0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
ACTP212

ACTP212

  • 厂商:

    NAIS(松下)

  • 封装:

    DIP

  • 描述:

    RELAY AUTOMOTIVE SPDTX2 30A 12V

  • 数据手册
  • 价格&库存
ACTP212 数据手册
CT (ACTP) POWER TYPE SMALL & SLIM AUTOMOTIVE RELAY 17.4 .685 14 .551 13.5 .531 17.4 .685 7.2 .283 13.5 .531 CT RELAYS FEATURES APPLICATIONS 1. Compact type for automotives We successfully developed a power type that is the same size as our CT relay. 2. 30 A maximum switching capacity Switching of 30 A motor loads is possible due to change of COM spring material and other improvements. 3. Still top-of-its-class for silent operation Maintains equally silent operation as our CT relay (ACT). 4. Sealed type Sealed type makes automatic cleaning possible. Power windows, Powered seats, Auto door lock, Slide door closers, Power sunroof, etc. 10-terminal layout Contact terminal Coil terminal *8-terminal type has no terminals. SPECIFICATIONS Contact Characteristics Arrangement Contact material Initial contact resistance (Initial) (By voltage drop 6 V DC 1 A) Nominal switching capacity Rating Max. carrying current (N.O.) Min. switching capacity Mechanical (at 120 cpm) Resistive load Expected life (min. operation) Electrical Motor load #1 1 Form C2, 1 Form C Ag alloy (Cadmium free) Typ. 7 m (N.O.) Typ. 10 m (N.C.) N.O.: 30 A 14 V DC N.C.: 10 A 14 V DC 40 A for 2 minutes, 25 A for 1 hour (at 20C 68F) 35 A for 2 minutes, 20 A for 1 hour (at 85C 185F) 1 A 12 V DC Min. 106 Min. 5104*1 Min. 105*2 (free) Min. 5104*3 (lock) Coil Nominal operating power 1,000 mW #1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. Max. operating speed (at nominal switching capacity) Initial insulation resistance*4 Between open Initial contacts breakdown Between contacts voltage*5 and coil Operate time*6 (at nominal voltage) (at 20C 68F) Release time*6 (at nominal voltage) (at 20C 68F) Functional*7 Shock resistance Destructive*8 Vibration resistance *1 At nominal switching capacity, operating frequency: 1s ON, 9s OFF *2 N.O.: at 7 A (steady), 30 A (inrush)/N.C.: at 15 A (brake) 14 V DC, operating frequency: 0.5s ON, 9.5s OFF *3 At 30A 14 V DC (Motor lock), operating frequency: 0.5s ON, 9.5s OFF 4 * Measurement at same location as “Initial breakdown voltage” section *5 Detection current: 10mA *6 Excluding contact bounce time *7 Half-wave pulse of sine wave: 11ms; detection: 10s *8 Half-wave pulse of sine wave: 6ms *9 Detection time: 10s *10 Time of vibration for each direction; X, Y, direction: 2 hours Y X Z direction: 4 hours Destructive*10 Conditions for Ambient operation, transport and temp storage*11 (Not freezing and condensing at low Humidity temperature) Mass Remarks Functional*9 6 cpm Min. 100 M (at 500 V DC) 500 Vrms for 1 min. 500 Vrms for 1 min. Max. 10ms (Initial) Max. 10ms (Initial) Min. 100 m/s2 {10G} Min. 1,000 m/s2 {100G} 10 Hz to 100 Hz, Min. 44.1m/s2 {4.5G} 10 Hz to 500 Hz, Min. 44.1m/s2 {4.5G} –40C to +85C –40F to +185F 5% R.H. to 85% R.H. Twin type: approx. 8.0g .28oz 1 Form C type: approx. 