0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
HL-AC1P

HL-AC1P

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    DIGITAL CONTROLLER PNP

  • 数据手册
  • 价格&库存
HL-AC1P 数据手册
1111 FIBER SENSORS Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES Related Information ■■General terms and conditions.............. F-3 ■■Glossary of terms / General precautions...... P.1587 / P.1595 ■■Selection guide............................. P.1021~ ■■About laser beam.......................... P.1593~ LASER SENSORS PHOTOELECTRIC SENSORS Conforming to FDA regulations (HL-T□F only) MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS panasonic.net/id/pidsx/global Ultra-compact sensor head A high-functionality intelligent controller Ultra-compact sensor head Resolution of 4 µm 0.157 mil The ultra-compact size and yet the high level of performance. These sensors save space. A high resolution of 4 μm 0.157 mil (at an average 64 cycles) allows high-precision positioning and size judgment. HL-T1001A(F) HL-T1005A(F) HL-T1010A(F) Emitter 15mm 0.591 in 20 mm 0.787 in 15 mm 0.591 in 42 mm 1.654 in 20 mm 0.7487 in 19 mm 0.748 in 20 mm 0.787 in 15 mm 0.591 in Other Products HL-T1 LD LA Distinguishing size of electronic components Emitter 34 mm 1.339 in 15 mm 0.591 in Selection Guide Laser Displacement Magnetic Displacement Contact Displacement Collimated Beam Sensors Metal-sheet Double-feed Detection Digital Panel Controller This product is classified as a Class 1 Laser Product in IEC / JIS standards and a Class II Laser Product in FDA regulations. Do not look at the laser beam through optical system such as a lens. Receiver 25 mm 0.984 in 20 mm 0.787 in Receiver BASIC PERFORMANCE Long sensing range Long sensing range of 500 mm 19.685 in [HL-T1005A(F), HL-T1010A(F)] and 2 m 6.562 ft [HL-T1001A(F)] are available. High-precision judgment even from minute differences in light intensity The sensors are sensitive Distinguishing opacity of glass to minute differences in light intensity, so that they can judge even the opacity of glass. In addition, the amount of light received can be displayed as a percentage to allow you to determine permeation rates. Minimum sensing object diameter ø8 µm ø0.315 mil HL-T1001A(F) The laser with a beam diameter of ø1 mm ø0.039 in can sense extremely small objects with dimensions in micrometers such as bonding wires. Adoption of a Class 1 laser The adoption of a Class 1 laser (IEC / JIS) eliminates the need for safety countermeasures, so that these sensors can be used in photoelectric sensor applications with confidence. Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES APPLICATIONS Checking the positioning of chip components 1112 FIBER SENSORS Detecting defective lead frame seating Sensing wafer position in wafer cassette LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS FUNCTIONS Fully equipped with convenient functionality Analog output is switchable between current / voltage A wide range of convenient features has been incorporated into the unit’s compact body: standard received light setting / auto scaling setting / measurement processing (various timer and hold functions) / differentiation / monitor focus function. These features make the unit useful for a wide variety of applications. The analog output can be switched between either of two different outputs; current (4 to 20 mA) / voltage (±4 V). With the monitor focus function, the output can be adjusted over the range from –5 V to +5 V, or from 0 V to +5 V, facilitating connectivity with a variety of output devices. Positioning teaching The actual value measured at the time when teaching is performed is utilized as the threshold value. Best suited for high-precision positioning. 2-point teaching In this teaching method, an intermediate level between the first and the second teaching levels is utilized as the threshold value. Minute differences, such as changes as small as the thickness of a sheet of paper between the sensing objects, can be detected when this teaching method is utilized. Automatic teaching With this teaching method, a series of periodic arbitrarily measurements are taken automatically and an intermediate value, between the maximum and minimum values obtained by this measurement, is utilized as the threshold value. The threshold value is therefore set in relation to the sensing object. Best suited for applications in which teaching must be performed without stopping the current flow of operations. The linear output is fully adjustable over the following range (current: 4 to 20 mA / voltage: ±4 V). The usage of the monitor focus function together with selectable current / voltage switching for the linear output allows for compatibility with a variety of output devices. (Examples) STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES MACHINE VISION SYSTEMS –4 UV CURING SYSTEMS +5 +1 0 5.0 0.197 Sensor display value (mm in) In the event that 5 mm 0.197 in: +1 V 0 mm 0 in: +5 V +5 +1 0 5.0 0.197 Sensor display value (mm in) The linear output must be set by determining output values (maximum; current: 0 to 23.5 mA / voltage: ±5.5 V) at two different points, for the arbitrary display value. MAINTENANCE Self-check for laser diode deterioration The intelligent controller performs self-checking for laser diode deterioration. If the controller detects significant deterioration (end of diode life), an error will be displayed on the main digital display panel. This function enables users to prepare in advance for potential laser diode malfunctions. MEASUREMENT SENSORS FA COMPONENTS