0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
E32-T84S

E32-T84S

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

  • 描述:

    E32-T84S - Optical Fiber Photoelectric Sensor - Omron Electronics LLC

  • 数据手册
  • 价格&库存
E32-T84S 数据手册
Sensing distance Supply voltage 12 to 24 VDC Output 100 mA (Optical fiber series) Optical Fiber Photoelectric Sensor Leading-edge Features and Long-distance Sensing in an Optical Fiber Photoelectric Sensor E3X-Tjj with Auto-tuning Function Automatic Sensitivity Adjustment E3X-H11 High-sensitivity Model Senses Distances Twice as Far as those of E3X-Ajj and Performs Detailed Sensing Operations Using the Variable Hysteresis Function E3X-Ajj Standard Model A High-speed Response of 200 µs E3X-Fjj High-speed Model Pulse Lighting Mechanism Enables a High-speed Response of 20 µs E3X-VGjj Mark Sensor Model Green Light Source Accurately Senses Subtle Differences in Color at a Speed of 200 ms E3X Ordering Information Model Number Legend: E3X 1234 1. Classification T: Auto-tuning H: High-sensitivity A: General-purpose F: Shorter response time V: For mark sensor 2. Light Source None: Red (standard) G: Green 3. Outputs 1: NPN (without self-diagnosis) 2: NPN (with self-diagnosis) 4: PNP (without self-diagnosis) 5: PNP (with self-diagnosis) 4. Output Form 1: Cable (Cannot be used with the E3X-Tjj.) Accessories (Order Separately) 1 E3X Item Application Manual Sensitivity Adjustment Knob Makes adjustment possible without screwdriver. Water-resistance lost when used (enclosure rating reduced to IP50). E39-G3 Protective Cover E3X Replacement part for cover supplied with Amplifier Unit. E39-G4 Model Appearance Amplifier Units Item Model Appearance 32 Auto-tuning E3X-T11 E3X-T21 High-sensitivity E3X-H11 59 12 Light source Power supply voltage Current consumption Response time Control output Timer function Self-diagnosis alarm output Variable hysteresis function Tuning monitor function Remote tuning function/ Remote bank function Red LED (660 nm) 12 to 24 VDC +10%, ripple (p-p) 10% max. 50 mA max. 500 ms max. 100 mA max. at 30 VDC, NPN open collector ------Indicator (red/green LED) and buzzer --When ON, short-circuit the blue and pink wires. (Short-circuit the blue and purple wires for remote bank selection.): Short-circuit voltage 3 V max., short-circuit current 5 mA min. When OFF, open the blue and pink wires: 9 V min. (input voltage: 24 V max.), response time 100 ms max. when OFF. OFF-delay timer (fixed to 40 ms), switch selectable 50 mA max. at 30 VDC, open collector --0% to 20% ----10 to 30 VDC +10%, ripple (p-p) 10% max. 35 mA max. 1 m sec max. Output method Light ON and Dark ON selector 2 E3X Item Model Appearance NPN PNP General-purpose E3X-A11 E3X-A41 E3X-A21 E3X-A51 Shorter response time E3X-F21 E3X-F51 --For mark sensing E3X-VG11 E3X-VG21 --- E3X Light source Power supply voltage Red (660 nm) 10 to 30 VDC ripple (p-p) 10% max. 35 mA max. 200 ms max. 12 to 24 VDC +10% ripple (p-p) 10% max. 40 mA max. ON: 20 ms max. OFF: 30 ms max. OFF-delay timer (0.01 to 0.1 s; adjustable), Switch selectable Green (565 nm) 10 to 30 VDC ripple (p-p) 10% max. Current consumption Response time Control output Timer function 200 ms max. 100 mA, 30 VDC max., Open collector ----OFF-delay timer (0.01 to 0.1 s; adjustable), Switch selectable 50 mA, 30 VDC max. Residual voltage: 1 VDC max. Light OFF: 1.5 V max; short current: 0.2 mA max. Light ON: Open; 3.5 V min. (max. input: 5 V) Self-diagnosis alarm output --- 50 mA, 30 VDC max. Residual voltage: 1 VDC max. --- External diagnosis input Input voltage --- Light OFF: NPN: 1.5 V max; short current: 0.2 mA max. PNP: ±1.5 V max.; short current: 0.2 mA max. Light ON: NPN: Open; Light OFF: 3.5 V min. (max. input: 5 V) PNP: Open; ±3.5 VDC max. (max. input: 5 V) 400 ms 200 ms --- Response delay 400 ms 3 E3X Fiber Unit Through-beam (Separate) Sensors Model Appearance Sensing distance (standard object)* (T: E3X-Tjj; H: E3X-H11; A: E3X-Ajj; F: E3X-Fjj; V: E3X-VGjj) T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: 500 mm (1,200 mm**) (1.4-mm dia. min.) 700 mm (2,000 mm**) (1.4-mm dia. min.) 350 mm (1,000 mm**) (1.4-mm dia. min.) 150 mm (1.4-mm dia. min.) 40 mm (120 mm**) (1.4-mm dia. min.) 500 mm (1.4-mm dia. min.) 700 mm (1.4-mm dia. min.) 350 mm (1.4-mm dia. min.) 150 mm (1.4-mm dia. min.) 40 mm (1.4-mm dia. min.) 150 mm (0.9-mm dia. min.) 200 mm (0.9-mm dia. min.) 100 mm (0.9-mm dia. min.) 50 mm (0.9-mm dia. min.) 10 mm (0.9-mm dia. min.) 150 mm (0.9-mm dia. min.) 200 mm (0.9-mm dia. min.) 100 mm (0.9-mm dia. min.) 50 mm (0.9-mm dia. min.) 10 mm (0.9-mm dia. min.) 270 mm (2,000 mm**) (1-mm dia. min.) 400 mm (3,000 mm**) (1-mm dia. min.) 200 mm (1,500 mm**) (1-mm dia. min.) 80 mm (1-mm dia. min.) 28 mm (190 mm**) (1-mm dia. min.) 270 mm (1-mm dia. min.) 400 mm (1-mm dia. min.) 180 mm (1-mm dia. min.) 80 mm (1-mm dia. min.) 28 mm (1-mm dia. min.) 70 mm (0.5-mm dia. min.) 100 mm (0.5-mm dia. min.) 50 mm (0.5-mm dia. min.) 26 mm (0.5-mm dia. min.) 7 mm (0.5-mm dia. min.) 70 mm (0.5-mm dia. min.) 100 mm (0.5-mm dia. min.) 50 mm (0.5-mm dia. min.) 26 mm (0.5-mm dia. min.) 8 mm (0.5-mm dia. min.) 70 mm (0.5-mm dia. min.) 100 mm (0.5-mm dia. min.) 50 mm (0.5-mm dia. min.) 26 mm (0.5-mm dia. min.) 8 mm (0.5-mm dia. min.) 250 mm (1-mm dia. min.) 360 mm (1-mm dia. min.) 180 mm (1-mm dia. min.) 80 mm (1-mm dia. min.) 28 mm (1-mm dia. min.) 240 mm (1,300 mm**) (1-mm dia. min.) 360 mm (1-mm dia. min.) 180 mm (1,000 mm**) (1-mm dia. min.) 80 mm (1-mm dia. min.) 10 mm (120 mm**) (1-mm dia. min.) 65 mm (0.5-mm dia. min.) 100 mm (0.5-mm dia. min.) 50 mm (0.5-mm dia. min.) 26 mm (0.5-mm dia. min.) 6 mm (0.5-mm dia. min.) Min. sensing object (opaque objects) T: H: A: F: V: T: H: A: F: V: 0.2-mm dia. 0.5-mm dia. 0.5-mm dia. 0.5-mm dia. 0.5-mm dia. 0.2-mm dia. 0.5-mm dia. 0.5-mm dia. 0.5-mm dia. 0.5-mm dia. E3X Features E32-T11L M4 screw Long distance E32-T12L 3-mm dia. Long distance E32-T21L M3 screw 0.2-mm dia. Long distance with thin fiber E32-T22L 2-mm dia. 0.2-mm dia. Long distance with thin fiber E32-TC200 M4 screw 0.2-mm dia. General-purpose E32-TC200B E32-TC200B4 0.2-mm dia. General-purpose M4 screw E32-T22 2-mm dia. 0.2-mm dia. General-purpose E32-TC200E M3 screw 0.2-mm dia. General-purpose E32-TC200F E32-TC200F4 0.2-mm dia. General-purpose M3 screw E32-TC200A M3 screw T: H: A: F: V: T: H: A: F: V: 0.2-mm dia. 0.3-mm dia. 0.2-mm dia. 0.2-mm dia. 0.2-mm dia. 0.2-mm dia. 0.3-mm dia. 0.2-mm dia. 0.2-mm dia. 0.2-mm dia. General-purpose E32-T11 M4 screw Flexible (resists breaking) E32-T21 M3 screw 0.2-mm dia. Flexible (resists breaking) *Standard object: opaque; **For the E39-F1; ***Not trimmable 4 E3X Model Appearance Sensing distance (standard object)* (T: E3X-Tjj; H: E3X-H11; A: E3X-Ajj; F: E3X-Fjj; V: E3X-VGjj) T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: 200 mm (800 mm**) (1-mm dia. min.) 300 mm (1,600 mm**) (1-mm dia. min.) 150 mm (800 mm**) (1-mm dia. min.) 60 mm (1-mm dia. min.) 18 mm (100 mm) (1-mm dia. min.) 200 mm (1-mm dia. min.) 300 mm (1-mm dia. min.) 150 mm (1-mm dia. min.) 60 mm (1-mm dia. min.) 18 mm (1-mm dia. min.) 130 mm (1-mm dia. min.) 240 mm (1-mm dia. min.) 120 mm (1-mm dia. min.) 30 mm (1-mm dia. min.) 10 mm (1-mm dia. min.) 45 mm (0.5-mm dia. min.) 90 mm (0.5-mm dia. min.) 45 mm (0.5-mm dia. min.) 15 mm (0.5-mm dia. min.) 2 mm (0.5-mm dia. min.) 1,000 mm (4-mm dia. min.) 1,800 mm (4-mm dia. min.) 900 mm (4-mm dia. min.) 380 mm (4-mm dia. min.) 80 mm (4-mm dia. min.) 7,000 mm (10-mm dia. min.) 14,000 mm (10-mm dia. min.) 7,000 mm (10-mm dia. min.) 3,000 mm (10-mm dia. min.) 800 mm (10-mm dia. min.) 1,000 mm (4-mm dia. min.) 1,600 mm (4-mm dia. min.) 800 mm (4-mm dia. min.) 300 mm (4-mm dia. min.) 70 mm (4-mm dia. min.) 200 mm (2-mm dia. min.) 300 mm (2-mm dia. min.) 150 mm (2-mm dia. min.) 65 mm (2-mm dia. min.) 20 mm (2-mm dia. min.) 300 mm (1.5-mm dia. min.) 400 mm (1.5-mm dia. min.) 200 mm (1.5-mm dia. min.) 80 mm (1.5-mm dia. min.) 20 mm (1.5-mm dia. min.) 180 mm (2,000 mm**) (1.0-mm dia. min.) 300 mm (3,000 mm**) (1.0-mm dia. min.) 150 mm (1,500 mm**) (1.0-mm dia. min.) 60 mm (450 mm) (1.0-mm dia. min.) 18 mm (130 mm**) (1.0-mm dia. min.) Min. sensing object (opaque objects) 0.2-mm dia. E3X Features E32-TC200C M4 screw **** Flexible spiral cord E32-TC200D E32-TC200D4 M4 screw **** 0.2-mm dia. Flexible spiral cord E32-T14L 3-mm dia. T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: 0.3-mm dia. 0.2-mm dia. 0.1-mm dia. 0.2-mm dia. 0.1-mm dia. 0.2-mm dia. 0.1-mm dia. 0.1-mm dia. 0.3-mm dia. 0.2-mm dia. 0.2-mm dia. 1-mm dia. 1-mm dia. 0.2-mm dia. 2-mm dia. 0.7-mm dia. 2.1-mm dia. 0.8-mm dia. 1.5-mm dia. 2.1-mm dia. 0.3-mm dia. 0.7-mm dia. 0.9-mm dia. 0.7-mm dia. 0.6-mm dia. 0.2-mm dia. 0.4-mm dia. 0.3-mm dia. 0.3-mm dia. 0.3-mm dia. 0.4-mm dia. 1.0-mm dia. 1.0-mm dia. 1.0-mm dia. 1.0-mm dia. 0.2-mm dia. 0.3-mm dia. 0.2-mm dia. 0.5-mm dia. 0.5-mm dia. Side-view; long distance E32-T24 1-mm dia. Side-view; save space E32-T14 Side-view E32-T17L M4 screw Long distance E32-T12F 5-mm dia. Teflon-covered*****; withstands chemicals and harsh environments 4-head; 4-point sensing E32-M21 M3 screw **** E32-T51 M4 screw Heat-resistant; resists 150°C E32-T61 M4 screw **** Heat-resistant; resists 300°C *Standard object: opaque; **For the E39-F1.; ***Sensing distances for slit applications are in the following table. ****Not trimmable *****Teflon is a registered trademark of the Dupont Company and the Mitsui Dupont Chemical Company for their fluoride resin. 