0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
ERZ-E11F112

ERZ-E11F112

  • 厂商:

    NAIS(松下)

  • 封装:

    DIP

  • 描述:

    VARISTOR 990V 5KA DISC 14MM

  • 数据手册
  • 价格&库存
ERZ-E11F112 数据手册
Varistors (ZNR Surge Absorber) D type E series Varistors (ZNR Surge Absorber), Series E, Type D features large surge current and energy handling capability for absorbing transient overvoltage in a compact size. Features ●Large withstanding surge current capability in compact sizes ●Large “Energy Handling Capability” absorbing transient overvoltages in compact sizes ●Wide range of varistor voltages ●RoHS compliant Recommended applications ●Transistor, diode, IC, thyristor or triac semiconductor protection ●Surge protection in consumer electronic equipment ●Surge protection in communication, measuring or controller electronics ●Surge protection in electronic home appliances, gas or petroleum appliances Applicable standards ●UL1449 (VZCA2/UL, VZCA8/C-UL) ●VDE IEC61051-1,-2,-2-2,IEC60950-1 Annex.Q, IEC62368-1 G8.2 ●CQC (GB/T10193, GB/T10194, GB4943.1, GB8898) Refer to "Standard Products" , and "Application Note for Safety Standards" , for the details. Refer to "Standard Products" , and "Application Note for Safety Standards" , for the details. ■As for handling precautions and minimum quantity / Packing unit please see related information. Explanation of part numbers 1 2 3 4 5 6 E R Z E     7 8 9   10   Product code 11 12     Design No. Code Series E05 E5 Code Configuration Packaging E07 E7 A Straight lead Bulk E08 E8 B*1 Crimped lead Bulk E10 E10 E *2 Straight lead Taped E11 E11 F *2 Crimped lead Taped E14 E14 Lead configuration Norminal varistor voltage The first two digits are significant figures and the third one denotes the number of zeros following. *1: Excluding E14, only the lead cut *2: Excluding E14 Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20 D type / E series Reference guide to standard products Applicable standards Part No. Type name Approvals Varistor voltage at 1 mA (V) Maximum allowable voltage Acrms (V) DC (V) Maximum peak current at 8/20 μs (A) Clamping voltage at 8/20 μs max.(V) lp (A) 1time 2times ERZE05A201 E201 ○☆◇ 340 10 1200 600 ERZE07A201 E7201 ○☆◇ 340 25 2500 1250 ERZE08A201 E8201 ○☆◇ 340 25 3500 2500 ERZE10A201 E10201 ○☆◇ 340 50 4500 3000 ERZE11A201 E11201 ○☆★◇◆ 340 50 6000 5000 ERZE14A201 E14201 ○☆★◇◆ 340 100 10000 7000 ERZE05A221 E221 ○☆◇ 360 10 1200 600 ERZE07A221 E7221 ○☆◇ 360 25 2500 1250 ERZE08A221 E8221 ○☆◇ 360 25 3500 2500 ERZE10A221 E10221 ○☆◇ 360 50 4500 3000 ERZE11A221 E11221 ○☆★◇◆ 360 50 6000 5000 ERZE14A221 E14221 ○☆★◇◆ 360 100 10000 7000 ERZE05A241 E241 ○☆◇ 395 10 1200 600 ERZE07A241 E7241 ○☆◇ 395 25 2500 1250 ERZE08A241 E8241 ○☆◇ 395 25 3500 2500 ERZE10A241 E10241 ○☆◇ 395 50 4500 3000 ERZE11A241 E11241 ○☆★◇◆ 395 50 6000 5000 ERZE14A241 E14241 ○☆★◇◆ 395 100 10000 7000 ERZE05A271 E271 ○☆◇ 455 10 1200 600 ERZE07A271 E7271 ○☆◇ 455 25 2500 1250 ERZE08A271 E8271 ○☆◇ 455 25 3500 2500 ERZE10A271 E10271 ○☆◇ 455 50 4500 3000 ERZE11A271 E11271 ○☆★◇◆ 455 50 6000 5000 ERZE14A271 E14271 ○☆★◇◆ 455 100 10000 7000 ERZE05A331 E331 ○☆◇ 545 10 1200 600 ERZE07A331 E7331 ○☆◇ 545 25 2500 1250 ERZE08A331 E8331 ○☆◇ 545 25 3500 2500 ERZE10A331 E10331 ○☆◇ 545 50 4500 3000 ERZE11A331 E11331 ○☆★◇◆ 545 50 6000 4500 ERZE14A331 E14331 ○☆★◇◆ 545 100 10000 6500 ERZE05A361 E361 ○☆◇ 595 10 1200 600 ERZE07A361 E7361 ○☆◇ 595 25 2500 1250 ERZE08A361 E8361 ○☆◇ 595 25 3500 2500 ERZE10A361 E10361 ○☆◇ 595 50 4500 3000 ERZE11A361 E11361 ○☆★◇◆ 595 50 6000 4500 ERZE14A361 E14361 ○☆★◇◆ 595 100 10000 6500 ERZE05A391 E391 ○☆◇ 650 10 1200 600 ERZE07A391 E7391 ○☆◇ 650 25 2500 1250 ERZE08A391 E8391 ○☆◇ 650 25 3500 2500 ERZE10A391 E10391 ○☆◇ 650 50 4500 3000 ERZE11A391 E11391 ○☆★◇◆ 650 50 6000 4500 ERZE14A391 E14391 ○☆★◇◆ 650 100 10000 6500 ERZE05A431 E431 ○☆◇ 710 10 1200 600 ERZE07A431 E7431 ○☆◇ 710 25 2500 1250 ERZE08A431 E8431 ○☆◇ 710 25 3500 2500 ERZE10A431 E10431 ○☆◇ 710 50 4500 3000 ERZE11A431 E11431 ○☆★◇◆ 710 50 6000 4500 ERZE14A431 E14431 ○☆★◇◆ 710 100 10000 6500 200 (185 to 225) 220 (198 to 242) 240 (216 to 264) 270 (247 to 303) 330 (297 to 363) 360 (324 to 396) 390 (351 to 429) 430 (387 to 473) 130 140 150 175 210 230 250 275 170 180 200 225 270 300 320 350 ○: UL1449 (VZCA2/UL, VZCA8/C-UL), ☆ : VDE (IEC61051-1, -2, -2-2) ★ : VDE (IEC60950-1 Annex.Q, IEC62368-1 G8.2 ), ◇: CQC (GB/T10193, GB/T10194), ◆ : CQC (GB4943.1, GB8898) ※Approval number (File No.) of safety regulations are subject to revision without notice. Ask factory for a copy of the latest file No. Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20 D type / E series Reference guide to standard products Applicable standards Part No. Type name Approvals Varistor voltage at 1 mA (V) Maximum allowable voltage Acrms (V) DC (V) Clamping voltage at 8/20 μs max.(V) Maximum peak current at 8/20 μs (A) lp (A) 1time 2times ERZE05A471 E471 ○☆◇ 775 10 1200 600 ERZE07A471 E7471 ○☆◇ 775 25 2500 1250 ERZE08A471 E8471 ○☆★◇◆ 775 25 3500 2500 ERZE10A471 E10471 ○☆★◇◆ 775 50 4500 3000 ERZE11A471 E11471 ○☆★◇◆ 775 50 6000 4500 ERZE14A471 E14471 ○☆★◇◆ 775 100 10000 6500 ERZE07A511 E7511 ○☆◇ 845 25 2500 1250 ERZE08A511 E8511 ○☆★◇◆ 845 25 3500 2500 ERZE10A511 E10511 ○☆★◇◆ 845 50 4500 3000 ERZE11A511 E11511 ○☆★◇◆ 845 50 6000 4500 ERZE14A511 E14511 ○☆★◇◆ 845 100 10000 6500 ERZE07A561 E7561 ○☆◇ 930 25 2500 1250 ERZE08A561 E8561 ○☆★◇◆ 930 25 3500 2500 ERZE10A561 E10561 ○☆★◇◆ 930 50 4500 3000 ERZE11A561 E11561 ○☆★◇◆ 930 50 6000 4500 ERZE14A561 E14561 ○☆★◇◆ 930 100 10000 6500 ERZE07A621 E7621 ○☆◇ 1025 25 2500 1250 ERZE08A621 E8621 ○☆★◇◆ 1025 25 3500 2500 ERZE10A621 E10621 ○☆★◇◆ 1025 50 4500 3000 ERZE11A621 E11621 ○☆★◇◆ 1025 50 5000 4500 470 (423 to 517) 510 (459 to 561) 560 (504 to 616) 620 (558 to 682) 300 320 350 385 385 410 450 505 ERZE14A621 E14621 ○☆★◇◆ 1025 100 7500 6500 ERZE08A681 E8681 ○☆★◇◆ 1120 25 3500 2500 ERZE10A681 E10681 ○☆★◇◆ 1120 50 4500 3000 ERZE11A681 E11681 ○☆★◇◆ 1120 50 5000 4500 ERZE14A681 E14681 ○☆★◇◆ 1120 100 7500 6500 ERZE08A751 E8751 ○☆★◇◆ 1240 25 3500 2500 ERZE10A751 E10751 ○☆★◇◆ 1240 50 4500 3000 ERZE11A751 E11751 ○☆★◇◆ 1240 50 5000 4500 ERZE14A751 E14751 ○☆★◇◆ 1240 100 7500 6500 ERZE10A821 E10821 ○☆★◇◆ 1355 50 4500 3000 ERZE11A821 E11821 ○☆★◇◆ 1355 50 5000 4500 ERZE14A821 E14821 ○☆★◇◆ 1355 100 7500 6500 ERZE10A911 E10911 ○☆★◇◆ 1500 50 4500 3000 ERZE11A911 E11911 ○☆★◇◆ 1500 50 5000 4500 ERZE14A911 E14911 ○☆★◇◆ 1500 100 7500 6500 ERZE10A102 E10102 ○☆★◇◆ 1650 50 4500 3000 ERZE11A102 E11102 ○☆★◇◆ 1650 50 5000 4500 ERZE14A102 E14102 ○☆★◇◆ 1650 100 7500 6500 ERZE10A112 E10112 ○☆★◇◆ 1815 50 4500 3000 ERZE11A112 E11112 ○☆★◇◆ 1815 50 5000 4500 ERZE14A112 E14112 ○☆★◇◆ 1815 100 7500 6500 680 (612 to 748) 750 (675 to 825) 820 (738 to 902) 420 460 510 910 (819 to 1001) 550 1000 (900 to 1100) 625 1100 (990 to 1210) 680 560 615 670 745 825 895 ○: UL1449 (VZCA2/UL, VZCA8/C-UL), ☆ : VDE (IEC61051-1, -2, -2-2) ★ : VDE (IEC60950-1 Annex.Q, IEC62368-1 G8.2 ), ◇: CQC (GB/T10193, GB/T10194), ◆ : CQC (GB4943.1, GB8898) ※Approval number (File No.) of safety regulations are subject to revision without notice. Ask factory for a copy of the latest file No. Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20 D type / E5 series Ratings and characteristics ●Storage temperature range : ‒40 to 125 ℃ ●Operating temperature range : ‒40 to 85 ℃ Part No. ERZE05A201 Varistor voltage at 1 mA Maximum allowable voltage Clamping voltage (max.)