To Be Discontinued
Last time buy: September 30, 2018
RoHS compliant
Relay for control panel of
1c 15A, and 2c 10A
HL RELAYS
FEATURES
TYPICAL APPLICATIONS
1. Compact high-capacity control relay
In the same external dimensions as an
HC relay, this compact power relay
enables high-capacity control:
15 A for 1 Form C, 10 A for 2 Form C.
2. Designed for high reliability
High operational reliability is achieved by
solder-less construction, in which all
connections between lead wires and the
contact springs and terminal plate are
welded.
3. Various types provided in rich
lineup. LED indicator and diode type
is also available.
4. The terminals are compatible with
#187 series tab terminals.
5. Sockets and terminal sockets are
available.
1. Factory automation equipment and
automotive devices
2. Control panels, power supply
equipment, molding equipment,
machine tools, welding equipment,
agricultural equipment, etc.
3. Office equipment, automatic
vending machines,
telecommunications equipment,
disaster prevention equipment,
copiers, measuring devices, medical
equipment, amusement devices, etc.
4. All types of household appliance
ORDERING INFORMATION
HL
F
Contact arrangement
1: 1 Form C
2: 2 Form C
Terminal arrangement
H:
Plug-in type
L:
Plug-in type with LED indication
HP: PC board type
PL: PC board type with LED indication
HTM: TM type
Nominal coil voltage
AC 6, 12, 24, 48, 100 (100/110), 120 (110/120),
200 (200/220), 240 (220/240) V
DC 6, 12, 24, 48, 100 (100/110) V
Surge absorber
*D: with diode
Contact material
F: AgSnO2 type
Notes: 1. Certified by C-UL, CSA and TÜV
Please inquire about TV approved products.
2. *Diode type is available. (DC coil Plug-in type with LED indication only)
3. The LED indication color is green for the DC coil and red for the AC coil.
–1–
ASCTB114E 201709-T
To Be Discontinued
Last time buy: September 30, 2018
HL
TYPES
1. Plug-in type
Nominal coil
voltage
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
2. Plug-in type (with LED indication)
1 Form C
Part No.
HL1-H-AC6V-F
HL1-H-AC12V-F
HL1-H-AC24V-F
HL1-H-AC48V-F
HL1-H-AC100V-F
HL1-H-AC120V-F
HL1-H-AC200V-F
HL1-H-AC240V-F
HL1-H-DC6V-F
HL1-H-DC12V-F
HL1-H-DC24V-F
HL1-H-DC48V-F
HL1-H-DC100V-F
2 Form C
Part No.
HL2-H-AC6V-F
HL2-H-AC12V-F
HL2-H-AC24V-F
HL2-H-AC48V-F
HL2-H-AC100V-F
HL2-H-AC120V-F
HL2-H-AC200V-F
HL2-H-AC240V-F
HL2-H-DC6V-F
HL2-H-DC12V-F
HL2-H-DC24V-F
HL2-H-DC48V-F
HL2-H-DC100V-F
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HL1-L-DC6V-D-F
HL1-L-DC12V-D-F
HL1-L-DC24V-D-F
HL1-L-DC48V-D-F
HL1-L-DC100V-D-F
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HL1-L-AC6V-F
HL1-L-AC12V-F
HL1-L-AC24V-F
HL1-L-AC48V-F
HL1-L-AC100V-F
HL1-L-AC120V-F
HL1-L-AC200V-F
HL1-L-AC240V-F
HL1-L-DC6V-F
HL1-L-DC12V-F
HL1-L-DC24V-F
HL1-L-DC48V-F
HL1-L-DC100V-F
2 Form C
Part No.
HL2-L-AC6V-F
HL2-L-AC12V-F
HL2-L-AC24V-F
HL2-L-AC48V-F
HL2-L-AC100V-F
HL2-L-AC120V-F
HL2-L-AC200V-F
HL2-L-AC240V-F
HL2-L-DC6V-F
HL2-L-DC12V-F
HL2-L-DC24V-F
HL2-L-DC48V-F
HL2-L-DC100V-F
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
3. Plug-in type (with LED indication and diode)
Nominal coil
voltage
Nominal coil
voltage
2 Form C
Part No.
