0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
CV500-BSC61

CV500-BSC61

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    BASIC MODULE RS232C

  • 数据手册
  • 价格&库存
CV500-BSC61 数据手册
Cat. No. W195-E1-5 SYSMAC CV-series CV500/CV1000/CV2000/CVM1 Programmable Controllers SYSMAC CV-series CV500/CV1000/CV2000/CVM1 Programmable Controllers Installation Guide Revised October 1999 iv Notice: OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual. The following conventions are used to indicate and classify precautions in this manual. Always heed the information provided with them. Failure to heed precautions can result in injury to people or damage to property. DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. ! WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. ! Caution Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury, or property damage. ! OMRON Product References All OMRON products are capitalized in this manual. The word “Unit” is also capitalized when it refers to an OMRON product, regardless of whether or not it appears in the proper name of the product. The abbreviation “Ch,” which appears in some displays and on some OMRON products, often means “word” and is abbreviated “Wd” in documentation in this sense. The abbreviation “PC” means Programmable Controller and is not used as an abbreviation for anything else. Visual Aids The following headings appear in the left column of the manual to help you locate different types of information. Note Indicates information of particular interest for efficient and convenient operation of the product. 1, 2, 3... 1. Indicates lists of one sort or another, such as procedures, checklists, etc. © OMRON, 1992 All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission of OMRON. No patent liability is assumed with respect to the use of the information contained herein. Moreover, because OMRON is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice. Every precaution has been taken in the preparation of this manual. Nevertheless, OMRON assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained in this publication. v vi TABLE OF CONTENTS PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 General Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Operating Environment Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Application Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Conformance to EC Directives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1-2 1-3 1-4 1-5 1-6 1-7 1-8 1-9 Control Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . The Role of the PC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PC Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CV-series Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-series–CV-series System Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Networks and Remote I/O Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . New CPUs and Related Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CPU Comparison . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Improved Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 2 System Configuration and Components . . . . . . . . . . . . . . 2-1 2-2 2-3 System Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Racks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rack Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 3 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 3-2 3-3 3-4 3-5 3-6 Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mounting Racks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Supply Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wiring I/O Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Compliance with EC Directives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 4 Inspection and Maintenance . . . . . . . . . . . . . . . . . . . . . . . 4-1 4-2 4-3 4-4 CPU Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Memory Card Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Output Unit Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Output Unit Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 5 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1 5-2 5-3 Error Messages and Alarm Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Troubleshooting Flowcharts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Error Processing and Correction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Appendices A Standard Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii About this Manual: This manual describes the installation of the SYSMAC CV-series Programmable Controllers (CV500, CV1000, CV2000, and CVM1). This manual is designed to be used together with three CV-series PC operation manuals. The entire set of CV-series PC manuals is listed below. Only the basic portions of the catalog numbers are given; be sure you have the most recent version for your area. Manual Cat. No. CV-series PC Installation Guide W195 CV-series PC Operation Manual: SFC W194 CV-series PC Operation Manual: Ladder Diagrams W202 CV-series PC Operation Manual: Host Interface W205 Programming and operating CV-series PCs are performed with the CV Support Software (CVSS), the SYSMAC Support Software (SSS), and the CV-series Programming Console for which the following manuals are available. Product Manuals CVSS The CV Series Getting Started Guidebook (W203) and the CV Support Software Operation Manuals: Basics (W196), Offline (W201), and Online (W200). SSS SYSMAC Support Software Operation Manuals: Basics (W247), C-series PC Operations (W248), and CVM1 Operations (W249) CV-series Programming Console CVM1-PRS21-E Programming Console Operation Manual (W222) Note The CVSS does not support new instructions added for version-2 CVM1 PCs. The SSS does not support SFC programming (CV500, CV1000, or CV2000). Section 1 introduces programmable controllers in general and provides tables of the Units the can be used with CV-series PCs and operation manuals available for CV-series products. Special products used to create networks, enable remote I/O, or provide additional programming capabilities are also provided. Tables are also provided of new products included for the first time in this version of the manual, along with a comparison of CPU capabilities, and a list of improvements made in recent CPU versions. Section 2 describes the overall configuration that the PC System can take and introduces the main Units used in the system configuration. Section 3 provides procedures on installing and wiring. Section 4 provides information on ongoing maintenance. Section 5 describes general troubleshoot and provides troubleshooting flowcharts. Appendix A provides tables of C- and CV-series products that can be used with CV-series PCs. Appendix B provides general PC specifications, dimensions, and I/O Unit specifications (including internal circuit configurations and wiring diagrams). ! WARNING Failure to read and understand the information provided in this manual may result in personal injury or death, damage to the product, or product failure. Please read each section in its entirety and be sure you understand the information provided in the section and related sections before attempting any of the procedures or operations given. ix PRECAUTIONS This section provides general precautions for using the Programmable Controller (PC) and related devices. The information contained in this section is important for the safe and reliable application of the Programmable Controller. You must read this section and understand the information contained before attempting to set up or operate a PC system. 1 Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 General Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Operating Environment Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Application Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Conformance to EC Directives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi 3 Safety Precautions 1 Intended Audience This manual is intended for the following personnel, who must also have knowledge of electrical systems (an electrical engineer or the equivalent). • Personnel in charge of installing FA systems. • Personnel in charge of designing FA systems. • Personnel in charge of managing FA systems and facilities. 2 General Precautions The user must operate the product according to the performance specifications described in the operation manuals. Before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems, machines, and equipment that may have a serious influence on lives and property if used improperly, consult your OMRON representative. Make sure that the ratings and performance characteristics of the product are sufficient for the systems, machines, and equipment, and be sure to provide the systems, machines, and equipment with double safety mechanisms. This manual provides information for programming and operating the Unit. Be sure to read this manual before attempting to use the Unit and keep this manual close at hand for reference during operation. ! WARNING It is extremely important that a PC and all PC Units be used for the specified purpose and under the specified conditions, especially in applications that can directly or indirectly affect human life. You must consult with your OMRON representative before applying a PC System to the above-mentioned applications. 3 Safety Precautions ! WARNING Do not attempt to take any Unit apart while the power is being supplied. Doing so may result in electric shock. ! WARNING Do not touch any of the terminals or terminal blocks while the power is being supplied. Doing so may result in electric shock. ! WARNING Do not attempt to disassemble, repair. or modify any Units. Any attempt to do so may result in malfunction, fire, or electric shock. ! WARNING There is a lithium battery built into the SRAM Memory Cards. Do not short the positive and negative terminals of the battery, charge the battery, attempt to take it apart, subject it to pressures that would deform it, incinerate it, or otherwise mistreat it. Doing any of these could cause the battery to erupt, ignite, or leak. ! Caution xii Tighten the screws on the terminal block of the AC Power Supply Unit to the torque specified in the operation manual. The loose screws may result in burning or malfunction. 