**lp Maximum energy Rated power (10/1000 μs) (2 ms) Maximum peak current (8/20 μs) Capacitance (max.) at 1 kHz 1 time 2 times (V) ACrms (V) DC (V) (V) (W) (J) (J) (A) (A) (pF) 200(185 to 225) 130 170 340 0.25 13 9.5 1200 600 200 ERZE05A221 220(198 to 242) 140 180 360 0.25 14 10 1200 600 190 ERZE05A241 240(216 to 264) 150 200 395 0.25 15 11 1200 600 170 ERZE05A271 270(247 to 303) 175 225 455 0.25 18 13 1200 600 150 ERZE05A331 330(297 to 363) 210 270 545 0.25 21 15 1200 600 130 ERZE05A361 360(324 to 396) 230 300 595 0.25 23 17 1200 600 130 ERZE05A391 390(351 to 429) 250 320 650 0.25 26 19 1200 600 130 ERZE05A431 430(387 to 473) 275 350 710 0.25 29 21 1200 600 120 ERZE05A471 470(423 to 517) 300 385 775 0.25 32 23 1200 600 100 ✽Ip Measuring current of clamping voltage : 10 A Dimensions in mm (not to scale) Unit : mm T max. F±1.0 A max. L±1.0 ERZE05A201 7.0 4.8 5.0 10.0 2.1 ERZE05A221 7.0 4.9 5.0 10.0 2.3 D 7.0 5.0 5.0 10.0 2.4 7.0 5.2 5.0 10.0 2.5 ERZE05A331 7.0 5.5 5.0 10.0 2.9 ERZE05A361 7.0 5.8 5.0 10.0 3.1 ERZE05A391 7.0 5.9 5.0 10.0 3.2 F ERZE05A431 7.0 6.1 5.0 10.0 3.3 ø0.6 ERZE05A471 7.0 6.3 5.0 10.0 3.5 A ERZE05A241 ERZE05A271 T L Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. L D max. 20.0 min. Part No. F 14-Dec-20 D type / E5 series Typical characteristics Voltage vs. Current Impulse Derating (Relation between impulse width and impulse current multiple) ERZE05A201 to ERZE05A471 ERZE05A201 to ERZE05A471 10000 Max.Leakage Current Max.Clamping Voltage 2000 2 times:5 min. interval 471 431 391 361 331 271 241 221 201 471 431 1000 900 800 700 600 up to 10 times:2 min. interval up to 106 times : 10 sec. interval 1000 Impulse Current(A) 391 361 500 Voltage(V) 400 300 200 100 10 331 221 100 90 80 70 60 1 Test current waveform 10–6 to 10–3 A: Direct current 10–1 to 104 A: 8/20 μs 50 40 30 0.1 10-6 10-5 10-4 10-3 10-2 10-1 100 Current(A) 101 102 103 104 105 20 100 1000 10000 Impulse Width(μs) Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20 D type / E7 series Ratings and characteristics ●Storage temperature range : ‒40 to 125 ℃ ●Operating temperature range : ‒40 to 85 ℃ Part No. Varistor voltage at 1 mA Maximum allowable voltage Clamping voltage (max.)**lp Maximum peak current (8/20 μs) Maximum energy Rated power (10/1000 μs) (2 ms) Capacitance (max.) at 1 kHz 1 time 2 times (V) ACrms (V) DC (V) (V) (W) (J) (J) (A) (A) (pF) ERZE07A201 200(185 to 225) 130 170 340 0.3 26 19 2500 1250 360 ERZE07A221 220(198 to 242) 140 180 360 0.3 30 22 2500 1250 350 ERZE07A241 240(216 to 264) 150 200 395 0.3 33 24 2500 1250 340 ERZE07A271 270(247 to 303) 175 225 455 0.3 39 28 2500 1250 310 ERZE07A331 330(297 to 363) 210 270 545 0.3 44 32 2500 1250 280 ERZE07A361 360(324 to 396) 230 300 595 0.3 50 36 2500 1250 260 ERZE07A391 390(351 to 429) 250 320 650 0.3 53 38 2500 1250 240 ERZE07A431 430(387 to 473) 275 350 710 0.3 60 43 2500 1250 210 ERZE07A471 470(423 to 517) 300 385 775 0.3 65 47 2500 1250 170 ERZE07A511 510(459 to 561) 320 410 845 0.3 70 50 2500 1250 140 ERZE07A561 560(504 to 616) 350 450 930 0.3 75 55 2500 1250 140 ERZE07A621 620(558 to 682) 385 505 1025 0.3 80 60 2500 1250 135 ✽Ip Measuring current of clamping voltage : 25 A Dimensions in mm (not to scale) Unit : mm T max. F±1.0 A max. L±1.0 9.0 5.3 7.5 12.5 2.1 ERZE07A221 9.0 5.4 7.5 12.5 2.3 ERZE07A241 9.0 5.5 7.5 12.5 2.4 ERZE07A271 9.0 5.7 7.5 12.5 2.5 ERZE07A331 9.0 6.0 7.5 12.5 2.8 D 9.0 6.2 7.5 12.5 2.9 ERZE07A391 9.0 6.3 7.5 12.5 3.0 ERZE07A431 9.0 6.5 7.5 12.5 3.1 ERZE07A471 9.0 6.8 7.5 12.5 3.3 ERZE07A511 9.0 7.0 7.5 12.5 3.5 F ERZE07A561 9.0 7.4 7.5 13.5 3.8 ø0.8 ERZE07A621 10.0 7.8 7.5 13.5 4.0 A ERZE07A361 T L Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. L D max. 20.0 min. Part No. ERZE07A201 F 14-Dec-20 D type / E7 series Typical characteristics Voltage vs. Current Impulse Derating (Relation between impulse width and impulse current multiple) ERZE07A201 to ERZE07A621 ERZE07A201 to ERZE07A621 10000 2000 Max.Leakage Current Max.Clamping Voltage 561 511 471 431 391 361 1000 900 800 700 600 2 times:5 min. interval 621 561 511 471 431 391 361 331 up to 10 times:2 min. interval up to 106 times : 10 sec. interval 1000 271 241 221 201 Impulse Current(A) Voltage(V) 500 400 300 200 100 90 80 70 60 10 331 221 50 Test current waveform 10–6 to 10–3 A: Direct current 10–1 to 104 A: 8/20 μs 40 30 10-6 100 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 1 20 Current(A) Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 100 1000 10000 Impulse Width(μs) 14-Dec-20 D type / E8 series Ratings and characteristics ●Operating temperature range : ‒40 to 85 ℃ ●Storage temperature range : ‒40 to 125 ℃ Part No. ERZE08A201 Varistor voltage at 1 mA Maximum allowable voltage Clamping voltage (max.)**lp Maximum energy Rated power Maximum peak current (8/20 μs) 1 time 2 times Capacitance (max.) at 1 kHz (10/1000 μs) (2 ms) (W) (J) (J) (A) (A) (pF) (V) ACrms (V) DC (V) 200(185 to 225) 130 170 340 0.4 35 25 3500 2500 390 (V) ERZE08A221 220(198 to 242) 140 180 360 0.4 39 27.5 3500 2500 380 ERZE08A241 240(216 to 264) 150 200 395 0.4 42 30 3500 2500 360 ERZE08A271 270(247 to 303) 175 225 455 0.4 49 35 3500 2500 330 ERZE08A331 330(297 to 363) 210 270 545 0.4 58 42 3500 2500 300 ERZE08A361 360(324 to 396) 230 300 595 0.4 65 45 3500 2500 280 ERZE08A391 390(351 to 429) 250 320 650 0.4 70 50 3500 2500 260 ERZE08A431 430(387 to 473) 275 350 710 0.4 80 55 3500 2500 230 ERZE08A471 470(423 to 517) 300 385 775 0.4 85 60 3500 2500 180 ERZE08A511 510(459 to 561) 320 410 845 0.4 92 67 3500 2500 150 ERZE08A561 560(504 to 616) 350 450 930 0.4 92 67 3500 2500 150 ERZE08A621 620(558 to 682) 385 505 1025 0.4 92 67 3500 2500 140 ERZE08A681 680(612 to 748) 420 560 1120 0.4 92 67 3500 2500 130 ERZE08A751 750(675 to 825) 460 615 1240 0.4 100 70 3500 2500 130 ✽Ip Measuring current of clamping voltage : 25 A Dimensions in mm (not to scale) Unit : mm F±1.0 A max. L±1.0 5.1 7.5 13.5 1.9 ERZE08A221 10.5 5.2 7.5 13.5 2.0 ERZE08A241 10.5 5.3 7.5 13.5 2.1 ERZE08A271 10.5 5.5 7.5 13.5 2.3 ERZE08A331 10.5 5.9 7.5 13.5 2.6 ERZE08A361 10.5 6.1 7.5 13.5 2.8 ERZE08A391 10.5 6.3 7.5 13.5 2.9 ERZE08A431 10.5 6.5 7.5 13.5 3.1 ERZE08A471 10.5 7.3 7.5 13.5 3.6 ERZE08A511 10.5 7.8 7.5 13.5 4.0 ERZE08A561 10.5 8.1 7.5 13.5 4.3 ERZE08A621 11.5 8.7 7.5 14.5 4.7 ERZE08A681 11.5 9.0 7.5 14.5 5.0 ERZE08A751 11.5 9.7 7.5 14.5 5.6 D T L F ø0.8 Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. L T max. 10.5 A D max. 20.0 min. Part No. ERZE08A201 F 14-Dec-20 D type / E8 series Typical characteristics Voltage vs. Current Impulse Derating (Relation between impulse width and impulse current multiple) ERZE08A201 to ERZE08A511 ERZE08A201 to ERZE08A511 10000 2000 1000 900 800 700 600 Max.Leakage Current 2 times:5 min. interval Max.Clamping Voltage up to 10 times:2 min. interval up to 106 times : 10 sec. interval 511 471 431 391 361 331 271 241 221 201 471 431 391 361 1000 Impulse Current(A) Voltage(V) 500 400 300 200 100 90 80 70 60 10 331 221 50 Test current waveform 10–6 to 10–3 A: Direct current 10–1 to 104 A: 8/20 μs 40 1 30 10-6 100 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 20 105 Current(A) 1000 10000 Impulse Width(μs) ERZE08A561 to ERZE08A751 ERZE08A561 to ERZE08A751 10000 5000 4000 100 Max.Leakage Current Max.Clamping Voltage 2 times:5 min. interval up to 10 times:2 min. interval up to 106 times : 10 sec. interval 3000 1000 2000 751 681 Impulse Current(A) 621 Voltage(V) 561 1000 900 800 700 100 600 500 10 400 300 200 10-6 751 681 621 Test current waveform 10–6 to 10–3 A: Direct current 10–1 to 104 A: 8/20 μs 1 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 20 Current(A) Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 100 1000 10000 Impulse Width(μs) 14-Dec-20 D type / E10 series Ratings and characteristics ●Storage temperature range : ‒40 to 125 ℃ ●Operating temperature range : ‒40 to 85 ℃ Part No. Varistor voltage at 1 mA Maximum allowable voltage Clamping voltage (max.)