HL2-L-DC6V-D-F
HL2-L-DC12V-D-F
HL2-L-DC24V-D-F
HL2-L-DC48V-D-F
HL2-L-DC100V-D-F
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
4. PC board type
Nominal coil
voltage
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HL1-HP-AC6V-F
HL1-HP-AC12V-F
HL1-HP-AC24V-F
HL1-HP-AC48V-F
HL1-HP-AC100V-F
HL1-HP-AC120V-F
HL1-HP-AC200V-F
HL1-HP-AC240V-F
HL1-HP-DC6V-F
HL1-HP-DC12V-F
HL1-HP-DC24V-F
HL1-HP-DC48V-F
HL1-HP-DC100V-F
2 Form C
Part No.
HL2-HP-AC6V-F
HL2-HP-AC12V-F
HL2-HP-AC24V-F
HL2-HP-AC48V-F
HL2-HP-AC100V-F
HL2-HP-AC120V-F
HL2-HP-AC200V-F
HL2-HP-AC240V-F
HL2-HP-DC6V-F
HL2-HP-DC12V-F
HL2-HP-DC24V-F
HL2-HP-DC48V-F
HL2-HP-DC100V-F
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
5. PC board type (with LED indication)
Nominal coil
voltage
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HL1-PL-AC6V-F
HL1-PL-AC12V-F
HL1-PL-AC24V-F
HL1-PL-AC48V-F
HL1-PL-AC100V-F
HL1-PL-AC120V-F
HL1-PL-AC200V-F
HL1-PL-AC240V-F
HL1-PL-DC6V-F
HL1-PL-DC12V-F
HL1-PL-DC24V-F
HL1-PL-DC48V-F
HL1-PL-DC100V-F
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
6. TM type
2 Form C
Part No.
HL2-PL-AC6V-F
HL2-PL-AC12V-F
HL2-PL-AC24V-F
HL2-PL-AC48V-F
HL2-PL-AC100V-F
HL2-PL-AC120V-F
HL2-PL-AC200V-F
HL2-PL-AC240V-F
HL2-PL-DC6V-F
HL2-PL-DC12V-F
HL2-PL-DC24V-F
HL2-PL-DC48V-F
HL2-PL-DC100V-F
Nominal coil
voltage
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HL1-HTM-AC6V-F
HL1-HTM-AC12V-F
HL1-HTM-AC24V-F
HL1-HTM-AC48V-F
HL1-HTM-AC100V-F
HL1-HTM-AC120V-F
HL1-HTM-AC200V-F
HL1-HTM-AC240V-F
HL1-HTM-DC6V-F
HL1-HTM-DC12V-F
HL1-HTM-DC24V-F
HL1-HTM-DC48V-F
HL1-HTM-DC100V-F
2 Form C
Part No.
HL2-HTM-AC6V-F
HL2-HTM-AC12V-F
HL2-HTM-AC24V-F
HL2-HTM-AC48V-F
HL2-HTM-AC100V-F
HL2-HTM-AC120V-F
HL2-HTM-AC200V-F
HL2-HTM-AC240V-F
HL2-HTM-DC6V-F
HL2-HTM-DC12V-F
HL2-HTM-DC24V-F
HL2-HTM-DC48V-F
HL2-HTM-DC100V-F
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
–2–
ASCTB114E 201709-T
To Be Discontinued
Last time buy: September 30, 2018
HL
RATING
1. Coil data
1) AC coils
Nominal coil
voltage
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
Nominal coil current
(mA)
50Hz
60Hz
224
200
111
56
28
13.4/14.7
12.2/13.5
6.7/7.4
Nominal operating power
(VA)
50Hz
60Hz
100
50
25
12/13.2
10.9/11.9
6/6.6
1.3
1.2
Pick-up voltage
(at 20°C 68°F)
80%V or less of
nominal voltage
(Initial)
Drop-out voltage
(at 20°C 68°F)
30%V or more of
nominal voltage
(Initial)
Inductance (H)
When drop-out
0.078
When operating
0.074
0.312
1.243
4.974
23.75
27.19
85.98
0.295
1.181
4.145
20.63
25.57
81.76
Max. applied
voltage
(at 70°C 158°F)
110%V of
nominal voltage
Notes: 1. The relay operates in a range of 80% to 110% V of the nominal voltage, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the
rated voltage.
In particular, for AC operation, if the applied voltage drops to 80% V or more below the nominal voltage, humming will occur and a large current will flow leading
possibly to coil burnout.