5 Application Precautions 4 Operating Environment Precautions ! Caution Do not operate the control system in the following places: • Locations subject to direct sunlight. • Locations subject to temperatures or humidity outside the range specified in the specifications. • Locations subject to condensation as the result of severe changes in temperature. • Locations subject to corrosive or flammable gases. • Locations subject to dust (especially iron dust) or salts. • Locations subject to exposure to water, oil, or chemicals. • Locations subject to shock or vibration. ! Caution Take appropriate and sufficient countermeasures when installing systems in the following locations: • Locations subject to static electricity or other forms of noise. • Locations subject to strong electromagnetic fields. • Locations subject to possible exposure to radioactivity. • Locations close to power supplies. ! Caution 5 The operating environment of the PC System can have a large effect on the longevity and reliability of the system. Improper operating environments can lead to malfunction, failure, and other unforeseeable problems with the PC System. Be sure that the operating environment is within the specified conditions at installation and remains within the specified conditions during the life of the system. Application Precautions Observe the following precautions when using the PC System. ! WARNING Always heed these precautions. Failure to abide by the following precautions could lead to serious or possibly fatal injury. • Always ground the system to 100 Ω or less when installing the Units. Not connecting to a ground of 100 Ω or less may result in electric shock. • Always turn OFF the power supply to the PC before attempting any of the following. Not turning OFF the power supply may result in malfunction or electric shock. • Mounting or dismounting I/O Units, Memory Cassettes, or any other Units. • Setting switches. • Connecting cables or wiring the system. • Connecting or disconnecting the connectors. ! Caution Failure to abide by the following precautions could lead to faulty operation of the PC or the system, or could damage the PC or PC Units. Always heed these precautions. • Fail-safe measures must be taken by the customer to ensure safety in the event of incorrect, missing, or abnormal signals caused by broken signal lines, momentary power interruptions, or other causes. xiii Conformance to EC Directives 6 • Interlock circuits, limit circuits, and similar safety measures in external circuits (i.e., not in the Programmable Controller) must be provided by the customer. • Always use the power supply voltage specified in the operation manuals. An incorrect voltage may result in malfunction or burning. • Take appropriate measures to ensure that the specified power with the rated voltage and frequency is supplied. Be particularly careful in places where the power supply is unstable. An incorrect power supply may result in malfunction. • Install external breakers and take other safety measures against short-circuiting in external wiring. Insufficient safety measures against short-circuiting may result in burning. • Do not apply voltages to the Input Units in excess of the rated input voltage. Excess voltages may result in burning. • Do not apply voltages or connect loads to the Output Units in excess of the maximum switching capacity. Excess voltages or loads may result in burning. • Disconnect the functional ground terminal when performing withstand voltage tests. Not disconnecting the functional ground terminal may result in burning. • Install the Unit properly as specified in the operation manual. Improper installation of the Unit may result in malfunction. • Be sure that all the mounting screws, terminal screws, and cable connector screws are tightened to the torque specified in the relevant manuals. Incorrect tightening torque may result in malfunction. • Use crimp terminals for wiring. Do not connect bare stranded wires directly to terminals. Connection of bare stranded wires may result in burning. • Double-check all the wiring before turning on the power supply. Incorrect wiring may result in burning. • Be sure that the terminal blocks, Memory Units, expansion cables, and other items with locking devices are properly locked into place. Improper locking may result in malfunction. • Check the user program for proper execution before actually running it on the Unit. Not checking the program may result in an unexpected operation. • Confirm that no adverse effect will occur in the system before attempting any of the following. Not doing so may result in an unexpected operation. • Changing the operating mode of the PC. • Force-setting/force-resetting any bit in memory. • Changing the present value of any word or any set value in memory. • Resume operation only after transferring to the new CPU Unit the contents of the DM Area, HR Area, and other data required for resuming operation. Not doing so may result in an unexpected operation. • Do not pull on the cables or bend the cables beyond their natural limit. Doing either of these may break the cables. • Do not place objects on top of the cables. Doing so may break the cables. 6 Conformance to EC Directives The CV-series PCs that comply with EC Directives must be installed as follows: 1, 2, 3... xiv 1. The CV-series PCs are designed for installation inside control panels. The PC must be installed within a control panel. 2. Use reinforced insulation or double insulation for the DC power supplies to be connected to the DC I/O Units for CV500-PS211. Use separate power supplies as the external power supplies for the Relay Output Units and the power supplies for the DC I/O Units. 