0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
RK1-L2-5V

RK1-L2-5V

  • 厂商:

    NAIS(松下)

  • 封装:

  • 描述:

    RK1-L2-5V - 1.5 GHz MICROWAVE RELAY - Nais(Matsushita Electric Works)

  • 数据手册
  • 价格&库存
RK1-L2-5V 数据手册
1.5 GHz MICROWAVE RELAY RK-RELAYS 20.2 .795 11.2 .441 9.7 .382 • Excellent high frequency characteristics Isolation: Min. 60dB (at 1.5 GHz) Insertion loss: Max. 0.3dB (at 900 MHz) • V.S.W.R.: Max. 1.5 (at 900MHz) • High sensitivity in small size Size: 20.2 × 11.2 × 9.7 mm .795 × .441 × .382 inch Nominal power consumption: 200 mW (single side stable type) • Sealed construction for automatic cleaning • Latching types are also available mm inch SPECIFICATIONS Contact Arrangement Contact material Initial contact resistance, max. (By HP4328A) Max. switching power Max. switching voltage Rating Max. switching current Nominal switching capacity High frequency Isolation characteristics Insertion loss (Impedance 50Ω) V.S.W.R. Expected life (min. operations) Mechanical Electrical 0.01 A 24 V DC 10 W 1.2 GHz 1 Form C Gold-clad 100 mΩ 10 W 30 V DC 0.5 A 0.01 A 24 V DC 10 W (at 1.2 GHz, Impedance 50Ω) Min. 60 dB (at 1.5 GHz) Max. 0.3 dB (at 900 MHz) Max. 1.5 (at 900 MHz) 5×10 105 6 Characteristics Initial insulation resistance*1 Between open contacts Initial Between contact and coil breakdown 2 Between contact and voltage* earth terminal Operate time [Set time]*3 (at nominal voltage) Min. 100 MΩ at 500 V DC 500 Vrms 1,000 Vrms 500 Vrms Approx. 6 ms [Approx. 5ms] Release time (without diode) [Reset time]*3 Approx. 3 ms [Approx. 5ms] (at nominal voltage) *2 Temperature rise Functional*4 Destructive*5 Functional*6 Destructive Max. 60°Cwith nominal coil voltage across coil and at nominal switching capacity Min. 196 m/s2 {20 G} Min. 980 m/s2 {100 G} 10 to 55 Hz at double amplitude of 3 mm 10 to 55 Hz at double amplitude of 5 mm –40°C to 60°C –40°F to 140°F 5 to 85% R.H. Approx. 4.4 g .155 oz Shock resistance 3×105 Vibration resistance Coil (at 25°C, 68°F) Nominal operating power Single side stable 1 coil latching 2 coil latching 200 mW 200 mW 400 mW Conditions for operation, transport and storage Ambient temp. (Not freezing and condensing Humidity at low temperature) Unit weight Remarks * Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as “Initial breakdown voltage” section *2 Detection current: 10mA *3 Excluding contact bounce time *4 Half-wave pulse of sine wave: 11ms, detection time: 10µs *5 Half-wave pulse of sine wave: 6ms *6 Detection time: 10µs TYPICAL APPLICATIONS • Audio visual equipment broadcast satellite tuners VCRs, CATVs, TVs • Communication equipment automobile telephones maritime telephones • Instrumentation test equipment measuring equipment ORDERING INFORMATION Ex. RK 1 L2 24V Contact arrangement 1: Standard type 1R: R type (See Schematic on next page.) Operating function Nil: Single side stable L: 1 coil latching L2: 2 coil latching Coil voltage, DC 3, 4.5, 5, 6, 9, 12, 24 V Note: Standard packing; Carton: 50 pcs. Case 500 pcs. 101 RK TYPES ANE COIL DATA (at 20°C 68°F) • Single side stable type Part No. RK1-3V RK1-4.5V RK1-5V RK1-6V RK1-9V RK1-12V RK1-24V RK1R-3V RK1R-4.5V RK1R-5V RK1R-6V RK1R-9V RK1R-12V RK1R-24V Nominal voltage, V DC 