.65) 0.022(0.55) 12 14 16 +VOUT NA NA 0.083 (2.10) 0.260 (6.6) 0.250 (6.35) 0.234 (5.95) 0.230 (5.85) 0.010 (0.25) 0.004 (0.10) DETAIL A S SEATING PLANE 18 NA NA - Not available for electrical connection. 0.11 (2.79) MAX 10 PINS 0.004 (0.1) S 0.074 (1.875) MAX 0.012 (0.30) 0.008 (0.20) All dimensions in inches ±0.01 (mm ±0.25mm). All pins on a 0.1 (2.54) pitch. Weight: 1.53g RECOMMENDED FOOTPRINT DETAILS TUBE OUTLINE DIMENSIONS Unless otherwise stated all dimensions in inches ±0.02 (mm±0.5). Tube length : 18.70±0.07 (475±2.0). Tube Quantity : 25 www.murata-ps.com Technical enquiries - email: mk@murata-ps.com, tel: +44 (0)1908 615232 KDC_NTA.G04 Page 3 of 4 NTA Series Isolated 1W Dual Output SM DC/DC Converters TAPE & REEL SPECIFICATIONS REEL OUTLINE DIMENSIONS TAPE OUTLINE DIMENSIONS REEL PACKAGING DETAILS NTA0505MC NTA0505MC NTA0505MC Product Orientation Pin 1, located nearest to carrier drive sprocket. Reel Quantity : 500 TRAILER SECTION 6.30 (160) MIN XYYWW XYYWW XYYWW GOODS ENCLOSURE SECTION CARRIER TAPE START 3.94 (100) MIN LEADER SECTION 15.75 (400) MIN USA: UK: France: Japan: Tucson (Az), Tel: (800) 547 2537, email: sales@murata-ps.com Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com Website: www.murata-ps.jp Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com Canada: Toronto, Tel: (866) 740 1232, email: toronto@murata-ps.com Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356 www.murata-ps.com email: sales@murata-ps.com ISO 9001 REGISTERED Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2008 Murata Power Solutions, Inc. Germany: München, Tel: +49 (0)89-544334-0, email: munich@murata-ps.com China: www.murata-ps.com Technical enquiries - email: mk@murata-ps.com, tel: +44 (0)1908 615232 KDC_NTA.G04 Page 4 of 4
NTA1215MC 价格&库存

很抱歉,暂时无法提供与“NTA1215MC”相匹配的价格&库存,您可以联系我们找货

免费人工找货