3. To meet the EC Directives (Low Voltage Directive), the maximum switching capacity while the CV500-PS211 is being operated is 24 VDC/2 A. 6 Conformance to EC Directives 4. PCs complying with EC Directives also conform to the Common Emission Standard (EN50081-2). When a PC is built into a machine, however, noise can be generated by switching devices using relay outputs and cause the overall machine to fail to meet the Standards. If this occurs, surge killers must be connected or other measures taken external to the PC. The following methods represent typical methods for reducing noise, and may not be sufficient in all cases. Required countermeasures will vary depending on the devices connected to the control panel, wiring, the configuration of the system, and other conditions. Countermeasures Refer to EN50081-2 for more details. Countermeasures are not required if the frequency of load switching for the whole system including the PC is less than 5 times per minute. Countermeasures are required if the frequency of load switching for the whole system including the PC is 5 or more times per minute. Countermeasure Examples When switching an inductive load, connect a surge protector, diodes, etc., in parallel with the load or contact as shown below. Circuit Current AC Power supply Yes No Power supply Yes Inductive load Varistor method Required element If the load is a relay or solenoid, there is a time lag between the moment the circuit is opened and the moment the load is reset. The capacitance of the capacitor must be 1 to 0.5 μF per contact current of 1 A and resistance of the resistor must be 0.5 to 1 Ω per contact voltage of 1 V. These values, however, vary with the load and the characteristics of the relay. Decide these values from testing, and take into consideration that the capacitance suppresses spark discharge when the contacts are separated and the resistance limits the current that flows into the load when the circuit is closed again. If the supply voltage is 24 or 48 V, insert the surge protector in parallel with the load. If the supply voltage is 100 to 200 V, insert the surge protector between the contacts. Yes Inductive load Diode method Power supply Yes Inductive load CR method Characteristic DC Yes The diode connected in parallel with the load changes energy accumulated by the coil into a current, which then flows into the coil so that the current will be converted into Joule heat by the resistance of the inductive load. The dielectric strength of the capacitor must be 200 to 300 V. If the circuit is an AC circuit, use a capacitor with no polarity. The reversed dielectric strength value of the diode must be at least 10 times as large as the circuit voltage value. The forward current of the diode must be the same as or larger than the load current. This time lag, between the moment the circuit is opened and the moment the load is reset, caused by this method is longer than that caused by the CR method. The reversed dielectric strength value of the diode may be two to three times larger than the supply voltage if the surge protector is applied to electronic circuits with low circuit voltages. The varistor method prevents the imposition of high voltage between the contacts by using the constant voltage characteristic of the varistor. There is time lag between the moment the circuit is opened and the moment the load is reset. --- If the supply voltage is 24 or 48 V, insert the varistor in parallel with the load. If the supply voltage is 100 to 200 V, insert the varistor between the contacts. xv 6 Conformance to EC Directives When switching a load with a high inrush current such as an incandescent lamp, suppress the inrush current as shown below. Countermeasure 1 Countermeasure 2 R OUT OUT R COM Providing a dark current of approx. one-third of the rated value through an incandescent lamp xvi COM Providing a limiting resistor SECTION 1 Introduction This section provides general information about Programmable Controllers and how they fit into a Control System. It also list the C-series products that can be used with the CV-series PCs and operation manuals available for CV-series products. Finally, this section introduces Systems that can be used to create networks and enable remote I/O. 1-1 1-2 1-3 1-4 1-5 1-6 1-7 1-8 1-9 Control Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . The Role of the PC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2-1 Input Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2-2 Output Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PC Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CV-series Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-series–CV-series System Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Networks and Remote I/O Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . New CPUs and Related Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CPU Comparison . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Improved Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9-1 Upgraded Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9-2 Version-1 CPUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9-3 Version-2 CVM1 PCs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Section 1-2 The Role of the PC 1-1 Control Systems A Control System is the electronic equipment needed to control a particular process. It may include everything from a process control computer, to the factory computer, down through the PCs, and then on down through the network to the I/O devices: control components like the switches, stepping motors, solenoids, and sensors which monitor and control mechanical operations. Process Control Computer Factory Computer PCs PC PC PC I/O devices A Control System can involve very large applications where many different models of PC are networked together or it could be an application as small as a single PC controlling a number of output devices. 