TV-4 rated.
2 Form A 3A/5A
power relays
LA RELAYS (ALA)
FEATURES
1. 2 Form A slim type
24(L) × 12(W) × 25(H) mm
.945(L)×.472(W)×.984(H) inch
2. 3A type and 5A TV type
3A type: Contact reliability and break
performance best suited for protecting
and switching speakers.
5A TV type: Tough against inrush current
and optimal for turning on and off the
power supply. Rated TV-4 (UL, CSA).
3. Long insulation distance
• Creepage distance and clearances
between contact and coil: Min. 6 mm .236
inch (In compliance with IEC65)
• Surge withstand voltage between
contact and coil: 10,000 V
RoHS compliant
Protective construction: Flux-resistant
type
4. High noise immunity realized by the
card separation structure between
contact and coil
5. Conforms to the various safety
standards
• UL, CSA, VDE, TÜV, SEMKO approved
TYPICAL APPLICATIONS
• Audio devices
• Monitor
• Automatic vending machine
ORDERING INFORMATION
ALA
2
F
LA relay
Contact arrangement
2: 2 Form A
Contact capacity
Nil: 3A
P: 5A TV-4
Protective construction
F: Flux-resistant type
Nominal coil voltage (DC)
12: 12V, 24: 24V
Note: Certified by UL, CSA, VDE, TÜV, SEMKO and TV-4
TYPES
Contact arrangement
Coil voltage
2 Form A
12V DC
24V DC
Part No.
3A type
ALA2F12
ALA2F24
5A TV type (TV-4)
ALA2PF12
ALA2PF24
Standard packing Carton: 100 pcs. Case: 500 pcs.
Note: 4.5V, 5V, 6V, 9V and 18V DC types are also available. Please consult us for details.
–1–
ASCTB191E 201605-T
LA (ALA2)
RATING
1. Coil data
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
12V DC
75%V or less of
nominal voltage
(Initial)
5%V or more of
nominal voltage
(Initial)
24V DC
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
44.2mA
272Ω
22.1mA
1,087Ω
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
15.6V DC
530mW
31.2V DC
2. Specifications
Characteristics
Specifications
Item
3A type
5A TV type (TV-4)
2 Form A
Max. 50 mΩ (By voltage drop 6V DC 1A)
Max. 100 mΩ (By voltage drop 6V DC 1A)
Gold-clad, AgNi type
AgSnO2 type
3A 125V AC
5A 277V AC
625VA
1,385VA
125V AC
277V AC
5A (AC)
100mA 5V DC
Arrangement
Contact resistance (Initial)
Contact material
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
Max. switching current
Min. switching capacity (reference value)*1
Contact
Rating
Insulation resistance (Initial)
Electrical
characteristics
Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Between contact sets
Breakdown voltage
Between open contacts
(Initial)
Between contact and coil
Surge breakdown voltage*2
(Between contact and coil) (Initial)
Operate time (at nominal voltage) (at 20°C 68°F)
(Initial)
Release time (at nominal voltage) (at 20°C 68°F)
(Initial)
1,000 Vrms for 1 min. (Detection current: 10 mA)
1,000 Vrms for 1 min. (Detection current: 10 mA)
4,000 Vrms for 1 min. (Detection current: 10 mA)
10,000 V
Max. 15 ms (excluding contact bounce time.)
Max. 15 ms (excluding contact bounce time) (With diode)
200 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10μs.)
1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10μs.)
10 to 55 Hz at double amplitude of 1.5 mm
Min. 106 (at 180 times/min.)
Min. 5×104 (ON: OFF=1.5s: 1.5s) (at nominal switching capacity)
Ambient temperature: –40°C to +70°C –40°F to +158°F,
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature),
Air pressure: 86 to 106kPa
20 times/min. (at nominal switching capacity)
Approx. 13 g .46 oz
Functional
Destructive
Functional
Vibration resistance
Destructive
Mechanical
Electrical (at 20 times/min.)
Shock resistance
Mechanical
characteristics
Expected life
Conditions
Conditions for operation, transport and storage*3
Max. operating speed
Unit weight
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50μs according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
REFERENCE DATA
1. Max. switching power (AC resistive load)
2-(2). Life curve (125 V AC resistive load)
5A TV type (ALA2PF)
100
100
10
5A TV type (ALA2PF)
3
250V AC resistive load
10
Life, ×104
125V AC resistive load
5
Life, ×104
Contact current, A
2-(1). Life curve (250 V AC resistive load)
3A type (ALA2F)
10
3A type (ALA2F)
0
100
300
Contact voltage, V
1
1
0
1
2
3
4
Contact current, A
–2–
5
0
1
2
3
Contact current, A
ASCTB191E 201605-T
LA (ALA2)
3-(1). Coil temperature rise
3-(2). Coil temperature rise
Sample: ALA2F12, 6 pcs.
Measured portion: coil inside
Contact current: 0 A, 3A
Sample: ALA2PF12, 6 pcs.
Measured portion: coil inside
Contact current: 0 A, 5A
50
70°C 3A
70°C 0A
30
25
20
40
30
25
20
15
15
10
10
5
5
0
80
100
0
120
0
Coil applied voltage, %V
Sample: ALA2F12, 6 pcs.
Operation frequency: 20 times/min.
(ON/OFF = 1.5s: 1.5s)
Ambient temperature: 20°C 68°F
Circuit:
12V DC
125V AC
NO
COM
NO
COM
Contact
welding
detection
and Miscontacting
detection
circuit
5-(2). Electrical life test
(5 A 250 V AC, resistive load)
NO
COM
NO
COM
Pick-up and drop-out voltage, %V
12V DC
Contact
welding
detection
and Miscontacting
detection
circuit
80
Pick-up voltage
40
Drop-out voltage
Tested sample: ALA2PF12, 6 pcs.
