HG-TC111

HG-TC111

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    HG-T SUB CONTROLLER NPN

  • 数据手册
  • 价格&库存
HG-TC111 数据手册
CMOS Type Thru-beam Type Digital Displacement Sensor HG-TSERIES (Excluding SC-HG1-USB) The Industry’s Highest-Class Measurement Accuracy Is Now Yours. * * Among thru-beam type digital sensors, as of January 2019 in-company survey 2019.02 industrial.panasonic.com/ac/e/ S e n s o r H e a d Ultra-slim HG-T series 8 mm 0.315 in The ultra-slim unit with a thickness of 8 mm 0.315 in allows easy installation in a limited space such as the inside of equipment. Wide-angle measurement The belt-shaped laser beam with a measurement width of 10 mm 0.394 in is used for measurement of dimensions and positions. Industry’s highest*1 measurement accuracy The HG-T series boasts repeatability*2 of 1 μm 0.039 mil and offers the highest*1 measurement accuracy in the industry. Emitter Receiver Installation distance 20 mm 0.787 in Installation distance 100 mm 3.937 in Measurement width 10 mm 0.394 in Installation distance 500 mm 19.685 in Repeatability*2  0.12 % F.S. 1 μm • Linearity: ±(±12 μm) 0.039 mil • Average count: 16 times  0.28 %F.S. 2.5 μm • Linearity: ±(±28 μm) 0.098 mil • Average count: 16 times 5 μm • Average count: 16 times 0.197 mil ●Sampling cycle setting can be selected from two options. Standard: 1 ms, High speed: 0.5 ms. ●Average count setting can be selected from 11 options. 1 time, 2 times, 4 times, 8 times, 16 times, 32 times, 64 times, 128 times, 256 times, 512 times, 1,024 times *1 As of January 2019, in-company survey *2 This is the P-P value of digital measurement value with half shading at the middle position of the installation distance. Two types of sensor heads are available. Two types of sensor heads, one with a standard type receiver and the other with a slim type receiver, are available. Standard type HG-T1010 30 mm 1.181 in 8 mm 0.315 in Slim type HG-T1110 8 mm 0.315 in 20 mm 0.787 in Side view attachment is available (optional). HG-T1010 Side view attachment (optional) is available for the standard type sensor head HG-T1010. This attachment can bend the laser beam at a right angle to allow flexible installation of the sensor head. ■Application example: Side view attachment Lithium-ion battery winding section HG-TSV10 Conventional sensor head Two M2 (length 4 mm 0.157 in) screws with washers are attached. Sensor head mounted with side view attachment HG-T1010 60 mm 2.362 in 60 mm 2.362 in * Illustration prepared to show the difference. Receiver Receiver 2 Receiver Emitter Use of the side view attachment enables the installation of the sensor head closer to the winding section than when a conventional sensor head is used, thus contributing to the improvement of winding accuracy. * Two side view attachment units are required when using the attachment on both emitter and receiver. * The slim type sensor head HG-T1110 cannot be mounted with the side view attachment. * Be sure to confirm proper detection using actual equipment in advance when using the side view attachment. HG-T SERIES Ease of Installation Automatic emitter / receiver cable recognition Beam axis adjustment assist function The standard type sensor head HG-T1010 indicates the direction of receiver displacement relative to the emitter on the controller’s display screen and with the beam axis adjustment indicators on the receiver in an easy-to-understand fashion. * The slim type sensor head HG-T1110 displays the displacement information only on the controller’s display section. When beam axis is aligned properly Circle meter Green (OK) / No unlit indicator segment Receiver (1) Static display Circle meter Orange (NG) / A few unlit indicator segments Receiver Only the beam axis adjustment indicator on the TOP side is ON. Adjust the position toward the TOP side. Emitter Display prompting the adjustment of the position of the receiver toward the TOP side When beam axis is displaced significantly toward the TOP side * The sensor head connection cable is branched into two cables on the sensor head connecting side, but the two cables can be connected interchangeably to the emitter and receiver. Die-cast aluminum case The sensor head case is made of light and strong die-cast aluminum. It minimizes measurement fluctuations due to temperature effects. The die-cast aluminum case does not easily become distorted in shape by tightening of mounting screws as compared to a resin case. It is highly resistant to deterioration due to ageing. This robust case helps prevent deviations of beam axis alignment. Die-cast aluminum case Adjust the position Orange (NG) / Many unlit toward the BOTTOM side. indicator segments Only the beam axis adjustment indicator on the BOTTOM side is ON. Emitter (2) (1) Emitter and (2) Receiver OR (1) Receiver and (2) Emitter Emitter and receiver can be connected to either connectors! When beam axis is displaced slightly toward the BOTTOM side Receiver Sensor head connection cable Sensor head Both beam axis adjustment indicators are ON. Emitter The HG-T series automatically recognizes the positional relationship of the emitter and receiver connected to the sensor head connection cable at the time the controller is turned ON. This function eliminates the need for identifying the correct cables to connect to the emitter and receiver. Wiring can be completed by simply attaching Controller the connectors to the emitter and receiver. Display prompting the adjustment of the position of the receiver toward the BOTTOM side IP67 protection The HG-T series features a protection structure of IP67 (IEC) so it can be used in a place where the product may be exposed to water or large amounts of dust. * Note that if the beam emitting / receiving surfaces of the sensor head are adhered with water or dust, correct measurements become inaccurate. * The sensor head is watertight, but the connectors are not structurally resistant to dust, water or corrosion. Therefore, the HG-T series cannot be submerged in water or placed under falling water for measurement operation. Be sure to use the product in an appropriate environment. 3 C o n t r o l l e r High-performance Controller Dual display for added indication flexibility (equipped with NAVI function) The 2-line digital display simultaneously shows head measurement (measured value) and judgment value (calculated value). All-direction LCD The high-contrast LCD provides sharp and clear indications and wide viewing angle. Equipped with intuitive circle meter Values between allowable maximum and minimum values are indicated in green. Values outside of the allowable range are indicated in orange. This provides at-a-glance understanding of the margin to the tolerance limits. Higher than maximum value Lower than minimum value Five types of detection modes Industry’s First!