1-2 The Role of the PC The PC is the part of the Control System that directly controls the manufacturing process. According to the program stored in its memory, the PC accepts data from the input devices connected to it and uses this data to monitor the controlled system. When the program calls for some action to take place, the PC sends data to the output devices connected to it to cause that action to take place. The PC may be used to control a simple, repetitive task, or it may be connected to other PCs or to a host computer in order to integrate the control of a complex process. 2 Section 1-2 The Role of the PC 1-2-1 Input Devices PCs can receive inputs from either automated or manual devices. The PC could receive data from the user via a pushbutton switch, keyboard, or similar device. Automated inputs could come from a variety of devices: micro-switches, timers, encoders, photoelectric sensors, and so on. Some devices, like the limit switch shown below, turn ON or OFF when the equipment actually makes contact with them. Other devices, like the photoelectric sensor and proximity sensor shown below, use other means, such as light or inductance, in order to get information about the equipment being monitored. Photoelectric Sensor Proximity Sensor Limit Switch 1-2-2 Output Devices A PC can output to a myriad of devices for use in automated control. Almost anything that you can think of could be controlled by a PC. Some of the most common devices are motors, solenoids, servomotors, stepping motors, valves, switches, indicator lights, buzzers, and alarms. Some of these output devices, such as the motors, solenoids, servomotors, stepping motors, and valves, affect the controlled system directly. Others, such as the indicator lights, buzzers, and alarms, provide outputs to notify personnel operating or monitoring the system. Solenoid Servomotor Stepping Motor 3 Section 1-3 PC Operation 1-3 PC Operation PCs operate by monitoring input signals and providing output signals. When changes are detected in input signals, the PC reacts through the user-programmed internal logic to produce output signals. The PC continually executes the program in its memory to achieve this control. Block Diagram of PC Power Supply Memory Signals from switches, sensors, etc. Input CPU Output Signals to Solenoids, motors, etc. Programming Device A program for your applications must be designed and stored in the PC. This program is then executed as part of the cycle of internal operations of the PC. Execution Cycle When a PC operates, i.e., when it executes its program to control an external system, a series of operations are performed inside the PC. These internal operations can be broadly classified into the following four categories. Refer to the CV-series PCs Operation Manual: Ladder Diagrams for details. 1, 2, 3... 1. Common (or overseeing) processes, such as watchdog timer operation and testing the program memory. 2. Data input and output. 3. Program execution. 4. Peripheral device servicing. Cycle Time The total time required for a PC to perform all these internal operations is called the cycle time. Timing is one of the most important factors in designing a Control System. For accurate operations, it is necessary to have answers to such questions as these: • How long does it take for the PC to execute all the instructions in its memory? • How long does it take for the PC to produce a control output in response to a given input signal? 4 Section 1-4 CV-series Manuals The cycle time of the PC can be automatically calculated and monitored, but it is necessary to have an understanding of the timing relationships within the PC for effective System design and programming. Refer to the CV-series PCs Operation Manual: Ladder Diagrams for details on internal PC processing and to the CVSS Operation Manuals for details on monitoring the cycle time. 1-4 CV-series Manuals The following manuals are available for the various CV-series products. Other manuals are also available for compatible C-series products (see next section). Catalog number suffixes have been omitted; be sure you have the most recent version for your region. Product CV-series PCs CV Support Software ((CVSS)) SYSMAC Support Software (SSS) Manual Cat. No. CV-series PCs Installation Guide W195 CV-series PCs Operation Manual: SFC W194 CV-series PCs Operation Manual: Ladder Diagrams W202 CV-series PCs Operation Manual: Host Link System, CV500-LK201 Host Link Unit W205 The CV Series Getting Started Guidebook CV Support Software Operation Manual: Basics CV Support Software Operation Manual: Offline W203 W196 W201 CV Support Software Operation Manual: Online W200 SYSMAC Support Software Operation Manual: Basics W247 SYSMAC Support Software Operation Manual: CVM1 PCs W249 Graphic Programming Console (GPC) CV500-MP311-E Graphic Programming Console Operation Manual W216 Programming Console CVM1-PRS21-E Programming Console Operation Manual W222 SYSMAC NET Link System SYSMAC NET Link System Manual W213 SYSMAC LINK System SYSMAC LINK System Manual W212 SYSMAC BUS/2 Remote I/O System SYSMAC BUS/2 Remote I/O System Manual W204 CompoBus/D (DeviceNet) CompoBus/D (DeviceNet) Operation Manual W267 CV-series Ethernet Unit CV-series Ethernet System Manual W242 BASIC