0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
HL2-PL-AC24V-F

HL2-PL-AC24V-F

  • 厂商:

    NAIS(松下)

  • 封装:

  • 描述:

    RELAY GENERAL PURPOSE

  • 详情介绍
  • 数据手册
  • 价格&库存
HL2-PL-AC24V-F 数据手册
To Be Discontinued Last time buy: September 30, 2018 RoHS compliant Relay for control panel of 1c 15A, and 2c 10A HL RELAYS FEATURES TYPICAL APPLICATIONS 1. Compact high-capacity control relay In the same external dimensions as an HC relay, this compact power relay enables high-capacity control: 15 A for 1 Form C, 10 A for 2 Form C. 2. Designed for high reliability High operational reliability is achieved by solder-less construction, in which all connections between lead wires and the contact springs and terminal plate are welded. 3. Various types provided in rich lineup. LED indicator and diode type is also available. 4. The terminals are compatible with #187 series tab terminals. 5. Sockets and terminal sockets are available. 1. Factory automation equipment and automotive devices 2. Control panels, power supply equipment, molding equipment, machine tools, welding equipment, agricultural equipment, etc. 3. Office equipment, automatic vending machines, telecommunications equipment, disaster prevention equipment, copiers, measuring devices, medical equipment, amusement devices, etc. 4. All types of household appliance ORDERING INFORMATION HL F Contact arrangement 1: 1 Form C 2: 2 Form C Terminal arrangement H: Plug-in type L: Plug-in type with LED indication HP: PC board type PL: PC board type with LED indication HTM: TM type Nominal coil voltage AC 6, 12, 24, 48, 100 (100/110), 120 (110/120), 200 (200/220), 240 (220/240) V DC 6, 12, 24, 48, 100 (100/110) V Surge absorber *D: with diode Contact material F: AgSnO2 type Notes: 1. Certified by C-UL, CSA and TÜV Please inquire about TV approved products. 2. *Diode type is available. (DC coil Plug-in type with LED indication only) 3. The LED indication color is green for the DC coil and red for the AC coil. –1– ASCTB114E 201709-T To Be Discontinued Last time buy: September 30, 2018 HL TYPES 1. Plug-in type Nominal coil voltage 6V AC 12V AC 24V AC 48V AC 100/110V AC 110/120V AC 200/220V AC 220/240V AC 6V DC 12V DC 24V DC 48V DC 100/110V DC 2. Plug-in type (with LED indication) 1 Form C Part No. HL1-H-AC6V-F HL1-H-AC12V-F HL1-H-AC24V-F HL1-H-AC48V-F HL1-H-AC100V-F HL1-H-AC120V-F HL1-H-AC200V-F HL1-H-AC240V-F HL1-H-DC6V-F HL1-H-DC12V-F HL1-H-DC24V-F HL1-H-DC48V-F HL1-H-DC100V-F 2 Form C Part No. HL2-H-AC6V-F HL2-H-AC12V-F HL2-H-AC24V-F HL2-H-AC48V-F HL2-H-AC100V-F HL2-H-AC120V-F HL2-H-AC200V-F HL2-H-AC240V-F HL2-H-DC6V-F HL2-H-DC12V-F HL2-H-DC24V-F HL2-H-DC48V-F HL2-H-DC100V-F Standard packing: Carton: 20 pcs.; Case: 200 pcs. 6V DC 12V DC 24V DC 48V DC 100/110V DC 1 Form C Part No. HL1-L-DC6V-D-F HL1-L-DC12V-D-F HL1-L-DC24V-D-F HL1-L-DC48V-D-F HL1-L-DC100V-D-F 6V AC 12V AC 24V AC 48V AC 100/110V AC 110/120V AC 200/220V