3 4.5 5 6 9 12 24 Nominal voltage, V DC 3 4.5 5 6 9 12 24 Pick-up voltage, max. V DC 2.25 3.38 3.75 4.5 6.75 9 18 Set voltage, max. V DC 2.25 3.38 3.75 4.5 6.75 9 18 Set voltage, max. V DC 2.25 3.38 3.75 4.5 6.75 9 18 Drop-out voltage, min. V DC 0.3 0.45 0.5 0.6 0.9 1.2 2.4 Reset voltage, max. V DC 2.25 3.38 3.75 4.5 6.75 9 18 Reset voltage, max. V DC 2.25 3.38 3.75 4.5 6.75 9 18 Coil resistance, Ω (±10%) 45 101 125 180 405 720 2,880 Coil resistance, Ω (±10%) 45 101 125 180 405 720 2,880 Coil resistance, Ω (±10%) 22.5 50.6 62.5 90 202.5 360 1,440 Nominal operating current, mA 66.7 44.4 40.7 33.3 22.2 16.7 8.3 Nominal operating current, mA 66.7 44.4 40 33.3 22.2 16.7 8.3 Nominal operating current, mA 133.3 88.9 80 66.7 44.4 33.3 16.7 Nominal operating power, mW 200 200 200 200 200 200 200 Nominal operating power, mW 200 200 200 200 200 200 200 Nominal operating power, mW 400 400 400 400 400 400 400 Maximum. allowable voltage, V DC (at 60°C 140°F) 3.3 4.95 5.5 6.6 9.9 13.2 26.4 Maximum. allowable voltage, V DC (at 60°C 140°F) • 1 coil latching type Part No. RK1-L-3V RK1-L-4.5V RK1-L-5V RK1-L-6V RK1-L-9V RK1-L-12V RK1-L-24V RK1R-L-3V RK1R-L-4.5V RK1R-L-5V RK1R-L-6V RK1R-L-9V RK1R-L-12V RK1R-L-24V 3.3 4.95 5.5 6.6 9.9 13.2 26.4 Maximum. allowable voltage, V DC (at 60°C 140°F) • 2 coil latching type Part No. RK1-L2-3V RK1-L2-4.5V RK1-L2-5V RK1-L2-6V RK1-L2-9V RK1-L2-12V RK1-L2-24V RK1R-L2-3V RK1R-L2-4.5V RK1R-L2-5V RK1R-L2-6V RK1R-L2-9V RK1R-L2-12V RK1R-L2-24V Nominal voltage, V DC 3 4.5 5 6 9 12 24 3.3 4.95 5.5 6.6 9.9 13.2 26.4 DIMENSIONS mm inch PC board pattern (Copper-side view) (Single side stable and 1 coil latching) 9-0.9 dia. 9-.035 dia. Schematic (Bottom view) Standard contact arrangement R type contact arrangement RK1 RK1R –1 +7 Single side –1 +7 stable (Deenergized condition) 14 13 12 11 10 9 COM 8 14 13 12 11 10 9 COM 8 N.C. N.O. N.O. N.C. 20.2 .795 11.2 .441 2.54 .100 2.54 .100 9.1 .358 3.5 .138 0.6 .024 2.54 .100 7.62 .300 7.62 .300 (2 coil latching) 10-0.9 dia. 10-.035 dia. 2.54 .100 +1 RK1-L –7 RK1R-L 1 coil latching (Reset condition) +1 –7 (Single side stable and 1 coil latching) 2-0.6×0.3 2-.024×.012 2.54 .100 14 13 12 11 10 9 RESET COM 8 14 13 12 11 10 9 SET COM 8 SET RESET Stand-off 3-0.45 3-.018 4-0.6×0.25 4-.024×.010 3-0.6×0.3 3-.024×.012 7.62 .300 Tolerance: ±0.1 ±.003 1 – (2 coil latching) RK1-L2 67 ++ RK1R-L2 2 coil latching (Reset condition) 1 – 67 ++ Stand-off 3-0.45 3-.018 4-0.6×0.25 4-.024×.010 14 13 12 11 10 9 RESET COM 8 14 13 12 11 10 9 SET COM 8 SET RESET General tolerance: ±0.3 ±.012 102 RK REFERENCE DATA 1.-(1) High frequency characteristics (Impedance 75Ω) Sample: RK1-12V Measuring method: Measured with HP network analyzer (HP8753C) • Insertion loss characteristics 0 COM-NO • Isolation characteristics 0 • V.S.W.R. characteristics 2.0 0.2 Insertion loss, dB Isolation, dB 20 1.8 COM-NO 0.6 60 COM-NC V.S.W.R. 0.4 COM-NC 40 1.6 1.4 COM-NO 0.8 80 1.2 COM-NC 1.0 300kHz 100 1.5GHz Frequency 3GHz 300kHz 1.5GHz Frequency 3GHz 1.0 300kHz 1.5GHz Frequency 3GHz 1.