4.0g .14oz Z *11 Refer to “6. Usage, Storage and Transport Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information. Please inquire if you will be using the relay in a high temperature atmosphere (110C 230F). * If the relay is used continuously for long periods of time with coils on both sides in an energized condition, breakdown might occur due to abnormal heating depending on the carrying condition. Therefore, please inquire when using with a circuit that causes an energized condition on both sides simultaneously. ds_61205_en_ct_power: 010611J 1 CT (ACTP) TYPES AND COIL DATA (at 20C 68F) Standard packing; 1 Form C: Carton(tube package) 30pcs. Case 1,500pcs. 1 Form C  2: Carton(tube package) 30pcs. Case 900pcs. Contact arrangement 1 Form C 1 Form C  2 (8 terminals type) 1 Form C  2 (10 terminals type) 12 Pick-up voltage, V DC (Initial) Max. 7.2 Drop-out voltage, V DC (Initial) Min. 1.0 ACTP212 12 Max. 7.2 ACTP512 12 Max. 7.2 Part No. Nominal voltage, V DC ACTP112 Coil resistance,  Nominal operating current, mA Nominal Usable operating power, voltage range, mW V DC 14410% 83.310% 1,000 10 to 16 Min. 1.0 14410% 83.310% 1,000 10 to 16 Min. 1.0 14410% 83.310% 1,000 10 to 16 * Other pick-up voltage types are also available. Please contact us for details. DIMENSIONS(mm inch) Download CAD CAD Data Data from our Web site. 1. Twin type (8 terminals) 17.4 .685 CAD Data 14 .551 PC board pattern (Bottom view) 9.5 .374 6 .236 13.5 .531 0.4 .016 Max. 1.0 .039 3.5 .138 1.25 .049 1 .039 6 .236 1 .039 0.8 .031 0.3 .012 9.5 .374 4.3 .169 4.3 .169 2.5 .098 4.3 .169 3 6.8 .118 .268 3.15 .124 15 .591 +0.1 15 .591 +0.1 0.4 0.4 .016 .016 4-1.4 0 dia. 4-.055 +0.04 dia. 0 4-1.1 0 dia. 4-.043 +0.04 dia. 0 Tolerance: 0.1.004 Pre-soldering 1 .039 1.45 .057 2.5 .098 3 6.8 .118 .268 3.15 .124 *A 0.4 .016 4.3 .169 Schematic (Bottom view) COIL COM Dimension: Tolerance Max. 1mm .039 inch: 0.1 .004 1 to 3mm .039 to .118 inch: 0.2 .008 Min. 3mm .118 inch: 0.3 .012 NC NO COIL COM * Dimensions (thickness and width) of terminal specified in this catalog is measured before pre-soldering. Intervals between terminals is measured at A surface level. 2. Twin type (10 terminals) 17.4 .685 CAD Data 14 .551 PC board pattern (Bottom view) 9.5 .374 6 .236 13.5 .531 3.5 .138 0.4 .016 1.25 .049 1 .039 9.5 .374 4.3 .169 +0.1 0.8 .031 0.3 .012 0.4 0.4 .016 .016 0.65 .026 Pre-soldering 6-1.4 dia. 6-.055 dia. Tolerance: 0.1 .004 Schematic (Bottom view) 4.3 .169 2.5 .098 4.3 .169 15 .591 4-1.1 0 dia. 4-.043 +0.04 dia. 0 15 .591 +0.1 0 +0.04 0 6 .236 3.15 .124 0.65 6.8 .026 .268 3.15 .124 1.45 .057 0.65 1 .026 .039 2.5 .098 0.65 6.8 .026 .268 3.15 .124 *A 1 .039 4.3 .169 3.15 .124 Max. 1.0 .039 0.4 .016 NO COIL Dimension: Tolerance Max. 1mm .039 inch: 0.1 .004 1 to 3mm .039 to .118 inch: 0.2 .008 Min. 3mm .118 inch: 0.3 .012 NC COM NO COIL COM NC * Dimensions (thickness and width) of terminal specified in this catalog is measured before pre-soldering. Intervals between terminals is measured at A surface level. 