**lp Maximum energy Rated power Maximum peak current (8/20 μs) 1 time 2 times Capacitance (max.) at 1 kHz (10/1000 μs) (2 ms) (W) (J) (J) (A) (A) (pF) (V) ACrms (V) DC (V) (V) ERZE10A201 200(185 to 225) 130 170 340 0.5 47 34 4500 3000 630 ERZE10A221 220(198 to 242) 140 180 360 0.5 50 36 4500 3000 600 ERZE10A241 240(216 to 264) 150 200 395 0.5 56 40 4500 3000 570 ERZE10A271 270(247 to 303) 175 225 455 0.5 64 46 4500 3000 530 ERZE10A331 330(297 to 363) 210 270 545 0.5 72 52 4500 3000 470 ERZE10A361 360(324 to 396) 230 300 595 0.5 84 60 4500 3000 430 ERZE10A391 390(351 to 429) 250 320 650 0.5 91 65 4500 3000 400 ERZE10A431 430(387 to 473) 275 350 710 0.5 99 71 4500 3000 350 ERZE10A471 470(423 to 517) 300 385 775 0.5 106 76 4500 3000 320 ERZE10A511 510(459 to 561) 320 410 845 0.5 117 84 4500 3000 300 ERZE10A561 560(504 to 616) 350 450 930 0.5 120 86 4500 3000 290 ERZE10A621 620(558 to 682) 385 505 1025 0.5 126 88 4500 3000 280 ERZE10A681 680(612 to 748) 420 560 1120 0.5 133 95 4500 3000 260 ERZE10A751 750(675 to 825) 460 615 1240 0.5 140 100 4500 3000 250 ERZE10A821 820(738 to 902) 510 670 1355 0.5 154 110 4500 3000 230 ERZE10A911 910(819 to 1001) 550 745 1500 0.5 168 112 4500 3000 220 ERZE10A102 1000(900 to 1100) 625 825 1650 0.5 182 130 4500 3000 200 ERZE10A112 1100(990 to 1210) 680 895 1815 0.5 196 140 4500 3000 180 ✽Ip Measuring current of clamping voltage : 50 A Dimensions in mm (not to scale) Unit : mm F±1.0 A max. L±1.0 ERZE10A201 11.5 5.3 ERZE10A221 11.5 5.4 7.5 15.0 2.1 7.5 15.0 2.3 ERZE10A241 11.5 ERZE10A271 11.5 5.5 7.5 15.0 2.4 5.7 7.5 15.0 2.5 ERZE10A331 11.5 6.0 7.5 15.0 2.8 ERZE10A361 11.5 6.2 7.5 15.0 2.9 ERZE10A391 11.5 6.3 7.5 15.0 3.0 ERZE10A431 11.5 6.5 7.5 15.0 3.1 ERZE10A471 11.5 6.8 7.5 15.0 3.3 ERZE10A511 11.5 7.0 7.5 15.0 3.5 ERZE10A561 11.5 7.4 7.5 15.0 3.8 ERZE10A621 12.5 7.8 7.5 16.0 4.0 ERZE10A681 12.5 8.1 7.5 16.0 4.2 ERZE10A751 12.5 8.6 7.5 16.0 4.6 ERZE10A821 12.5 8.9 7.5 16.0 5.0 ERZE10A911 12.5 9.5 7.5 16.0 5.7 ERZE10A102 12.5 10.0 7.5 16.0 6.2 ERZE10A112 12.5 10.6 7.5 16.0 6.8 D T L F ø0.8 Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. L T max. A D max. 20.0 min. Part No. F 14-Dec-20 D type / E10 series Typical characteristics Voltage vs. Current Impulse Derating (Relation between impulse width and impulse current multiple) ERZE10A201 to ERZE10A561 ERZE10A201 to ERZE10A561 10000 2000 Max.Leakage Current 2 times:5 min. interval Max.Clamping Voltage 561 511 471 431 391 361 331 511 471 431 391 1000 900 800 up to 10 times:2 min. interval up to 106 times : 10 sec. intervalA 1000 271 241 221 201 361 700 600 Impulse Current(A) Voltage (V) 500 400 300 200 100 90 80 70 10 331 221 60 Test current waveform 10–6 to 10–3 A: Direct current 10–1 to 104 A: 8/20 μs 50 40 30 10-6 100 1 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 20 105 Current(A) 10000 1000 Impulse Width(μs) ERZE10A621 to ERZE10A112 ERZE10A621 to ERZE10A112 5000 4000 100 10000 Max.Leakage Current Max.Clamping Voltage 2 times:5 min. interval up to 10 times:2 min. interval up to 106 times : 10 sec. interval 112 102 911 3000 821 751 681 1000 621 Impulse Current(A) 2000 Voltage(V) 102 1000 911 821 900 800 700 600 100 500 10 400 300 Test current waveform 10–6 to 10–3 A: Direct current 10–1 to 104 A: 8/20 μs 751 681 621 200 10-6 1 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 20 Current(A) Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 100 1000 10000 Impulse Width(μs) 14-Dec-20 D type / E11 series Ratings and characteristics ●Storage temperature range : ‒40 to 125 ℃ ●Operating temperature range : ‒40 to 85 ℃ Part No. Varistor voltage at 1 mA Maximum allowable voltage Clamping voltage (max.)**lp Rated power Maximum peak current (8/20 μs) Maximum energy (10/1000 μs) (2 ms) Capacitance (max.) at 1 kHz 1 time 2 times (V) ACrms (V) DC (V) (V) (W) (J) (J) (A) (A) (pF) ERZE11A201 200(185 to 225) 130 170 340 0.6 70 50 6000 5000 690 ERZE11A221 220(198 to 242) 140 180 360 0.6 78 55 6000 5000 660 ERZE11A241 240(216 to 264) 150 200 395 0.6 84 60 6000 5000 620 ERZE11A271 270(247 to 303) 175 225 455 0.6 99 70 6000 5000 580 ERZE11A331 330(297 to 363) 210 270 545 0.6 115 80 6000 4500 520 ERZE11A361 360(324 to 396) 230 300 595 0.6 130 90 6000 4500 480 ERZE11A391 390(351 to 429) 250 320 650 0.6 140 100 6000 4500 450 ERZE11A431 430(387 to 473) 275 350 710 0.6 155 110 6000 4500 400 ERZE11A471 470(423 to 517) 300 385 775 0.6 175 125 6000 4500 360 ERZE11A511 510(459 to 561) 320 410 845 0.6 190 136 6000 4500 310 ERZE11A561 560(504 to 616) 350 450 930 0.6 190 136 6000 4500 310 ERZE11A621 620(558 to 682) 385 505 1025 0.6 190 136 5000 4500 300 ERZE11A681 680(612 to 748) 420 560 1120 0.6 190 136 5000 4500 290 ERZE11A751 750(675 to 825) 460 615 1240 0.6 210 150 5000 4500 280 ERZE11A821 820(738 to 902) 510 670 1355 0.6 235 165 5000 4500 260 ERZE11A911 910(819 to 1001) 550 745 1500 0.6 255 180 5000 4500 240 ERZE11A102 1000(900 to 1100) 625 825 1650 0.6 280 200 5000 4500 220 ERZE11A112 1100(990 to 1210) 680 895 1815 0.6 310 220 5000 4500 200 ✽Ip Measuring current of clamping voltage : 50 A Dimensions in mm (not to scale) Unit : mm F±1.0 A max. L±1.0 ERZE11A201 13.0 5.2 7.5 17.0 1.9 ERZE11A221 13.0 5.3 7.5 17.0 2.0 ERZE11A241 13.0 5.4 7.5 17.0 2.1 ERZE11A271 13.0 5.6 7.5 17.0 2.3 ERZE11A331 13.0 5.9 7.5 17.0 2.6 ERZE11A361 13.0 6.1 7.5 17.0 2.8 ERZE11A391 13.0 6.2 7.5 17.0 2.9 ERZE11A431 13.0 6.4 7.5 17.0 3.1 ERZE11A471 13.0 6.6 7.5 17.0 3.3 ERZE11A511 13.0 6.8 7.5 17.0 3.5 ERZE11A561 13.0 7.2 7.5 17.0 3.8 ERZE11A621 14.0 7.5 7.5 18.0 4.2 ERZE11A681 14.0 7.8 7.5 18.0 4.5 ERZE11A751 14.0 8.2 7.5 18.0 4.9 ERZE11A821 14.0 8.5 7.5 18.0 5.2 ERZE11A911 14.0 9.0 7.5 18.0 5.7 ERZE11A102 14.0 9.5 7.5 18.0 6.2 ERZE11A112 14.0 10.1 7.5 18.0 6.8 D T L F ø0.8 Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. L T max. A D max. 20.0 min. Part No. F 14-Dec-20 D type / E11 series Typical characteristics Voltage vs. Current Impulse Derating (Relation between impulse width and impulse current multiple) ERZE11A201 to ERZE11A511 ERZE11A201 to ERZE11A511 10000 2000 Max.Leakage Current 2 times:5 min. interval Max.Clamping Voltage up to 10 times:2 min. interval up to 106 times : 10 sec. interval 511 471 431 391 361 331 271 241 221 201 471 431 391 361 1000 Impulse Current(A) 1000 900 800 700 600 Voltage(V) 500 400 300 200 100 90 80 70 60 10 331 221 Test current waveform 10–6 to 10–3 A: Direct current 10–1 to 104 A: 8/20 μs 50 40 30 10-6 100 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 120 105 Current(A) 100 1000 10000 Impulse Width(μs) ERZE11A561 to ERZE11A112 ERZE11A561 to ERZE11A112 5000 10000 Max.Leakage Current Max.Clamping Voltage 2 times:5 min. interval up to 10 times:2 min. interval up to 106 times : 10 sec. interval 4000 3000 112 102 911 821 2000 1000 751 681 911 Impulse Current(A) 621 561 102 Voltage(V) 821 1000 900 800 700 600 100 500 10 400 300 Test current waveform 10–6 to 10–3 A: Direct current 10–1 to 104 A: 8/20 μs 751 681 200 10-6 621 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 1 20 Current(A) Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 100 1000 10000 Impulse Width(μs) 14-Dec-20 D type / E14 series Ratings and characteristics ●Storage temperature range : ‒40 to 125 ℃ ●Operating temperature range : ‒40 to 85 ℃ Part No. Varistor voltage at 1 mA Maximum allowable voltage Clamping voltage (max.)