In the event that 5 mm 0.197 in: +5 V 0 mm 0 in: +1 V Linear output voltage (V) indicator WIRE-SAVING SYSTEMS 0 5.0 0.197 Sensor display value (mm in) Detection resolution can be easily confirmed The current resolution can be easily confirmed by setting the controller to indicate resolution display mode. By displaying the resolution, the marginal increment can be easily determined for the threshold value setting, helping to accurately determine whether sensing can be performed. Resolution SIMPLE WIRE-SAVING UNITS ENERGY MANAGEMENT SOLUTIONS +4 Linear output voltage (V) 3 types of teaching functions are available: positioning teaching / 2-point teaching / automatic teaching, thus enabling a variety of applications to be accommodated for many different types of production sites. Monitor focus function Linear output voltage (V) 3 types of teaching functions are now available SENSOR OPTIONS Error display Selection Guide Laser Displacement Magnetic Displacement Contact Displacement Collimated Beam Sensors Metal-sheet Double-feed Detection Digital Panel Controller Other Products HL-T1 LD LA 1113 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES OPERABILITY OPTIONS Superior operability has been achieved Calculations for 2 sensors are possible All settings can be easily performed by using the four-way keys and viewing the digital displays. The calculation unit (optional) just needs to be connected between the two controllers to enable calculations (addition and subtraction) to be carried out for two sensors. No digital panel controller is needed either. MICRO PHOTOELECTRIC SENSORS Large dual digital display After power up, the measured value (red) and the threshold value (yellow) are displayed (letter height 7 mm 0.276 in) AREA SENSORS Sheet width measurement Judgment output indicators SAFETY LIGHT CURTAINS / SAFETY COMPONENTS HIGH (Orange) / PASS (Green) / LOW (Yellow) 3-color display PRESSURE / FLOW SENSORS Calculation unit HL-AC1-CL INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Laser Displacement Magnetic Displacement Contact Displacement Collimated Beam Sensors Metal-sheet Double-feed Detection Digital Panel Controller Other Products HL-T1 LD LA Sensor heads Type Appearance Beam diameter ø1 mm ø0.039 in type MEASUREMENT SENSORS ORDER GUIDE Sensing width 5 mm 0.197 in type WIRE-SAVING SYSTEMS Easy operation with four-way keys Sensing width 10 mm 0.394 in type SIMPLE WIRE-SAVING UNITS Sensing range 2 m 6.562 ft 500 mm 19.685 in 500 mm 19.685 in Sensing width Min. sensing object ø1 mm ø0.039 in ø1 to ø2.5 mm ø0.039 to ø0.098 in at 500 to 2,000 mm 19.685 to 78.740 in sensing range ø8 µm ø0.315 mil opaque object ø50 µm ø1.969 mil opaque object at 500 to 2,000 mm 19.685 to 78.740 in sensing range 5 mm 0.197 in 10 mm 0.394 in Conforming standards / regulations Model No. IEC / JIS HL-T1001A FDA / IEC / JIS HL-T1001F IEC / JIS HL-T1005A FDA / IEC / JIS HL-T1005F IEC / JIS HL-T1010A FDA / IEC / JIS HL-T1010F ø0.05 mm ø0.002 in opaque object ø0.1 mm ø0.004 in opaque object Note: The model No. with “P” shown on the label affixed to the product is the emitter, “D” shown on the label is the receiver. Accessories • MS-HLT1-1 Sensor mounting bracket for HL-T1001A(F) / HL-T1005A(F) (Note) Two M3 (length 20 mm 0.787 in) screws with washers are attached. Note: 2 sets are required to mount the emitter/receiver. • MS-LA3-1 Sensor mounting bracket for HL-T1010A(F) (Note) Two M3 (length 25 mm 0.984 in) screws with washers are attached. • CN-HLT1-1 (Sensor head to controller connection cable) Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES 1114 ORDER GUIDE FIBER SENSORS LASER SENSORS Controllers Type Appearance Model No. PHOTOELECTRIC SENSORS Output NPN output MICRO PHOTOELECTRIC SENSORS HL-AC1 AREA SENSORS NPN open-collector transistor (Judgment output) Current/voltage output (Linear output) SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PNP output PRESSURE / FLOW SENSORS HL-AC1P INDUCTIVE PROXIMITY SENSORS PNP open-collector transistor (Judgment output) Current/voltage output (Linear output) PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS Calculation unit WIRE-SAVING SYSTEMS Appearance Model No. MEASUREMENT SENSORS STATIC CONTROL DEVICES HL-AC1-CL LASER MARKERS PLC HUMAN MACHINE INTERFACES OPTIONS Designation Side-view attachment ENERGY MANAGEMENT SOLUTIONS Model No. Description HL-T1SV1 For HL-T1001A(F) / T1005A(F) (1 pc.) HL-T1SV2 For HL-T1010A(F) (1 pc.) Side-view attachment • HL-T1SV1 • HL-T1SV2 MACHINE VISION SYSTEMS The beam axis can be bent to a right angle making universal mounting possible. UV CURING SYSTEMS Controller MS-HLAC1-1 Use when mounting the controller with screws. mounting bracket HL-T1CCJ4 Length: 4 m 13.123 ft Net weight: 162 g approx. HL-T1CCJ8 Length: 8 m 26.247 ft Net weight: 330 g approx. Extension cable Extension cable for use between the controller and its cable linking it with the sensor head. Cabtyre cable with connectors on both ends Cable outer diameter: ø5.2 mm ø0.205 in Connector outer diameter: ø15.5 mm ø0.610 in max. FA COMPONENTS Selection Guide Mounted on both sides Mounted on one side only Controller mounting bracket • MS-HLAC1-1 Laser Displacement Magnetic Displacement Contact Displacement Collimated Beam Sensors Metal-sheet Double-feed Detection Digital Panel Controller Other Products HL-T1 LD LA Extension cable • HL-T1CCJ4 • HL-T1CCJ8 1115 Sensor heads Type Beam diameter ø1 mm ø0.039 in type SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES Item ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS FDA conformed