LKS1AF-12V

LKS1AF-12V

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    RELAY GEN PURPOSE SPST 5A 12V

  • 数据手册
  • 价格&库存
LKS1AF-12V 数据手册
VDE LK-S 250 mW Slim Power Relay LK-S RELAYS 3. High noise immunity realized by the card separation structure between contact and coil 4. Popular terminal pitch in AV equipment field 5. Space-saving slim type Base area: Width 11 × Length 24 mm Width .433 × Length .945 inch 6. Conforms to the various safety standards UL/CSA, VDE, TÜV and SEMKO SEV approved FEATURES 24.0 .945 11.0 .433 25.0 .984 mm inch 1. High sensitivity: 250mW The power-saving relay is highly sensitive at the nominal operating power of 250 mW (530 mW power consumption on LK relays). 2. High insulation resistance between contact and coil 1) Creepage distance and clearances between contact and coil: Min. 6 mm .236 inch (In compliance with IEC65) 2) Surge withstand voltage between contact and coil: 10,000 V or more SPECIFICATIONS Contact Arrangement Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact material Nominal switching capacity Max. switching power Rating (resistive load) Max. switching voltage Max. switching current Mechanical (at 180 cpm) Expected life (min. operations) Electrical (at 20 cpm) (at rated load) 1 Form A Max. 100 mΩ Silver alloy 5 A 277 V AC 1,385 V A 277 V AC 5 A (AC) 106 105 Characteristics Max. operating speed Initial insulation resistance*1 Between open contacts Between contact and coil Initial surge voltage between contact and coil*3 Operate time*4 (at nominal voltage) Release time (without diode)*4 (at nominal voltage) Initial *2 breakdown voltage Temperature rise (at 70°C) 250 mW Shock resistance Functional*5 Destructive*6 Functional*7 Vibration resistance Destructive Conditions for operation, transport and storage*8 (Not freezing and condensing at low temperature) Unit weight Ambient temp. Humidity Air pressure 20 cpm (at rated load) Min. 1,000 MΩ (at 500 V DC) 1,000 Vrms for 1 min. 4,000 Vrms for 1 min. Min. 10,000 V Approx. 7 ms (at 20°C 68°F) Approx. 2 ms (at 20°C 68°F) Max. 35°C with nominal coil voltage and at 5 A contact carrying current (resistance method) Min. 200 m/s2{approx. 20 G} Min. 1,000 m/s2{approx. 100 G} 10 to 55Hz at double amplitude of 1.5mm 10 to 55Hz at double amplitude of 1.5mm –40°C to +70°C –40°F to +158°F 5 to 85% R.H. 86 to 106 kPa Approx. 12 g .42 oz Coil Nominal operating power Remarks * Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as "Initial breakdown voltage" section. *2 Detection current: 10mA *3 Wave is standard shock voltage of ±1.2 × 50µs according to JEC-212-1981 *4 Excluding contact bounce time. *5 Half-wave pulse of sine wave: 11 ms; detection time: 10 µs *6 Half-wave pulse of sine wave: 6 ms *7 Detection time: 10 µs *8 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 24). TYPICAL APPLICATIONS • Audio visual equipment • Office equipment • Home appliances ORDERING INFORMATION Ex. LKS Contact arrangement 1a: 1 Form A 1a F – 12V Coil voltage(DC) 5, 9, 12, 24V Protective construction F: Flux-resistant type UL/CSA, TÜV, SEMKO, TV-5 approved type is standard. Notes 1. Standard packing Carton: 100 pcs. Case: 500 pcs. 2. 