5 E3X E32-T16 with Slits Slit width With E3X-Tjj With E3X-H11 With E3X-Ajj With E3X-Fjj With E3X-VGjj Sensing distance Min. sensing object Sensing distance Min. sensing object Sensing distance Min. sensing object Sensing distance Min. sensing object Sensing distance Min. sensing object 450 mm 0.2-mm dia. 900 mm 0.2-mm dia. 450 mm 0.25-mm dia. 120 mm 0.25-mm dia. 20 mm 0.25-mm dia. 0.5-mm 800 mm 0.3-mm dia. 1,200 mm 0.4-mm dia. 600 mm 0.35-mm dia. 250 mm 0.35-mm dia. 60 mm 0.35-mm dia. Slit Sensing object E3X 1.0-mm Sensing method Reflective Sensors Model Appearance Sensing distance (standard object) (T: E3X-Tjj; H: E3X-H11; A: E3X-Ajj; F: E3X-Fjj; V: E3X-VGjj) White paper E32-D11L M6 screw Min. sensing object (copper wire) Features Black paper T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: 40 mm (20 x 20 cm) 60 mm (20 x 20 cm) 30 mm (10 x 10 cm) 8 mm (5 x 5 cm) --20 mm (10 x 10 cm) 32 mm (20 x 20 cm) 16 mm (10 x 10 cm) 3 mm (2.5 x 2.5 cm) --9 mm (5 x 5 cm) 14 mm (5 x 5 cm) 7 mm (2.5 x 2.5 cm) 2 mm (2.5 x 2.5 cm) --9 mm (5 x 5 cm) 14 mm (5 x 5 cm) 7 mm (2.5 x 2.5 cm) 2 mm (2.5 x 2.5 cm) --20 mm (10 x 10 cm) 30 mm (20 x 20 cm) 15 mm (10 x 10 cm) 5 mm (5 x 5 cm) --20 mm (10 x 10 cm) 30 mm (20 x 20 cm) 15 mm (10 x 10 cm) 5 mm (5 x 5 cm) --4.8 mm (2.5 x 2.5 cm) 7.2 mm (5 x 5 cm) 3.6 mm (2.5 x 2.5 cm) 1.5 mm (2.5 x 2.5 cm) --4.8 mm (2.5 x 2.5 cm) 7.2 mm (5 x 5 cm) 3.6 mm (2.5 x 2.5 cm) 1.5 mm (2.5 x 2.5 cm) --T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: 0.015-mm dia. 0.015-mm dia. 0.015-mm dia. 0.2-mm dia. 3.0-mm dia. 0.015-mm dia. 0.015-mm dia. 0.04-mm dia. 2.4-mm dia. 1.6-mm dia. 0.015-mm dia. 0.015-mm dia. 0.03-mm dia. 0.26-mm dia. 1.0-mm dia. 0.015-mm dia. 0.015-mm dia. 0.03-mm dia. 0.26-mm dia. 1.0-mm dia. 0.015-mm dia. 0.015-mm dia. 0.015-mm dia. 0.015-mm dia. 0.2-mm dia. 0.015-mm dia. 0.015-mm dia. 0.03-mm dia. 0.03-mm dia. 1.0-mm dia. 0.015-mm dia. 0.015-mm dia. 0.03-mm dia. 0.03-mm dia. 1.0-mm dia. 0.015-mm dia. 0.015-mm dia. 0.03-mm dia. 0.03-mm dia. 1.0-mm dia. 0.015-mm dia. 0.015-mm dia. 0.03-mm dia. 0.03-mm dia. 0.5-mm dia. Long distance T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: 150 mm (20 x 20 cm) 200 mm (20 x 20 cm) 100 mm (10 x 10 cm) 45 mm (5 x 5 cm) 10 mm (2.5 x 2.5 cm) 80 mm (10 x 10 cm) 120 mm (20 x 20 cm) 60 mm (10 x 10 cm) 15 mm (2.5 x 2.5 cm) 2 mm (2.5 x 2.5 cm) 35 mm (5 x 5 cm) 50 mm (5 x 5 cm) 25 mm (2.5 x 2.5 cm) 11 mm (2.5 x 2.5 cm) 1 mm (2.5 x 2.5 cm) 35 mm (5 x 5 cm) 50 mm (5 x 5 cm) 25 mm (2.5 x 2.5 cm) 11 mm (2.5 x 2.5 cm) 1 mm (2.5 x 2.5 cm) 100 mm (10 x 10 cm) 150 mm (20 x 20 cm) 75 mm (10 x 10 cm) 33 mm (5 x 5 cm) 10 mm (2.5 x 2.5 cm) 100 mm (10 x 10 cm) 150 mm (20 x 20 cm) 75 mm (10 x 10 cm) 33 mm (5 x 5 cm) 10 mm (2.5 x 2.5 cm) 20 mm (2.5 x 2.5 cm) 36 mm (5 x 5 cm) 18 mm (2.5 x 2.5 cm) 8 mm (2.5 x 2.5 cm) 2 mm (2.5 x 2.5 cm) 20 mm (2.5 x 2.5 cm) 36 mm (5 x 5 cm) 18 mm (2.5 x 2.5 cm) 8 mm (2.5 x 2.5 cm) 2 mm (2.5 x 2.5 cm) E32-D12 3 mm dia. Long distance E32-D21L M4 screw Long distance E32-D22L 3 mm dia. Long distance E32-DC200 M6 screw General-purpose E32-DC200B E32-DC200B4 M6 screw General-purpose E32-DC200E M3 screw General-purpose E32-DC200F E32-DC200F4 M3 screw General-purpose E32-D11 M6 screw T: 60 mm (10 x 10 cm) H: 90 mm (10 x 10 cm) A: 45 mm (5 x 5 cm) F 20 mm (2.5 x 2.5 cm) V: 7 mm (2.5 x 2.5 cm) T: 13 mm (10 x 10 cm) H: 20 mm (10 x 10 cm) A: 10 mm (5 x 5 cm) F: 5 mm (2.5 x 2.5 cm) V: --- Flexible (resists breaking) 6 E3X Model Appearance Sensing distance (standard object) (T: E3X-Tjj; H: E3X-H11; A: E3X-Ajj; F: E3X-Fjj; V: E3X-VGjj) White paper E32-D21 M3 screw E3X Min. sensing object (copper wire) Features Black paper T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: 1.6 mm (2.5 x 2.5 cm) 3 mm (2.5 x 2.5 cm) 1.5 mm (2.5 x 2.5 cm) ----6 mm (5 x 5 cm) 10 mm (5 x 5 cm) 4.5 mm (2.5 x 2.5 cm) ----6 mm (5 x 5 cm) 10 mm (5 x 5 cm) 4.5 mm (2.5 x 2.5 cm) ----T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: 0.015-mm dia. 0.015-mm dia. 0.03-mm dia. 0.03-mm dia. 1.0-mm dia. 0.015-mm dia. 0.015-mm dia. 0.03-mm dia. 0.03-mm dia. 1.0-mm dia. 0.015-mm dia. 0.015-mm dia. 0.03-mm dia. 0.03-mm dia. 1.0-mm dia. 0.015-mm dia. 0.015-mm dia. 0.03-mm dia. 0.03-mm dia. 1.0-mm dia. Flexible (resists breaking) T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: 8 mm (2.5 x 2.5 cm) 14 mm (2.5 x 2.5 cm) 7 mm (2.5 x 2.5 cm) 3 mm (2.5 x 2.5 cm) 1 mm (2.5 x 2.5 cm) 30 mm (5 x 5 cm) 44 mm (5 x 5 cm) 22 mm (2.5 x 2.5 cm) 10 mm (2.5 x 2.5 cm) 2.5 mm (2.5 x 2.5 cm) 30 mm (5 x 5 cm) 44 mm (5 x 5 cm) 22 mm (2.5 x 2.5 cm) 10 mm (2.5 x 2.5 cm) 2.5 mm (2.5 x 2.5 cm) E32-DC200C M6 screw ** Flexible spiral cord E32-DC200D E32-DC200D4 M6 screw ** Flexible spiral cord E32-DC9G E32-DC9G4 1.2-mm dia. ** T: 35 mm (5 x 5 cm) H: 60 mm (10 x 10 cm) A: 30 mm (5 x 5 cm) F: 9 mm (2.5 x 2.5 cm) V: 2.5 mm (2.5 x 2.5 cm) T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: 6 mm (2.5 x 2.5 cm) 10 mm (2.5 x 2.5 cm) 5 mm (2.5 x 2.5 cm) 1.8 mm (2.5 x 2.5 cm) --100 mm (10 x 10 cm) 150 mm (20 x 20 cm) 75 mm (10 x 10 cm) 33 mm (5 x 5 cm) 10 mm (2.5 x 2.5 cm) 30 mm (2.5 x 2.5 cm) 40 mm (5 x 5 cm) 20 mm (2.5 x 2.5 cm) 9 mm (2.5 x 2.5 cm) 2.5 mm (2.5 x 2.5 cm) 60 mm (10 x 10 cm) 80 mm (10 x 10 cm) 40 mm (5 x 5 cm) 11 mm (2.5 x 2.5 cm) 4 mm (2.5 x 2.5 cm) T: 7 mm (5 x 5 cm) H: 12 mm (10 x 10 cm) A: 6 mm (5 x 5 cm) F: 1.5 mm (2.5 x 2.5 cm) V: --T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: 