2. The maximum applied voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.
(This value differs depending on the ambient temperature. Please contact us for details.)
2) DC coils (at 20°C 68°F)
Nominal coil
voltage
6V DC
Nominal coil current
(mA)
150
12V DC
24V DC
48V DC
75
37
18.5
100/110V DC
10
Nominal operating
power (W)
0.9
1.0
Coil resistance
(Ω)
40
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Max. applied voltage
(at 70°C 158°F)
160
650
2,600
80%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
10,000
Notes: 1. The nominal operating current is ±10% (20°C 68°F).
2. The coil resistance for DC operation is the value measured when the coil temperature is 20°C 68°F. Compensate ±0.4% for every ±1°C change in temperature.
3. The relay operates in a range of 80% to 110% V of the nominal voltage, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the
nominal voltage.
4. For use with 200 V DC, connect a 10 KΩ (5W) resistor, in series, to the 100 V DC relay.
5. The maximum applied voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.
(This value differs depending on the ambient temperature. Please contact us for details.)
2. Specifications
Characteristics
Contact
Rating
Item
Contact resistance (Initial)
Contact material
Nominal switching capacity*4
Min. switching capacity (Reference value)*1
Insulation resistance (Initial)
Between open contacts
Between contact sets
Between contact and coil
Temperature rise (coil)
Breakdown voltage
(Initial)
Electrical
characteristics
Operate time (at 20°C 68°F)*2
Release time (at 20°C 68°F)*2
Mechanical
characteristics
Expected life
Functional
Destructive
Functional
Vibration resistance
Destructive
Mechanical
Shock resistance
AC load
Electrical
DC load
Conditions
Conditions for operation, transport and storage*3
Max. Operating speed
Unit weight
Specifications
Max. 50 mΩ (By voltage drop 6 V DC 1A)
AgSnO2 type
1 Form C: 15A 125V AC, 10A 250V AC (resistive load)
2 Form C: 10A 250V AC (resistive load)
100mA 5V DC
Min. 100MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
1,000 Vrms for 1min. (Detection current: 10mA)
1,500 Vrms for 1min. (Detection current: 10mA)
2,000 Vrms for 1min. (Detection current: 10mA)
Max. 80°C 176°F (By resistive method, nominal voltage)
DC type/AC type: Max. 25ms
(Nominal coil voltage applied to the coil, excluding contact bounce time.)
DC type/AC type: Max. 25ms
(Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode)
Min. 196 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10μs.)
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 1 mm (Detection time: 10μs.)
10 to 55 Hz at double amplitude of 2 mm
AC type: 5×107 (at 180 times/min.), DC type: 108 (at 180 times/min.)
1 Form C: 15A 125V AC, 10A 250V AC resistive load (cosϕ=1) Life switching cycle: Min. 5×105
2 Form C: 10A 250V AC resistive load (cosϕ=1) Life switching cycle: Min. 3×105
1 Form C: 3A 30V DC resistive load (cosϕ=1) Life switching cycle: Min. 5×105
2 Form C: 3A 30V DC resistive load (cosϕ=1) Life switching cycle: Min. 5×105
Ambient temperature: –50°C to +70°C –58°F to +158°F (Without LED indication);
–50°C to +60°C –58°F to +140°F (With LED indication)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 times/min. (at max. rating)
Approx. 35g 1.23 oz
Notes: If integrating into electrical appliances that will be subject to compliance to the Electrical Appliance and Material Safety Law, please use in an ambient temperature
between –50°C to +40°C –58°F to +104°F (AC type).
*1. This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. For the AC coil types, the operate/release time will differ depending on the phase.
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
*4. When using the socket, be sure to verify the max. continuous current.