AC 220/240V AC 6V DC 12V DC 24V DC 48V DC 100/110V DC 1 Form C Part No. HL1-L-AC6V-F HL1-L-AC12V-F HL1-L-AC24V-F HL1-L-AC48V-F HL1-L-AC100V-F HL1-L-AC120V-F HL1-L-AC200V-F HL1-L-AC240V-F HL1-L-DC6V-F HL1-L-DC12V-F HL1-L-DC24V-F HL1-L-DC48V-F HL1-L-DC100V-F 2 Form C Part No. HL2-L-AC6V-F HL2-L-AC12V-F HL2-L-AC24V-F HL2-L-AC48V-F HL2-L-AC100V-F HL2-L-AC120V-F HL2-L-AC200V-F HL2-L-AC240V-F HL2-L-DC6V-F HL2-L-DC12V-F HL2-L-DC24V-F HL2-L-DC48V-F HL2-L-DC100V-F Standard packing: Carton: 20 pcs.; Case: 200 pcs. 3. Plug-in type (with LED indication and diode) Nominal coil voltage Nominal coil voltage 2 Form C Part No. HL2-L-DC6V-D-F HL2-L-DC12V-D-F HL2-L-DC24V-D-F HL2-L-DC48V-D-F HL2-L-DC100V-D-F Standard packing: Carton: 20 pcs.; Case: 200 pcs. 4. PC board type Nominal coil voltage 6V AC 12V AC 24V AC 48V AC 100/110V AC 110/120V AC 200/220V AC 220/240V AC 6V DC 12V DC 24V DC 48V DC 100/110V DC 1 Form C Part No. HL1-HP-AC6V-F HL1-HP-AC12V-F HL1-HP-AC24V-F HL1-HP-AC48V-F HL1-HP-AC100V-F HL1-HP-AC120V-F HL1-HP-AC200V-F HL1-HP-AC240V-F HL1-HP-DC6V-F HL1-HP-DC12V-F HL1-HP-DC24V-F HL1-HP-DC48V-F HL1-HP-DC100V-F 2 Form C Part No. HL2-HP-AC6V-F HL2-HP-AC12V-F HL2-HP-AC24V-F HL2-HP-AC48V-F HL2-HP-AC100V-F HL2-HP-AC120V-F HL2-HP-AC200V-F HL2-HP-AC240V-F HL2-HP-DC6V-F HL2-HP-DC12V-F HL2-HP-DC24V-F HL2-HP-DC48V-F HL2-HP-DC100V-F Standard packing: Carton: 20 pcs.; Case: 200 pcs. 5. PC board type (with LED indication) Nominal coil voltage 6V AC 12V AC 24V AC 48V AC 100/110V AC 110/120V AC 200/220V AC 220/240V AC 6V DC 12V DC 24V DC 48V DC 100/110V DC 1 Form C Part No. HL1-PL-AC6V-F HL1-PL-AC12V-F HL1-PL-AC24V-F HL1-PL-AC48V-F HL1-PL-AC100V-F HL1-PL-AC120V-F HL1-PL-AC200V-F HL1-PL-AC240V-F HL1-PL-DC6V-F HL1-PL-DC12V-F HL1-PL-DC24V-F HL1-PL-DC48V-F HL1-PL-DC100V-F Standard packing: Carton: 20 pcs.; Case: 200 pcs. 6. TM type 2 Form C Part No. HL2-PL-AC6V-F HL2-PL-AC12V-F HL2-PL-AC24V-F HL2-PL-AC48V-F HL2-PL-AC100V-F HL2-PL-AC120V-F HL2-PL-AC200V-F HL2-PL-AC240V-F HL2-PL-DC6V-F HL2-PL-DC12V-F HL2-PL-DC24V-F HL2-PL-DC48V-F HL2-PL-DC100V-F Nominal coil voltage 6V AC 12V AC 24V AC 48V AC 100/110V AC 110/120V AC 200/220V AC 220/240V AC 6V DC 12V DC 24V DC 48V DC 100/110V DC 1 Form C Part No. HL1-HTM-AC6V-F HL1-HTM-AC12V-F HL1-HTM-AC24V-F HL1-HTM-AC48V-F HL1-HTM-AC100V-F HL1-HTM-AC120V-F HL1-HTM-AC200V-F HL1-HTM-AC240V-F HL1-HTM-DC6V-F HL1-HTM-DC12V-F HL1-HTM-DC24V-F HL1-HTM-DC48V-F HL1-HTM-DC100V-F 2 Form C Part No. HL2-HTM-AC6V-F HL2-HTM-AC12V-F HL2-HTM-AC24V-F HL2-HTM-AC48V-F HL2-HTM-AC100V-F HL2-HTM-AC120V-F HL2-HTM-AC200V-F HL2-HTM-AC240V-F HL2-HTM-DC6V-F HL2-HTM-DC12V-F HL2-HTM-DC24V-F HL2-HTM-DC48V-F HL2-HTM-DC100V-F Standard packing: Carton: 20 pcs.; Case: 200 pcs. –2– ASCTB114E 201709-T To Be Discontinued Last time buy: September 30, 2018 HL RATING 1. Coil data 1) AC coils Nominal coil voltage 6V AC 12V AC 24V AC 48V AC 100/110V AC 110/120V AC 200/220V AC Nominal coil current (mA) 50Hz 60Hz 224 200 111 56 28 13.4/14.7 12.2/13.5 6.7/7.4 Nominal operating power (VA) 50Hz 60Hz 100 50 25 12/13.2 10.9/11.9 6/6.6 1.3 1.2 Pick-up voltage (at 20°C 68°F) 80%V or less of nominal voltage (Initial) Drop-out voltage (at 20°C 68°F) 30%V or more of nominal voltage (Initial) Inductance (H) When drop-out 0.078 When operating 0.074 0.312 1.243 4.974 23.75 27.19 85.98 0.295 1.181 4.145 20.63 25.57 81.76 Max. applied voltage (at 70°C 158°F) 110%V of nominal voltage Notes: 1. The relay operates in a range of 80% to 110% V of the nominal voltage, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the rated voltage. In particular, for AC operation, if the applied voltage drops to 80% V or more below the nominal voltage, humming will occur and a large current will flow leading possibly to coil burnout. 2. The maximum applied voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation. (This value differs depending on the ambient temperature. Please contact us for details.) 2) DC coils (at 20°C 68°F) Nominal coil voltage 6V DC Nominal coil current (mA) 150 12V DC 24V DC 48V DC 75 37 18.5 100/110V DC 10 Nominal operating power (W) 0.9 1.0 Coil resistance (Ω) 40 Pick-up voltage (at 20°C 68°F) Drop-out voltage (at 20°C 68°F) Max. applied voltage (at 70°C 158°F) 160 650 2,600 80%V or less of nominal voltage (Initial) 10%V or more of nominal voltage (Initial) 110%V of nominal voltage 10,000 Notes: 1. The nominal operating current is ±10% (20°C 68°F). 2. The coil resistance for DC operation is the value measured when the coil temperature is 20°C 68°F. Compensate ±0.4% for every ±1°C change in temperature. 3. The relay operates in a range of 80% to 110% V of the nominal voltage, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the nominal voltage. 4. For use with 200 V DC, connect a 10 KΩ (5W) resistor, in series, to the 100 V DC relay. 5. The maximum applied voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation. (This value differs depending on the ambient temperature. Please contact us for details.) 2. Specifications Characteristics Contact Rating Item Contact resistance (Initial) Contact material Nominal switching capacity*4 Min. switching capacity (Reference value)*1 Insulation resistance (Initial) Between open contacts Between contact sets Between contact and coil Temperature rise (coil) Breakdown voltage (Initial) Electrical characteristics Operate time (at 20°C 68°F)*2 Release time (at 20°C 68°F)*2 Mechanical characteristics Expected life Functional Destructive Functional Vibration resistance Destructive Mechanical Shock resistance AC load Electrical DC load Conditions Conditions for operation, transport and storage*3 Max. Operating speed Unit weight Specifications Max. 50 mΩ (By voltage drop 6 V DC 1A) AgSnO2 type 1 Form C: 15A 125V AC, 10A 250V AC (resistive load) 2 Form C: 10A 250V AC (resistive load) 100mA 5V DC Min. 100MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section. 