* Auto edge detection mode Edge detection can be started from either the TOP or BOTTOM without registering the detection direction. This eliminates the need for checking the detection direction. * As of January 2019, according to in-company survey Edge detection mode TOP BOTTOM TOP BOTTOM External form / width detection mode TOP BOTTOM Inside diameter / gap detection mode TOP BOTTOM Central position detection mode b a c b a c TOP 4 BOTTOM TOP BOTTOM HG-T SERIES Monitoring of effects caused by stains Notifies when the detection performance decreases due to accumulated stains. Amount of received light Checks the degree of contamination based on the amount of light of the reference waveform (considered as 100 %). Reference waveform Reference waveform Threshold value TOP BOTTOM Decrease in the amount of received light due to accumulated stains Amount of received light Reference waveform Threshold value TOP BOTTOM An alarm is output when the amount of received light decreases below the threshold value, with the condition of the reference waveform considered as 100 %. Stain check setting items One of the following four settings can be selected. • Low sensitivity setting ON (LOW) [default] • High sensitivity setting ON (HIGH) • User setting ON (USER) Adjustable in the range of 50 to 95 % • Stain check OFF (OFF) Alarm output * The reference waveform can be confirmed by using the “HG-T Configuration Tool” USB-based PC setting software and SC-HG1-USB USB communication unit. For details, refer to page 6. Stable measurement of even transparent workpieces The judgment level can be adjusted according to the degree of transparency. When workpiece is opaque Problem caused by transparent workpiece Emitter Emitter Opaque workpiece Receiver 0% Emitter Transparent workpiece Transparent workpiece Receiver 100 % Amount of received light When workpiece is transparent Receiver 100 % 100 % Amount of received light Judgment level 25 % 0% Opaque workpiece completely blocks the light to the CMOS. Judgment level: Lower than 25 % Position measurement is possible. Judgment level 60 % Amount of received light Judgment level 25 % 25 % 0% Judgment level: Change to 60 % Light to the CMOS is not completely blocked, but the amount of received light is lower than the judgment level and position measurement is possible. Tansparent workpiece does not block the light to the CMOS. Judgment level: Higher than 25 % Position measurement is not possible. Elimination of effects caused by fine foreign matters The judgment filter value can be adjusted for the prevention of erroneous detections due to fine foreign matters. The judgment filter value can be set to a desired value between 3 and 50. Foreign matter Example) Judgment filter value set to 3 Workpiece Receiver Emitter 1 2 3 1 2 1 2 1 2 3 4 5 6 Light interception section consists of only 2 continuous pixels, judging that the light is received. Light interception section consists of 3 or more continuous pixels, judging that the light is blocked. Accumulation of foreign matters Increase the filter value! Value resulting from foreign matters Increasing the filter value ignores values resulting from 半透明体の測定 フィルタ値を小さく! foreign matters. フィルタ値が 5 T o o l S o f t w a r e Convenient Tool Software Combined use of the USB-based PC setting software, “HG-T Configuration Tool,” and the USB communication unit, “SC-HG1-USB,” enables confirmation and change of current values and settings in the HG-T series using a PC. USB-based PC setting software HG-T Configuration Tool Settings such as name, judgment level and filter value can be changed for each controller while observing the waveform. • Compatible communication unit: SC-HG1-USB • Supported OS: M  icrosoft Windows® 7 (32-bit / 64-bit)*1, Microsoft Windows® 8 (8.1) (32-bit / 64-bit), Microsoft Windows® 10 (32-bit / 64-bit) • Required hard disk space: 100 MB or more • Required USB port: USB 2.0 *1 In the case of a PC running Microsoft Windows® 7, “Microsoft .NET Framework 4.5.1” is required. *2 M  icrosoft and Windows are registered trademarks or trademarks of Microsoft Corporation in the U.S. and/or other countries. The USB-based PC setting software, “HG-T Configuration Tool,” can be downloaded free from our website. System configuration Connecting to PLC Connecting to PC Field network master unit Sensor head Sensor head USB PLC PC RS-485 Controller Controller CC-Link IE Field communication unit CC-Link communication unit RS-485 communication unit Communication units for field networks such as CC-Link as CC-Link IE Field are available so the HG-T series can be linked with a production system for IoT application. 6 USB-based PC setting software (HG-T Configuration Tool) HG-T SERIES Applications Measurement of meandering on lithium-ion battery winding machine Thanks to the compact design, the sensor head can be installed at a location close to the winding core. This improves the meander measurement accuracy. Glass substrate positioning The judgment level adjustment function ensures stable detection and measurement of even transparent workpieces. Detection of clearance between rollers The clearance between rollers can be measured for stabilizing the workpiece quality. The compact head is easy to install. Shaft diameter measurement Measurement of motor shaft eccentricity Shaft diameters can be measured. The original head structure and proprietary algorithm achieve stable detection without being affected by secondary reflections by metal surfaces. Shaft eccentricity can be measured by using the central position detection mode and measuring the distance to the shaft center. 7 C o m m u n i c a t i o n U n i t Communication unit for digital displacement sensor Directly send the measurement values of multiple sensors to a host! CC-Link IE Field / CC-Link communication unit The communication unit for digital displacement sensor can be used to connect directly to a CC-Link / CC-Link IE Field network. This lets you acquire digital data and ON / OFF information in real-time without a program. In addition, you can change controller settings and log measurement data via the CC-Link / CC-Link IE Field network, so you can also use the system for preventative maintenance of digital displacement sensors. Cloud server Production execution system Equipment maintenance and management Production instruction terminal PLC Hub High-accuracy data PLC Local SC-HG1-CEF High-accuracy data SC-HG1-CEF Connection of 1 master unit and up to 14 slave units (Note) Display PLC Master High-accuracy data High-accuracy data PLC Master SC-HG1-C SC-HG1-C Connection of 1 master unit and up to 14 slave units (Note) Note: When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit CC-Link IE Field communication unit CC-Link communication unit Communication speed: 1 Gbps Communication speed: 10 Mbps (max.) SC-HG1-CEF 8 iQSS support is planned SC-HG1-C Supports iQSS HG-T SERIES