type HL-T1001F Other Products HL-T1 LD LA 500 mm 19.685 in 10 mm 0.394 in Min. sensing object ø50 µm ø1.969 mil opaque object ø0.05 mm ø0.002 in opaque object ø0.1 mm ø0.004 in opaque object Repeatability (During the state in which light is half blocked) 4 µm 0.157 mil (Note 2) – 4 µm 0.157 mil (Note 2) Linear output resolution (Note 3) 4 µm 0.157 mil (Note 2, 4) – 4 µm 0.157 mil (Note 2) Emission indicator Green LED (lights up during laser emission) Interference prevention function Two units of sensors can be mounted close together. (When the controller interference prevention function is used) Pollution degree Ambient temperature 3 (industrial environment) 0 to +50 °C +32 to +122 °F (No dew condensation allowed), Storage: –25 to +70 °C –13 to +158 °F Ambient humidity Ambient illuminance Voltage withstandability 35 to 85 % RH, Storage: 35 to 85 % RH Incandescent light: 10,000 ℓx or less at the light-receiving face 1,000 V AC for one min. between all supply terminals connected together and enclosure Insulation resistance 100 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each Shock resistance IEC / JIS conformed type FDA conformed type Material 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each Red semiconductor laser Class 1 (IEC / JIS) Red semiconductor laser Class 1 (IEC / JIS) modulated, max. output: 0.2 mW, peak emission wavelength: 650 nm 0.026 mil modulated, max. output: 0.35 mW, peak emission wavelength: 650 nm 0.026 mil Red semiconductor laser Class II (FDA) Red semiconductor laser Class II (FDA) modulated, max. output: 0.2 mW, peak emission wavelength: 650 nm 0.026 mil (IEC / JIS: Class 1) modulated, max. output: 0.35 mW, peak emission wavelength: 650 nm 0.026 mil (IEC / JIS: Class 1) Enclosure: Polyetherimide, Case cover: Polycarbonate, Front cover: Glass 0.09mm2 3-core shielded cable with connector, 0.5 m 1.640 ft long Cable extension Extension up to total 10 m 32.808 ft is possible, with the optional cable. Emitter: 15 g approx., Receiver: 15 g approx. Emitter: 30 g approx., Receiver: 20 g approx. MS-HLT1-1(Sensor head mounting bracket): One set of two brackets for both the emitter and the receiver CN-HLT1-1(Sensor head to controller connection cable): 1 cable Laser beam alignment sticker: 2 pcs. Label set (FDA conformed type only): 1 set MS-LA3-1 (Sensor head mounting bracket): One set of two brackets for both the emitter and the receiver CN-HLT1-1 (Sensor head to controller connection cable): 1 cable Laser beam alignment sticker: 2 pcs. Label set (FDA conformed type only): 1 set Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. 2) In case of an average sampling rate of 64 times. 3) Value calculated with the linear output allowance factor (±3 σ) when connected to the controller included in the calculation of the detection width. 4) This value was obtained by converting the range of linear output fluctuation (±3 σ) into a sensing width, assuming that the smallest sensing object blocks the beam at the approximate center of the beam diameter of ø1 mm ø0.039 in. Calculation unit Model No. Item CE marking directive compliance HL-AC1-CL EMC Directive, RoHS Directive Connected controller HL-AC1, HL-AC1P Current consumption 12 mA or less (supplied from the controller) Connecting method Connection indicator Environmental resistance Digital Panel Controller HL-AC1, HL-AC1P ø8 µm ø0.315 mil opaque object Accessories Contact Displacement HL-T1010F 5 mm 0.197 in Net weight Collimated Beam Sensors Metal-sheet Double-feed Detection HL-T1005F EMC Directive, RoHS Directive ø1 to ø2.5 mm ø0.039 to ø0.098 in UV CURING SYSTEMS Magnetic Displacement HL-T1010A ø1 mm ø0.039 in Cable Laser Displacement Sensing width 10 mm 0.394 in type HL-T1005A Sensing width MACHINE VISION SYSTEMS Selection Guide Sensing width 5 mm 0.197 in type 0 to 500 mm 0 to 19.685 in 500 to 2,000 mm 19.685 to 78.74 in Sensing range Emitting element HUMAN MACHINE INTERFACES HL-T1001A Applicable controller LASER MARKERS PLC IEC / JIS conformed type CE marking directive compliance Environmental resistance AREA SENSORS Model No. PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS HL-T1 SERIES SPECIFICATIONS FIBER SENSORS LASER SENSORS Ultra-compact Laser Collimated Beam Sensor Ambient temperature Ambient humidity Voltage withstandablity Connector Orange LED (lights up when connected to the controller) 0 to +50 °C +32 to +122 °F (No dew condensation allowed), Storage: –15 to +60 °C +5 to +140 °F 35 to 85 % RH, Storage: 35 to 85 % RH 1,000 V AC for one min. between all supply terminals connected together and enclosure Insulation resistance 100 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 150 Hz frequency, 0.7 mm 0.028 in double amplitude in X, Y and Z directions for 80 min. Shock resistance 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each Material Enclosure: ABS, Indicator part: Acrylic Weight Net weight: 50 g approx. Note: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES 1116 SPECIFICATIONS FIBER SENSORS LASER SENSORS Controllers Type Item NPN output HL-AC1 Model No. CE marking directive compliance HL-AC1P HL-T1001A/T1001F, HL-T1005A/T1005F, HL-T1010A/T1010F 150 μs Temperature characteristics PRESSURE / FLOW SENSORS ±0.2 % F.S./°C (Note 3) INDUCTIVE PROXIMITY SENSORS 1 / 2 / 4 / 8 / 16 / 32 / 64 / 128 / 256 / 512 / 1,024 / 2,048 / 4,096 NPN open-collector transistor • Maximum sink current: 50 mA • Applied voltage: 30 V DC or less (between judgment output and 0 V) • Residual voltage: 1.2 V or less (at 50 mA sink current) PNP open-collector transistor • Maximum source