1,000 Vrms for 1min. (Detection current: 10mA) 1,500 Vrms for 1min. (Detection current: 10mA) 2,000 Vrms for 1min. (Detection current: 10mA) Max. 80°C 176°F (By resistive method, nominal voltage) DC type/AC type: Max. 25ms (Nominal coil voltage applied to the coil, excluding contact bounce time.) DC type/AC type: Max. 25ms (Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode) Min. 196 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10μs.) Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.) 10 to 55 Hz at double amplitude of 1 mm (Detection time: 10μs.) 10 to 55 Hz at double amplitude of 2 mm AC type: 5×107 (at 180 times/min.), DC type: 108 (at 180 times/min.) 1 Form C: 15A 125V AC, 10A 250V AC resistive load (cosϕ=1) Life switching cycle: Min. 5×105 2 Form C: 10A 250V AC resistive load (cosϕ=1) Life switching cycle: Min. 3×105 1 Form C: 3A 30V DC resistive load (cosϕ=1) Life switching cycle: Min. 5×105 2 Form C: 3A 30V DC resistive load (cosϕ=1) Life switching cycle: Min. 5×105 Ambient temperature: –50°C to +70°C –58°F to +158°F (Without LED indication); –50°C to +60°C –58°F to +140°F (With LED indication) Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) 20 times/min. (at max. rating) Approx. 35g 1.23 oz Notes: If integrating into electrical appliances that will be subject to compliance to the Electrical Appliance and Material Safety Law, please use in an ambient temperature between –50°C to +40°C –58°F to +104°F (AC type). *1. This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the actual load. *2. For the AC coil types, the operate/release time will differ depending on the phase. *3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage conditions in NOTES. *4. When using the socket, be sure to verify the max. continuous current. –3– ASCTB114E 201709-T To Be Discontinued Last time buy: September 30, 2018 HL REFERENCE DATA Switching capacity range (2 Form C) AC resistive load 15 10 1 DC inductive load (L/R=7ms) AC resistive load Contact current, A Contact current, A Switching capacity range (1 Form C) AC inductive load (cosϕ=0.4) DC resistive load 0.1 10 100 10 1 DC inductive load (L/R=7ms) AC inductive load (cosϕ=0.4) DC resistive load 0.1 10 500 1,000 100 500 1,000 Contact voltage, V Contact voltage, V With diode type (For DC) 1. DC coil surge voltage waveform (without diode) 2. DC coil surge voltage waveform (with diode) Diode characteristics; Reverse breakdown voltage: 1,000V, Forward current: 1A ON OFF ON OFF 260V + + 12V DC – To digital memory 12V DC – To digital memory breakdown voltage: 1,000 V (Reverse ( Forward current: 1 A DIMENSIONS (mm inch) The CAD data of the products with a 1. Plug-in type 1 Form C CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/ External dimensions CAD Data Schematic (Bottom view) Standard type 27.2 1.071 20.8 .819 With diode type 2 2 3 3 6 6 7 35.4 1.394 LED AC type 0.5 .020 2 3 3 6 6 10 .394 2 3 6 8 (+) 8 LED DC type 2 Compatible with tab terminal #187 series receptacle. 