USB communication unit The USB communication unit provides convenient functions that facilitate the setting of the HG-T series while observing the waveform of received light by operating the dedicated USBbased PC setting software. The USB-based PC setting software can be downloaded free from our website. USB connection High-accuracy data Connection of 1 master unit and up to 14 slave units*1 PC USB-based PC setting software USB communication unit HG-T Configuration Tool SC-HG1-USB • Compatible communication unit:SC-HG1-USB • Supported OSs: M  icrosoft Windows® 7 (32-bit / 64-bit)*3, Microsoft Windows® 8 (8.1) (32-bit / 64-bit), Microsoft Windows® 10 (32-bit / 64-bit) • Required hard disk space: 100 MB or more • Required USB port: USB 2.0 Communication specification: USB 2.0 Full Speed*2 Communication protocol: Proprietary protocol USB port: USB Mini-B (1 port) *1 When connected to the communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit. *2 Dependent on PC environment. *3 In the case of a PC running Microsoft Windows® 7, “Microsoft .NET Framework 4.5.1” is required. *4 Microsoft and Windows are registered trademarks or trademarks of Microsoft Corporation in the U.S. and/or other countries. RS-485 communication unit For use of high-accuracy measurement results as traceability data examples. Transfers not only measurements results obtained at multiple points but also setting statuses as digital data in a batch. Provides powerful support to the management of inspection records and identification of failure causes. Analysis, cause investigation, etc. Ethernet Web server Programmable Controller SC-HG1-485 RS-485 communication High-accuracy data Data logging, etc. FP7 SERIES RS-485 communication protocol MODBUS (RTU / ASCII): Connection of up to 99 stations MEWTOCOL-COM: Connection of up to 64 stations High-accuracy data RS-485 communication unit SC-HG1-485 Connection of 1 master unit and up to 14 slave units* * When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit. Communication speed: 1.2 kbps / 2.4 kbps / 4.8 kbps / 9.6 kbps / 19.2 kbps / 38.4 kbps / 57.6 kbps / 115.2 kbps 9 HG-T ORDER GUIDE Sensor heads Type Measurement width Appearance Installation distance Standard type Emitter: 8 × 30 × 60 mm 0.315 × 1.181 × 2.362 in Receiver: 8 × 30 × 60 mm 0.315 × 1.181 × 2.362 in Measurement width 10 mm 0.394 in Repeatability (Note 1) Laser class HG-T1010 1 μm 0.039 mil Installation distance: 20 mm 0.787 in 10 mm 0.394 in 0 to 500 mm 0 to 19.685 in Class 1 IEC / JIS / GB / FDA (Note 2) 2.5 μm 0.098 mil Installation distance: 100 mm 3.937 in 5 μm 0.197 mil Installation distance: 500 mm 19.685 in Slim type Model No. HG-T1110 Emitter: 8 × 30 × 60 mm 0.315 × 1.181 × 2.362 in Receiver: 8 × 20 × 60 mm 0.315 × 0.787 × 2.362 in Notes: 1) This is the P-P value of digital measurement value with half shading at the middle position of the installation distance. 2) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). Sensor head connection cables Type Appearance Sensor head connection cables Model No. Cable length CN-HT-C2 2 m 6.562 ft CN-HT-C5 5 m 16.404 ft CN-HT-C10 10 m 32.808 ft CN-HT-C20 20 m 65.617 ft Description This cable is used to connect the sensor head to the controller. The cable is branched into two cables on the sensor head connecting side, but the two cables can be connected interchangeably to the emitter and receiver. Controllers Type Master unit Appearance Model No. HG-TC101 NPN open-collector transistor HG-TC101-P PNP open-collector transistor HG-TC111 NPN open-collector transistor HG-TC111-P PNP open-collector transistor High performance type High performance type Slave units Wire-saving type Output HG-TC113 Maximum number of connectable controllers Up to 15 slave units can be connected per master unit (Note) — Note: When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit. 10 HG-T ORDER GUIDE Communication units for digital displacement sensors Type Appearance USB communication unit (Note 1) CC-Link IE Field communication unit CC-Link communication unit RS-485 communication unit Model No. Description SC-HG1-USB When used together with the “HG-T Configuration Tool” USB-based PC setting software, current values and settings in the HG-T series can be confirmed or changed on the PC screen. * The USB-based PC setting software, “HG-T Configuration Tool,” can be downloaded free from our website. • Communication specification: USB 2.0 Full Speed (Note 2) • Communication protocol: Proprietary protocol • USB port: USB Mini-B (1 port) • Number of connectable units Controller: Up to 15 units (1 master unit, 14 slave units) per SC-HG1-USB unit SC-HG1-CEF Can directly send high-accuracy measurement values to a CC-Link IE Field host device. • Communication method CC-Link IE Field • Number of connected units Host (CC-Link IE Field): Max. 121 units (1 master station, 120 slave stations) Controllers: Maximum of 15 units (1 master, 14 slaves) per SC-HG1-CEF unit SC-HG1-C Can directly send high-accuracy measurement values to CC-Link Master. • Communication method Switchable CC-Link Ver.1.10 or 2.00 • Number of occupied station CC-Link Ver.1.10: 4 stations, CC-Link Ver.2.00: Switchable 2 or 4 stations • Number of connected units Controllers: Maximum of 15 units (1 master, 14 slaves) per SC-HG1-C unit SC-HG1-485 Can directly send high-accuracy measurement values by RS-485 communication • Communication protocol MODBUS (RTU / ASCII) / MEWTOCOL-COM • Number of connected units Host (RS-485): 1 to 99 units when MODBUS (RTU / ASCII) is used, 1 to 64 units when MEWTOCOL-COM is used Controllers: Maximum of 15 units (1 master, 14 slaves) per SC-HG1-485 unit Notes: 1) The USB communication unit cannot be used with contact-type digital displacement sensors HG-S series. 2) Dependent on PC environment. End plates Type Appearance Model No. MS-DIN-E End plates Description 2 pcs. per set Always use this when connecting controllers and a digital displacement sensor communication unit. Model No. Description OPTIONS Type Side view attachment Computer software for CC-Link IE Field / CC-Link Appearance HG-TSV10 Designed for exclusive use with the HG-T1010 standard type sensor head. This attachment can bend the laser beam at a right angle, thus allowing flexible installation of the sensor head. Two M2 (length 4 mm 0.157 in) screws with washers are attached. * Two pieces of attachment are required when using the attachment on both emitter and receiver. *B  e sure to confirm proper detection using actual equipment in advance when using the attachment. SC-PC1 A PC installed with this software can be used to monitor the current values of the digital displacement sensor, to create a CSV file of setting information, to display the log data, to create a CSV file of log data, etc. via Mitsubishi Electric PLC (MELSEC series). • Compatible communication units for digital displacement sensor: SC-HG1-CEF, SC-HG1-C • Supported OS: Microsoft Windows® 7 (32-bit), Japanese version • Required hard disk space: 50 MB or more Note: Microsoft and Windows are registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. 