current: 50 mA • Applied voltage: 30 V DC or less (between judgment output and +V) • Residual voltage: 2 V or less (at 50 mA source current) SENSOR OPTIONS DC-12 or DC-13 Number of outputs HIGH / PASS / LOW 3 values output SIMPLE WIRE-SAVING UNITS HIGH: ON when measured value > HIGH threshold value PASS: ON when HIGH threshold value ≥ measured value ≥ LOW threshold value LOW: ON when LOW threshold value > measured value WIRE-SAVING SYSTEMS Short-circuit protection Incorporated Laser OFF input 0 V connection: Laser emission halt Open: Laser emission • Applied voltage: 30 V DC or less (leak current: 0.1 mA or less) +V connection: Laser emission halt Open: Laser emission • Applied voltage: 30 V DC or less (leak current: 0.1 mA or less) Zero reset input 0 V connection: Zero reset operates Open: Zero reset ineffective • Applied voltage: 30 V DC or less (leak current: 0.1 mA or less) +V connection: Zero reset operates Open: Zero reset ineffective • Applied voltage: 30 V DC or less (leak current: 0.1 mA or less) Timing input 0 V connection: Effective Open: Ineffective • Applied voltage: 30 V DC or less (leak current: 0.1 mA or less) +V connection: Effective Open: Ineffective • Applied voltage: 30 V DC or less (leak current: 0.1 mA or less) Reset input 0 V connection: Effective Open: Ineffective • Applied voltage: 30 V DC or less (leak current: 0.1 mA or less) +V connection: Effective Open: Ineffective • Applied voltage: 30 V DC or less (leak current: 0.1 mA or less) Laser emitting (LD ON) Indicators PARTICULAR USE SENSORS Utilization category Output operation Judgment outputs Green LED (lights up during laser emission) HIGH: Orange LED (lights up when measured value > HIGH threshold value) PASS: Green LED (lights up when HIGH threshold value ≥ measured value ≥ LOW threshold value) LOW: Yellow LED (lights up when LOW threshold value > measured value) Enable (ENABLE) Green LED (lights up during normal operation) Zero reset (ZERO) Green LED (lights up when the zero reset function is enabled) Main digital display Sub-digital display Main functions Environmental resistance AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS Current / voltage output switchable (Note 2) • During current output: 4 to 20 mA/F.S., Maximum load resistance: 300 Ω • During voltage output: ±4 V/F.S., Output impedance 100 Ω (In the monitor focus function, it can also be set at ±5 V, 0 to 5 V, etc.) Settable average sampling rate (Note 4) Judgment outputs (HIGH, PASS, LOW) MICRO PHOTOELECTRIC SENSORS 12 to 24 V DC ±10 %   Ripple P-P 10 % or less / 190 mA or less (when connected to the sensor head) Measuring cycle Linear output PHOTOELECTRIC SENSORS EMC Directive, RoHS Directive Applicable sensor head Supply voltage / Current consumption PNP output Pollution degree Ambient temperature Ambient humidity Voltage withstandability 5 digit red LED display 5 digit yellow LED display • Measured value display • Setting value, light amount value resolution display • Standard received light setting • Automatic scaling • Scaling RUN mode: Either the resolution or laser beam reception amount will be displayed. THR mode: The threshold value will be displayed., Reverse mode: The display orientation will be reversed. • Display reverse • ECO display • Display digits limitation • Sample hold • Peak hold • Bottom hold • Peak to peak hold • Self peak hold • Self bottom hold • Zero reset • Initial reset • ON-delay timer • OFF-delay timer • One-shot timer • Differentiation • Sensitivity selection • Threshold value direct setting • Positioning teaching • 2-point teaching • Automatic teaching • Hysteresis width variability • Monitor focus • Non-measuring time setting • (A – B) calculation (Note 5) • (A + B) calculation (Note 5) • Mutual interference prevention (Note 5) • Laser deterioration detection • Key lock • Zero reset memory 3 (industrial environment) 0 to +50 °C +32 to +122 °F (No dew condensation allowed), Storage: –25 to +65 °C –13 to +149 °F 10 to 150 Hz frequency, 0.7 mm 0.028 in double amplitude in X, Y and Z directions for 80 min. I/O cable extension Weight PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS Selection Guide Laser Displacement Magnetic Displacement Contact Displacement Collimated Beam Sensors Metal-sheet Double-feed Detection Digital Panel Controller Other Products 35 to 85 % RH, Storage: 35 to 85 % RH 1,000 V AC for one min. between all supply terminals connected together and enclosure Vibration resistance I/O cable LASER MARKERS RUN mode: Either the measured value (mm) or the hold value will be displayed. Reverse mode: The display orientation will be reversed. 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure Material STATIC CONTROL DEVICES UV CURING SYSTEMS Insulation resistance Shock resistance MEASUREMENT SENSORS 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each Enclosure: Polybutylene terephthalate, Transparent cover: Polycarbonate 0.09 mm2 10-core composite cable, 2 m 6.562 ft long Extension up to total 10 m 32.808 ft is possible, with 0.09 mm2 or more, cable. (Note 6) Net weight: 140 g approx. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. 2) Switching between current and voltage is accomplished by a switch on the bottom of the controller. 3) This is a typical value when the sensor head is connected. 4) The judgment output and linear output and linear output response time is calculated by (Measuring cycle) × (Set average sampling rate + 1). 5) The calculation unit is necessary. 