1.3 mm (2.5 x 2.5 cm) 2 mm (2.5 x 2.5 cm) ------20 mm (10 x 10 cm) 30 mm (20 x 20 cm) 15 mm (10 x 10 cm) 6 mm (5 x 5 cm) 2 mm (2.5 x 2.5 cm) 5.3 mm (2.5 x 2.5 cm) 8 mm (5 x 5 cm) 4 mm (2.5 x 2.5 cm) 1.5 mm (2.5 x 2.5 cm) --10 mm (10 x 10 cm) 16 mm (10 x 10 cm) 8 mm (5 x 5 cm) 4 mm (2.5 x 2.5 cm) --- Stainless steel sleeve E32-D33 3-mm dia. 0.8-mm dia. T: 0.015-mm dia. H: 0.015-mm dia. A: 0.015-mm dia. F: 0.03-mm dia. V: --T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: 0.015-mm dia. 0.015-mm dia. 0.03-mm dia. 0.03-mm dia. 0.5-mm dia. 0.015-mm dia. 0.015-mm dia. 0.03-mm dia. 0.03-mm dia. 0.5-mm dia. 0.015-mm dia. 0.015-mm dia. 0.04-mm dia. 1.1-mm dia. 1-mm dia. 0.03-mm dia. 0.03-mm dia. 0.03-mm dia. 0.5-mm dia. 1.0-mm dia. 0.03-mm dia. 0.03-mm dia. 0.03-mm dia. 0.03-mm dia. 1.0-mm dia. 0.03-mm dia. 0.03-mm dia. 0.03-mm dia. 0.5-mm dia. 0.5-mm dia. Super-thin; detail sensing E32-CC200 M6 screw Coaxial; positioning accuracy E32-D32 2-mm dia. General-purpose E32-D32L 3-mm dia. General-purpose E32-D14L 6-mm dia. T: 40 mm (5 x 5 cm) H: 40 mm (5 x 5 cm) A: 40 mm (5 x 5 cm) F: 12 mm (2.5 x 2.5 cm) V: 1.5 mm (2.5 x 2.5 cm) T: H: A: F: V: 15 mm (2.5 x 2.5 cm) 15 mm (2.5 x 2.5 cm) 15 mm (2.5 x 2.5 cm) 4 mm (2.5 x 2.5 cm) 1.6 mm (2.5 x 2.5 cm) T: 8 mm (5 x 5 cm) H: 8 mm (5 x 5 cm) A: 8 mm (5 x 5 cm) F: 2 mm (2.5 x 2.5 cm) V: --T: H: A: F: V: 2.5 mm (2.5 x 2.5 cm) 2.5 mm (2.5 x 2.5 cm) 2.5 mm (2.5 x 2.5 cm) ----- Side-view; long distance E32-D24 2-mm dia. Side-view; save space E32-D12F 6-mm dia. T: 50 mm (5 x 5 cm) H: 50 mm (5 x 5 cm) A: 50 mm (5 x 5 cm) F: 20 mm (2.5 x 2.5 cm) V: 4 mm (2.5 x 2.5 cm) T: 15 mm (5 x 5 cm) H: 15 mm (5 x 5 cm) A: 15 mm (5 x 5 cm) F: 6 mm (2.5 x 2.5 cm) V: --- Teflon-covered***; withstands chemicals and harsh environments *Standard object: opaque **Not trimmable ***Teflon is a registered trademark of the Dupont Company and the Mitsui Dupont Chemical Company for their fluoride resin. 7 E3X Model Appearance Sensing distance (standard object) (T: E3X-Tjj; H: E3X-H11; A: E3X-Ajj; F: E3X-Fjj; V: E3X-VGjj) White paper E32-D51 M6 screw E3X Min. sensing object (copper wire) Features Black paper T: H: A: F: V: 12 mm (10 x 10 cm) 24 mm (20 x 20 cm) 12 mm (10 x 10 cm) 5 mm (5 x 5 cm) --T: H: A: F: V: T: H: A: F: V: T: H: A: F: V: 0.03-mm dia. 0.03-mm dia. 0.03-mm dia. 0.03-mm dia. 1.0-mm dia. 0.03-mm dia. 0.03-mm dia. 0.03-mm dia. 0.03-mm dia. 1.0-mm dia. 0.03-mm dia. 0.03-mm dia. 0.03-mm dia. 0.2-mm dia. 1.0-mm dia. Heat-resistive; resists 150°C T: H: A: F: V: ** 60 mm (10 x 10 cm) 120 mm (20 x 20 cm) 60 mm (10 x 10 cm) 26 mm (5 x 5 cm) 5 mm (2.5 x 2.5 cm) E32-D61 M6 screw T: 45 mm (5 x 5 cm) H: 45 mm (5 x 5 cm) A: 45 mm (5 x 5 cm) F: 20 mm (2.5 x 2.5 cm) V: 5 mm (2.5 x 2.5 cm) T: 30 mm (5 x 5 cm) H: 30 mm (5 x 5 cm) A: 30 mm (5 x 5 cm) F: 17 mm (2.5 x 2.5 cm) V: 3 mm (2.5 x 2.5 cm) T: 25 to 250 mm (35-mm dia. min.) H: 10 to 250 mm (35-mm dia. min.) A: 10 to 250 mm (35-mm dia. min.) F: 20 to 230 mm (35-mm dia. min.) V: --T: 150 to 1,500 mm (35-mm dia. min.) H: 150 to 1,500 mm (35-mm dia. min.) A: 150 to 1,500 mm (35-mm dia. min.) F: 50 to 700 mm (35-mm dia. min.) V: --T: H: A: F: V: T: H: A: F: V: 3.3 mm (2.5 x 2.5 cm) 3.3 mm (2.5 x 2.5 cm) 3.3 mm (2.5 x 2.5 cm) 3.3 mm (2.5 x 2.5 cm) --3.3 mm (2.5 x 2.5 cm) 3.3 mm (2.5 x 2.5 cm) 3.3 mm (2.5 x 2.5 cm) 3.3 mm (2.5 x 2.5 cm) --- T: 9 mm (5 x 5 cm) H: 9 mm (5 x 5 cm) A: 9 mm (5 x 5 cm) F: 4 mm (2.5 x 2.5 cm) V: --T: 6 mm (5 x 5 cm) H: 6 mm (5 x 5 cm) A: 6 mm (5 x 5 cm) F: 3 mm (2.5 x 2.5 cm) V: ----- Heat-resistive; resists 300°C E32-D73 ** M4 screw 1.25-mm dia. Heat-resistive; resists 400°C E32-R21 /E39-R3 M6 screw Reflector E39-R3 T: 0.6-mm dia. H: 0.3-mm dia. A: 0.3-mm dia. F: 0.5-mm dia. V: --- Transparent objects sensing E32-R16 /E39-R1 Reflector E39-R1 --- T: 1.9-mm dia. H: 0.6-mm dia. A: 0.6-mm dia. F: 0.6-mm dia. V: --- Transparent objects sensing E32-L25 --- T: 0.015-mm dia. H: 0.015-mm dia. A: 0.03-mm dia. F: 0.5-mm dia. V: --T: 0.015-mm dia. H: 0.015-mm dia. A: 0.03-mm dia. F: 0.5-mm dia. V: --H: 0.015-mm dia. A: 0.015-mm dia. F: 0.015-mm dia. Limited reflective; senses wafers and small difference in height Limited reflective; senses wafers and small difference in height Limited reflective, long distance; senses wafers and small difference in height Limited reflective, long distance, side-view; senses wafers and small difference in height E32-L25A --- E32-L25L H: 7.2±1.8 mm (2.5 x 2.5 cm) A: 7.2±1.8 mm (2.5 x 2.5 cm) F: 7.2±1.0 mm (2.5 x 2.5 cm) H: 4±2 mm (2.5 x 2.5 cm) A: 4±2 mm (2.5 x 2.5 cm) F: 4±2 mm (2.5 x 2.5 cm) --- E32-L24L --- H: 0.015-mm dia. A: 0.015-mm dia. F: 0.015-mm dia. *Standard object: opaque **Not trimmable 8 E3X Fine Through-beam Model E32-T22S 1.7 mm dia. E3X Appearance Sensing distance (standard object)* H: 1,000 mm (1.7-mm dia. min.) T: 650 mm (1.7-mm dia. min.) H: 700 mm (1.7-mm dia. min.) T: 450 mm (1.7-mm dia. min.) Min. sensing object (opaque objects) H: 0.5-mm dia. T: 0.4-mm