11 HG-T SPECIFICATIONS Sensor heads Type Measurement width 10 mm 0.394 in / Standard type Item Model No. Regulatory compliance Compatible controller Measurement width 10 mm 0.394 in / Slim type HG-T1010 HG-T1110 EMC Directive, RoHS Directive, FDA regulations HG-TC101 (-P), HG-TC111 (-P), HG-TC113 Position detection method CMOS-based Installation distance 0 to 500 mm 0 to 19.685 in Measurement width 10 mm 0.394 in Red semiconductor laser: Class 1 [IEC / JIS / GB / FDA (Note 2)] Maximum output: 0.3 mW, Peak emission wavelength: 655 nm Light source Repeatability (Note 3) 1 μm 0.039 mil (Installation distance: 20 mm 0.787 in) 2.5 μm 0.098 mil (Installation distance: 100 mm 3.937 in) 5 μm 0.197 mil (Installation distance: 500 mm 19.685 in) ±0.12 % F.S. (Installation distance: 20 mm 0.787 in) ±0.28 % F.S. (Installation distance: 100 mm 3.937 in) Linearity (Note 4) Minimum sensing object (Note 5) ø0.5 mm ø0.020 in (Installation distance: 500 mm 19.685 in) Temperature characteristics (Note 6) Emitter Operation indicator Receiver ±0.03 % F.S./°C Laser radiation indicator (Green) Beam axis adjustment indicator (Orange / Green), Judgment output indicator (Orange / Green) Pollution degree Environmental resistance Operating altitude Protection Ambient temperature Ambient humidity Ambient illuminance Judgment output indicator (Orange / Green) 2 2,000 m 6,561.68 ft or less (Note 8) IP67 (IEC) (Excluding connectors) -10 to +45 °C +14 to +113 °F (No dew condensation or icing allowed), Storage: -20 to +60 °C -4 to +140 °F 35 to 85 % RH, Storage: 35 to 85 % RH Incandescent light: 5,000 lx or less at the light-receiving face (Note 7) Insulation resistance 20 MΩ or higher, using 250 V DC megger (between all terminals and case) Vibration resistance 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each Shock resistance Grounding method Material Cable Net weight 196 m/s2 acceleration in X, Y and Z directions three times each Capacitor grounding Case: Die-cast aluminum, Light emitting and light receiving surfaces: Glass 0.2 m 0.656 ft 4-core shielded cable with round connectors Emitter: 30 g approx., Receiver: 30 g approx. Emitter: 30 g approx., Receiver: 25 g approx. Notes: 1) Specification values are based on the digital measurement values obtained by the sensor head and controller HG-TC□. Where measurement conditions have not been specified precisely, the conditions used were as follows: ambient temperature = +20 °C +68 °F, controller’s average count setting 16 times, measurement target = nontransparent knife edge, installation distance = 100 mm 3.937 in, positional condition of measurement target = Half shading at the middle position of installation distance. 2) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). 3) This is the P-P value of digital measurement value with half shading at the middle position of the installation distance. 4) Indicates an error with the ideal straight line of digital measured values. 5) When the light is blocked at the center position of 500 mm 19.685 in installation distance 6) When the light is half-blocked at the center position of 100 mm 3.937 in installation distance 7) When the sampling cycle of the controller is set to “standard sampling” 8) Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m. 12 HG-T SPECIFICATIONS Controller Model No. Type Item Master unit Slave unit High performance type NPN output HG-TC101 HG-TC111 PNP output HG-TC101-P HG-TC111-P Regulatory compliance HG-T1010, HG-T1110 Up to 15 slave units can be connected to a master unit. (Note 2) Supply voltage 24 V DC ±10 %, including ripple 0.5 V (P-P) Current consumption (Note 3) Analog outputs (Switching type) (Note 4) HG-TC113 EMC Directive, RoHS Directive Compatible sensor head Number of connectable units Wire-saving type High performance type 100 mA or less (when sensor head is connected) Analog voltage output •• Voltage output range: 1 to 5 V/F.S. (default value) •• Linearity: ±0.05 % F.S. •• Output when alarm occurs: 5.2 V •• Output impedance: 100 Ω max. ── Analog current output •• Current output range: 4 to 20 mA/F.S. (default value) •• Linearity: ±0.25 % F.S. •• Output when alarm occurs: 0 mA •• Load impedance: 250 Ω max. ── Control outputs (Output 1, Output 2, Output 3) NPN open-collector transistor PNP open-collector transistor •• Maximum sink current: 50 mA (Note 5) •• Maximum source current: 50 mA (Note 5) •• Applied voltage: 30 V DC or less (between output and 0 V) •• Applied voltage: 30 V DC or less (between output and +V) •• Residual voltage: 1.5 V or less (at 50 mA sink current) •• Residual voltage: 1.5 V or less (at 50 mA source current) •• Leakage current: 0.1 mA or less •• Leakage current: 0.1 mA or less Short-circuit protection Incorporated (automatic reset type) Judgment output N.O. / N.C. switching type Alarm output Open when alarm occurs External output switching Output 1, Output 2, and Output 3 can be switched to 3-value, 2-value, Logic, and Logic 2. External inputs (Input 1, Input 2, Input 3) Non-contact input or NPN open-collector transistor •• Input conditions Invalid: +8 V to +V DC or open Valid: 0 to +1.2 V DC •• Input impedance: 10 kΩ approx. Input time 2 ms or more (ON) Laser emission stop input Input time 20 ms or more (ON) Preset input Input time 20 ms or more (ON) Reset input Input time 20 ms or more (ON) Bank input A / B (Note 6) ── Input time 20 ms or more (ON) Input 1, Input 2, and Input 3 can be switched to “Preset / Reset / Trigger”, “Bank Input A / Bank Input B / Select (Preset, Reset, Trigger)”, or “Laser emission stop”. Sampling cycle ── 1 ms (standard sampling) / 0.5 ms (high-speed sampling) Average count (response time) (Note 6) 1 time (2 ms), 2 times (3 ms), 4 times (5 ms), 8 times (9 ms), 16 times (17 ms), 32 times (33 ms), 64 times (65 ms), 128 times (129 ms), 256 times (257 ms), 512 times (513 ms), and 1,024 times (1,025 ms) switching type Display resolution 1 μm 0.039 mil Display range -199.999 to 199.999 mm -7.874 to 7.874 in Pollution degree 2 Operating altitude Environmental resistance ── Non-contact input or PNP open-collector transistor •• Input conditions Invalid: 0 to +0.6 V DC or open Valid: +4 V to +V DC •• Input impedance: 10 kΩ approx. Trigger input External input switching ── 2,000 m 6561.68 ft or less (Note 7) Protection IP40 (IEC) Ambient temperature -10 to +50 °C +14 to +122 °F (No dew condensation or icing allowed) (Note 5), Storage: -20 to +60 °C -4 to +140 °F Ambient humidity Voltage withstandability 35 to 85 % RH, Storage: 35 to 85 % RH 1,000 V AC for one minute between all supply terminals connected together and enclosure Insulation resistance 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 to 58 Hz), Maximum acceleration 49 m/s2 (58 to 150 Hz) in X, Y and Z directions for two hours each Shock resistance Material Cable Net weight 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each Case: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal 0.2 mm2 2-core (brown and blue lead wires) / 0.15 mm2 7-core composite cable, 2 m 6.562 ft long 0.15 mm2 7-core composite cable, 2 m 6.562 ft long ── 140 g approx. 