–3–
ASCTB114E 201709-T
To Be Discontinued
Last time buy: September 30, 2018
HL
REFERENCE DATA
Switching capacity range (2 Form C)
AC resistive load
15
10
1 DC inductive
load (L/R=7ms)
AC resistive load
Contact current, A
Contact current, A
Switching capacity range (1 Form C)
AC inductive
load (cosϕ=0.4)
DC resistive
load
0.1
10
100
10
1 DC inductive
load (L/R=7ms)
AC inductive
load (cosϕ=0.4)
DC resistive
load
0.1
10
500 1,000
100
500 1,000
Contact voltage, V
Contact voltage, V
With diode type (For DC)
1. DC coil surge voltage waveform
(without diode)
2. DC coil surge voltage waveform
(with diode)
Diode characteristics;
Reverse breakdown voltage: 1,000V,
Forward current: 1A
ON
OFF
ON
OFF
260V
+
+
12V DC
–
To digital
memory
12V DC
–
To digital
memory
breakdown voltage: 1,000 V
(Reverse
(
Forward current: 1 A
DIMENSIONS (mm inch)
The CAD data of the products with a
1. Plug-in type
1 Form C
CAD Data
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
External dimensions
CAD Data
Schematic (Bottom view)
Standard type
27.2
1.071
20.8
.819
With diode type
2
2
3
3
6
6
7
35.4
1.394
LED AC type
0.5
.020
2
3
3
6
6
10
.394
2
3
6
8
(+)
8
LED DC type
2
Compatible with tab terminal
#187 series receptacle.
14.2
.559
8
1.2
.047
6.35
.250
7
(−)
7
7
( )
3.75
.148
4.6
.181
6
.236
7.15
.281
∼
8
( )
∼
7
(−)
8
(+)
General tolerance: ±0.3 ±.012
–4–
ASCTB114E 201709-T
To Be Discontinued
Last time buy: September 30, 2018
HL
2 Form C
External dimensions
CAD Data
20.8
.819
Schematic (Bottom view)
Standard type
27.2
1.071
6.35
.250
3
4
5
6
7
14.2
.559
4
5
6
5
6
8
(−)
7
(+)
8
LED DC type
1
2
1
2
3
4
3
4
5
6
5
6
∼
7
8
( )
(−)
∼
( )
8
(+)
General tolerance: ±0.3 ±.012
2. PC board type
1 Form C
External dimensions
CAD Data
3
7
3.7
.146
4.7
.185
6
.236
7.3
.287
8
2
4
LED AC type
0.5
.020
10
.394
2
1
3
1.2
.047
Compatible with tab terminal
#187 series receptacle.
1
2
7
35.4
1.394
With diode type
1
20.8
.819
Schematic (Bottom view)
Standard type
27.2
1.071
2
3
6
7
35.4
1.394
8
LED AC type
3.5
.138
1.5
.059
1.2
.047
5
.197
LED DC type
2
2
3
3
6
6
0.5
.020
7
∼
7
8
( )
( )
∼
(−)
8
(+)
10
.394
2
3
6
7
8
3.75
.148
4.6
.181
6
.236
7.15
.281
PC board pattern (Bottom view)
4.6
.181
14.2
.559
General tolerance: ±0.3 ±.012
R3
R.118
10
.394
6
.236 R2
R.079
4
.157
14.2
.559
5-2 dia. hole
5-.079 dia.
17.75
.699
8.5
.335
7.15
.281
Tolerance: ±0.1 ±.004
–5–
ASCTB114E 201709-T
To Be Discontinued
Last time buy: September 30, 2018
HL
2 Form C
External dimensions
CAD Data
20.8
.819
Schematic (Bottom view)
Standard type
27.2
1.071
3.5
.138
2
3
4
5
6
7
35.4
1.394
1.5
.059
1
8
LED AC type
1.2
.047
5
.197
0.5
.020
LED DC type
1
2
1
2
3
4
3
4
5
6
5
6
7
∼
7
8
( )
( )
∼
8
(+)
(−)
10
.394
1
2
3
4
5
6
7
8
3.7
.146
4.7
.185
6
.236
7.3
.287
PC board pattern (Bottom view)
8-2 dia. hole
8-.079 dia.
10
.394
14.2
.559
1.25
.049
1.25
.049 2
.079
1.25
.049 2
.079
General tolerance: ±0.3 ±.012
18
.709
13.3
.524
4
.157
R2
R.079
7.3
.287
14.2
.559
R2
R.079
4
4
Tolerance: ±0.1 ±.004
3. TM type
1 Form C
External dimensions
CAD Data
Schematic (Bottom view)
Standard type
43
1.693
20.6
.811
2
2
.079
3
6
7
34.4
1.354
1.2
.047
6.35
.250
Chassis (Panel) cutout
Compatible with tab terminal
#187 series receptacle.
37.6
1.470
Tolerance: ±0.1 ±.004
2
3
6
7
8
Chassis (Panel) cutout
in tandem mounting
23
.906
2-3.2 to 3.5 dia. hole
2-.126 to .138 dia.