Unit BASIC Unit Reference Manual W207 BASIC Unit Operation Manual W206 Temperature Controller Data Link Unit Personal Computer Unit Operation Manual Personal Computer Unit Technical Manual Motion Control Unit Operation Manual: Introduction Motion Control Unit Operation Manual: Details CV500-TDL21 Temperature Controller Data Link Unit W251 W252 W254 W255 W244 Memory Card Writer CV500-MCW01-E Memory Card Writer Operation Manual W214 Optical Fiber Cable Optical Fiber Cable Installation Guide W156 Personal Computer Unit Motion Control Unit 5 Section 1-5 C-series–CV-series System Compatibility 1-5 C-series–CV-series System Compatibility The following table shows when C-series Units can be used and when CV-series Units must be used. Any C-series Unit or Peripheral Device not listed in this table cannot be used with the CV-series PCs. Unit CPU Rack C Series CV Series Remarks CPU No Yes CV500-CPU01-EV1, CV1000-CPU01-EV1, CV2000-CPU01-EV1, CVM1-CPU01-EV2, CVM1-CPU11-EV2, and CVM1-CPU21-EV2 Power Supply No Yes CV500-PS221, CV500-PS211, and CVM1-PA208 CPU Backplane No Yes CV500-BC031, CV500-BC051, CV500-BC101, CVM1-BC103, and CVM1-BC053 I/O Control Unit No Yes CV500-ICj01 Expansion CPU Backplane No Yes CV500-BI111 Expansion I/O Backplane No Yes 16-/32-/64-point I/O Units Yes Yes CV500-BI042, CV500-BI062, CV500-BI112, CVM1-BI114, and CVM1-BI064 (C500 Expansion I/O Racks can be used with certain limitations.) --- Special I/O Units Yes Yes Applicable Units include Analog Input, Analog Output, High-speed Counter, PID, Position Control, Magnetic Card, ASCII, ID Sensor, and Ladder Program I/O Units (The C500-ASC03 cannot be used.) BASIC Unit No Yes CV500-BSCj1 Personal Computer Unit No Yes CV500-VP213-E/217-E/223-E/227-E Temperature Control Data Link Unit Link SYSMAC NET S Systems SYSMAC LINK No Yes CV500-TDL21 Host Link Unit No No No Yes Yes Yes CV500-SNT31 CV500-SLK11 and CV500-SLK21 CV500-LK201 Ethernet Unit No Yes CV500-ETN01 SYSMAC BUS Units SYSMAC BUS/2 CV Support Software Yes No No Yes Yes Yes (See note.) --CV500-RM211/221 and CV500-RT211/221 CV500-ZS3AT1-EV2 (3 1/2” floppy disks) and CV500-ZS5AT1-EV2 (5 1/4” floppy disks) for IBM PC/AT compatible SYSMAC Support Software (SSS) Yes Yes (See note.) C500-ZL3AT1-E (3.5” floppy disks) for IBM PC/AT compatible Graphic Programming Console Yes (Main unit only) GPC: 3G2C5-GPC03-E Programming Console No Yes (System Cassette) (See note.) Yes (See note.) Remote I/O S Systems Peripheral Devices System Cassette: CV500-MP311-E CVM1-PRS21-EV1 (set) Note The CVSS does not support new instructions added for version-2 CVM1 PCs. The SSS does not support SFC programming (CV500, CV1000, and CV2000). New instructions added for version-2 CVM1 PCs are also supported by version-1 CV-series Programming Consoles. 6 Section 1-6 Networks and Remote I/O Systems 1-6 Networks and Remote I/O Systems Systems that can be used to create networks and enable remote I/O are introduced in this section. Refer to the operation manuals for the Systems for details. SYSMAC NET Link System The SYSMAC NET Link System is a LAN (local area network) for use in factory automation systems. The SYSMAC NET Link System can consist of up to 128 nodes among which communications may be accomplished via datagrams, data transfers, or automatic data links. Datagrams transmit and receive data using a command/response format. Commands can be issued from the user program by the DELIVER COMMAND instruction (CMND(194)). Data can also be transmitted and received using the NETWORK SEND and NETWORK RECEIVE (SEND(192)/RECV(193)) instructions in the user program. Up to 256 words of data can be transferred for each instruction. Automatic data links allow PCs and computers to create common data areas. SYSMAC NET Link Unit CV500-SNT31 Up to 4 Units can be mounted. CV-series CPU Rack/Expansion CPU Rack Line Server Center Power Feeder Personal computer C200H C500 C1000H C2000H Note Up to four SYSMAC NET Link Units (CV500-SNT31) can be mounted to the CPU Rack and/or Expansion CPU Rack of each CV-series PC. 7 Section 1-6 Networks and Remote I/O Systems SYSMAC LINK System Networks can also be created using SYSMAC LINK Systems. A SYSMAC LINK System can consist of up to 62 PCs, including the CV500, CV1000, CV2000, CVM1, C200H, C1000H, and C2000H. Communications between the PCs is accomplished via datagrams, data transfers, or automatic data links in ways similar to the SYSMAC NET Link System. The main differences between SYSMAC NET Link and SYSMAC LINK Systems is in the structure of automatic data links and in the system configuration, e.g., only PCs can be linked in SYSMAC LINK Systems, whereas other devices can form nodes in SYSMAC NET Link Systems. Datagrams transmit and receive data using a command/response format. Commands can be issued from the user program by the DELIVER COMMAND instruction (CMND(194)). Data can also be transmitted and received using the NETWORK SEND and NETWORK RECEIVE (SEND(192)/RECV(193)) instructions in the user program. Up to 256 words of data can be transferred for each instruction. Automatic data links allow PCs and computers to create common data areas. SYSMAC LINK Unit CV500-SLK11 (optical) CV500-SLK21 (wired) Up to 4 Units can be mounted. CV-series CPU Rack/Expansion CPU Rack CV500/CV1000/ CV2000/CVM1 C200H/C1000H/ C2000H Note Up to four SYSMAC LINK Units (CV500-SLK11/21) can be mounted the CPU Rack and/or Expansion CPU Rack of each CV-series PC. 8 Section 