140 g approx. 60 g approx. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage +24 V DC, ambient temperature +20 °C +68 °F. 2) When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit. 3) Current consumption does not include analog current output. 4) Linearity is a value calculated from digitally measured values at F.S. = 16 mA for current output or F.S. = 4 V for voltage output. 5) When slave units are connected to the master unit, the maximum sink current / source current of control output and ambient temperature vary depending on the number of connected slave units as shown below. Number of connected slave units Wen communication unit is connected 1 to 7 units 1 to 6 units 8 to 15 units 7 to 14 units Maximum sink current and source current of control output Ambient temperature 20 mA 10 mA -10 to +45 °C +14 to +113 °F 6) Average count (response time) is for when the sampling cycle is set to 1 ms (standard sampling). Response times differ when the sampling cycle is set to 0.5 ms (high-speed sampling). 7) Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m. 13 HG-T SPECIFICATIONS Communication units for digital displacement sensors Supply voltage (Note 3) Environmental resistance Current consumption Communication method Communication protocol USB port Pollution degree / Operating altitude Protection Ambient temperature Ambient humidity Voltage withstandability Insulation resistance Vibration resistance Shock resistance Material Weight HG-TC□ Maximum of 15 controllers (one master, 14 slaves) per SC‑HG1‑USB unit 24 V DC ±10 %, including ripple 0.5 V (P-P) (Within specified power supply voltage range) 50 mA or less USB 2.0 Full Speed (Note 4) Our dedicated protocol USB Mini-B (1 port) 2 / 2,000 m 6561.680 ft or less (Note 5) IP40 (IEC) -10 to +45 °C +14 to +113 °F (No dew condensation or icing allowed), Storage: -20 to +60 °C -4 to +140 °F 35 to 85 % RH, Storage: 35 to 85 % RH 1,000 V AC for one min. between all supply terminals connected together and enclosure 20 MΩ or more, with 250 V DC megger 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 to 58 Hz), Maximum acceleration 49 m/s2 (58 to 150 Hz) in X, Y and Z directions for two hours each 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each Enclosure: Polycarbonate Net weight: 35 g approx., Gross weight: 95 g approx Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. 2) USB 2.0 (Mini-B) cable for the connection of a PC is not provided with the product. Please purchase a USB 2.0 (Mini-B) cable. 3) Power is supplied from a connected controller / master unit. 4) Dependent on PC environment. 5) Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m. Designation Model No. Item Regulatory compliance Compatible controllers Maximum number of connectable controllers Supply voltage (Note 2) Current consumption Communication method Remote station type Network No. setting Environmental resistance Cyclic transmission (Maximum number of links per station) Transient transmission Station No.setting Baud rate Transmission line types Maximum transmission distance Maximum number of connectable units Cascade connection levels Pollution degree / Operating altitude Protection Ambient temperature Ambient humidity Voltage withstandability Insulation resistance Vibration resistance Shock resistance Material Communication cable Weight CC-Link IE Field communication unit SC-HG1-CEF EMC Directive, RoHS Directive HG-TC□, HG-SC□ Maximum of 15 controllers (one master, 14 slaves) per SC‑HG1‑CEF unit 24 V DC ±10 %, including ripple 0.5 V (P-P) 200 mA or less CC-Link IE Field Remote device station 1 to 239 (decimal) [1 to EF (hex)] (0 and 240 or more: Error) (Note 3) RX / RY: 128 points each (128 bits), 16 bytes RWr / RWw: 64 points each (64 words), 128 bytes Server function only, data size 1,024 bytes 1 to 120 (decimal) (0 and 121 or more: Error) 1 Gbps Line, star (mixing of line and star types is possible), ring 100 m 328.084 ft 121 units (1 master station, 120 slave stations) Maximum 20 2 / 2,000 m 6561.680 ft or less (Note 4) IP40 (IEC) -10 to +45 ºC +14 to +113 °F (No dew condensation or icing allowed), Storage: -20 to +60 ºC -4 to +140 °F 35 to 85 % RH, Storage: 35 to 85 % RH 1,000 V AC for one min. between all supply terminals connected together and enclosure 20 MΩ or more, with 250 V DC megger between all supply terminals connected together and enclosure 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 to 58 Hz), Maximum acceleration 49 m/s2 (58 to 150 Hz) in X, Y and Z directions for two hours each 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each Enclosure: Polycarbonate Ethernet cable that satisfies 1000BASE-T standard Category 5e or higher (Double-shielded / STP, straight cable) (Note 5) Net weight: 100 g approx.,Gross weight: 150 g approx. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. 2) Power is supplied from a connected controller / master controller. 3) For the network No. setting on this product, convert the network number to hex and set the hex value. 4) Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m. 5) Use CC-Link Partner Association recommended cable. 14 Designation Model No. Item CC-Link communication unit SC-HG1-C Regulatory compliance EMC Directive (Note 2), RoHS Directive Compatible controllers HG-TC□, HG-SC□ Maximum number of Maximum of 15 controllers (one master, 14 slaves) per SC‑HG1-C unit connectable controllers Supply voltage (Note 3) 24 V DC ±10 %, including ripple 0.5 V (P-P) Current consumption 80 mA or less Communication method Switchable CC-Link Ver.1.10 or 2.00 Remote station type Remote device station Number of occupied station CC-Link Ver.1.10: 4 stations, CC-Link Ver.2.00: Switchable 2 or 4 stations Station No. setting 1 to 64 (0 and 65 or more: Error) Baud rate 10 Mbps 5 Mbps 2.5 Mbps 625 kbps 156 kbps Maximum transmission 100 m 160 m 400 m 900 m 1,200 m distance 328.084 ft 524.934 ft 1,312.336 ft 2,952.756 ft 3,937.008 ft Pollution degree / 2 / 2,000 m 6561.680 ft or less (Note 4) Operating altitude Protection IP40 (IEC) Ambient -10 to +45 °C +14 to +113 °F (No dew condensation or icing temperature allowed), Storage: -20 to +60 °C -4 to +140 °F Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH Voltage 1,000 V AC for one min. between all supply terminals withstandability connected together and enclosure Insulation 20 MΩ or more, with 250 V DC megger between all supply resistance terminals connected together and enclosure 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 Vibration to 58 Hz), Maximum acceleration 49 m/s2 (58 to 150 Hz) in X, resistance Y and Z directions for two hours each 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions Shock resistance five times each Material Enclosure: Polycarbonate Communication cable Specified cable (shielded twisted cable) (Note 5) Weight Net weight: 80 g approx., Gross weight: 130 g approx. Environmental resistance Compatible controllers Maximum number of connectable controllers USB communication unit SC-HG1-USB Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. 