**lp Maximum peak current (8/20 μs) Maximum energy Rated power (10/1000 μs) (2 ms) 1 time 2 times Capacitance (max.) at 1 kHz (V) ACrms (V) DC (V) (V) (W) (J) (J) (A) (A) (pF) ERZE14A201 200(185 to 225) 130 170 340 1.0 140 100 10000 7000 1300 ERZE14A221 220(198 to 242) 140 180 360 1.0 155 110 10000 7000 1200 ERZE14A241 240(216 to 264) 150 200 395 1.0 168 120 10000 7000 1100 ERZE14A271 270(247 to 303) 175 225 455 1.0 190 135 10000 7000 1000 ERZE14A331 330(297 to 363) 210 270 545 1.0 228 160 10000 6500 900 ERZE14A361 360(324 to 396) 230 300 595 1.0 255 180 10000 6500 900 ERZE14A391 390(351 to 429) 250 320 650 1.0 275 195 10000 6500 800 ERZE14A431 430(387 to 473) 275 350 710 1.0 303 215 10000 6500 800 ERZE14A471 470(423 to 517) 300 385 775 1.0 350 250 10000 6500 750 ERZE14A511 510(459 to 561) 320 410 845 1.0 382 273 10000 6500 700 ERZE14A561 560(504 to 616) 350 450 930 1.0 382 273 10000 6500 700 ERZE14A621 620(558 to 682) 385 505 1025 1.0 382 273 7500 6500 650 ERZE14A681 680(612 to 748) 420 560 1120 1.0 382 273 7500 6500 600 ERZE14A751 750(675 to 825) 460 615 1240 1.0 420 300 7500 6500 530 ERZE14A821 820(738 to 902) 510 670 1355 1.0 460 325 7500 6500 500 ERZE14A911 910(819 to 1001) 550 745 1500 1.0 510 360 7500 6500 400 ERZE14A102 1000(900 to 1100) 625 825 1650 1.0 565 400 7500 6500 400 ERZE14A112 1100(990 to 1210) 680 895 1815 1.0 620 440 7500 6500 350 ✽Ip Measuring current of clamping voltage : 100 A Dimensions in mm (not to scale) Unit : mm F±1.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 A max. 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.5 20.5 20.5 20.5 20.5 20.5 20.5 L±1.0 2.1 2.2 2.3 2.5 2.8 3.0 3.1 3.3 3.5 3.7 4.0 4.4 4.7 5.1 5.4 5.9 6.4 7.2 D T L F ø1.0 Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. L T max. 5.2 5.3 5.4 5.6 5.9 6.1 6.2 6.4 6.6 6.8 7.2 7.5 7.8 8.2 8.5 9.0 9.5 10.1 A ERZE14A201 ERZE14A221 ERZE14A241 ERZE14A271 ERZE14A331 ERZE14A361 ERZE14A391 ERZE14A431 ERZE14A471 ERZE14A511 ERZE14A561 ERZE14A621 ERZE14A681 ERZE14A751 ERZE14A821 ERZE14A911 ERZE14A102 ERZE14A112 D max. 16.5 16.5 16.5 16.5 16.5 16.5 16.5 16.5 16.5 16.5 16.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 20.0 min. Part No. F 14-Dec-20 D type / E14 series Typical characteristics Voltage vs. Current Impulse Derating (Relation between impulse width and impulse current multiple) ERZE14A201 to ERZE14A511 ERZE14A201 to ERZE14A511 10000 Max.Leakage Current 2000 2 times:5 min. interval Max.Clamping Voltage up to 10 times:2 min. interval up to 106 times : 10 sec. interval 511 471 431 391 361 331 471 431 391 361 1000 900 800 700 600 1000 271 Impulse Current (A) 241 221 201 Voltage(V) 500 400 300 200 100 90 80 70 60 100 10 241 331 221 Test current waveform 10–6 to 10–3 A: Direct current 10–1 to 104 A: 8/20 μs 50 40 1 30 10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 20 105 Current(A) 1000 10000 Impulse Width(μs) ERZE14A561 to ERZE14A112 ERZE14A561 to ERZE14A112 10000 5000 Max.Leakage Current 4000 2 times:5 min. interval Max.Clamping Voltage up to 10 times:2 min. interval up to 106 times : 10 sec. interval 3000 112 102 911 1000 821 2000 751 681 Impulse Current(A) 621 561 Voltage(V) 100 102 911 821 1000 900 800 700 100 600 500 10 400 300 Test current waveform 10–6 to 10–3 A: Direct current 10–1 to 104 A: 8/20 μs 751 681 621 200 10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 1 20 Current(A) Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 100 1000 10000 Impulse Width(μs) 14-Dec-20 D type / E series (Leads cut type) Straight leads cut type (Bulk type) ※ Ratings and characteristics is refer to bulk standard type. Dimensions in mm (not to scale) D H T** W B ød L* notes ✽ Dimension “L”: Conforms to each individtual specification.    ✽✽ Dimension “T”: Conforms to each individual specification. Unit : mm Series E5 Varister Voltage Symbol D H W E7 E10 E11 201 to 471 201 to 511 561 621 201 to 561 621 to 751 201 to 561 621 to 112 201 to 561 621 to 112 7.0 max. 9.0 max. 9.0 max. 10.0 max. 10.5 max. 11.5 max. 11.5 max. 12.5 max. 13.0 max. 14.0 max. 10.0 max. 12.5 max. 13.5 max. 13.5 max. 13.5 max. 14.5 max. 15.0 max. 16.0 max. 17.0 max. 18.0 max. 5.0±1.0 ød E8 0.60 +0.06 -0.05 B 4.0±1.0 Standard products part No. ERZE05A□□□CS 7.5±1.0 0.80 +0.08 -0.05 4.0±1.0 7.5±1.0 0.80 +0.08 -0.05 4.0±1.0 7.5±1.0 0.80 +0.08 -0.05 4.0±1.0 ERZE07A□□□CS 7.5±1.0 0.80 7.5±1.0 +0.08 -0.05 0.80 4.0±1.0 +0.08 -0.05 4.0±1.0 ERZE08A□□□CS 7.5±1.0 0.80 +0.08 -0.05 4.0±1.0 7.5±1.0 0.80 +0.08 -0.05 4.0±1.0 7.5±1.0 0.80 +0.08 -0.05 4.0±1.0 ERZE10A□□□CS 7.5±1.0 0.80 +0.08 -0.05 4.0±1.0 ERZE11A□□□CS Crimped leads cut type (Bulk Type) ※ Ratings and characteristics is refer to bulk standard type. Dimensions in mm (not to scale) D A T** *** C ød B C W L* notes ✽ Dimension “L”: Conforms to each individtual specification.    ✽✽ Dimension “T”: Conforms to each individual specification.   ✽✽✽ Resin extenyions : No resin below the center of the hook. Unit : mm Series Varister Voltage E5 E7 E10 E8 E11 201 to 471 201 to 511 561 621 201 to 561 621 to 751 201 to 561 621 to 681 751 to 112 201 to 561 621 to 112 D 7.0 max. 9.0 max. 9.0 max. 10.0 max. 10.5 max. 11.5 max. 11.5 max. 12.5 max. 12.5 max. 13.0 max. 14.0 max. Symbol A 13.0 max. 15.5 max. 16.5 max. 16.5 max. 17.0 max. 18.0 max. 18.0 max. 19.5 max.. 20.5 max. 20.5 max. 21.5 max. C 1.2±1.4 1.4±1.4 1.4±1.4 1.4±1.4 1.4±1.4 1.4±1.4 1.4±1.4 1.4±1.4 1.4±1.4 1.4±1.4 1.4±1.4 W 5.0±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0 ød 0.60 +0.06 0.80 -0.05 B 4.0±1.0 Standard products part No. ERZE05B□□□CS +0.08 0.80 -0.05 4.0±1.0 +0.08 0.80 -0.05 4.0±1.0 +0.08 0.80 -0.05 4.0±1.0 ERZE07B□□□CS +0.08 0.80 -0.05 4.0±1.0 +0.08 0.80 -0.05 4.0±1.0 ERZE08B□□□CS +0.08 0.80 -0.05 4.0±1.0 +0.08 0.80 -0.05 4.0±1.0 +0.08 0.80 -0.05 4.0±1.0 ERZE10B□□□CS Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. +0.08 0.80 -0.05 4.0±1.0 +0.08 -0.05 4.0±1.0 ERZE11B□□□CS 14-Dec-20 D type / E series (Taping specifications) Taping specifications for automated assembly (Straight leads and taping) ※ Ratings and characteristics is refer to bulk standard type. Dimensions in mm (not to scale) P2 P øD △h F1 W1 Position of H0 dimension W L W0 W2 P1 H0 H A T* F P0 Position of F1 dimension øD0 t ød ✽ Dimension “T”: Conforms to each individual specification. Unit : mm Series Varister Voltage Symbol E5 E7 201 to 471 201 to 271 331 to 551 E8 561 621 E10 E11 201 to 221 241 to 561 621 to 751 201 to 221 241 to 561 621 to 112 201 to 221 241 to 561 621 to 112 P 12.7±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 P0 12.7±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 P1 3.85±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 P2 ød 6.36±1.30 0.60 +0.06 -0.05 7.5±1.3 0.80 +0.08 -0.05 7.5±1.3 0.80 +0.08 -0.05 7.5±1.3 0.80 +0.08 -0.05 7.5±1.3 0.80 +0.08 -0.05 7.5±1.3 0.80 +0.08 -0.05 7.5±1.3 0.80 +0.08 -0.05 7.5±1.3 0.80 +0.08 -0.05 7.5±1.3 0.80 +0.08 -0.05 7.5±1.3 0.80 +0.08 -0.05 7.5±1.3 0.80 +0.08 -0.05 7.5±1.3 0.80 +0.08 -0.05 7.5±1.3 0.80 +0.08 -0.05 F 5.0±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 △h 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 W 18.0 +1.0 -0.5 18.0 +1.0 -0.5 18.0 +1.0 -0.5 18.0 +1.0 -0.5 18.0 +1.0 -0.5 18.0 +1.0 -0.5 18.0 +1.0 -0.5 18.0 +1.0 -0.5 18.0 +1.0 -0.5 18.0 +1.0 -0.5 18.0 +1.0 -0.5 18.0 +1.0 -0.5 18.0 +1.0 -0.5 15.0±1.0 7.5±1.3 0.80 +0.08 -0.05 7.5±0.5 0±2 18.0 +1.0 -0.5 W0 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. W1 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. W2 H H0 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 17.0±0.5 18.0 +2.0 0 F1 ―― ―― ø D0 ø4.0±0.2 ø4.0±0.2 ―― 16.0 +0.75 -0.50 ø4.0±0.2 ―― 16.0 +0.75 -0.50 ø4.0±0.2 ―― 16.0 +0.75 -0.50 ø4.0±0.2 18.0 +2.0 0 ―― ―― 16.0 ø4.0±0.2 +0.75 -0.50 ø4.0±0.2 ―― 16.0 +0.75 -0.50 ø4.0±0.2 18.0 +2.0 0 ―― 16.0 ―― ø4.0±0.2 +0.75 -0.50 ø4.0±0.2 ―― 16.0 +0.75 -0.50 ø4.0±0.2 18.0 +2.0 0 ―― 16.0 ―― ø4.0±0.2 +0.75 -0.50 ø4.0±0.2 ―― 16.0 +0.75 -0.50 ø4.0±0.2 t 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 L 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. øD 7.0 max. 9.0 max. 9.0 max. 9.0 max. 10.0 max. 10.5 max. 10.5 max. 11.5 max. 11.5 max. 11.5 max. 12.5 max. 13.0 max. 13.0 max. 14.0 max. A 10.0 max. 12.5 max. 12.5 max. 13.5 max. 13.5 max. 13.5 max. 13.5 max. 14.5 max. 15.0 max. 15.0 max. 16.0 max. 17.0 max. 17.0 max. 18.0 max. Standard products part ERZE05E □□ ERZE07E□□□ ERZE08E□□□ ERZE10E□□□ Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. ERZE11E□□□ 14-Dec-20 D type / E series (Taping specifications) Taping specifications for automated assembly (Crimped leads and taping) ※ Ratings and characteristics is refer to bulk standard type. Dimensions in mm (not to scale) øD P △h T* W W1 L W0 H0 W2 P1 H A P2 F P0 øD0 t ød ✽ Dimension “T”: Conforms to each individual specification. Unit : mm Series Varister Voltage E5 E7 E8 E10 E11 561 621 P 12.7±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 P0 12.7±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 P1 3.85±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 P2 6.36±1.30 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 Symbol ød 201 to 471 201 to 551 0.60 +0.06 -0.05 0.80 +0.08 -0.05 0.80 +0.08 -0.05 0.80 +0.08 -0.05 201 to 221 241 to 561 621 to 751 201 to 561 621 to 681 751 to 112 201 to 221 241 to 561 621 to 112 0.80 +0.08 -0.05 0.80 +0.08 -0.05 0.80 +0.08 -0.05 0.80 +0.08 -0.05 0.80 +0.08 -0.05 0.80 +0.08 -0.05 0.80 +0.08 -0.05 0.80 +0.08 -0.05 F 5.0±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 △h 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 W 18.0 +1.0 -0.5 18.0 +1.0 -0.5 18.0 +1.0 -0.5 18.0 +1.0 -0.5 18.0 +1.0 -0.5 18.0 +1.0 -0.5 18.0 +1.0 -0.5 18.0 +1.0 -0.5 18.0 +1.0 -0.5 18.0 +1.0 -0.5 18.0 +1.0 -0.5 18.0 +1.0 -0.5 15.0±1.0 0.80 +0.08 -0.05 7.5±0.5 0±2 18.0 +1.0 -0.5 W0 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. W1 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 W2 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. H Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 5.0 min. H0 17.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5 ø D0 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 t 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 L 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. øD 7.0 max. 9.0 max. 9.0 max. 10.0 max. 10.5 max. 10.5 max. 11.5 max. 11.5 max. 12.5 max. 12.5 max. 13.0 max. 13.0 max. 14.0 max. A 13.0 max. 15.5 max. 16.5 max. 16.5 max. 17.0 max. 17.0 max. 18.0 max. 18.0 max. 19.5 max. 20.5 max. 20.5 max. 20.5 max. 21.5 max. Standard products part ERZE05F□□□ ERZE07F□□□ ERZE08F□□□ ERZE10F□□□ Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. ERZE11F□□□ 14-Dec-20 D type / E series Application note for safety standards ● Approvals products lists in "Reference Guide to Standard Products." ● UL and VDE : Registered in "Type name", it isn’t registered in "Panasonic Part No." ● CQC : Registered in "Panasonic Part No." ● "Rated Voltages" are specified for UL recognized components in list shown below.  The AC rated voltage and maximum allowable voltage Type name Maximum allowable voltage Rated voltage (Vrms) ACrms (V) DC (V) UL1449 E✽201 130 170 118 E✽221 140 180 127 E✽241 150 200 136 E✽271 175 225 159 E✽331 210 270 189 E✽361 230 300 209 E✽391 250 320 227 E✽431 275 350 250 E✽471 300 385 272 E✽511 320 410 291 E✽561 350 450 320 E✽621 385 505 350 E✽681 420 560 381 E✽751 460 615 418 E✽821 510 670 463 E✽911 550 745 500 E✽102 625 825 568 E✽112 680 895 600 ✽:5 Series is blank, 7 series is 7, 8 series is 8, 10 series is 10, 11 series is 11, 14 series is 14 Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20 D type / E series Explanation of the contents Mark Explanation of the content Abbreviation of part No. (Type Name) □□□ Nominal varistor volage 〇 Factory identication mark None : Japan Q : Indonesia ◆*1 Year code 2019 : 9, 2020 : K, 2021 : A 2022 : B, 2023 : C, 2024 : D ◇ Monthly code Jan : 1 to Sep : 9, Oct. : 0, Nov. : N,Dec. : D     E✽□□□ Marking UL Recognized components mark ✽: 5 series is blank, 7 series is 7, 8 series is 8, 10 series is 10, 11 series is 11, 14 series is 14 *1: If the 10's digit of a Christian year is an even year, as an end abbreviation, an alphabetic character is used.    1 : A, 2 : B, 3 : C, 4 : D, 5 : E, 6 : F, 7 : G, 8 : H, 9 : J, 0 : K If the 10's digit of a Christian year is an odd year, as an end abbreviation, a number is used. Marking contents              Series               (Example) Varister voltage 201 or more 5 7 8 10 11 14 (ERZE05A□□□) (ERZE07A□□□) (ERZE08A□□□) (ERZE10A□□□) (ERZE11A□□□) (ERZE14A□□□) ZNR E□□□   ○◆◇ ZNR E7□□□   ○◆◇ ZNR E8□□□   ○◆◇ ZNR E10□□□   ○◆◇ ZNR E11□□□   ○◆◇ ZNR E14□□□   ○◆◇ Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20 D type / E series Performance characteristics Characteristics Standard test condition Test methods / description Specifications Electrical measurements (initial/after tests) shall be conducted at temperature of 5 to 35℃, relative humidity of maximum 85 %. Varistor voltage The voltage betwen two terminals with the specified measuring current 1mA DC applied is called V1 or V1mA. The measurement shall be made as fast as possible to avoid heat affection. Maximum allowable voltage The maximum sinusoidal RMS voltage or maximum DC voltage that can be applied continuously. ― The maximum voltage between two terminals with the specified standard impulse current (8/20 μs) illustrated below applied. Current (%) 100 90 Clamping voltage 50 10 0 Rated power Maximum energy 8 μs To meet the specified value. Time 20 μs The power that can be applied in the specified ambient temperature. The maximum energy within the varistor voltage change of ±10 % when a single impulse current of 2 ms or 10/1000 μs is applied. Electrical The maximum current within the varistor voltage change of ±10 % when a standard Maximum 2times impulse current of 8/20 μs is applied two times with an interval of 5 minutes. peak current (Withstanding surge The maximum current within the varistor voltage change of ±10 % with a single current) 1time standard impulse current