Quick Start Guide
Evaluation Board (EVB) PAN1311/21 USB
No.
REV.
1.1
DS-PAN1311/21USB
PAGE
1 of 11
DATE
15.09.2011
Quick Start Guide
Evaluation Board (EVB) PAN1311/21 USB
PANASONIC ELECTRONIC DEVICES EUROPE
GmbH
DESIGNED
Erstellt
IW
Quick Start Guide
Evaluation Board (EVB) PAN1311/21 USB
No.
REV.
1.1
DS-PAN1311/21USB
PAGE
2 of 11
DATE
15.09.2011
1. CONTENT
1. Content................................................................................................................................... 2
2. Introduction ............................................................................................................................ 3
2.1 Related documents............................................................................................................... 3
4. Functional overview................................................................................................................ 3
5. Connection setup ................................................................................................................... 4
5.1 Software start and navigation ............................................................................................... 4
5.2 Port configuration ................................................................................................................. 5
5.3 Firmware handling ................................................................................................................ 6
5.4 Command tab navigation...................................................................................................... 7
5.5 Creating a connection........................................................................................................... 8
6. Schematic .............................................................................................................................. 9
7. Document Information .......................................................................................................... 10
8. General Information.............................................................................................................. 11
8.1 Waiver ................................................................................................................................ 11
9. Life Support Policy ............................................................................................................... 11
PANASONIC ELECTRONIC DEVICES EUROPE
GmbH
DESIGNED
Erstellt
IW
Quick Start Guide
Evaluation Board (EVB) PAN1311/21 USB
No.
REV.
1.1
DS-PAN1311/21USB
PAGE
3 of 11
DATE
15.09.2011
2. INTRODUCTION
This document should provide the minimum knowledge needed to establish a simple
connection between two PAN1321ETU USB Evaluation Boards (EVB) using Infineon
eBMU_SPP_Toolbox software. For this limited information is granted. To learn about all
aspects of the software please refer to the related documents listed below.
2.1 RELATED DOCUMENTS
For further information on Infineon eBMU_SPP_Toolbox software and it’s implemented AT
command set please refer to:
• PAN13x1_ReleaseNote_SPP_AT_SW08_V1.8_RN_Rev1.0_DRAFT
• PAN13x1_ReleaseNote_SPP_AT_SW21_V2.1_RN_Rev1.0_DRAFT -iPhone version
• PAN13x1_SPP_AT_UserManual_SoftwareDescription_Rev5.0 DRAFT
• PAN1321_AN_DesignGuide_Rev2 1
• User's_Manual_PAN1311_V20.xx_Rev1.1
• User's_Manual_PAN1321_V20.xx_Rev3.1
4. FUNCTIONAL OVERVIEW
The figure below shows an overview of the Evaluation Board. If there is the need to connect
your µController to the EVB please de-solder R1, R2, R3, R4.
For more details please refer also to the schematic in chapter Schematic.
Hardware
Reset
Power Supply
section
For interfaces
description refer to
schematic
UART to USB
Converter Section
Figure 2 : Evaluation Board Overview
PANASONIC ELECTRONIC DEVICES EUROPE
GmbH
DESIGNED
Erstellt
IW
Quick Start Guide
Evaluation Board (EVB) PAN1311/21 USB
No.
REV.
1.1
DS-PAN1311/21USB
PAGE
4 of 11
DATE
15.09.2011
5. CONNECTION SETUP
This chapter describes how to use the eBMU_SPP_Toolbox software in order to send simple
data packages from one EVB to the other.
5.1 SOFTWARE START AND NAVIGATION
Browse to the folder where the eBMU_SPP_Toolbox.exe file is located and start it. The user
interface (figure 2) is shown.
Figure 4 : Toolbox start up screen
PANASONIC ELECTRONIC DEVICES EUROPE
GmbH
DESIGNED
Erstellt
IW
Quick Start Guide
Evaluation Board (EVB) PAN1311/21 USB
No.
REV.
1.1
DS-PAN1311/21USB
PAGE
5 of 11
DATE
15.09.2011
5.2 PORT CONFIGURATION
Please note that the eBMU Toolbox can handle only COM port numbers below 10. You can
configure in the System Hardware settings in your operating system. The USB driver can be
found in the installation folder.
On the settings tab the communication via COM port is handled. It is possible to set a
number of default parameters for both EVBs and to save/load all the changes made to this
page (saving the settings will also make the program remember the selected port numbers).
Please select the right port numbers for both EVBs (found at Windows OS: control panel
system hardware device manager Ports (COM & LPT)) and click the buttons
open/close 1 & open/close 2. A status message should appear below the text fields (figure
3). Leave the rest unchanged for now.
Figure 5 : COM port setup
PANASONIC ELECTRONIC DEVICES EUROPE
GmbH
DESIGNED
Erstellt
IW
Quick Start Guide
Evaluation Board (EVB) PAN1311/21 USB
No.
REV.
1.1
DS-PAN1311/21USB
PAGE
6 of 11
DATE
15.09.2011
5.3 FIRMWARE HANDLING
At the testing tab firmware can be downloaded (Download image) to the EVB and a number
of changes can be made to it (Change BD-data) like assigning a unique BT address (e.g.
0003199E8B73) and oscillator trim value. Make sure that the Production mode is enabled
before any of these buttons on this tab are used. To do this mark On and confirm with a click
on Production mode. The text field should inform you about of success of this procedure. Be
advised to do a hardware reset (push button on EVB) after all changes were made.
Please note:
The BD_Address and OSC_Trim value have to be read out by “Read BD Address” command
before downloading. They have to be programmed by “Change BD-data” command after
writing the new image.
Figure 6 : Testing tab
PANASONIC ELECTRONIC DEVICES EUROPE
GmbH
DESIGNED
Erstellt
IW
Quick Start Guide
Evaluation Board (EVB) PAN1311/21 USB
No.
REV.
1.1
DS-PAN1311/21USB
PAGE
7 of 11
DATE
15.09.2011
5.4 COMMAND TAB NAVIGATION
At the Commands tab are several commands listed for easy click-and-use. Note the colour
coding identifying commands by their intended usage:
•
•
•
•
•
•
•
Yellow: Settings and informational commands.
Pink: Security related commands.
Green: Connection related.
Red: Disconnection commands.
Blue: Data transfer
Light blue: Accept connection
White: Sniff (during connection)
Figure 7 : Command tab and used commands
For simple data transfer find the needed commands marked in figure 5. The Custom
Command button can be used to issue any command of the command set (refer to
PMB8753-2_SPP_AT_specification_R1.pdf).
PANASONIC ELECTRONIC DEVICES EUROPE
GmbH
DESIGNED
Erstellt
IW
Quick Start Guide
Evaluation Board (EVB) PAN1311/21 USB
No.
REV.
1.1
DS-PAN1311/21USB
PAGE
8 of 11
DATE
15.09.2011
5.5 CREATING A CONNECTION
To send data from one EVB to the other one of them must be prepared for connection, while
the other will request a connection. Follow these steps:
1. Click on Make Discoverable on Device A. Choose option 3: Inquiry_Page Scan
enabled. The text field should state the issued command sent ( arrow) and the OK
response ( arrow). Now device A can be found by other devices by both available
scan methods.
2. Click on Register Local Service. There are some options to change identification of
the new service but the default values are ok. Simply choose Send. This service now
can be found by other devices of the network.
3. Click the Auto Accept Connection Requests command and choose option 1. EVB A
will auto accept connection requests from now on. Device A is now ready for
connection!
4. Get the address of EVB A with the help of Read BD Address. In the text field you will
find the desired information (e.g. “[…]