0.5
.020
3.6
.142
8
3.75
.148
4.6
.181
6
.236 37.6
7.15 1.480
.281
General tolerance: ±0.3 ±.012
–6–
37.6
1.470
21
21
.827 2 .827
.079
Notes: 1. If connecting to #187 series tab terminals, use AMP Faston
#187 series or #187 tab terminals conforming to UL or CSA
inch-standard dimensions.
2. In mounting, use M3 screws and M3 washers.
3. When mounting TM types, use washers to prevent damage
or distortion to the polycarbonate cover.
4. When tightening fixing screws, the optimum torque range
should be 0.294 to 0.49 N·m, (3 to 5 kgf·cm). Moreover, use
washers to prevent loosening.
ASCTB114E 201709-T
To Be Discontinued
Last time buy: September 30, 2018
HL
2 Form C
External dimensions
CAD Data
Schematic (Bottom view)
Standard type
43
1.693
20.6
.811
2
.079
1
2
3
4
5
6
7
8
34.4
1.354
1.2
.047
6.35
.250
Compatible with tab terminal
#187 series receptacle.
1
2
3
4
5
6
7
8
23
.906
2-3.2 to 3.5 dia. hole
2-.126 to .138 dia.
0.5
.020
3.6
.142
Chassis (Panel) cutout
in tandem mounting
Chassis (Panel) cutout
37.6
1.470
37.6
1.470
21
21
.827 2 .827
.079
Tolerance: ±0.1 ±.004
3.7
.146
4.7
.185
6
37.6
.236 1.480
7.3
.287
Notes: 1. If connecting to #187 series tab terminals, use AMP Faston
#187 series or #187 tab terminals conforming to UL or CSA
inch-standard dimensions.
2. In mounting, use M3 screws and M3 washers.
3. When mounting TM types, use washers to prevent damage
or distortion to the polycarbonate cover.
4. When tightening fixing screws, the optimum torque range
should be 0.294 to 0.49 N·m, (3 to 5 kgf·cm). Moreover, use
washers to prevent loosening.
General tolerance: ±0.3 ±.012
SAFETY STANDARDS
1. Standard type (Plug-in type except with diode, PC board type, TM type)
Contact
arrangement
1 Form C
2 Form C
UL/C-UL (Recognized)
File No.
Contact rating
15A 250V AC
E43028*1
1/3HP 125, 250V AC
10A 30V DC
10A 250V AC
E43028*1
1/3HP 125, 250V AC
10A 30V DC
File No.
—
—
CSA (Certified)
Contact rating
CSA standard
certified by C-UL
CSA standard
certified by C-UL
TV rating (UL/CSA)
File No.
Rating
UL: E43149
NO➝TV-5
CSA: LR26550 NC➝TV-2
etc.
UL: E43149
NO➝TV-4
CSA: LR26550 NC➝TV-2
etc.
File No.
B1305
13461 341
B1305
13461 341
TÜV rating
Rating
15A 125V AC (cosφ =1.0)
10A 250V AC (cosφ =1.0)
10A 30V DC (L/R=0ms)
10A 250V AC (cosφ =1.0)
10A 30V DC (L/R=0ms)
2. Plug-in type (with diode)*2
Contact
arrangement
1 Form C
2 Form C
UL/C-UL (Recognized)
File No.
Contact rating
15A 250V AC
E43028*1
1/3HP 125, 250V AC
10A 30V DC
10A 250V AC
E43028*1
1/3HP 125, 250V AC
10A 30V DC
File No.
—
—
CSA (Certified)
Contact rating
CSA standard
certified by C-UL
CSA standard
certified by C-UL
TV rating (UL/CSA)
File No.
Rating
—
—
File No.
B1305
13461 341
—
—
B1305
13461 341
TÜV rating
Rating
15A 125V AC (cosφ =1.0)
10A 250V AC (cosφ =1.0)
10A 30V DC (L/R=0ms)
10A 250V AC (cosφ =1.0)
10A 30V DC (L/R=0ms)
Note: “*1” indicates the UL/C-UL recognition file number.
“*2” DC coil Plug-in type with LED indication only.
NOTES
1. For cautions for use, please read
“General Application Guidelines”.
–7–
ASCTB114E 201709-T