• Overload test
Load: 6.0 A 120 V AC (60 Hz),
Inrush: 91 A
Operation frequency: 10 times/min
(ON: OFF = 1 s: 5 s)
No. of operations: 50 ope.
• Endurance test
Load: 4A 120 V AC (60 Hz),
Inrush: 65 A
Operation frequency: 10 times/min
(ON: OFF = 1 s: 5 s)
No. of operations: 25,000 ope.
Max.
x
Min.
20
2.5
No. of operations, ×104
40
60
Ambient temperature, °C
80
40
30
Max.
x
Min.
20
10
0
0
5
2.5
No. of operations, ×104
5
Change of contact resistance
50
80
Pick-up voltage
60
Max.
x
Min.
40
40
Max.
30
x
Min.
20
Drop-out voltage
Max.
x
Min.
20
2.5
No. of operations, ×104
10
0
0
5
2.5
5
No. of operations, ×104
Change of pick-up and drop-out voltage
Pick-up and drop-out voltage, %V
5-(3). Electrical life test
(UL lamp load test TV-4)
Max.
x
Min.
60
0
0
G
20
50
100
Circuit:
100
Change of contact resistance
Change of pick-up and drop-out voltage
Sample: ALA2PF12, 6 pcs.
Operation frequency: 20 times/min.
(ON/OFF = 1.5s: 1.5s)
Ambient temperature: 20°C 68°F
150
0
0
100
120
Coil applied voltage, %V
100
0
0
G
250V AC
80
Change of pick-up and drop-out voltage
Pick-up and drop-out voltage, %V
5-(1). Electrical life test
(3 A 125 V AC, resistive load)
Allowable ambient temperatures
against % coil voltages
(max. inside the coil
temperature set as
115°C 239°F)
50
Contact resistance, mΩ
0
70°C 5A
70°C 0A
35
Change of contact resistance
50
100
80
Pick-up voltage
Max.
x
Min.
60
40
Drop-out voltage
20
0
0
Max.
x
Min.
2.5
No. of operations, ×104
–3–
Contact resistance, mΩ
35
Temperature rise, °C
Temperature rise, °C
40
200
20°C 5A
20°C 0A
45
Coil applied voltage, %V
20°C 3A
20°C 0A
45
Contact current: ALA2F=3A
ALA2PF=5A
Contact resistance, mΩ
50
4. Ambient temperature characteristics and coil
applied voltage
40
30
20
Max.
10
x
Min.
0
0
2.5
No. of operations, ×104
ASCTB191E 201605-T
LA (ALA2)
DIMENSIONS (mm inch)
The CAD data of the products with a
CAD Data
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
External dimensions
CAD Data
PC board pattern (Bottom view)
2-0.9 dia.
2-.035 dia.
15.0
.591
5.0
.197
Max. 25.0
.984
4-1.3 dia.
4-.051 dia.
7.5
.295
0.5
.020
Tolerance : ±0.1 ±.004
0.5 dia.
.020 dia.
1.65
.065
4
.157
0.3
.012
Max. 24
5.0
.945
.197
15.0
.591
0.4
.016
Max. 12
.472
1.0
.039
7.5
.295
1.0
.039
Schematic (Bottom view)
1.0
.039
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch:
Min. 3mm .118 inch:
General tolerance
±0.1 ±.004
±0.2 ±.008
±0.3 ±.012
SAFETY STANDARDS
Item
UL (Recognized)
CSA (Certified)
File No. Contact rating Cycles
File No. Contact rating
3A
type
E43149 3A 125V AC
3A 30V DC
5A 50V DC
5A TV E43149 5A 277V AC
type
5A 30V DC
105 LR26550 3A 125V AC
6 × 103
3A 30V DC
6 × 103
5A 50V DC
6 × 103 LR26550 5A 277V AC
6 × 103
5A 30V DC
VDE (Certified)
File No.
TÜV (Certified)
Contact rating
40012000 3A 125V AC (cosφ =1.0)
3A 30V DC (0ms)
—
40012000 5A 250V AC (cosφ =1.0)
5A 30V DC (0ms)
Temp.
Cycles
70°C 158°F
70°C 158°F
—
70°C 158°F
70°C 158°F
104
104
—
104
104
File No.
Contact rating
B 12 06
3A 125V AC (cosφ =1.0)
13461 324 3A 30V DC (0ms)
—
B 12 06
5A 250V AC (cosφ =1.0)
13461 324 5A 30V DC (0ms)
TV rating (UL/CSA)
Cycles
104
104
—
104
104
File No.
Contact
rating
—
—
UL: E43149
CSA: LR26550
TV-4
TV-4
EN/IEC VDE Certified
INSULATION CHARACTERISTIC (IEC61810-1)
Item
Clearance/Creepage distance (IEC61810-1)
Category of protection (IEC61810-1)
Tracking resistance (IEC60112)
Insulation material group
Over voltage category
Rated voltage
Pollution degree
Type of insulation (Between contact and coil)
Type of insulation (Between open contacts)
Characteristic
Min. 5.5mm/5.5mm
RT II
PTI 175
III a
III
250V
2
Reinforced insulation
Micro disconnection
NOTES
1. For cautions for use, please read
“GENERAL APPLICATION
GUIDELINES”.
–4–
ASCTB191E 201605-T