1-6 Networks and Remote I/O Systems SYSMAC BUS/2 Remote I/O System Remote I/O can be enabled by adding a SYSMAC BUS/2 Remote I/O System to the PC. The SYSMAC BUS/2 Remote I/O System is available in two types: optical and wired. Two Remote I/O Master Units, optical or wired, can be mounted to the CV500 or CVM1-CPU01-EV2 CPU Rack or Expansion CPU Rack. Four Remote I/O Master Units can be mounted to the CV1000, CV2000, or CVM1-CPU11/21-EV2 CPU Rack or Expansion CPU Rack. Up to eight Remote I/O Slave Racks can be connected per PC. Slaves can be used to provide up to 1,024 remote I/O points for the CV500 or CVM1-CPU01-EV2; up to 2,048 remote I/O points for the CV1000, CV2000, or CVM1-CPU11/21-EV2. These limits are the totals for all Slaves control by one PC. A Programming Device (such as the CVSS) can be connected to up to two Remote I/O Slave Units for each Remote I/O Master Unit as long as a total of no more than four Programming Devices are connected per PC. Remote I/O Master Unit CV500-RM211 (optical) CV500-RM221 (wired) CV500, CVM1-CPU01-EV2: 4 Masters max. can be mounted CV1000, CV2000, CVM1-CPU11/21-EV2: 8 Masters max. can be mounted CV-series CPU Rack/Expansion CPU Rack Remote I/O Slave Up to 8 Slave can be connected per PC for 58M Slaves; 4 Slaves for 122M or 54MH Slaves. Remote I/O Slave Unit CV500-RT211 (optical) CV500-RT221 (wired) 9 Section 1-6 Networks and Remote I/O Systems SYSMAC BUS Remote I/O System Remote I/O can also be enabled by using the C-series SYSMAC BUS Remote I/O System with CV-series PC. Remote I/O Master Units can be mounted on any slot of the CPU Rack, Expansion CPU Rack, or Expansion I/O Rack. Up to four Masters can be mounted for the CV500 or CVM1-CPU01-EV2, up to eight Masters for the CV1000, CV2000, or CVM1-CPU11/21-EV2. For each Master, up to two Slave Racks can be connected for the CV500 or CVM1-CPU01-EV2; up to eight Slave Racks for the CV1000, CV2000, or CVM1-CPU11/21-EV2. No more than 16 Slave Racks can be connected per PC. Slaves can be used to provide up to 512 remote I/O points for the CV500 or CVM1-CPU01-EV2; up to 1,024 remote I/O points for the CV1000, CV2000, or CVM1-CPU11-EV2; up to 2,048 remote I/O points for the CVM1-CPU21-EV2. These limits are the totals for all Slaves control by one PC. Programming Devices cannot be connected to SYSMAC BUS Slave Racks. Remote I/O Master Unit 3G2A5-RM001-(P)EV1 (optical) C500-RM201 (wired) CV500, CVM1-CPU01-EV2: 2 Masters max. can be mounted CV1000, CV2000, CVM1-CPU11/21-EV2: 4 Masters max. can be mounted Up to 8 Units CV-series CPU Rack/Expansion CPU Rack/Expansion I/O Rack C-series Remote I/O Slave Rack Host Link System (SYSMAC WAY) The CV-series PCs can be connected to a host computer with the host link connector via the CPU or a CV500-LK201 Host Link Unit mounted to a Rack. RS-232C or RS-422 communications can be used depending on the switch setting. When RS-422 is selected, up to 32 PCs can be connected to a single host. Data is transmitted and received by commands and responses. Host computer Host link connector 10 Section 1-7 New CPUs and Related Units BASIC Unit The BASIC Unit can be connected to a personal computer to enable communications with the PC using the BASIC programming language. Up to 512 bytes (256 words) of data can be transferred between the BASIC Unit and the CPU by the PC READ/WRITE command without using the PC program. Up to 256 words of data can also be transferred between the BASIC Unit and the PC’s CPU by using the NETWORK SEND and NETWORK RECEIVE (SEND(192)/RECV(193)) instructions in the PC program. Data can also be transferred to other BASIC Units mounted on the same PC, or to BASIC Units mounted to other PCs connected by networks formed using a SYSMAC NET Link or SYSMAC LINK System. RS-232C, RS-422, Centronics, and GPIB interfaces are available. BASIC Unit CV500-BSCj1 CV-series CPU Rack/Expansion CPU Rack Personal computer Personal Computer Unit 1-7 The Personal Computer Unit is a full-fledged IBM PC/AT compatible that can be used to run independent programming directly on a Rack to eliminate the need for separate installation space. It can run along or connected to any of the normal peripherals supported by IBM PC/AT compatibles (mice, keyboards, monitors, data storage devices, etc.), and as a CPU Bus Unit, the Personal Computer Unit interfaces directly to the PC’s CPU though the CPU bus to eliminate the need for special interface hardware, protocols, or programming. New CPUs and Related Units The following new CV-series CPUs and related Units are included in this version of the manual for the first time. Refer to relevant sections of this manual or the CV-series PC Operation Manual: Ladder Diagrams for further details. Unit CPU Temperature Controller Data Link Unit Model number CVM1-CPU01-EV2 CVM1-CPU11-EV2 CVM1-CPU21-EV2 CV500-CPU01-EV1 CV1000-CPU01-EV1 CV2000-CPU01-EV1 CV500-TDL21 Main specifications I/O capacity: 512 pts; Ladder diagrams only I/O capacity: 1,024 pts; Ladder diagrams only I/O capacity: 2,048 pts; Ladder diagrams only I/O capacity: 512 pts; Ladder diagrams or SFC + ladder diagrams I/O capacity: 1,024 pts; Ladder diagrams or SFC + ladder diagrams I/O capacity: 2,048 pts; Ladder diagrams or SFC + ladder diagrams Connects up to 64 temperature control devices via 2 ports. 