2) If our product will be incorporated in a customer product that will comply with the EMC Directive, install our product in a conductive box in accordance with “PLC User’s Manual [Published by Mitsubishi Electric Corporation]”. 3) Power is supplied from a connected controller / master controller. 4) Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m. 5) Use only a special-use communication cable that is approved by the CC-Link Partner Association. Designation Model No. Item Regulatory compliance Compatible controllers Supply voltage (Note 2) Current consumption Communication method Synchronization method Communication protocol Baud rate Electrical characteristics Host Number of connectable (RS-485) units Sensors Stop bit length Parity check Data bit length Pollution degree / Operating altitude Protection Ambient temperature Ambient humidity Voltage withstandability Insulation resistance Environmental resistance Designation Model No. Item Vibration resistance Shock resistance Material Total extension distance Weight Accessory RS-485 communication unit SC-HG1-485 EMC Directive, RoHS Directive HG-TC□, HG-SC□ 24 V DC ±10 %, Ripple P-P 10 % or less (Within specified power supply voltage range) 40 mA or less Two-wire half duplex communication Start-stop synchronization MODBUS (RTU / ASCII) / MEWTOCOL-COM 1.2 kbps / 2.4 kbps / 4.8 kbps / 9.6 kbps / 19.2 kbps / 38.4 kbps / 57.6 kbps / 115.2 kbps Complies with EIA RS-485 1 to 99 units when MODBUS (RTU / ASCII) is used, 1 to 64 units when MEWTOCOL-COM is used Maximum of 15 controllers (1 master, 14 slaves) per SC-HG1-485 unit 1 bit / 2 bits Even / Odd / None 8 bits (RTU) / 7 bits (ASCII) 2 / 2,000 m 6561.680 ft or less (Note 3) IP40 (IEC) -10 to +45 °C 14 to +113 °F (No dew condensation or icing allowed), Storage: -20 to +60 °C -4 to +140 °F 35 to 85 % RH, Storage: 35 to 85 % RH 1,000 V AC for one min. between all supply terminals connected together and enclosure 20 MΩ or more, with 250 V DC megger between all supply terminals connected together and enclosure 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 to 58 Hz), Maximum acceleration 49 m/s2 (58 to 150 Hz) in X, Y and Z directions for two hours each 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each Enclosure: Polycarbonate Communication cable: 1,200 m 3,937.008 ft or less between SC-HG1-485 (terminal) and PLC Net weight: 75 g approx., Gross weght: 120 g approx. Termination resistor switching jumper pin: 1 pc. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. 2) Power is supplied from a connected controller / master controller. 3) Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m. HG-T For communication unit for digital displacement sensors, refer to the instruction manual. The instruction manual can be downloaded from our website. I/O CIRCUIT DIAGRAMS NPN output type PNP output type HG-TC101 / Master unit HG-TC101-P / Master unit Color code +V Color code +V (Brown) +V (Brown) +V (Black) Output 1 *1 Load (Pink) External input 1 Load *1 Load (White) Output 2 *1 (Purple) External input 2 (Black / Grey) Output 3 – (Pink) External input 1 24 V DC ±10 % (Pink / Purple) External input 3 Main circuit Main circuit + – (White) Output 2 *1 Load *1 (Black / Grey) Output 3 *1 (Blue) 0 V (Blue) 0 V (Grey) Analog current output (Shield) Analog ground (Note) AGND Internal circuit 0V Connect to +V (Brown) of HG-TC101-P HG-TC111-P / Slave unit Color code Load *1 (Pink) External input 1 Load 0V Analog input device Users’ circuit Color code (Black) Output 1 Load (Shield) Analog ground (Note) AGND Internal circuit Connect to +V (Brown) of HG-TC101 Load (Grey) Analog current output Analog input device Users’ circuit HG-TC111 / Slave unit *1 Load (White) Output 2 24 V DC ±10 % (Black) Output 1 (Purple) External input 2 (Pink / Purple) External input 3 + *1 (Purple) External input 2 (Black / Grey) Output 3 Main circuit Main circuit (Pink / Purple) External input 3 (Pink) External input 1 (Purple) External input 2 (Black) Output 1 (White) Output 2 *1 (Pink / Purple) External input 3 Load *1 (Black / Grey) Output 3 *1 (Blue) 0 V (Shield) Analog ground (Note) AGND * 1 Internal circuit (Grey) Analog current output Analog input device Users’ circuit Non-voltage contact or NPN open collector transistor or 0 to +1.2 V DC: Effective +8 V to +V DC or open: Ineffective Note: Use shielded wire for the analog output. PRECAUTIONS FOR PROPER USE •• This catalog is a guide to select a suitable product. Be sure to read instruction manual attached to the product prior to its use. •• Never use this product as a sensing device for personnel protection. •• When using sensing devices for personnel protection, use products that meet the laws and standards for personnel protection that apply in each region or country, such as OSHA, ANSI and IEC. User’s Manual available for download Load Connect to 0 V (Blue) of HG-TC101-P Connect to 0 V (Blue) of HG-TC101 (Grey) Analog current output Load (Shield) Analog ground (Note) AGND Internal circuit Analog input device Users’ circuit * 1 Non-voltage contact or PNP open collector transistor or +4 V to +V DC: Effective 0 to +0.6 V DC or open: Ineffective Note: Use shielded wire for the analog output. Refer to the instruction manual for details. The instruction manual can be downloaded from our website. Cautions for laser beams ••This product is classified as a Class 1 Laser Product in IEC / JIS / GB standards and in FDA* regulations. Do not look at the laser beam through optical system such as a lens. ••The warning label and the proof label are attached to the product. Handle the product according to the instruction given on the label. * This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). The HG-T series User’s Manual is available for download from our website. 