6) If the extension cable is longer than 10 m 32.808 ft, then it will not qualify for CE marking. HL-T1 LD LA 1117 HL-AC1 D 50 mA max. (Gray) LOW judgment output ZD2 Tr3 Main circuit ZD3 (Blue) GND (0 V) SENSOR OPTIONS 100Ω WIRE-SAVING SYSTEMS UV CURING SYSTEMS *1 (Orange / Violet) Zero reset input *1 *1 (Red) Reset input *1 (Orange / Violet) Zero reset input (Red) Reset input Current output 4 to 20 mA (Black) Linear output Current output: Load 300 Ω or less Voltage output: 10 kΩ or more 100Ω Symbols … D: Reverse supply polarity protection diode ZD1, ZD2, ZD3: Surge absorption zener diode Tr1, Tr2, Tr3: PNP output transistor Non-voltage contact or PNP open-collector transistor or or • LD-OFF input, Timing input, Zero reset input, Reset input Low (0 to 1.5 V): Effective High (+V or open): Ineffective • LD-OFF input, Timing input, Zero reset input, Reset input Low (0 V or open): Ineffective High [ +V to ( +V –1.5 V)]: Effective SENSING CHARACTERISTICS (TYPICAL) HL-T1005A  HL-T1005F HL-T1001A  HL-T1001F Correlation between transverse deviation and output voltage Correlation between transverse deviation and output voltage HL-T1 LD 4 Vertical direction Horizontal direction 2 The graph depicts the correlation between transverse deviation and output voltage when the full-scale setting ranges from 0 V (light beam is interrupted) to 5 V (light beam is fully incident), using the Monitor Focus function. 0 4 2 0 2 4 0.157 0.079 0.079 0.157 (Up) Left Center Right (Down) Deviation ℓ (mm in) Digital Panel Controller Other Products 6 Correlation between interrupted beam width and output voltage 8 Linear output voltage (V) LA 6 8 Horizontal direction Vertical direction 500 mm 19.685 in 500 mm 19.685 in Receiver Receiver Emitter Emitter ℓ ℓ Vertical direction 4 2 Horizontal direction The graph depicts the correlation between transverse deviation and output voltage when the full-scale setting ranges from 0 V (light beam is interrupted) to 5 V (light beam is fully incident), using the Monitor Focus function. 0 10 5 0 5 10 0.394 0.197 0.197 0.394 (Up) Left Center Right (Down) Deviation ℓ (mm in) 6 8 Horizontal direction Vertical direction 500 mm 19.685 in 500 mm 19.685 in Receiver Receiver Emitter Emitter ℓ ℓ 4 Vertical direction Horizontal direction 2 The graph depicts the correlation between transverse deviation and output voltage when the full-scale setting ranges from 0 V (light beam is interrupted) to 5 V (light beam is fully incident), using the Monitor Focus function. 0 10 5 0 5 10 0.394 0.197 0.197 0.394 (Up) Left Center Right (Down) Deviation ℓ (mm in) HL-T1010A  HL-T1010F Correlation between transverse deviation and output voltage Correlation between interrupted beam width and output voltage 8 Horizontal direction Vertical direction 2 m 6.562 ft 2 m 6.562 ft Receiver Receiver Emitter Emitter ℓ ℓ Linear output voltage (V) Contact Displacement Collimated Beam Sensors Metal-sheet Double-feed Detection Users’ circuit * 1 250 mm 9.843 in Sensing object + Receiver ℓ Emitter Linear output voltage (V) Magnetic Displacement Current output: 300 Ω or less Voltage Load Voltage output: (Shield) Linear GND output ±4 V 10 kΩ or more Internal circuit Users’ circuit Non-voltage contact or NPN open-collector transistor Linear output voltage (V) Laser Displacement 12 to 24 V DC ±10 % (Gray) LOW judgment output Load (Blue) GND (0 V) ZD3 *1 (Violet) Timing input 8 Selection Guide – *1 *1 * 1 FA COMPONENTS MACHINE VISION SYSTEMS (Green) PASS judgment output Load 50 mA max. ZD2 6 – 500 mm 19.685 in 4 2 0 –10 –5 0 5 –0.394 –0.197 0.197 Screeing edge position ℓ (mm in) 10 0.394 250 mm 9.843 in Sensing object ℓ Receiver + Emitter Linear output voltage (V) ENERGY MANAGEMENT SOLUTIONS Tr3 Symbols … D: Reverse supply polarity protection diode ZD1, ZD2, ZD3: Surge absorption zener diode Tr1, Tr2, Tr3: NPN output transistor PLC HUMAN MACHINE INTERFACES ZD1 (Violet) Timing input *1 Voltage output ±4 V (Shield) Linear GND 50 mA max. (White) HIGH judgment output Load 50 mA max. + (Pink) LD-OFF input (Pink) LD-OFF input Internal circuit 12 to 24 V DC ±10 % 50 mA max. Current output 4 to 20 mA (Black) Linear output SIMPLE WIRE-SAVING UNITS – Tr2 Main circuit ZD1 Tr2 Tr1 D Load 50 mA max. Load + (Green) PASS judgment output PARTICULAR USE SENSORS LASER MARKERS (Brown) +V (White) HIGH Load judgment output Tr1 SAFETY LIGHT CURTAINS / SAFETY COMPONENTS STATIC CONTROL DEVICES Color code Color code AREA SENSORS MEASUREMENT SENSORS PNP output type (Brown) +V MICRO PHOTOELECTRIC SENSORS INDUCTIVE PROXIMITY SENSORS HL-AC1P NPN output type PHOTOELECTRIC SENSORS PRESSURE / FLOW SENSORS HL-T1 SERIES I/O CIRCUIT DIAGRAMS FIBER SENSORS LASER SENSORS Ultra-compact Laser Collimated Beam Sensor 6 – 500 mm 19.685 in 4 2 0 –10 –5 0 5 –0.394 –0.197 0.197 Screeing edge position ℓ (mm in) 10 0.394 Ultra-compact Laser Collimated Beam Sensor PRECAUTIONS FOR PROPER USE • Never use this product as a sensing device for personnel protection. • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. Function Zero reset function • This product is classified as a Class 1 Laser Product in IEC / JIS regulations and a Class II Laser Product in FDA regulations. Do not look at the laser beam through optical system such as a lens. • The following label is attached to the product. Handle the product according to the instruction given on the warning label. The English warning label based on FDA regulations is pasted on the FDA conformed type. Safety standards for laser beam products • A laser beam can harm human being’s eyes, skin, etc., because of its high energy density. IEC has classified laser products according to the degree of hazard and