2 ds_61205_en_ct_power: 010611J CT (ACTP) 3. Single type (1 Form C) mm inch 7.2 .283 17.4 .685 CAD Data PC board pattern (Bottom view) +0.1 3-1.4 0 dia. 3-.055 +0.04 dia. 0 13.5 .531 0.4 .016 Max. 1.0 .039 3.5 .138 1.25 .049 1 .039 6 .236 1 .039 +0.1 9.5 .374 15 .591 0.4 0.4 .016 .016 Pre-soldering 1 .039 4.3 .169 3.15 .124 1.45 0.65 .057 .006 0.65 .026 0.8 .031 0.3 .012 4.3 .169 3.15 .124 *A 0.4 .016 15 .591 9.5 .374 6 .236 2-1.1 0 dia. 2-.043 +0.04 dia. 0 Tolerance: 0.1.004 Schematic (Bottom view) NO Dimension: Tolerance Max. 1mm .039 inch: 0.1 .004 1 to 3mm .039 to .118 inch: 0.2 .008 Min. 3mm .118 inch: 0.3 .012 COM COIL NC * Dimensions (thickness and width) of terminal specified in this catalog is measured before pre-soldering. Intervals between terminals is measured at A surface level. EXAMPLE OF CIRCUIT Forward/reverse control circuits of DC motor for power windows NO COM COM M 12 V DC NO NC NC SW A SW B M : Power window motor REFERENCE DATA 1-(2). Coil temperature rise (at 85C 185F) Sample: ACTP212, 3pcs. Contact carrying current: 0A, 10A, 20A Sample: ACTP212, 3pcs. Contact carrying current: 0A, 10A, 20A 160 Temperature rise, °C 120 10A 0A 100 80 60 Temperature rise, °C 20A 140 2. Ambient temperature and operating voltage range 160 40 140 35 20A 120 100 10A 0A 80 60 Coil applied voltage, VDC 1-(1). Coil temperature rise (at room temperature) 30 25 20 15 40 40 10 20 20 5 0 0 12 14 16 Coil applied voltage, V ds_61205_en_ct_power: 010611J 12 14 16 Coil applied voltage, V 0 -40 -20 0 Pick-up voltage (Cold start) 20 40 60 80 85 100 120 Ambient temperature, °C 3 CT (ACTP) 3. Distribution of pick-up and drop-out voltage 4. Distribution of operate and release time Sample: ACTP212, 40pcs. Sample: ACTP212, 40pcs. * Without diode 60 50 Pick-up voltage Drop-out voltage 50 Quantity, n Frequency 40 30 Operate time Release time 40 30 20 20 10 0 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 0 1 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 Operate and release time, ms Voltage, V Sample: ACTP212, 3pcs. Load: 7A steady, Inrush 30A Brake current: 15A 14V DC, Power window motor actual load (free condition) Operating frequency: (ON : OFF = 0.5s : 9.5s) Ambient temperature: Room temperature Circuit: Circuit Sample Pick-up and drop-out voltage, V Change of pick-up and drop-out voltage 5. Electrical life test (Motor free) 10 50 Contact welding: 0 time Miscontact: 0 time 8 Pick-up voltage 6 Max. X Min. 4 Drop-out voltage Max. X Min. 2 M Change of contact resistance 0 0 5 No. of operations, × 104 10 Contact resistance, mΩ 0 10 40 30 20 10 0 Max. X Min. 0 5 10 No. of operations, × 104 Load current waveform Inrush current: 30A, Steady current: 7A Brake current: 15A 10A 100ms 4 ds_61205_en_ct_power: 010611J CT (ACTP) Change of pick-up and drop-out voltage Circuit: Sample M 10 Change of contact resistance 50 Contact welding: 0 time Miscontact: 0 time 8 Pick-up voltage 6 Max. X Min. 4 Drop-out voltage 2 0 0 2.5 No. of operations, × 104 Max. X Min. 5 Contact resistance, mΩ Sample: ACTP212, 3pcs. Load: 30A 14V DC Switching frequency: (ON : OFF = 0.5s : 9.5s) Ambient temperature: Room temperature Pick-up and drop-out voltage, V 6. Electrical life test (Motor lock) 40 30 20 10 0 Max. X Min. 0 2.5 5 No. of operations, × 104 Load current waveform 10A 100ms For Cautions for Use, see Relay Technical Information. ds_61205_en_ct_power: 010611J 5
ACTP212 价格&库存

很抱歉,暂时无法提供与“ACTP212”相匹配的价格&库存,您可以联系我们找货

免费人工找货
ACTP212
  •  国内价格
  • 1+42.01984
  • 8+41.09300
  • 15+40.22866

库存:31

ACTP212

库存:33