dia. H: 0.5-mm dia. T: 0.4-mm dia. Features General purpose Side-view E32-T24S 3.5 x 3 mm dia. E32-T84S H: 700 mm (1.7-mm dia. min.) H: 0.4-mm dia. Sensing the wafers in cassettes (Fine, long beam sensor resisting 200°C) *Use the E32-T22S and E32-T24S in combination with the E3X-H11, E3X-T11, or E3X-T21 Amplifier for stable wafer sensing. Slot Sensors Model E32-G14 Appearance Sensing distance (standard object)* 10 mm (slot width) (4-mm dia. min.) T: H: A: F: V: Min. sensing object (opaque objects) 0.7-mm dia. 1.0-mm dia. 0.5-mm dia. 0.6-mm dia. 0.6-mm dia. Features Slot through-beam; no optical axis adjustment required *Standard object: opaque Liquid Level Fiber Unit Liquid Contact Model Model Appearance Standard sensing object Pure water at a temperature of temperature of 25°C. Sensing object angle range ±10° max. Repeat frequency 0.5 mm max. Applicable Amplifier Unit (see note) E3X-NT/NM E3X-NV E3X-NV E3X-H E32-D82F1 E32-D82F2 Note: When using the E32-D82F1 or E82-D82F2 with the E3X-A, cut the plastic fiber part to 0.5 m, otherwise the energy of the light received by the E3X-A will be insufficient. Pipe Mounting Model Model E32-L25T Appearance Standard sensing object Liquid (Non-transparent liquids may not be sensed) Repeat frequency 1 mm max. Applicable Amplifier Unit E3X-NT/NM E3X-A/H 9 E3X High-precision Screen Sensors Model Appearance Slit width Sensing distance (H: E3X-H11; A: E3X-Ajj; F: E3X-Fjj; V: E3X-VGjj) H: A: H: A: H: A: H: A: F: V: H: A: F: V: H: A: F: V: 600 mm 300 mm 100 mm 50 mm 200 mm 100 mm 1,500 mm 750 mm 330 mm 150 mm 900 mm 450 mm 120 mm 20 mm 1,200 mm 600 mm 250 mm 60 mm H: A: H: A: H: A: H: A: F: V: H: A: F: V: H: A: F: V: Min. sensing object* (horizontal beam) 1.3-mm dia. (1.1-mm dia.) 2.0-mm dia. (0.9-mm dia.) 1.3-mm dia. (0.4-mm dia.) 2.0-mm dia. (0.7-mm dia.) 1.3-mm dia. (0.6-mm dia.) 2.0-mm dia. (0.8-mm dia.) 6.0-mm dia. 6.0-mm dia. 7.0-mm dia. 7.0 mm dia. 5.0-mm dia. 5.0-mm dia. 7.0-mm dia. 7.0-mm dia. 6.0-mm dia. 6.0-mm dia. 7.0-mm dia. 7.0-mm dia. E3X E32-T16P Not used 0.5 mm wide 1.0 mm wide E32-T16 Not used 0.5 mm wide 1.0 mm wide * Values not in parentheses represent sensing objects within the 11-mm sensing area and values in parentheses represent sensing objects in the center of the E32-T16P sensing area. The diameters of sensing objects in the above table represent sensing object sizes, on condition that the objects are not moving. Sensing Direction Sensing object Specifications Amplifier Units Indicator Sensitivity adjuster Circuit protection Ambient temperature Ambient humidity Ambient illumination Insulation resistance Dielectric strength Enclosure rating Material Connection method Weight (with 2-m cord) Note: Light indicator (red), Stability indicator (green) 8 turns with indicator (except E3X-Tjj) Reverse polarity, Output short-circuit Operating:–25°C to 55°C (with no icing) Storage: –40°C to 70°C 35% to 85% (with no condensation) Sunlight: 10,000 x max.; Incandescent lamp: 3,000 x max. 20 MW min. (at 500 VDC) 1,000 VAC, 50/60 Hz for 1 min IEC IP66 (with protective cover in place) (see note) Case: Heat-resistive ABS; Cover: Polycarbonate Cord-drawing method Approx. 100 g The enclosure rating is IP50 without the protection cover. 10 E3X Fiber Unit Through-beam (Separate) Sensors Model E32-T11L E32-T12L E32-T21L E32-T22L E32-TC200 E32-TC200B E32-TC200B4 E32-T22 E32-TC200E E32-TC200F E32-TC200F4 E32-TC200A E32-T11 E32-T21 E32-TC200C E32-TC200D E32-TC200D4 E32-T14L E32-T24 E32-T14 E32-T17L E32-T12F E32-M21 E32-T51 E32-T61 Operating: –30°C to 70°C (with no icing) Operating: –40°C to 70°C (with no icing) Operating: –40°C to 150°C* (with no icing) Operating: –40°C to 300°C (with no icing) 40 mm min. 25 mm min. 35 mm min. 25 mm min. Teflon-covered black polyethylene Black polyethylene Fluoride resin SUS 25 mm min. Black polyethylene 4 mm min. Vinyl chloride Ambient temperature O ea g Operating: –40°C to 70°C 0 o0 (with ( ith no i i ) icing) Ambient humidity Operating: 35% to g 85% Permissible bending radius 25 mm min. Material Black polyethylene E3X Enclosure rating IEC IP67 *When used continuously between –40°C and 130°C. 11 E3X Reflective Sensors Model E32-D11L E32-D12 E32-D21L E32-D22L E32-DC200 E32-DC200B E32-DC200B4 E32-DC200E E32-DC200F E32-DC200F4 E32-D11 E32-D21 E32-DC200C E32-DC200D E32-DC200D4 E32-DC9G E32-DC9G4 E32-D33 E32-CC200 E32-D32 E32-D32L E32-D14L E32-D24 E32-D12F Operating: –30°C to 70°C (with no icing) Operating: –40°C to 150°C (with no icing)** Operating: –40°C to 300°C (with no icing) Operating: –40°C to 400°C (with no icing) Operating: –40°C to 70°C (with no icing) Operating: –25°C to 55°C (with no icing) Operating: –40°C to 70°C (with no icing) Operating: –40°C to 105°C (with no icing) icing) 10 mm min. (average at 10% decrease of of sensing distance) Reinforced polyethylene Black polyethylene IEC IP66 40 mm min. Teflon-covered black polyethylene* Fluoride resin 25 mm min. Black polyethylene l th l 4 mm min. Vinyl chloride