the stipulated safety requirements. The HL-T1 series is classified as Class 1 laser. Classification by IEC 60825-1 Description Lasers that are safe under reasonably foreseeable conditions of operation, including the use of optical instruments for intrabeam viewing. Safe use of laser products • For the purpose of preventing users from suffering injuries by laser products, IEC 60825-1 “Safety of laser products”. Kindly check the standards before use. (Refer to p.1593~ for information about laser beam.) Standard received light setting Scaling function Details The following tasks can be done by executing zero reset. • The display value can be set at “0”. • The linear output when the display reads “0” is made the center output value of the 2 points set by monitor focus. (In the default state, the current output is 12 mA and the voltage output is 0 V.) The auto scaling function selects whether to display the laser beam reception amount in the main-digital display in “mm” units or in “%” units, and determines whether the amount of laser beam received or the amount of laser beam interrupted is displayed. With the set standard laser beam reception amount as the reference value, the current laser beam reception amount (laser beam interrupted amount) is scaled automatically and is displayed as well as being output. This function registers and stores the current laser beam reception amount in memory as the standard laser beam reception amount. The laser beam reception amount during full laser beam entry becomes the 100 % laser beam reception amount’s full scale (F.S.). If this function is used, the display and the linear output are set on the full scale (F.S.) automatically. It can also be used to correct the laser beam reception amount when there is a change in the laser beam reception amount due to dirt, etc. on the front glass. The scaling function is a function that changes the display value to the desired amount with respect to the setting value. At the desired distance, the display value can be input and changed. Hysteresis width setting function This function sets the hysteresis to the desired value. Monitor focus function With this function, the linear output range and inclination, etc. with respect to the display value can be specified. Setting is done by determining the 2 output values with respect to the desired display values. Differential function This function makes the amount of change in the measured value an output value. Use this function when measuring if you are paying attention to changes in measured values, as when counting the number of workpieces, etc. Display reverse function The digital display’s direction can be selected. The forward direction or the reverse direction to match the direction of installation on the equipment can be selected. ECO display function This function makes the display dark and saves electric power. Display digits limitation function This determines the number of display digits in the main-digital and sub-digital displays. If the number of digits is limited, the digits are turned off beginning with the lowest order digit. Zero reset memory function This selects whether or not to save the zero reset level in memory when the power is turned OFF. If you desire to reproduce the zero reset level from the previous operating session when you turn the power ON again, then enable this function. If this function is enabled, the zero reset level data are written into the EEPROM each time. Key lock function FIBER SENSORS LASER SENSORS Functions Auto scaling function Class 1 1118 Refer to p.1595 for general precautions and p.1593~ for information about laser beam. • This catalog is a guide to select a suitable product. Be sure to read instruction manual attached to the product prior to its use. Classification HL-T1 SERIES The controller’s key input can be disabled. Once the key input is disabled, the controller will not accept any key inputs until the key lock is released. Use this function to avoid changing the setting by mistake. Connection • This product is made to satisfy the specifications when the sensor head is combined with the controller. In any other combination, not only may it not satisfy the specifications, but could be the cause of breakdown. So by all means, use it so that there is a combination of the sensor head and the controller. PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Laser Displacement Magnetic Displacement Contact Displacement Collimated Beam Sensors Metal-sheet Double-feed Detection Digital Panel Controller Other Products HL-T1 LD LA 1119 FIBER SENSORS LASER SENSORS Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES PRECAUTIONS FOR PROPER USE Functional description ② PHOTOELECTRIC SENSORS ① Refer to p.1595 for general precautions and p.1593~ for information about laser beam. ⑥ ⑤ ③ ⑫ ⑨ ⑪ MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS ④ INDUCTIVE PROXIMITY SENSORS Description PARTICULAR USE SENSORS Laser emitting indicator (LD ON) (Green LED) SENSOR OPTIONS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS ⑬ Function Lights up when the sensor head is emitting laser beam. When in the RUN mode, it displays the measured value (mm/%). During measurement hold, it displays the hold value (mm/%). In Reverse mode, the top and bottom are displayed in reverse. Sub-digital display (5 digit yellow LED) When in the RUN mode, it displays the threshold value, voltage / current value, light reception amount or resolution. When in the THR mode, it displays the respective threshold values. In reverse mode, the