15 HG-T Refer to the instruction manual for details. The instruction manual can be downloaded from our website. PRECAUTIONS FOR PROPER USE Sensor head Mounting •• The light emitting and receiving surfaces of the sensor head must be free of water, oil, fin­gerprints, and other substances that refract light as well as dust, grit, and other objects that intercept light. •• Do not allow ambient light such as sunlight to directly hit the light receiving section of the sensor head. In particular, if precision is required, use this product by mounting a douser (or similar material) on the sensor head. •• A serial number is marked on each opposite surface of the light emitting and receiving surfaces of the sensor head. Use a pair of emitter and receiver that have the same serial number. ••For the installation of sensor heads, use M3 screws and tighten to the torque of 0.5 N·m. M3 screws are not provided with the product. Beam axis M3 screw (Purchase separately.) Serial number (Marked on the opposite surface of light emitting or receiving surfaces) Controller Mounting Mounting 1. Insert the rear of the mounting part into the DIN rail. 2. While pressing down on the rear of the mounting part, insert the front of the mounting part into the DIN rail. 2. Press 1. Insert 35 mm 1.378 in width DIN rail Removal method 1. Press forward 1. Grasp the product and push forward. 2. Lift the front to remove. Mounting Removal method 1. Grasp the controller, and while pressing on the lock release lever on the connector of the sensor head connection cable, pull toward you to disconnect. 1. Insert Lock release lever 1. Pull out Note: If you attempt to disconnect the cable by pulling it without pressing the lock release lever, cable wire breakage and connector damage may occur. Connection •• Always shut off the power before connecting a slave unit to or disconnecting a slave unit from the master unit. Risk of controller damage if you attempt connection with the power on. •• Insert the male connector firmly into the female connector. Risk of controller damage if not completely connected. ••When connecting slave units to a master unit, connect only NPN output types, or only PNP output types. Dissimilar output types cannot be connected together. 16 ••If the HG‑TC□ controller is used together with the HG‑SC□ controller for contact-type digital displacement sensor HG-S series, make sure to use the HG-SC□ controller manufactured in and after February, 2019. Furthermore, connect the slaves units of the same series to the side closer to the master unit and the slave units of the other series to the far side. Common Wiring ••The product is designed to fulfill the specifications when combined with the HG-T□ sensor head and HG-TC□ controller. If the product is used in combination with other products, it not only fails to meet the specifications but also generates a malfunction in some cases. ••For the controller DC power supply, only use a power supply that is isolated by means of an isolation transformer or otherwise. ••Risk of short-circuiting and damage to the controller or power supply if a transformer such as an auto transformer is used. Risk of short-circuiting and damage to the controller or power supply if incorrectly mounted or connected. •• Make sure that the power supply is off while performing wiring or expansion work. •• After you have completed wiring work, check the wiring carefully before switching on the power. •• Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction. •• Verify that the supply voltage variation is within the rating. •• If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground. •• Make sure that stress by forcible bend or pulling is not applied directly to the sensor cable joint. Others 2. Lift Attaching the sensor head connection cable 1. Insert the sensor head connection cable into the connector for the sensor head connection cable on the controller. ••To connect units, the units must be mounted on a DIN rail. Attach end plates MS-DIN-E (optional) so as to enclose the connected units at the ends. •• This device has been developed / produced for industrial use only. •• Do not use this product outside the range of the specifications. Risk of an accident and product damage. There is also a risk of a noticeable reduction of service life. •• Do not use during the initial transient time after the power supply is switched on. •• To ensure performance, use the product at least 30 minutes (warm-up time) after the power is turned ON. •• This product (controller and sensor head receiver) uses an EEPROM. The EEPROM has a service life of one million setting operations. •• This product is suitable for indoor use only. •• Avoid dust, dirt, and steam. •• Take care that the product does not come in direct contact with organic solvents such as thinner. •• Take care that the product does not come in direct contact with strong acid or alkaline. •• Take care that the product does not come in direct contact with oil or grease. •• Do not use in an environment containing inflammable or explosive gases. •• Performance may not be satisfactory in a strong electromagnetic field. •• The sensor head is watertight, but the connector is not dustproof, waterproofing, or corrosion-resistant due to its structural reasons, so measurements cannot be taken under the water or in the rain. Pay attention to the environment where the product is used. •• This product is a precision device. Do not drop or otherwise subject to shock. Risk of product damage. •• Never attempt to disassemble, repair, or modify the product. HG-T DIMENSIONS (Unit: mm in) The CAD data can be downloaded from our website. HG-T1010 Sensor head (Standard type) ø3.8 ø0.150 cable, 0.2 m 0.656 ft long (with connector) Emitter 60 2.362 (37.75 1.486) 54 2.126 3 0.118 (5.8 0.228) 19.5 0.768 15 0.591 or more 3.5 0.138 2-M2 × 0.4 0.016 depth 3 0.118 Side view lens mounting hole ø3.8 ø0.150 cable, 0.2 m 0.656 ft long (with connector) (25.8 1.016) 6.2 0.244 Side view lens mounting hole 8 0.315 15 0.591 26.7 or more 1.051 ø9.5 ø0.374 26.7 15 0.591 1.051 or more 2-M2 × 0.4 0.016 depth 3 0.118 2-ø3.5 ø0.138 mounting holes R or 30 R mo 1. re 181 60 2.362 15 0.591 or more 19.5 0.768 81 1.1 0 R re R3 r mo o ø9.5 ø0.374 6.2 0.244 Beam axis Beam axis Beam axis adjustment indicator (Orange / Green) 15.8 0.622 3 0.118 15.8 0.622 3 0.118 54 2.126 (37.75 1.486) 8 0.315 30 Laser radiation indicator (Green) 1.181 Judgment output indicator 24 3 (Orange / Green) 0.118 0.945 (14 0.551) (4 0.157) (4 0.157) 3.5 0.138 30 1.181 24 0.945 2-ø3.5 ø0.138 mounting holes Receiver HG-T1110 Sensor head (Slim type) 1 18 R1. R30r more o ø3.8 ø0.150 cable, 0.2 m 0.656 ft long (with connector) ø3.8 ø0.150 cable, 0.2 m 0.656 ft long (with connector) Emitter 15 0.591 26.7 or more 1.051 ø9.5 ø0.374 26.7 15 0.591 1.051 or more 3 0.118 19.5 0.768 3.5 0.138 19.5 0.768 8.1 0.319 8 0.315 60 2.362 6.2 0.244 54 2.126 Beam axis Beam axis 2-ø3.3 ø0.130 mounting holes 15 0.591 or more 3.5 0.138 4 0.157 (4 0.157) 32.8 1.291 15.8 0.622 54 2.126 (37.75 1.486) 3 0.118 81 1.1 0 R re R3 r mo o ø9.5 ø0.374 15 0.591 or more 60 2.362 3 0.118 8 0.315 20 0.787 3 14 0.118 0.551 15.8 0.622 30 1.181 24 0.945 2-ø3.5 ø0.138 mounting holes Laser radiation indicator (Green) Judgment output indicator (Orange / Green) Receiver HG-TSV10 Side view attachment (Optional) Assembly dimensions R2 2- The diagram shows the attachment mounted on the receiver of the standard type sensor head HG-T1010. Can be installed in either direction. Two M2 (length 4 mm 0.157 in) screws with washers are attached. Beam axis 4 0.157 (7 0.276) 24 0.945 3 0.118 8 0.315 Beam axis 3 0.118 7.6 (38 1.496) 30 1.181 54 2.126 60 2.362 12.8 0.504 8 0.315 29.6 1.165 15.8 0.622 7.6 0.299 15.8 0.622 29.6 1.165 8 0.315 (12.8 0.504) 1.5 0.059 (38 1.496) 30 1.181 3 0.118 2-ø2.3 ø0.091 mounting holes 60 2.362 54 2.126 0.7 0.028 1.3 0.051 3.48 0.137 HG-T1010 mounting surface 2R2 R0 .0 79 7.6 0.299 3.8 0.150 8 0.315 8 0.315 79 .0 R0 29.6 1.165 25 0.984 20 0.787 4 0.157 (7 0.276) 3 0.118 24 0.945 Notes: 1) The attachment cannot be installed to the slim type sensor head HG-T1110. 