11 Section 1-9 Improved Specifications 1-8 CPU Comparison The following table shows differences between the various CV-series CPUs. CVM1CPU01-EV2 CPU Ladder diagrams Program- SFC P ming Instructions CVM1CPU11-EV2 CVM1CPU21-EV2 CV500CPU01-EV1 CV1000CPU01-EV1 CV2000CPU01-EV1 Supported Supported Supported Supported Supported Supported Not supported Not supported Not supported Supported Supported Supported 284 284 285 169 170 170 Basic instructions (ms) 0.15 to 0.45 0.125 to 0.375 0.125 to 0.375 0.15 to 0.45 0.125 to 0.375 0.125 to 0.375 Other instructions (ms) 0.6 to 9.9 0.5 to 8.25 0.5 to 8.25 0.6 to 9.9 0.5 to 8.25 0.5 to 8.25 Program capacity (see note) 30K words 30K words 62K words 30K words 62K words 62K words Local I/O capacity 512 pts 1,024 pts 2,048 pts 512 pts 1,024 pts 2,048 pts Remote I/O capacity SYSMAC BUS/2 1,024 pts 2,048 pts 2,048 pts 1,024 pts 2,048 pts 2,048 pts SYSMAC BUS 512 pts 1,024 pts 2,048 pts 512 pts 1,024 pts 1,024 pts 8K words 24K words 24K words 8K words 24K words 24K words Not supported 32K words each for 8 banks 32K words each for 8 banks Speed DM Area Expansion DM Area Not supported Not supported 32K words each for 8 banks Timers 512 1,024 1,024 512 1,024 1,024 Counters 512 1,024 1,024 512 1,024 1,024 SFC steps None None None 512 1,024 1,024 Step Flags None None None 512 1,024 1,024 Transition Flags None None None 512 1,024 1,024 Note The useable program capacity is 28K words or 60K words. 1-9 Improved Specifications 1-9-1 Upgraded Specifications The following improvements are applicable to all CV500-CPU01-E and CV1000-CPU01-E CPUs with lot numbers in which the rightmost digit is 3 (jjj3) or higher. 1, 2, 3... 1. The MLPX(110) (4-TO-16 DECODER) instruction has been improved to also function as a 8-to-256 decoder and the DMPX(111) (16-TO-4 ENCODER) instruction has been improved to also function as a 256-to-8 encoder. To enable this improvement, the digit designator (Di) has been changed as shown below. Digit number: 3 2 1 0 0 Specifies the first digit to be converted 4-to-16/16-to-4: 0 to 3 8-to-256/256-to-8: 0 or 1 Number of digits to be converted 4-to-16/16-to-4: 0 to 3 (1 to 4 digits) 8-to-256/256-to-8: 0 or 1 (1 or 2 digits) Process 0: 4-to-16/16-to-4 1: 8-to-256/256-to-8 2. The following operating parameter has been added to the PC Setup. JMP(004) 0000 Processing Y: Enable multiple usage (default) N: Disable multiple usage 12 Section 1-9 Improved Specifications 3. The operation of Completion Flags for timers has been changed so that the Completion Flag for a timer turns ON only when the timer instruction is executed with a PV of 0000 and not when the timer’s PV is refreshed to a PV value of 0000, as was previously done. Only the timing of the activation of the Completion Flag has been changed, and the timer’s PV is still refreshed at the same times (i.e., when the timer instruction is executed, at the end of user program execution, and every 80 ms if the cycle time exceeds 80 ms). 4. The READ(190) (I/O READ) and WRIT(191) (I/O WRITE) instructions have been improved so that they can be used for Special I/O Units on Slave Racks under the following conditions. a) The lot number of the Remote I/O Master Unit and Remote I/O Slave Unit must be the same as or latter than the following. 01 X 2 1992 October (Y: November; Z: December) 1st b) The DIP switch on the Remote I/O Slave Unit must be set to “54MH.” c) The Special I/O Unit must be one of the following: AD101, CT012, CT021, CT041, ASC04, IDS01-V1, IDS02, IDS21, IDS22, or LDP01-V1. (The NC221-E, NC222, CP131, and FZ001 cannot be mounted to Slave Racks.) 1-9-2 Version-1 CPUs CV-series CPUs were changed to version 1 from December 1993. The new model numbers are as follows: CVM1-CPU01-EV1, CVM1-CPU11-EV1, CV500-CPU-EV1, CV1000-CPU-EV1, and CV2000-CPU-EV1. (Of these, all CVM1 CPUs were changed to version 2 from December 1994; refer to the next sections for details.) The following additions and improvements were made to create the version-1 CPUs. PT Link Function The host link interface on the CPU can be used to connect directly to Programmable Terminals (PTs) to create high-speed data links. To use the PT links, turn ON pin 3 of the DIP switch on the CPU. Pin 3 must be turned OFF for host link connections. EEPROM Writes With the new CPUs, you can write to EEPROM Memory Cards mounted to the CPU by using the file write operation from a Peripheral Device. A Memory Card Writer is no longer required for this write operation. Writing is possible in PROGRAM mode only. New Command A new I/O REGISTER command (QQ) has been added so that words from different data areas can be read at the same time. Faster Host Links The communications response time for the built-in host link interface on the CPU has been improved by a factor of approximately 1.2. Faster Searches The search speed from Peripheral Devices for instructions and operands has been nearly doubled. 1-9-3 Version-2 CVM1 PCs CVM1 CPUs were changed to version 2 and a new CPU was added from December 1994. The new model numbers are as follows: CVM1-CPU01-EV2, CVM1-CPU11-EV2, and CVM1-CPU21-EV2. 13 Section 1-9 Improved Specifications The following additions and improvements were made to create the version-2 CPUs. CMP/CMPL New versions of the CMP(020) and CMPL(021) have been added that are not intermediate instructions. The new instructions are CMP(028) and CMPL(029) and are programs as right-hand (final) instructions. A total of 24 other new comparison instructions have also been added with symbol mnemonics (e.g., >, +, and
CV500-BSC61 价格&库存

很抱歉,暂时无法提供与“CV500-BSC61”相匹配的价格&库存,您可以联系我们找货

免费人工找货