Differential travel 20% of max. of sensing distance i di t (Adjustable in a in range of 0% to of 0% to 20% when the E3X-H1 is used E3X-H11 is used.) Ambient temperature O ea g Operating: –40°C 0 to 70°C (with no ( ih icing) Ambient humidity Operating: g 35% t 85% to Permissible bending radius 25 mm min. Material Black polyethylene l th l E3X Enclosure rating IEC IP67 E32-D51 35 mm min. E32-D61 25 mm min. SUS E32-D73 E32-R21 E39-R3 E32-R16 E39-R1 E32-L25 E32-L25A E32-L25L*** IEC IP50 E32-L24L*** *Teflon is a registered trademark of the Dupont Company and the Mitsui Dupont Chemical Company for their fluoride resin. **When used continuously between –40°C and 130°C. ***Beam size: 2 mm dia. 12 E3X Fine Through-beam Sensors Model Beam size Differencial travel --Horizontal positioning accuracy --Ambient temperature Operating: –40°C to 70°C to (with no icing) Operating: –40°C to 200°C (with no icing) Ambient humidity Permissible bending radius* Material E3X Enclosure rating IEC IP67 E32-T22S E32-T24S E32-T84S 13 mm dia. (at a distance of distance of 200 mm) Operating: 10 mm min. 35% to 85% 25 mm min. Reinforced laminated laminated vinyl chloride SUS *Average at 30% of sensing distance Slot Sensors Model E32-G14 Ambient temperature Operating: –40°C to 70°C (with no icing) Ambient humidity Operating: 35% to 85% Permissible bending radius 25 mm min. Material Black polyethylene Enclosure rating IEC IP67 Liquid Contact Model Model Differencial travel Ambient temperature Ambient humidity Ambient pressure Permissible bending radius* (average at 10% of sensing distance) 40 mm min. (plastic fiber: 25 mm min.) Bending-prohibited part: E32-D82F1: Within Withi 150 mm of f fiber tip E32-D82F2: Within 350 mm of fiber tip Material Enclosure rating E32-D82F1 3.0 mm max. Teflon part within 1.5 m of fiber tip: –40°C to 200°C (with no icing) Parts other than above: b –40°C to 85°C (with no icing) Operating: 35% to 85% –50 kpa (–0.49 kgf/cm2) to 500 kpa (4.9 kgf/cm2) Sensing head: Teflon* (PFA) Fiber sheath: Black yy polyethylene Connector: Nickel-coated brass IEC IP68** E32-D82F2 *The teflon part located 10 cm underwater must not generate air bubbles when air is injected into the teflon part with a pressure of 98 kpa (1 kgf/cm2). **Teflon is a registered trademark of the Dupont Company and the Mitsui Dupont Chemical Company for their fluoride resin. Pipe Mounting Model Model Suitable pipe Pipe material Ambient temperature Operating: –40°C to 70°C (with no icing) Ambient humidity Operating: 35% to 85% Permissible bending radius 10 mm min. Material Enclosure rating IEC IP50 E32-L25T Transparent pipes with an outer diameter of 8 to 10 mm and an inner diameter of 6 to 8 mm FEP transparent pipes or equivalent Sensing head: Polycarbonate Fiber: Polyethylenecovered plastic High-precision Screen Sensors Model E32-T16P Ambient temperature Operating: –40°C to 70°C (with no icing) Ambient humidity Operating: 35% to 85% Permissible bending radius R10 mm min. Material Sensing head: Heat-resistive ABS Fiber sheath: Vinyl chloride Sensing head: Heat-resistive ABS Sensing surface: PMMA Fiber sheath: Black polyethylene Enclosure rating IEC IP50 E32-T16 25 mm min. IEC IP67 13 E3X Attachments Name Applications Model Appearance Applicable fibers With E3X-Tjj With E3X-H11 With E3X-Ajj With E3X-Fjj With E3X-VGjj Directivity Differential travel Ambient temperature Material Shaft Lens Base Reflector *E32-T6: 450 mm. **E32-T6: 130 mm. Name Applications Model Appearance Applicable fibers With E3X-Tjj With E3X-H11 With E3X-Ajj With E3X-Fjj With E3X-VGjj Directivity Differential travel Ambient temperature Material Shaft Lens Base Reflector Sensing distance Standard object Sensing distance Standard object Sensing distance Standard object Sensing distance Standard object Sensing distance Standard object E32-T11L 250 mm 400 mm 200 mm 60 mm 10 mm Opaque objects: 4-mm dia. min. 20° to 60° --Operating: –40°C to 200°C (Do not exceed the operating temperature of the fiber.) Brass Optical glass ----E39-F2 Through-beam (separate) E3X Small Spot Lens Unit Sensing over 0.5-mm-dia. spots E39-F3A Reflective Long Distance Lens Unit Increasing sensing distance E39-F1 Through-beam (separate) E32-D32 20 mm White paper 2.5 x 2.5 cm 20 mm White paper 2.5 x 2.5 cm 20 mm White paper 2.5 x 2.5 cm 16 mm White paper 2.5 x 2.5 cm ------20% of sensing distance Operating: –40°C to 70°C Aluminum Optical glass ----- E32-T11L 1,200 mm 2,000 mm 1,000 mm 550 mm 120 mm 5° to 40° --- E32-TC200 E32-T61 2,000 mm 3,000 mm 1,500 mm 670 mm* 190 mm** E32-T11 1,300 mm 2,000 mm 1,000 mm 400 mm 120 mm E32-TC200C 800 mm 1,600 mm 800 mm 350 mm 100 mm Sensing distance Standard object Sensing distance Standard object Sensing distance Standard object Sensing distance Standard object Sensing distance Standard object Opaque objects: 4-mm dia. min. Opaque objects: 4-mm dia. min. Opaque objects: 4-mm dia. min. Opaque objects: 4-mm dia. min. Opaque objects: 4-mm dia. min. Operating: –40°C to 200°C (Do not exceed the operating temperature of the fiber.) Brass Side-view Unit Changing the sensing direction at °90 E32-TC200 250 mm 500 mm 250 mm 100 mm 19 mm E32-T61/11 200 mm 400 mm 200 mm 60 mm 10 mm E32-TC200C 100 mm 200 mm 100 mm 30 mm 6 mm Opaque objects: 3-mm dia. min. Opaque objects: 3-mm dia. min. Opaque objects: 3-mm dia. min. Opaque objects: 3-mm dia. min. Opaque objects: 3-mm dia. min. 14 E3X Name Applications Model Appearance Reflective E3X Lens-equipped Reflective Unit Converting through-beam sensors to reflective sensors E39-F3 Applicable fibers With E3X-Tjj With E3X-H11 With E3X-Ajj With E3X-Fjj With E3X-VGjj Directivity Differential travel Ambient temperature Material Shaft Lens Base Reflector Sensing distance (standard object) Sensing distance (standard object) Sensing distance (standard object) Sensing distance (standard object) Sensing distance (standard object) White paper Black paper White paper Black paper White paper Black paper White paper Black paper White paper Black paper E32-T11L 55 to 150* mm (20 x 20 cm) --10 to 300 mm (20 x 20 cm) --10 to 150 mm (20 x 20 cm) --10 to 65 mm (10 x 10 cm) --------20% of sensing distance E32-TC200 85 to 100 mm (20 x 20* cm) 15 to 17*mm (20 x 20 cm) 35 to 180 mm (20 x 20 cm) 5 to 120 mm (20 x 20 cm) 35 to 90 mm (10 x 10 cm) 5 to 60 mm (10 x 10 cm) 20 to 40 mm (5 x 5 cm) 10 to 20 mm (5 x 5 cm) 10 to 15 mm (2.5 x 2.5 cm) E32-T61 16 to 18*mm (20 x 20 cm) 5 to 80 mm (20 x 20 cm) 5 to 40 mm (10 x 10 cm) 20 to 35 mm (5 x 5 cm) ----- Operating: –40°C to 200°C (Do not exceed the operating temperature of the fiber.) Brass Optical glass Aluminum --- *These values are possible when the angle of the E39-F3 is smallest (parallel). 15 E3X Name Applications Lens-equipped Reflective Unit Converting through-beam sensors to reflective sensors E39-F3 Reflective E3X Side-view Reflective Unit Converting through-beam to reflective sensor E39-F5 Reflective Model Appearance Applicable fibers With E3X-Tjj With E3X-H11 With E3X-Ajj With E3X-Fjj With E3X-VGjj Directivity Differential travel Ambient temperature Material Shaft Lens Base Reflector Sensing distance (standard object) Sensing distance (standard object) Sensing distance (standard object) Sensing distance (standard object) Sensing distance (standard object) White paper Black paper White paper Black paper White paper Black paper White paper Black paper White paper Black paper E32-T11 90 to 100* mm (20 x 20 cm) --35 to 180 mm (20 x 20 cm) 5 to 70 mm (20 x 20 cm) 35 to 90 mm (10 x 10 cm) 5 to 35 mm (10 x 10 cm) 20 to 40 mm (5 x 5 cm) --------20% of sensing distance E32-TC200C 85 to 100* mm (20 x 20 cm) E32-TC200A 5 to 30* mm (10 x 10 cm) 6 to 9* mm (10 x 10 cm) 60 mm (10 x 10 cm) 10 to 60 mm (20 x 20 cm) 10 to 30 mm (10 x 10 cm) 20 to 35 mm (5 x 5 cm) 5 to 20 mm (10 x 10 cm) 30 mm (5 x 5 cm) 5 to 10 mm (5 x 5 cm) 13 mm (2.5 x 2.5 cm) ----- Operating: –40°C to 200°C (Do not exceed the operating temperature of the fiber.) Brass Optical glass Aluminum --- Operating: –40°C to 70°C ----Brass Stainless *These values are possible when the angle of the E39-F3 is smallest (parallel). Beam Spot Characteristics E39-F3A d Fiber E32-D32 O: Spot diameter (mm) 1.5 1.0 : Insertion distance d: Focal length Focal length d (mm) 0.8 0.5 Insertion distance (mm) 16 E3X Spiral Tubes Model Appearance E39-F32A5 E39-F32A E39-F32B5 E39-F32B L E3X E39-F32C5 E39-F32C E39-F32D5 E39-F32D End cap Tube Head connector Length (L) Applicable fiber 500 mm 1,000 mm 500 mm 1,000 mm 500 mm 1,000 mm 500 mm 1,000 mm E32-DC200E E32-DC200F(4) E32-D21 E32-TC200E E32-TC200F(4) E32-T21 E32-T21L E32-TC200 E32-TC200B(4) E32-T11 E32-T51 E32-T11L E32-DC200 E32-DC200B(4) E32-CC200 E32-D11 E32-D51 E32-D11L Ambient temperature Ambient humidity Permissible bending radius Tensile strength Compression load Operating: –40°C to 150°C (Do not exceed the operating temperature of the fiber) Operating: 35% to 85% R: 30 mm min. Between head connector and end cap with tube: 15 kgf $ cm max. (1.5 N $ m) Tube: 20 kgf $ cm max. (2 N $ m) Tube: 3 kg max. (29.4 N) Accessories Name Model Appearance Fiber Cutter E39-F4 Fine-fiber Attachment E39-F9 Fiber Connector E39-F10 Sleeve Bender E39-F11 Features Applicable fiber Used to cut fibers to desired lengths All models equipped with trimmable fibers Used when inserting fine fibers into the amp E32-DC200E, -TC200E E32-DC200F(4), -TC200F(4) E32-D21, -D21L, -D22L E32-T21, -T21L, -T22L E32-D32, -T22 E32-D24. -T24 E32-D33 E32-R21 Used to connect fibers when broken E32-DC200, -TC200 E32-DC200B(4), -TC200B(4) E32-TC200A E32-T14, -G14 E32-D11L, -T11L, -T12L E32-D14L, -T14L E32-T17L Used to bend fiber sleeves E32-TC200B(4) E32-TC200D(4) E32-DC200F(4), -TC200F(4) E32-DC9G(4) 17 E3X E3X Engineering Data Excess Gain Ratio E3X-Tjj E32-TC200 Sensing distance E32-T11L Sensing distance E32-T11L + E39-F1 Sensing distance Excess gain ratio Sensing distance (mm) Excess gain ratio Sensing distance (mm) Excess gain ratio