14.2 .559 8 1.2 .047 6.35 .250 7 (−) 7 7 ( ) 3.75 .148 4.6 .181 6 .236 7.15 .281 ∼ 8 ( ) ∼ 7 (−) 8 (+) General tolerance: ±0.3 ±.012 –4– ASCTB114E 201709-T To Be Discontinued Last time buy: September 30, 2018 HL 2 Form C External dimensions CAD Data 20.8 .819 Schematic (Bottom view) Standard type 27.2 1.071 6.35 .250 3 4 5 6 7 14.2 .559 4 5 6 5 6 8 (−) 7 (+) 8 LED DC type 1 2 1 2 3 4 3 4 5 6 5 6 ∼ 7 8 ( ) (−) ∼ ( ) 8 (+) General tolerance: ±0.3 ±.012 2. PC board type 1 Form C External dimensions CAD Data 3 7 3.7 .146 4.7 .185 6 .236 7.3 .287 8 2 4 LED AC type 0.5 .020 10 .394 2 1 3 1.2 .047 Compatible with tab terminal #187 series receptacle. 1 2 7 35.4 1.394 With diode type 1 20.8 .819 Schematic (Bottom view) Standard type 27.2 1.071 2 3 6 7 35.4 1.394 8 LED AC type 3.5 .138 1.5 .059 1.2 .047 5 .197 LED DC type 2 2 3 3 6 6 0.5 .020 7 ∼ 7 8 ( ) ( ) ∼ (−) 8 (+) 10 .394 2 3 6 7 8 3.75 .148 4.6 .181 6 .236 7.15 .281 PC board pattern (Bottom view) 4.6 .181 14.2 .559 General tolerance: ±0.3 ±.012 R3 R.118 10 .394 6 .236 R2 R.079 4 .157 14.2 .559 5-2 dia. hole 5-.079 dia. 17.75 .699 8.5 .335 7.15 .281 Tolerance: ±0.1 ±.004 –5– ASCTB114E 201709-T To Be Discontinued Last time buy: September 30, 2018 HL 2 Form C External dimensions CAD Data 20.8 .819 Schematic (Bottom view) Standard type 27.2 1.071 3.5 .138 2 3 4 5 6 7 35.4 1.394 1.5 .059 1 8 LED AC type 1.2 .047 5 .197 0.5 .020 LED DC type 1 2 1 2 3 4 3 4 5 6 5 6 7 ∼ 7 8 ( ) ( ) ∼ 8 (+) (−) 10 .394 1 2 3 4 5 6 7 8 3.7 .146 4.7 .185 6 .236 7.3 .287 PC board pattern (Bottom view) 8-2 dia. hole 8-.079 dia. 10 .394 14.2 .559 1.25 .049 1.25 .049 2 .079 1.25 .049 2 .079 General tolerance: ±0.3 ±.012 18 .709 13.3 .524 4 .157 R2 R.079 7.3 .287 14.2 .559 R2 R.079 4 4 Tolerance: ±0.1 ±.004 3. TM type 1 Form C External dimensions CAD Data Schematic (Bottom view) Standard type 43 1.693 20.6 .811 2 2 .079 3 6 7 34.4 1.354 1.2 .047 6.35 .250 Chassis (Panel) cutout Compatible with tab terminal #187 series receptacle. 37.6 1.470 Tolerance: ±0.1 ±.004 2 3 6 7 8 Chassis (Panel) cutout in tandem mounting 23 .906 2-3.2 to 3.5 dia. hole 2-.126 to .138 dia. 0.5 .020 3.6 .142 8 3.75 .148 4.6 .181 6 .236 37.6 7.15 1.480 .281 General tolerance: ±0.3 ±.012 –6– 37.6 1.470 21 21 .827 2 .827 .079 Notes: 1. If connecting to #187 series tab terminals, use AMP Faston #187 series or #187 tab terminals conforming to UL or CSA inch-standard dimensions. 2. In mounting, use M3 screws and M3 washers. 3. When mounting TM types, use washers to prevent damage or distortion to the polycarbonate cover. 4. When tightening fixing screws, the optimum torque range should be 0.294 to 0.49 N·m, (3 to 5 kgf·cm). Moreover, use washers to prevent loosening. ASCTB114E 201709-T To Be Discontinued Last time buy: September 30, 2018 HL 2 Form C External dimensions CAD Data Schematic (Bottom view) Standard type 43 1.693 20.6 .811 2 .079 1 2 3 4 5 6 7 8 34.4 1.354 1.2 .047 6.35 .250 Compatible with tab terminal #187 series receptacle. 