0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
NITPC-2512

NITPC-2512

  • 厂商:

    NI

  • 封装:

  • 描述:

    NITPC-2512 - 12.1 in. SVGA TFT color LCD touch screen/500 MHz AMD LX800 processor - National Instrum...

  • 数据手册
  • 价格&库存
NITPC-2512 数据手册
12 in. Industrial Touch Panel Computer NI TPC-2512 NEW! • 12.1 in. SVGA TFT color LCD touch screen with 800 x 600 resolution • 500 MHz AMD LX800 processor • 512 MB DDR SDRAM memory • NEMA4/IP65-compliant front panel NI Hardware Support • USB data acquisition (DAQ) • NI CompactDAQ • NI PACs: CompactRIO, NI Single-Board RIO, Compact FieldPoint, and PXI Communication Ports • • • • 2 Hi-Speed USB ports 1 Ethernet (10/100BASE-T) 4 serial ports (3 RS232 and 1 RS232/485) PS2 keyboard/mouse Installed Software Support • Windows XP Embedded on a 4 GB CompactFlash card • NI-DAQmx 8.7.2 for NI USB DAQ devices • Hardware Touch Panel Deployment License Overview The NI TPC-2512 touch panel computer (TPC) features a 12.1 in. highquality 800 x 600 SVGA LCD touch screen. It offers a 500 MHz AMD GX3 processor and 512 MB SDRAM, and is shipped with a 4 GB CompactFlash storage device with Windows XP Embedded. The TPC-2512 is certified to work with the NI LabVIEW Touch Panel Module. For data acquisition systems, the TPC-2512 includes NI-DAQmx components for USB data acquisition devices. detect new TPC-2512 devices over Ethernet and then update IP settings and add the device to your project (see Figure 1). LabVIEW offers a single HMI and logic development environment for creating user interfaces and embedded programs for real-time hardware using the LabVIEW Real-Time Module. Touch Panel Computer Hardware Support The TPC-2512 comes with NI-DAQmx 8.7.2 installed for out-of-the-box connectivity to NI CompactDAQ and all NI USB DAQ devices compatible with NI-DAQmx. Support for shared variables as both a host and client plus Modbus TCP/IP or standard TCP/IP makes the TPC-2512 an ideal human machine interface (HMI) for NI programmable automation controllers (PACs) including CompactRIO, NI Single-Board RIO, Compact FieldPoint, and PXI real-time controllers. It provides a wide range of connectivity options including the following: • 10/100BASE-T Ethernet for connectivity to NI PACs • Two Hi-Speed USB ports for NI CompactDAQ and USB DAQ • Four serial ports (three RS232 and one RS232/485) Figure 1. LabVIEW Project with NI TPC-2512 LabVIEW for HMI Development The TPC-2512 works with the LabVIEW Touch Panel Module and includes one Touch Panel Deployment License. From the LabVIEW Project, you can Figure 2. TPC-2512 Connectivity a. b. c. d. e. f. g. h. CPU card cover CompactFlash slot Parallel port Serial ports Ethernet port USB ports Power switch PS/2 ports Hardware TPC-2106/T (ARM) TPC-2012 (x86) TPC-2512 (x86) 1The 2LabVIEW Operating System Windows CE Windows CE Windows XP Embedded Shared Variables Client Client Host and client LabVIEW Touch Panel Module 8.6 TCP/IP and UDP NI-DAQmx NI-DAQmx Modbus Base – TCP/IP and ASCII   1,2 – TCP/IP and ASCII  2 – TCP/IP and ASCII  2 NI-VISA RS232    Serial-Compatible VIs (RS232/RS485)    TPC-2106/T supports only USB DAQ devices that are USB 1.1 compatible 8.6 and NI-DAQmx 8.7.2 or NI-DAQmx Base 3.2 or later are required Table 1. NI Touch Panel Computer Driver Compatibility 12 in. Industrial Touch Panel Computer Figure 6. Standard TCP/IP Communication with Native LabVIEW TCP/IP VIs Figure 3. TPC-2512 Dimensions (mm) Typical System Configurations With the LabVIEW Touch Panel Module, you have several options for communication between the TPC-2512, NI USB DAQ devices, NI PACs, and third-party programmable logic controllers (PLCs) including: • NI-DAQmx • Shared variables over Ethernet • Modbus TCP/IP or Modbus ASCII over Ethernet or serial • Native LabVIEW TCP/IP, UDP, or SMTP With this wide range of communication options, you can select the best communication method for your application. The LabVIEW shared variable offers the easiest solution for communication over Ethernet and shortens development time so you can build a powerful user interface. For more advanced programming requirements, use the native LabVIEW TCP/IP or UDP VIs to develop Ethernet-based communication or add e-mailing capabilities with built-in LabVIEW SMTP e-mail VIs. For connectivity to Modbus PLCs or RTU controllers, use the LabVIEW Modbus Library to easily communicate between a TPC and a PLC through the industry-standard Modbus protocol over Ethernet or serial. Industrial Windows CE Touch Panel Computer Figure 4. Shared-Variable Communication between NI PACs and a Touch Panel Ordering Information NI TPC-2512 with Windows XP Embedded ..........................780541-01 Includes one Touch Panel Deployment License. Related Products NI TPC-2012 with Windows CE ..........................................779861-01 Includes one Touch Panel Deployment License. Figure 5. Modbus TCP/IP or ASCII Communication between a Touch Panel Computer and PLCs, RTU, or Modbus I/O NI PS-5 Power Supply ..........................................................778805-90 NI LabVIEW Touch Panel Module ......................................779708A-09 BUY NOW! For complete product specifications, pricing, and accessory information, call 800 813 3693 (U.S.) or go to ni.com/hmi. BUY ONLINE a t ni.com o r CALL 800 813 3693 (U.S.) 2 12 in. Industrial Touch Panel Computer Power Requirement 18 to 32 VDC ....................................... 60 W peak 500 MHz GX3 LX800 512 MB DDR SDRAM 4 GB CompactFlash 1 2 3 1 1 Windows XP Embedded SVGA TFT LCD 800 x 600 12.1 in. 100 deg 340 (cd/m2) 256 K 50,000 h 8-wire, analog resistive 1 million touches at single point 47,492 h (Bellcore) Specifications System Components Processor............................................. Memory ............................................... Storage................................................ I/O ports 10/100BASE-T Ethernet.................. Hi-Speed USB ................................. RS232.............................................. RS485.............................................. PS/2 keyboard/mouse .................... OS .................................................... Physical Dimensions (h by w by d).................... 237 by 311 by 50 mm (12.24 by 9.33 by 1.97 in.) Mounting............................................. Panel (standard) Weight................................................. 2.2 kg (4.84 lb) Environmental Ingress protection ............................... Operating temperature ....................... Storage temperature........................... Relative humidity ................................ Front panel NEMA4/IP65 0 to 50 °C (32 to 122 °F) -20 to 70 °C (-4 to 122 °F) 10 to 95% @ 40 °C (noncondensing) Vibration, operating ............................ 2 grms Altitude................................................ 2000 m Display Description .......................................... Resolution ........................................... Size .................................................... Viewing angle ..................................... Luminance ........................................... Max colors .......................................... Backlight life ....................................... Touch screen ....................................... Touch screen life span ........................ MTBF ................................................... Safety and EMC/EMI Compliance EMC/EMI............................................. CE, FCC Part 15 Class A Ratings ................................................ NEMA Type 4, IP65 Safety .................................................. UL, BEMI, CCC BUY ONLINE a t ni.com o r CALL 800 813 3693 (U.S.) 3 NI Services and Support IN TA PL SERVICE NEEDS LO Y V DE NI has the services and support to meet your needs around the globe and through the application life cycle – from planning and development through deployment and ongoing maintenance. We offer services and service levels to meet customer requirements in research, design, validation, and manufacturing. Visit ni.com/services. Local Sales and Technical Support In offices worldwide, our staff is local to the country, giving you access to engineers who speak your language. NI delivers industry-leading technical support through online knowledge bases, our applications engineers, and access to 14,000 measurement and automation professionals within NI Developer Exchange forums. Find immediate answers to your questions at ni.com/support. We also offer service programs that provide automatic upgrades to your application development environment and higher levels of technical support. Visit ni.com/ssp. MA IN Training and Certification NI training is the fastest, most certain route to productivity with our products. NI training can shorten your learning curve, save development time, and reduce maintenance costs over the application life cycle. We schedule instructor-led courses in cities worldwide, or we can hold a course at your facility. We also offer a professional certification program that identifies individuals who have high levels of skill and knowledge on using NI products. Visit ni.com/training. EL OP AN Professional Services Our Professional Services Team is composed of NI applications engineers, NI Consulting Services, and a worldwide National Instruments Alliance Partner program of more than 600 independent consultants and integrators. Services range from start-up assistance to turnkey system integration. Visit ni.com/alliance. OEM Support We offer design-in consulting and product integration assistance if you want to use our products for OEM applications. For information about special pricing and services for OEM customers, visit ni.com/oem. P DE Hardware Services NI Factory Installation Services NI Factory Installation Services (FIS) is the fastest and easiest way to use your PXI or PXI/SCXI combination systems right out of the box. Trained NI technicians install the software and hardware and configure the system to your specifications. NI extends the standard warranty by one year on hardware components (controllers, chassis, modules) purchased with FIS. To use FIS, simply configure your system online with ni.com/pxiadvisor. Calibration Services NI recognizes the need to maintain properly calibrated devices for high-accuracy measurements. We provide manual calibration procedures, services to recalibrate your products, and automated calibration software specifically designed for use by metrology laboratories. Visit ni.com/calibration. Repair and Extended Warranty NI provides complete repair services for our products. Express repair and advance replacement services are also available. We offer extended warranties to help you meet project life-cycle requirements. Visit ni.com/services. ni.com • 800 813 3693 National Instruments • info@ni.com *351635A-01* 351635A-01 2008-9844-161-101-D ©2008 National Instruments. All rights reserved. CompactRIO, FieldPoint, LabVIEW, National Instruments, National Instruments Alliance Partner, NI, ni.com, NI CompactDAQ, and SCXI are trademarks of National Instruments. Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent from National Instruments and has no agency, partnership, or joint-venture relationship with National Instruments.
NITPC-2512 价格&库存

很抱歉,暂时无法提供与“NITPC-2512”相匹配的价格&库存,您可以联系我们找货

免费人工找货