2) Be sure to confirm proper detection using actual equipment in advance when using the attachment. 17 HG-T DIMENSIONS (Unit: mm in) HG-TC101-P Controller (Master unit) Output 1 indicator (Orange) Output 2 indicator (Orange) LEFT key UP key RIGHT key Output 3 indicator (Orange) Input indicator (White) Preset indicator (Green) Preset key 21.1 0.831 3 20 0.787 0.118 or more 80 3.150 20 0.787 R or 30 mo R1 re .18 1 23 0.906 8 1.1 0 R re R3 r mo o 6.5 0.256 14.3 0.563 ø5.5 ø0.217 cable, 2 m 6.562 ft long (9-core composite cable) 15 0.591 or more 13.8 0.543 5.9 0.232 3 73.6 21.5 2.898 0.846 Sensor head connection cable (optional) 58.5 2.303 Suitable for 35 mm 1.378 in width DIN rail 36.5 1.437 1 HG-TC111 EXIT key 3.2 0.126 43.1 1.697 19.9 0.783 DOWN key ENTER key HG-TC111-P Controller (Slave unit) Output 1 indicator (Orange) Output 2 indicator (Orange) LEFT key UP key RIGHT key Output 3 indicator (Orange) Input indicator (White) Preset indicator (Green) Preset key 21.1 0.831 5.6 0.220 3.2 0.126 EXIT key ENTER key 3 20 0.787 0.118 or more 80 3.150 20 0.787 13.8 0.543 5.9 0.232 8 1.1 0 R re R3 r mo o 6.5 0.256 14.3 0.563 ø5.5 ø0.217 cable, 2 m 6.562 ft long (7-core composite cable) 15 0.591 or more 43.1 1.697 19.9 0.783 DOWN key 23 0.906 R or 30 mo R1 re .18 1 HG-TC101 The CAD data can be downloaded from our website. 3 36.5 1.437 1 73.6 21.5 2.898 0.846 Sensor head connection cable (optional) 58.5 2.303 Suitable for 35 mm 1.378 in width DIN rail HG-TC113 Controller (Slave unit) Output 1 indicator (Orange) Output 2 indicator (Orange) LEFT key Output 3 indicator (Orange) Input indicator (White) Preset indicator (Green) Preset key 21.1 0.831 19.9 0.783 5.9 0.232 43.1 1.697 EXIT key 80 3.150 ENTER key 2.6 0.102 13.8 0.543 23 0.906 73.6 21.5 2.898 0.846 Sensor head connection cable (optional) 1 18 3.2 0.126 DOWN key 15 0.591 or more 8 1.1 0 R re R3 r mo o 6.5 0.256 14.3 0.563 5.6 0.220 UP key RIGHT key 3 0.118 36.5 1.437 Suitable for 35 mm 1.378 in width DIN rail HG-T DIMENSIONS (Unit: mm in) The CAD data can be downloaded from our website. CN-HT-C□ Sensor head connection cable A 24.7 0.972 26.5 1.043 M8 connector for connection of sensor head 15 0.591 B CN-HT-C2 10 0.394 60 2.362 ø5.6 ø0.220 cable Model No. Connector for connection of controller CN-HT-C5 2-ø4.8 ø0.189 cables CN-HT-C10 CN-HT-C20 SC-HG1-USB USB communication unit SC-HG1-CEF ERROR indicator (Red) Port 2 ERR. indicator (Yellow) 21.2 0.835 80 3.150 Suitable for 35 mm 1.378 in width DIN rail SC-HG1-C CC-Link communication unit 6.4 0.252 L_ERR (communication error) indicator (Red) 35.7 1.406 SD (data transmission) indicator (Green) 21.1 0.831 Communication setting switches 55.9 2.201 Upper communication connector 21 0.827 Communication setting switches 30.6 1.205 21.1 0.831 58.5 2.303 61.1 2.406 42.9 1.689 3 0.118 61.1 2.406 43 1.693 3 0.118 11.55 0.455 21.5 9.55 0.846 0.376 Setting switch cover Communication setting switch cover Communication setting switch cover 38 1.496 Suitable for 35 mm 1.378 in width DIN rail 38 1.496 Termination resistor switching jumper pin (Note) 11.55 0.455 21 0.827 Lower communication error indicator (Red) 18 14.8 0.709 0.583 18 14.3 0.709 0.563 ERR. indicator (Red) 80 3.150 18 0.709 14 0.551 10 0.394 6 0.236 Upper communication error indicator (Red) 6.9 0.272 25.35 0.998 14 0.551 10 0.394 6 0.236 Power indicator (Green) 9.55 0.376 RS-485 communication unit Communication indicator (Green) RD (data reception) indicator (Green) 21.5 0.846 SC-HG1-485 Power indicator (Green) L_RUN (communication operation) indicator (Green) Station No. / Network No. setting switch 11.55 0.455 36.5 1.437 80 3.150 SD indicator (Green) 6.4 0.252 21.5 0.846 Port 2 LINK indicator (Green) Suitable for 35 mm 1.378 in width DIN rail Upper communication connector RUN indicator (Green) 10.6 0.417 21.1 0.831 43.1 1.697 Port 1 ERR. indicator (Yellow) 58 2.283 3 0.118 5.6 0.220 Power indicator (Green) Port1 LINK indicator (Green) 3 0.118 21.1 0.831 D LINK indicator (Green) 6.4 0.252 13.3 0.524 25.35 0.998 22.65 0.892 42.9 1.689 36.9 1.453 14.6 0.575 26.3 1.035 500 19.685 500 19.685 1,000 39.370 1,000 39.370 18 0.709 14 0.551 10 0.394 6 0.236 STS1 indicator (Green) STS2 indicator (Red) 16.6 16.6 Upper communication 0.654 0.654 connector 8.5 0.335 7 0.276 Power indicator (Green) B CC-Link IE Field communication unit RD indicator (Green) USB port (Mini-B) A 2,000 78.740 5,000 196.850 10,000 393.701 20,000 787.402 25.35 0.998 23 0.906 80 3.150 21.5 0.846 9.55 0.376 38 1.496 Suitable for 35 mm 1.378 in width DIN rail Note: The termination resistor switching jumper pin is not attached to the product at the factory. Attach the termination resistor switching jumper pin to the unit at the terminating end. Make sure that the termination resistor switching jumper pin have been removed from all units except the one at the terminating end. 19 HG-T DIMENSIONS (Unit: mm in) MS-DIN-E 2.75 0.108 3 0.118 15 0.591 The CAD data can be downloaded from our website. End plates M3 (length 18 mm 0.709 in) pan head screw 60 2.362 3 0.118 5.6 M3 square nut 0.220 24.7 0.972 1.6 0.063 32 1.260 4 0.157 Suitable for 35 mm 1.378 in width DIN rail Material: Polycarbonate Disclaimer The applications described in the catalog are all intended for examples only. The purchase of our products described in the catalog shall not be regarded as granting of a license to use our products in the described applications. We do NOT warrant that we have obtained some intellectual properties, such as patent rights, with respect to such applications, or that the described applications may not infringe any intellectual property rights, such as patent rights, of a third party. Please contact .......... Electromechanical Control Business Division 1006, Oaza Kadoma, Kadoma-shi, Osaka 571-8506, Japan industrial.panasonic.com/ac/e/ ©Panasonic Corporation 2019 No.CE-HGT-10 February, 2019 Specifications are subject to change without notice.
HG-TC111 价格&库存

很抱歉,暂时无法提供与“HG-TC111”相匹配的价格&库存,您可以联系我们找货

免费人工找货