-(2) High frequency characteristics (Impedance 50Ω) Sample: RK1-5V Measuring method: Measured with HP network analyzer (HP8753C) • Insertion loss characteristics 0 • Isolation characteristics 0 • V.S.W.R. characteristics 2.0 0.2 Insertion loss, dB Isolation, dB 20 COM-NO V.S.W.R. 1.8 COM-NC 1.6 COM-NO 1.4 COM-NC 0.4 COM-NO 0.6 COM-NC 0.8 40 60 80 1.2 1.0 300kHz 100 1.5GHz Frequency 3GHz 300kHz 1.5GHz Frequency 3GHz 1.0 300kHz 1.5GHz Frequency 3GHz 2. Coil temperature rise Sample: RK1-12V, RK1-L-12V, RK1-L2-12V No. of samples: n = 6 Carrying current: 10 mA Ambient temperature: 25°C 77°F 100 Temperature rise, °C 3.-(1) Operate/Release time (Single side stable) Sample: RK1-12V; No. of samples: n = 6 3.-(2) Set/Reset time (Latching) Sample: RK1-L-12V, RK1-L2-12V No. of samples: n = 12 10 Operate/Reset time, ms 10 Set time Reset time Operate time 6 60 RK1-12V, RK1-L-12V 40 Set/Reset time, ms 80 RK1-L2-12V 8 8 6 4 Max. Min. Max. Min. Release time 4 20 2 Max. Max. Min. Min. 2 0 80 100 130 150 Voltage applied to coil, %V 0 80 100 120 150 Voltage applied to coil, %V 0 80 100 130 Voltage applied to the coil (%V) 103 RK 4.-(1) Mechanical life test (Single side stable) Sample: RK1-12V; No. of samples: n = 12 12 Pick-up/drop-out voltage, V 10 Pick-up voltage 8 6 4 2 0 Drop-out voltage Max. Min. Max. Min. 4.-(2) Mechanical life test (Latching) Sample: RK1-L2-12V No. of samples: n = 12 12 4.-(3) Mechanical life test Sample: RK1-12V No. of samples: n = 20 (20 × 2 contacts) 300 Contact resistance, mΩ 250 200 150 100 50 Min. 0 Max. Set/Reset voltage, V 10 8 6 4 2 0 Max. Min. 100 500 1,000 No. of operations, ×104 100 500 1,000 No. of operations, ×104 50 100 500 1,000 No. of operations, ×104 5. Electrical life test (0.01 A 24 V DC) Sample: RK1-12V; No. of samples: n = 6 12 Pick-up/drop-out voltage, V 6. Ambient temperature characteristics Sample: RK1-12V; No. of samples: n = 6 7. Contact resistance distribution (initial) Sample: RK1-12V No. of samples: n = 50 (50 × 2 contacts) Rate of change, % 10 Pick-up voltage 8 6 4 2 0 Drop-out voltage Max. Min. Max. Min. –40 –20 –40 –4 0 40 Pick-up voltage Quantity 20 Drop-out voltage 20 40 60 80 68 104 140 176 –20 Ambient temperature, °C °F –40 50 40 30 20 10 0 10 20 No. of operations, ×104 30 10 20 30 40 50 Contact resistance, mΩ 8.-(1) Influence of adjacent mounting Sample: RK1-12V; No. of sample: n = 10 Rate of change, % 8.-(2) Influence of adjacent mounting Sample: RK1-12V; No. of samples: n = 10 Rate of change, % 10 Pick-up voltage 0 –10 OFF condition OFF OFF 10 Pick-up voltage 0 –10 OFF OFF OFF condition Rate of change, % Rate of change, % 10 Drop-out voltage 0 –10 ON ON 10 Drop-out voltage 0 ON ON ON condition –10 ON condition 5 10 .197 .394 Inter-relay distance, (mm, inch) 5 10 .197 .394 Inter-relay distance, (mm, inch) NOTES 1. Soldering Perform soldering under the conditions below. • Within 10 s at 260°C 500°F • Within 3 s at 350°C 662°F 2. Latching relay In order to assure proper operating regardless of changes in the ambient usage temperature and usage conditions, nominal operating voltage should be applied to the coil for more than 30 ms to set/reset the latching type relay. For Cautions for Use, see Relay Technical Information (Page 48 to 76). 104 9/1/2000 All Rights Reserved, © Copyright Matsushita Electric Works, Ltd. Go To Online Catalog
RK1-L2-5V 价格&库存

很抱歉,暂时无法提供与“RK1-L2-5V”相匹配的价格&库存,您可以联系我们找货

免费人工找货