of 8/20 μs is applied. Temperature coefficient of varistor voltage Capacitance V1mA at 85℃–V1mA at 25℃   × V1mA at 25℃ 1 100(%/℃) 60 0 to ‒0.05 %/ ℃ max. To meet the specified value. Capacitance shall be measured at 1 kHz ±10 %, 1 Vrms max. (1 MHz ±10 % below 100 pF), 0 V bias and 20±2℃. Withstanding voltage AC 1500 Vrms shall be applied between both terminals of the specimen connected (Body insulation) together and metal foil closely wrapped round its body for 1 minute. No breakdown The change of VC shall be measured after the impulse current listed below is applied 10000 or 100000 times continuously with the interval of 10 seconds at room temperature. Item Times Impulse life Part No. Current Impulse Life(Ⅰ) 4 ×10 Times Impulse Life(Ⅱ) ×105 Times Impulse Current ERZE05A201 to ERZE05A471 50 A (8/20 μs) 35 A (8/20 μs) ERZE07A201 to ERZE07A471 100 A (8/20 μs) 70 A (8/20 μs) ERZE08A201 to ERZE08A751 150 A (8/20 μs) 85 A (8/20 μs) ERZE10A201 to ERZE10A112 170 A (8/20 μs) 90 A (8/20 μs) ERZE11A201 to ERZE11A112 200 A (8/20 μs) 110 A (8/20 μs) ERZE14A201 to ERZE14A112 250 A (8/20 μs) 120 A (8/20 μs) Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. ΔV1mA/V1mA ≦ 0 to +20% 14-Dec-20 D type / E series Performance characteristics Characteristics Robustness of terminations (Tensile) Mechanical Robustness of terminations (Bending) Test methods / description Specifications After gradually applying the force specified below and keeping the unit fixed for 10 seconds, the terminal shall be visually examined for any damage. Terminal diameter ø0.6 mm, ø0.8 mm ø1.0 mm Force 9.8 N 19.6 N The unit shall be secured with its terminal kept vertical and the force specified below shall be applied in the axial direction. The terminal shall gradually be bent by 90 ° in one direction, then 90 ° in the opposite direction, and again back to the original position. The damage of the terminal shall be visually examined. Terminal diameter Force ø0.6 mm, ø0.8 mm 4.9 N ø1.0 mm 9.8 N Vibration After repeadly applying a single harmonic vibration (amplitude: 0.75 mm, double amplitude: 1.5 mm) with 1 minute vibration frequency cycles (10 Hz to 55 Hz to 10 Hz) to each of three perpendicular directions for 2 hours. Thereafter, the unit shall be visually examined. Solderability After dipping the terminals to a depth of approximately 3 mm from the body in a soldering bath of 235±5℃ for 2±0.5 seconds, the terminal shall be visually examined. Resistance to soldering heat High temperature storage/Dry heat Humidity No remarkable mechanical damage Approximately 95 % of the termainals shall be covered with new solder uniformly. After each lead shall be dipped into a solder bath having a temperature of 260±5℃ to a point 2.0 to 2.5 mm from the body of the unit, using shielding board (t=1.5 mm), be held there for 10±1 s and then be stored at room temperature and normal humidity for 1 to 2 hours. The change of VCmA and mechanical damages shall be examined. ΔV1mA/V1mA ≦ ±5 % The specimen shall be subjected to 125±2℃ for 1000 hours in a thermostatic bath without load and then stored at room temperature and normal humidity for 1 to 2 hours. Thereafter, the change of VCmA shall be measured. ΔV1mA/V1mA ≦ ±5 % The specimen shall be subjected to 40±2℃, 90 to 95 % RH for 1000 hours without load and then stored at room temperature and normal humidity for 1 to 2 hours. Thereafter, the change of VCmA shall be measured. ΔV1mA/V1mA ≦ ±5 % Environmental The temperature cycle shown below shall be repeated five cycles and then stored at room temperature and normal humidity for 1 to 2 hours. The change of VCmA and mechanical damage shall be examined. Temperature cycle High temperature load/Dry heat load Step Temperature (℃) Period (minutes) 1 –40±3 30±3 2 Room temperature 15±3 3 125±2 30±3 4 Room temperature 15±3 ΔV1mA/V1mA ≦ ±5 % No remarkable mechanical damage After being continuously applied the Maximum Allowable Voltage at 85±2℃ for 1000 hours, the specimen shall be stored at room temperature and normal humidity for 1 to 2 hours. Thereafter, the change of VCmA shall be measured. Damp heat load/ Humidity load The specimen shall be subjected to 40±2℃, 90 to 95 % RH and the Maximum Allowable Voltage for 1000 hours and then stored at room temperature and normal humidity for 1 to 2 hours. Thereafter, the change of VCmA shall be measured. Low temperature storage/Cold The specimen shall be subjected to –40±2℃ without load for 1000 hours and then stored at room temperature and normal humidity for 1 to 2 hours. Thereafter, the change of VCmA shall be measured. Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. ΔV1mA/V1mA ≦ ±10 % ΔV1mA/V1mA ≦ ±5 % 14-Dec-20 D type / E series Minimum quantity / Packing unit Product Series / Type Straight leads <Bulk> Leads cut type <Bulk> Varistors (ZNR Surge Absorber) D type E series Straight leads and taped Crimped lead and taped Part number ERZE05A201 to 471 ERZE07A201 to 391 ERZE07A431 to 621 ERZE08A201 to 331 ERZE08A361 to 511 ERZE08A561 to 751 ERZE10A201 to 241 ERZE10A271 to 431 ERZE10A471 to 112 ERZE11A201 to 361 ERZE11A391 to 561 ERZE11A621 to 112 ERZE14A201 to 221 ERZE14A241 to 431 ERZE14A471 to 112 ERZE05A(B)201CS to 471CS ERZE07A(B)201CS to 391CS ERZE07A(B)431CS to 621CS ERZE08A(B)201CS to 331CS ERZE08A(B)361CS to 511CS ERZE08A(B)561CS to 751CS ERZE10A(B)201CS to 241CS ERZE10A(B)271CS to 431CS ERZE10A(B)471CS to 112CS ERZE11A(B)201CS to 361CS ERZE11A(B)391CS to 561CS ERZE11A(B)621CS to 112CS ERZE05E201 to 471 ERZE07E201 to 271 ERZE07E331 to 471 ERZE07E511 to 621 ERZE08E201 to 271 ERZE08E331 to 431 ERZE08E471 to 511 ERZE08E561 to 751 ERZE10E201 to 241 ERZE10E271 to 471 ERZE10E511 to 561 ERZE10E621 to 112 ERZE11E201 to 271 ERZE11E331 to 511 ERZE11E561 to 112 ERZE05F201 to 471 ERZE07F201 to 271 ERZE07F331 to 471 ERZE07F511 to 621 ERZE08F201 to 271 ERZE08F331 to 431 ERZE08F471 to 511 ERZE08F561 to 751 ERZE10F201 to 241 ERZE10F271 to 471 ERZE10F511 to 561 ERZE10F621 to 112 ERZE11F201 to 271 ERZE11F331 to 511 ERZE11F561 to 112 Minimum Packing quantity quantity in carton / Packing unit 100 50 50 50 50 50 50 50 50 50 50 50 50 50 50 100 100 50 100 50 50 100 50 50 50 50 50 1000 1000 1000 500 1000 1000 1000 500 1000 1000 1000 500 1000 1000 500 1000 1000 1000 500 1000 1000 1000 500 1000 1000 1000 500 1000 1000 500 10000 3000 3000 3000 3000 2000 3000 3000 2000 3000 2000 1000 2000 2000 1000 10000 4000 4000 4000 4000 3000 4000 4000 3000 3000 2000 2000 10000 10000 10000 5000 5000 5000 5000 500 5000 5000 5000 500 5000 5000 500 10000 10000 10000 5000 5000 5000 5000 500 5000 5000 5000 500 5000 5000 500 Carton (about) L×W×H (mm) 210×340×180 210×340×110 210×340×110 210×340×110 210×340×110 210×340×110 210×340×110 210×340×110 210×340×110 210×340×110 210×340×110 210×340×110 210×340×110 210×340×110 210×340×110 210×340×180 210×340×110 210×340×110 210×340×110 210×340×110 210×340×110 210×340×110 210×340×110 210×340×110 210×340×110 210×340×110 210×340×110 400×360×260 400×360×260 470×360×260 400×360×260 360×310×320 360×310×320 360×310×320 360×270×320 360×310×320 360×310×320 360×310×320 360×270×320 360×310×320 360×310×320 360×270×320 400×360×260 400×360×260 470×360×260 400×360×260 360×310×320 360×310×320 360×310×320 360×270×320 360×310×320 360×310×320 360×310×320 360×270×320 360×310×320 360×310×320 360×270×320 Part No., quantity and country of origin are designated on outer packages in English. ※Please contact local sales office about packing specifications. Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20 Guidelines and precautions regarding the technical information and use of our products described in this online catalog. ■ If you want to use our products described in this online catalog for applications requiring special qualities or reliability, or for applications where the failure or malfunction of the products may directly jeopardize human life or potentially cause personal injury (e.g. aircraft and aerospace equipment, traffic and transportation equipment, combustion equipment, medical equipment, accident prevention, anti-crime equipment, and/or safety equipment), it is necessary to verify whether the specifications of our products fit to such applications. Please ensure that you will ask and check with our inquiry desk as to whether the specifications of our products fit to such applications use before you use our products. ■ The quality and performance of our products as described in this online catalog only apply to our products when used in isolation. Therefore, please ensure you evaluate and verify our products under the specific circumstances in which our products are assembled in your own products and in which our products will actually be used. ■ Please ensure the safety by means of protection circuit, redundant circuit etc. in your system design in order to prevent the occurrence of life crisis and other serious damages due to the failure of our products. ■ The products and product specifications described in this online catalog are subject to change for improvement without prior notice. Therefore, please be sure to request and confirm the latest product specifications which explain the specifications of our products in detail, before you finalize the design of your applications, purchase, or use our products. ■ The technical information in this online catalog provides examples of our products' typical operations and application circuits. We do not guarantee the non-infringement of third party's intellectual property rights and we do not grant any license, right, or interest in our intellectual property. ■ If any of our products, product specifications and/or technical information in this online catalog is to be exported or provided to non-residents, the laws and regulations of the exporting country, especially with regard to security and export control, shall be observed. ■ The switchover date for compliance with the RoHS Directive/REACH Regulations varies depending on the part number or series of our products. ■ When you use the inventory of our products for which it is unclear whether those products are compliant with the RoHS Directive/REACH Regulation, please select "Sales Inquiry" in the website inquiry form and contact us. Please note that we do not owe any liability and responsibility if our products are used beyond the description of this catalog or without complying with precautions in this catalog. 25-Nov-22 c Varistors (ZNR Surge Absorber)   Handling Precautions (D type / E, E-S1 series) 1. Safety precautions In case that a Varistors (ZNR Surge Absorber) (hereafter referred to as the ZNR, or product name) is used, if an abnormality takes place because of peripheral conditions of the ZNR(material, environments, power source conditions, circuit conditions, etc. in equipment design), fire, electric shock, burn, or product failure may be occur. The precautions for this product are described below, understand the content thoroughly before usage. For more questions, contact us. If there's any uncertainty/doubt/products safety items, please contact us. When a dogma shall be occurred about safety for this products, be sure to inform us rapidly, operate your technical examination. 2. Precautions to be strictly observed 2.1 Confirmation of performance ratings Use the ZNR within its rated range of performance such as the Max. allowable voltage, withstanding surge current, withstanding energy, impulse life(surge life), average pulse power, and operating temperature range. If used outside the range, the ZNR can be degrade and have element fracture, which may result in smoking and ignition. 2.2 To avoid accidents due to unexpected phenomena, take the following measures ・ In the event of fracture of the ZNR, its pieces may scatter ; hence, put the case or cover of the set product in place. ・ Do not install the ZNR near combustible substances(polyvinyl chloride wires, resin moldings, etc.). If it is difficult to do, install a nonflammable cover. ・ Across-the-line use When the ZNR is used across a line, put a current fuse in series with the ZNR(Refer to Item 3.1-1). (4) . ・ Use between line to ground (1) If the case that the ZNR is used between a line to the ground, the short-circuit of the ZNR may not blow the current fuse because of grounding resistance, which may cause smoking and ignition of the ZNR’s exterior resin. As the measure against it, install an earth leakage breaker on the power supply side of the ZNR position. If no earth leakage breaker is installed, use a thermal fuse together wth a current fuse in series. (Refer to Table 1.) (2) If the case that the ZNR is used between a live part to metal case, an electric shock may develop at a shortcircuit of the ZNR ; hence, ground the metal case to the ground or keep it from the human body. 2.3 If ZNR is shorted out and happen smoke or ignition, please cut provided current to ZNR immediately. 3. Application notes 3.1 Pay attention to the following items to avoid the shortened life and failure of the ZNR 3.1-1 Circuit conditions (1) Select a ZNR of which the maximum voltage including fluctuations in source voltage allows for the maximum permissible circuit voltage. (Refer to Table 1.) (2) In cases that surges are intermittently applied at short intervals(for example, in case that the voltage of the noise simulator test is implemented etc.), do not let them exceed the ZNR’s rated power. (3) Select a ZNR recommended in Table 1. ① Across-the-line use If possible, use a Part No. marked with * in case of voltage temporarily rises load unbalance of separately-wired loads, short between hot and neutral-line, open of neutral line in single-phase-three-wired system, and due to resonance at switching for a capacitive, inductive load. ② Used between line to ground Use a different Part No. from “Across-the-line use” as table 1, because of raising voltage in case of “Line to Ground Fault”. Use a Part No. marked with **in table 1, in case of the insulation resistance test(500 VDC) for equipment. When using a Part of the varistor voltage that the insulation efficiency examination can not be cleared, there is a case where the surge absorber can be done by removing it from the circuit depending on the circuit condition(Refer examination of Japan Domestic Safety Regulations). (4) Concerning current fuse ① We recommend selecting a ZNR and the rated current of a current fuse as follows. Finally, please be sure that there is no danger if the ZNR mounted on the equipment breaks. 