1 2 3 4 5 6 7 8 23 .906 2-3.2 to 3.5 dia. hole 2-.126 to .138 dia. 0.5 .020 3.6 .142 Chassis (Panel) cutout in tandem mounting Chassis (Panel) cutout 37.6 1.470 37.6 1.470 21 21 .827 2 .827 .079 Tolerance: ±0.1 ±.004 3.7 .146 4.7 .185 6 37.6 .236 1.480 7.3 .287 Notes: 1. If connecting to #187 series tab terminals, use AMP Faston #187 series or #187 tab terminals conforming to UL or CSA inch-standard dimensions. 2. In mounting, use M3 screws and M3 washers. 3. When mounting TM types, use washers to prevent damage or distortion to the polycarbonate cover. 4. When tightening fixing screws, the optimum torque range should be 0.294 to 0.49 N·m, (3 to 5 kgf·cm). Moreover, use washers to prevent loosening. General tolerance: ±0.3 ±.012 SAFETY STANDARDS 1. Standard type (Plug-in type except with diode, PC board type, TM type) Contact arrangement 1 Form C 2 Form C UL/C-UL (Recognized) File No. Contact rating 15A 250V AC E43028*1 1/3HP 125, 250V AC 10A 30V DC 10A 250V AC E43028*1 1/3HP 125, 250V AC 10A 30V DC File No. — — CSA (Certified) Contact rating CSA standard certified by C-UL CSA standard certified by C-UL TV rating (UL/CSA) File No. Rating UL: E43149 NO➝TV-5 CSA: LR26550 NC➝TV-2 etc. UL: E43149 NO➝TV-4 CSA: LR26550 NC➝TV-2 etc. File No. B1305 13461 341 B1305 13461 341 TÜV rating Rating 15A 125V AC (cosφ =1.0) 10A 250V AC (cosφ =1.0) 10A 30V DC (L/R=0ms) 10A 250V AC (cosφ =1.0) 10A 30V DC (L/R=0ms) 2. Plug-in type (with diode)*2 Contact arrangement 1 Form C 2 Form C UL/C-UL (Recognized) File No. Contact rating 15A 250V AC E43028*1 1/3HP 125, 250V AC 10A 30V DC 10A 250V AC E43028*1 1/3HP 125, 250V AC 10A 30V DC File No. — — CSA (Certified) Contact rating CSA standard certified by C-UL CSA standard certified by C-UL TV rating (UL/CSA) File No. Rating — — File No. B1305 13461 341 — — B1305 13461 341 TÜV rating Rating 15A 125V AC (cosφ =1.0) 10A 250V AC (cosφ =1.0) 10A 30V DC (L/R=0ms) 10A 250V AC (cosφ =1.0) 10A 30V DC (L/R=0ms) Note: “*1” indicates the UL/C-UL recognition file number. “*2” DC coil Plug-in type with LED indication only. NOTES 1. For cautions for use, please read “General Application Guidelines”. –7– ASCTB114E 201709-T
HL2-PL-AC24V-F
物料型号:文档中列出了多种型号的继电器,包括不同形式的C(Form C)和不同电压等级的交流(AC)与直流(DC)型号。例如,HL1-H-AC6V-F、HL2-H-AC6V-F等。

器件简介:这是Panasonic Automation Controls的产品目录,介绍了HL系列的继电器,它们具有紧凑的高容量控制能力,高可靠性设计,丰富的产品线,以及多种接线端子选项。

引脚分配:文档中提供了不同类型继电器的引脚分配信息,例如1 Form C和2 Form C的配置。

参数特性:包括额定线圈电压、线圈电流、操作功率、线圈电阻、吸合电压、释放电压、电感、最大应用电压等。

功能详解:文档详细描述了继电器的特点,如无焊接构造、LED指示器、二极管类型等。

应用信息:继电器适用于多种应用,包括工厂自动化设备、汽车设备、控制面板、电源设备、注塑机、机床、焊接设备、农业设备等。

封装信息:提供了不同类型继电器的封装信息,包括插入式、PCB板类型、带LED指示的插入式等,以及它们的外部尺寸和CAD数据。
HL2-PL-AC24V-F 价格&库存

很抱歉,暂时无法提供与“HL2-PL-AC24V-F”相匹配的价格&库存,您可以联系我们找货

免费人工找货