top and bottom are displayed in reverse. Enable indicator (ENABLE) (Green LED) Lights up when operation is normal. Goes off when operation is abnormal (if the sensor head is not connected when the power is turned on). Zero reset indicator (ZERO) (Green LED) Lights up when the zero reset function is enabled. Mode selection switch The following 3 modes can be selected. • RUN mode: Measuring mode • THR mode: The threshold values are set in this mode. • FUN mode: Each of the settings are set in this mode. Threshold value select switch When in the THR / RUN mode, this switches the set threshold value (HIGH / LOW). UP key Selection Guide Laser Displacement Magnetic Displacement Contact Displacement Collimated Beam Sensors Metal-sheet Double-feed Detection Other Products • RUN mode: Timing input • THR mode: Changes the threshold value (forward direction) • FUN mode: Changes the function setting value (forward direction) DOWN key • RUN mode: Press for 3 sec. or more: Standard light reception amount setting input • THR mode: Changes the threshold value (reverse direction) • FUN mode: Changes the function setting value (reverse direction) RIGHT key • RUN mode: Changes the contents of the sub-digital display (forward direction) • THR mode: Changes the threshold value digit (forward direction) • FUN mode: Sets function selection (forward direction) LEFT key • RUN mode: Changes the contents of the sub-digital display (reverse direction) • THR mode: Changes the threshold value digit (reverse direction) • FUN mode: Sets function selection (reverse direction) ENT key Digital Panel Controller LA ⑩ Main digital display (5 digit red LED) ENERGY MANAGEMENT SOLUTIONS LD ⑦ Judgment output indicators HIGH: Orange LED (lights up when measured value HIGH threshold value) (HIGH / PASS / LOW) PASS: Green LED (lights up when HIGH threshold value measured value LOW threshold value) (Orange / Green / Yellow LED) LOW: Yellow LED (lights up when LOW threshold value measured value) SIMPLE WIRE-SAVING UNITS HL-T1 ⑧ • RUN mode: Pressing for 1 sec. or more, executes zero reset.Pressing together with the RIGHT key for 3 sec. or more, cancels zero reset. • THR mode: When threshold value is blinking, the threshold value is set. When the threshold value lights up, teaching is executed. • FUN mode: When the set value is blinking, the value is set. When the setting is being initialized, pressing for a long time executes initialization. Others • This product outputs the judgment of the laser light analog quantity. Since there is variation in the light intensity between the center and the edges of the detection area, and the emitter side and the receiver side, the “display value” does not equal “the actual dimensions”, so caution is necessary. Use the displayed dimensional value as a criterion. • If the object being measured has a mirror surface or is a transparent body, it may be impossible to measure it accurately, so please exercise caution. • Absolutely do not attempt to disassemble this product. Ultra-compact Laser Collimated Beam Sensor DIMENSIONS (Unit: mm in) HL-T1 SERIES The CAD data can be downloaded from our website. HL-T1001A(F) HL-T1005A(F) ø2.6 ø0.102 cable, 0.5 m 1.640 ft long (Gray) Sensor head 2-ø3.2 ø0.126 2.8 0.110 34 1.339 16 0.630 0.2 0.008 (1.5) (0.059) 2-ø3.2 ø0.126 ø2.6 ø0.102 cable, 0.5 m 1.640 ft long (Black) Manufactured by J.S.T. Mfg. Co., Ltd. 2.8 XARR-04VF* 0.110 19 0.748 5 0.197 15 9 0.354 0.591 Manufactured by J.S.T. Mfg. Co., Ltd. XARR-04VF* 1120 (36.5) (1.437) (6.9) (0.272) Certification / identification label (Note 1) (50 µm 1.969 mil polyester film) 15 9 0.591 0.354 * The sensor heads that were produced before January 2006 use the connector shown below. Please note that the new connector and previous connector are incompatible. Manufactured by Molex 51029-0410 Light beam shielding plate (Note 1) Sensor head 2-ø3.2 ø0.126 ø2.6 ø0.102 cable, 0.5 m 1.640 ft long (Gray) 14 20 0.551 0.787 Manufactured by J.S.T. Mfg. Co., Ltd. (36.5) XARR-04VF* (1.437) 22 0.866 (1.5) (0.059) 10 0.394 25 0.984 2-ø3.2 ø0.126 ø2.6 ø0.102 cable, 0.5 m 1.640 ft long (Black) 2.8 Manufactured by 0.110 J.S.T. Mfg. Co., Ltd. XARR-04VF* * The sensor heads that were produced before January 2006 use the connector shown below. Please note that the new connector and previous connector are incompatible. MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS (10) (0.394) Manufactured by Molex 51029-0410 Light beam shielding plate (Note) MACHINE VISION SYSTEMS UV CURING SYSTEMS Beam axis 20 0.787 20 0.787 Emitter Receiver Selection Guide Note: IEC / JIS conforming products do not contain light beam shielding plate, or certification/identification label. HL-AC1 HL-AC1P Controller Laser Displacement HL-AC1-CL Calculation unit (Optional) Mounting drawing with a mounting bracket MS-HLAC1-1 (Optional) Connector for calculation unit connection (on each side) (3.6) (0.142) PRESSURE / FLOW SENSORS HUMAN MACHINE INTERFACES 14 20 0.787 0.551 Certification / identification label (Note) (50 μm 1.969 mil polyester film) Emission indicator (Green) SAFETY LIGHT CURTAINS / SAFETY COMPONENTS WIRE-SAVING SYSTEMS HL-T1010A HL-T1010F 0.2 0.008 (6.9)(0.272) AREA SENSORS SIMPLE WIRE-SAVING UNITS Receiver Notes: 1) IEC / JIS conforming products do not contain light beam shielding plate, or certification / identification label. 