14-Dec-20 c Varistors (ZNR Surge Absorber) ●D type / E, E-S1 series Standard Part No. Fuse rated current ERZE05A□□□ ERZE07A□□□ ERZE08A□□□ ERZE10A□□□ ERZE11A□□□ ERZE14A□□□ 5 A max. 7 A max. 7 A max. 10 A max. 10 A max. 10 A max. ◆ Fuses shall use rated voltages ap pro pri ate for circuits. ② The recommended fuse position is shown in table 1, “Example of ZNR application”, however, if the load current of protected equipment is larger than that of the above recommended fuse rated current, install a current fuse at the position shown below. Current fuse Protected equipment Power source side ZNR (5) Concerning thermal fuse ① Set a thermal fuse to get high thermal Table 1 Example of ZNR application Across-the-Line use Use between Line to ground DC/AC Single-phase DC/AC Single-phase fuse ZNR1 L Connections example fuse L Protected equipment N Protected equipment N ZNR2 Thermal coupling AC 3-phase ZNR1 Thermal fuse AC 3-phase fuse fuse ZNR3 ZNR3 ZNR3 Protected equipment ZNR3 Protected equipment ZNR4 Example of varistor voltage ZNR3 Thermal fuse Thermal coupling ZNR Source voltage [AC] Nominai varistor voltage ZNR 1 ZNR 3 100 V 120 V 200 V 220 V 240 V 380 V 201 to 361* 241 to 431* 471 to 621* 471 to 621* 511, 621* 751, 821* ZNR Source voltage [AC] 100 V 220 V ZNR 2 ZNR 4 230 V 240 V 380 V Nominai varistor voltage 471 511 621* 821 and more** 511 621* 821 and more** 112** 471 - Note : Element size is selected by impulse condition. 14-Dec-20 c Varistors (ZNR Surge Absorber) (6) On use for equipment The catalog guarantees the quality as individual component. Before you use the products, please make sure to check and evaluate the products in the circumstance where they are installed in your product. 3.1-2 Operating environments (1) The ZNR is designed and manufactured for application in general purpose electronic devices. The ZNR shall not be exposed to the weather, except for usage inside unit. (2) Do not use the ZNR in places exposed to temperatures beyond the operating temperature range, such as places exposed to sunlight and vicinities of heating equipment. (3) Do not use the ZNR in places exposed to high temperatures and high humidity, such as places exposed directly to rain, wind, dew condensation, and vapor. (4) Do not use the ZNR in dusty and salinity environment and atmospheres polluted by corrosive gases, in liquids such as water, oil, chemical, organic solvent. 3.1-3 Processing conditions (1) Do not wash the ZNR by such solvents(thinner, acetone, etc.) as its exterior resin deteriorates. (2) Do not apply a strong vibration or shock (by falling, etc.) to the ZNR, cracking to its exterior resin and element may occur. (3) When coating the ZNR with resin(including molding), do not use such resin. (4) Do not bend the ZNR type D lead wires at the position close to its ZNR type D exterior resin, or apply external force to the position. (5) When soldering the ZNR lead wires, follow the recommended conditions and do not melt the solder and insulating materials constituting the ZNR. (6) When designing lead-wire-terminal land-hole of circuit board, please check actual ZNR by reference specification about center value of lead-wire terminal pitch. D type Soldering method Recommended condition Attention item Flow soldering 260 ℃, within 10 seconds. D type is not reflow soldering object part. *1: Soldering iron temperature should not exceed 400 ℃ and should not be applied for mor than 5 seconds. *2: Profile be careful because there is a margin of error in the way of measuring. *3: The temperature depend on the size and the package density of the substrate. Therefore, confirm every kind of the substrate. ●Soldering temperature-time profile to recommend Temperature (°C) Flow soldering Preheating Time Soldering Gradual cooling Preheating The normal to 130 ℃ max. 120 s Soldering max. 260 ℃ max. 10 s Gradual cooling Gradual cooling 3.1-4 Long-term storage (1) Do not store the ZNR under high temperature and high humidity. Store it indoor environment at a temperature up to 40 ℃ and at humidity below 75 %RH, and use it within two years. Before using the ZNR that has been stored for a long period(two years or longer), confirm the solderability. (2) Avoid atmospheres full of corrosive gases (hydrogen sulfide, sulfurous acid, chlorine, ammonia, etc.). (3) Avoid direct sunlight and dew condensation. 3.1-5 Rated Voltage for UL or other safety certifications Our ZNR define “ Max. Allowable Voltage” and “Rated Voltage “ to keep leakage current specification and others. If you getting certificate of safety approval about your equipment with our ZNR, please follow our “Rated Voltage”. 3.1-6 Dropped product Do not drop this product on the floor. If this product is dropped, it can be damaged mechanically or electrically. Avoid using the dropped product. 14-Dec-20 c Varistors (ZNR Surge Absorber) 4. Notices ・ Our ZNR was designed and manufactured for standard applications such as general electronics devices, office equipment, information and communications equipment, measuring instruments, household appliances and audio-video equipment. ・ For applications in which special quality and reliability are required, or if the failure or malfunction of the products may directly jeopardize life or cause threat of personal injury (such as for aircraft and aerospace equipment, traffic and transport equipment, combustion equipment, medical equipment, accident prevention and anti-theft devices, and safety equipment), please be sure to consult with our sales representative in advance and to exchange product specifications which conform to such applications. ・ Applications in which special quality and reliability are required, or if the failure or malfunction of the products may. ・ Note that we do not take any responsibility for faults and abnormalities resulting from the use not in conformity with the contents of entries in the delivery specification. ・ There is a possibility that the ZNR will unexpectedly cause smoke or ignite because of an abnormal rise of the circuit voltage and invasion of excessive surge. To prevent that accident from spreading over the equipment and not to expand the damage, use multiplex protection such as the adoption of frame-retardant materials for housing parts and structural parts. 5. Applicable laws and regulations , others ・ This product not been manufactured with any ozone depleting chemical controlled under the Montreal Protocol. ・ This product comply with RoHS (Restriction of the use of certain Hazardous Substance in electrical and electronic equipment) (DIRECTIVE 2011/65/EU and (EU)2015/863). ・ All the materials used in this part are registered material under the Law Concerning the Examination and Regulationof Manufacture, etc. of Chemical Substance. ・ If you need the notice by letter of “A preliminary judgement on the Laws of Japan foreign exchange and Foreign Trade Control”, be sure to let us know. ・ These products are not dangerous goods on the transportation as identified by UN(United nations) numbers or UN classification. 6. Others ・ As to the disposal of ZNR, check the method of disposal in each country or origin where the ZNR are incorporated in your products to be used. ・ The technical information in this specification provides example of our products’ typical operations and application circuit. We do not guarantee the non-infringement of third party’s intellectual property rights and we do not grant any license, right or interest in our intellectual property. 14-Dec-20
ERZ-E11F112 价格&库存

很抱歉,暂时无法提供与“ERZ-E11F112”相匹配的价格&库存,您可以联系我们找货

免费人工找货