6 V, 18 V DC types are also available. Please consult us for details. 53 LK-S TYPES AND COIL DATA (at 20°C 68°F) Part No. LKS1aF-5V LKS1aF-9V LKS1aF-12V LKS1aF-24V Nominal voltage, V DC 5 9 12 24 Pick-up voltage, V DC (max.) (Initial) 3.5 6.3 8.4 16.8 Drop-out voltage, V DC (min.) (Initial) 0.5 0.9 1.2 2.4 Coil resistance, Ω (±10%) 100 324 576 2,304 Nominal operating current, mA (±10%) 50 27.8 20.8 10.4 Nominal operating power, mW 250 250 250 250 Maximum allowable voltage, V DC (at 20°C 68°F) 6.5 11.7 15.6 31.2 mm inch PC board pattern (Bottom view) 2-0.9 dia 2-.035 dia Max. 25.0 .984 0.5 .020 4 .157 0.4 .016 1.0 .039 7.5 .295 20.0 .787 16.5 .650 2-1.3 dia 2-.051 dia 7.5 .295 20.0 .787 DIMENSIONS 0.5 dia. .020 dia. 1.65 .065 0.3 .012 Max. 24.0 .945 16.5 .650 Tolerance: ±0.1 ±.004 Schematic (Bottom view) Max. 11.0 .433 Dimension: Max. 1mm .039 inch: 1 to 3mm .039 to .118 inch: Min. 3mm .118 inch: General tolerance ±0.1 ±.004 ±0.2 ±.008 ±0.3 ±.012 REFERENCE DATA 1. Max. switching power (AC resistive load) 2. Coil temperature rise Sample: LKS1aF-12V, 6 pcs. Point measured: coil inside Contact current: 0 A, 5A 100 30 25 20 15 10 5 0 20°C 5A 20°C 0A 70°C 5A 70°C 0A 3. Ambient temperature characteristics and coil applied voltage Contact current: 5 A 500 Coil applied voltage, %V Temperature rise, °C Contact current, A 400 Allowable ambient temperatures against % coil voltages (max. inside the coil temperature set as 115°C 239°F) 10 5 300 200 Cold start 100 Pick-up voltage 1 0 10 100 Contact voltage, V 0 80 100 120 0 0 10 20 30 40 50 60 70 80 Coil applied voltage, %V Ambient temperature, °C 4. Life curve Operation frequency: 20 times/min. (ON/OFF = 1.5s: 1.5s) Ambient temperature: Room temperature 100 Life, ×104 250V AC resistive load 10 1 0 1 2 3 4 5 Contact current, A 54 LK-S 5-(1). Electrical life test (5 A 277 V AC, resistive load) Sample: LKS1aF-12V, 6 pcs. Operation frequency: 20 times/min. (ON/OFF = 1.5s: 1.5s) Ambient temperature: 20°C 68°F Change of pick-up and drop-out voltage 12 Pick-up and drop-out voltage, V 10 Pick-up voltage 8 6 4 Drop-out voltage 2 0 0 Max. x Min. 5 No. of operations, ×104 10 Max. x Min. Change of contact resistance 50 45 Contact resistance, mΩ 40 35 30 25 20 15 10 5 0 0 5 No. of operations, ×104 10 Max. x Min. Circuit: Contact welding detection and Miscontacting detection circuit 277V AC 12V DC 5-(2). Electrical life test (UL lamp load test TV-5) Tested sample: LKS1aF-12V, 6 pcs. • Overload test Load: 7.5 A 120 V AC (60 Hz), Inrush: 111 A Operation frequency: 10 times/min (ON: OFF = 1 s: 5 s) No. of operations: 50 ope. • Endurance test Load: 5A 120 V AC (60 Hz), Inrush: 78 A Operation frequency: 10 times/min (ON: OFF = 1 s: 5 s) No. of operations: 25,000 ope. Change of pick-up and drop-out voltage 12 Pick-up and drop-out voltage, V Change of contact resistance 50 45 Contact resistance, mΩ 10 8 6 4 Drop-out voltage 2 0 0 No. of operations, ×104 Max. x Min. 2.5 Pick-up voltage Max. x Min. 40 35 30 25 20 15 10 5 0 0 No. of operations, ×104 Max. x Min. 2.5 For Cautions for Use, see Relay Technical Information (Page 11 to 39). 55
LKS1AF-12V 价格&库存

很抱歉,暂时无法提供与“LKS1AF-12V”相匹配的价格&库存,您可以联系我们找货

免费人工找货