2) The receiver of HL-T1001A(F) does not incorporate a slit. 42 1.654 MICRO PHOTOELECTRIC SENSORS SENSOR OPTIONS 15 0.591 Emitter 2.8 0.110 PHOTOELECTRIC SENSORS PARTICULAR USE SENSORS Beam axis (Note 2) 15 0.591 LASER SENSORS INDUCTIVE PROXIMITY SENSORS (10) (0.394) Emission indicator (Green) FIBER SENSORS 32.2 1.268 30 1.181 64.3 2.531 Linking connector 24.9 0.980 Magnetic Displacement Contact Displacement Collimated Beam Sensors Metal-sheet Double-feed Detection Digital Panel Controller Other Products Connection indicator (Orange) 4.3 0.169 34.3 1.350 13.2 0.520 3.9 0.154 22.4 16 0.882 0.630 13 36.8 0.512 1.449 2-ø3.2 ø0.126 150 5.906 approx. ø5.1 ø0.201 cable 3.4 0.134 15.8 0.622 ø5.2 ø0.205 cable, 2 m 6.562 ft long Suitable for 35 mm 1.378 in width DIN rail 5.4 0.213 3.4 0.134 32.2 1.268 16.1 0.634 Connector for sensor head connection 22.4 16 0.882 0.630 5.4 0.213 12 0.472 8 0.315 HL-T1 15.1 0.594 57 2.244 54.9 2.161 LD LA 30 26 1.181 1.024 5 3.4 0.197 0.134 36.7 1.445 Suitable for 35 mm 1.378 in width DIN rail 1121 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS Ultra-compact Laser Collimated Beam Sensor DIMENSIONS (Unit: mm in) MS-HLT1-1 AREA SENSORS 1.1 0.043 5 0.197 PARTICULAR USE SENSORS SIMPLE WIRE-SAVING UNITS STATIC CONTROL DEVICES LASER MARKERS t 1.2 t 0.047 17 0.669 12.5 (34.6) 14.5 0.492 3.2 0.126 (1.362) 0.571 10 0.394 9 0.354 7 0.276 3.2 0.126 5 5 0.197 0.197 3.4 0.134 17 0.669 24.5 0.965 MS-LA3-1 1 Assembly dimensions 2 20 0.787 14 0.551 2-ø3.2 ø0.126 13 6 0.236 0.512 14 0.551 MACHINE VISION SYSTEMS 14 0.551 3 0.118 2-ø3.2 ø0.126 UV CURING SYSTEMS 6 0.236 2.6 0.102 3.4 0.134 3.4 0.134 2.6 0.102 Mounting drawing with HL-T1010A’s receiver 2-ø3.2 ø0.126 2-M3 × 0.5 0.020 t 1.6 t 0.063 10 0.394 2.6 0.102 Laser Displacement Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated) Magnetic Displacement Two M3 (length 25 mm 0.984 in) screws with washers are attached. MS-HLAC1-1 23 0.906 33 1.229 Controller mounting bracket (Optional) 34.8 1.370 22 0.866 16 0.630 Other Products 2.5 0.098 7.3 0.287 3 0.118 3.4 0.134 26.8 1.055 16 0.630 14 0.551 10 0.394 3.4 0.134 2.6 0.102 23 0.906 13 0.512 Contact Displacement Digital Panel Controller 3 0.118 3.4 0.134 3 0.118 10 0.394 t 1.6 t 0.063 16 0.630 2.6 0.102 14 0.551 (45.1) 23 (1.776) 0.906 3.4 0.134 13 0.512 6 0.236 23 0.906 20 0.787 14 0.551 2.6 0.102 3.4 0.134 14 0.551 23 0.906 LA 13.1 0.516 t 1.2 t 0.047 Sensor head mounting bracket for HL-T1010A(F) [Accessory for HL-T1010A(F)] FA COMPONENTS LD 3.4 0.134 1.6 0.063 9 0.354 5 0.197 Two M3 (length 20 mm 0.787 in) screws with washers are attached. ENERGY MANAGEMENT SOLUTIONS HL-T1 3.4 0.134 3 0.118 17 9.5 0.669 0.374 Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated) HUMAN MACHINE INTERFACES Collimated Beam Sensors Metal-sheet Double-feed Detection 1.6 0.063 9 0.354 2-ø3.2 ø0.126 1.1 0.043 5 0.197 ø3.2 ø0.126 PLC Selection Guide Mounting drawing with HL-T1005A’s receiver t 1.6 t 0.063 13.1 0.516 9 0.354 3.4 0.134 17 0.669 6 0.236 2-M3 × 0.5 0.020 5 0.197 5 0.197 5 0.197 INDUCTIVE PROXIMITY SENSORS Assembly dimensions 15 0.591 9 0.354 9 0.354 3.4 0.134 PRESSURE / FLOW SENSORS MEASUREMENT SENSORS 2 7 5 0.276 0.197 3.2 0.126 SAFETY LIGHT CURTAINS / SAFETY COMPONENTS WIRE-SAVING SYSTEMS The CAD data can be downloaded from our website. Sensor head mounting bracket for HL-T1001A(F) / HL-T1005A(F) [Accessory for HL-T1001A(F) / HL-T1005A(F)] 3.4 0.134 1.1 9 ø3.2 ø0.126 0.043 0.354 1 MICRO PHOTOELECTRIC SENSORS SENSOR OPTIONS HL-T1 SERIES CN-HLT1-1 20 0.787 t 1.6 t 0.063 Sensor head to controller connection cable (Accessory for sensor head) +200 2-ø3.2 ø0.126 46 1.811 3 0.118 ø15 ø0.591 Manufactured by Hirose Electric Co.,Ltd. RP17-13P-12PC Black ø2.6 ø0.102 × 2 Manufactured by J.S.T. Mfg. Co., Ltd. XAP-04V-1* 3 0.118 5.4 0.213 5.4 0.213 32.2 27.2 1.268 1.071 1,500 0 59.055 +7.874 0 Gray 5.3 0.209 * The sensor heads that were produced before January 2006 use the connector shown below. Please note that the new connector and previous connector are incompatible. 27.2 1.071 3.4 0.134 t 1.0 t 0.039 Manufactured by Molex 51030-0430 Ultra-compact Laser Collimated Beam Sensor DIMENSIONS (Unit: mm in) HL-T1 SERIES 1122 The CAD data can be downloaded from our website. HL-T1SV1 Side-view attachment for HL-T1001A(F) / HL-T1005A(F) (Optional) Assembly dimensions Mounting drawing with HL-T1005A’s receiver 2.7 0.106 2-ø2.2 ø0.087 Beam axis Beam axis 7.5 0.295 15 0.591 2.2 0.087 15 0.591 19 0.748 SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS HL-T1SV2 Side-view attachment for HL-T1010A(F) (Optional) Assembly dimensions Mounting drawing with HL-T1010A’s receiver 2.8 0.110 21 0.827 STATIC CONTROL DEVICES HUMAN MACHINE INTERFACES 25 0.984 Beam axis ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS 20 0.787 11 0.433 21 0.827 MEASUREMENT SENSORS PLC (46) (1.811) Beam axis WIRE-SAVING SYSTEMS LASER MARKERS 20 0.787 20 0.787 2.2 0.087 PRESSURE / FLOW SENSORS PARTICULAR USE SENSORS 12.5 0.492 Two M2 (length 6 mm 0.236 in) screws with washers are attached. 20 15.6 0.787 0.614 MICRO PHOTOELECTRIC SENSORS INDUCTIVE PROXIMITY SENSORS Material: Polyetherimide (Enclosure), Glass (Front cover) 2-ø2.2 ø0.087 PHOTOELECTRIC SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS (34) (1.339) 15 0.591 15 10.6 0.591 0.417 LASER SENSORS AREA SENSORS 15 0.591 15 0.591 FIBER SENSORS MACHINE VISION SYSTEMS 21 0.827 UV CURING SYSTEMS Material: Polyetherimide (Enclosure), Glass (Front cover) Two M2 (length 6 mm 0.236 in) screws with washers are attached. Selection Guide Laser Displacement Magnetic Displacement Contact Displacement Collimated Beam Sensors Metal-sheet Double-feed Detection Digital Panel Controller Other Products HL-T1 LD LA
HL-AC1P 价格&库存

很抱歉,暂时无法提供与“HL-AC1P”相匹配的价格&库存,您可以联系我们找货

免费人工找货