Sensing distance (m) E32-T11L + E39-F2 E32-T11L + E39-F3 (When the angle of the E39-F3 is at its minimum (parallel).) Sensing distance Sensing object E32-T21L Sensing distance Excess gain ratio Excess gain ratio Sensing distance Sensing distance (mm) Sensing distance (mm) Excess gain ratio Sensing distance (mm) E32-T14L Sensing distance E32-T17L Sensing distance E32-T16 Sensing distance Excess gain ratio Sensing distance (mm) Excess gain ratio Sensing distance (m) Excess gain ratio Sensing distance (m) 18 E3X E32-DC200 Sensing distance E3X E32-D11L Sensing distance E32-D21L Sensing distance Excess gain ratio Sensing distance (mm) Excess gain ratio Sensing distance (mm) Excess gain ratio Sensing object Sensing object Sensing object Sensing distance (mm) E3X-H11 E32-TC200 Sensing distance E32-TC200 + E39-F1 Sensing distance E32-T11L Sensing distance Excess gain ratio Sensing distance (mm) Excess gain ratio Sensing distance (m) Excess gain ratio Sensing distance (mm) E32-T11L + E39-F1 Sensing distance E32-T11L + E39-F2 Sensing distance E32-T11L + E39-F3 Sensing object Excess gain ratio Excess gain ratio Sensing distance (m) Excess gain ratio Sensing distance Sensing distance (mm) Sensing distance (mm) 19 E3X E32-T21L Sensing distance E3X E32-T14L Sensing distance E32-T17L Sensing distance Excess gain ratio Sensing distance (mm) Excess gain ratio Sensing distance (mm) Excess gain ratio Sensing distance (m) E32-T16 Sensing distance E32-T22S Sensing distance E32-T24S Sensing distance Excess gain ratio Excess gain ratio Sensing distance (m) Sensing distance (mm) Excess gain ratio Sensing distance (mm) E32-DC200 Sensing distance E32-D11L Sensing distance E32-D21L Sensing distance Excess gain ratio Excess gain ratio Sensing distance (mm) Sensing distance (mm) Excess gain ratio Sensing object Sensing object Sensing distance (mm) 20 E3X E32-T84S Sensing distance E3X Excess gain ratio Sensing distance (mm) E3X-Ajj/-Fjj/-VGjj E32-T11L, E32-T12L Sensing distance E32-T11L + E39-F1 Sensing distance E32-T11L + E39-F2 Sensing distance Excess gain ratio Excess gain ratio Excess gain ratio E3X-Aj E3X-Fj Operating level E3X-Aj E3X-Aj E3X-Fj E3X-Fj E3X-VGj Operating level E3X-VGj E3X-VGj Operating level Sensing distance (mm) Sensing distance (cm) Sensing distance (mm) E32-T11L + E39-F3 Sensing object E32-T21L, E32-T22L Sensing distance E32-T14L Sensing distance Excess gain ratio Sensing distance E3X-Aj Excess gain ratio E3X-Aj E3X-Fj Excess gain ratio E3X-Aj E3X-Fj E3X-Fj Operating level E3X-VGj Operating level E3X-VGj Operating level Sensing distance (mm) Sensing distance (mm) Sensing distance (mm) 21 E3X E32-T17L Sensing distance E3X E32-T12F Sensing distance E32-D11L Sensing distance Excess gain ratio E3X-Aj E3X-Fj Excess gain ratio E3X-Aj E3X-Fj Excess gain ratio Sensing object E3X-Aj E3X-Fj E3X-VGj Operating level E3X-VGj Operating level E3X-VGj Operating level Sensing distance (m) Sensing distance (cm) Sensing distance (mm) E32-D21L, E32-D22L Sensing distance E32-D14L Sensing distance E32-D12F Sensing distance Sensing object Sensing object Excess gain ratio Excess gain ratio E3X-Aj E3X-Fj Operating level E3X-VGj E3X-Aj E3X-Fj Operating level E3X-VGj Excess gain ratio Sensing object E3X-Aj E3X-Fj Operating level E3X-VGj Sensing distance (mm) Sensing distance (mm) Sensing distance (mm) Operating Range E3X-Tjj E32-DC200 Operating position Y (mm) X Y E32-D11L Operating position Y (mm) X Y Set distance X (mm) Set distance X (mm) E32-D21L Operating position Y (mm) X Y Set distance X (mm) 22 E3X E3X-H11 E32-T11L + E39-F3 Operating position Y (mm) E3X E32-DC200 Operating position Y (mm) E32-D11L Operating position Y (mm) Set distance X (mm) Set distance X (mm) Set distance X (mm) Sensing object Sensing object Sensing object E32-D12 Operating position Y (mm) E32-D21L Operating position Y (mm) E32-DC200E Operating position Y (mm) Set distance X (mm) Set distance X (mm) Set distance X (mm) Sensing object Sensing object Sensing object E32-D21 Operating position Y (mm) E32-D11 Operating position Y (mm) E32-CC200 Operating position Y (mm) Set distance X (mm) Set distance X (mm) Set distance X (mm) Sensing object Sensing object Sensing object E32-D32 Operating position Y (mm) E32-D32L Operating position Y (mm) E32-D33 Operating position Y (mm) Set distance X (mm) Set distance X (mm) Set distance X (mm) E32-D51 Operating position Y (mm) E32-L25L Operating position Y (mm) E32-T84S Operating position Y (mm) Set distance X (mm) Set distance X (mm) Operating position Y Sensing object Sensing object Set distance X Set distance X (mm) Sensing object Set distance X 23 E3X E3X-Ajj/-Fjj/-VGjj E32-T11L + E39-F3 Operating position Y (mm) E3X-Fj E3X-Aj E3X E32-DC200 Operating position Y (mm) E32-D11L Operating position Y (mm) E3X-VGj E3X-Aj E3X-Aj E3X-Fj Set distance X (mm) E3X-Fj Set distance X (mm) Set distance X (mm) Sensing object Sensing object Sensing object Note: With E3X-A: Adjust the angle of E39-F3 so that the sensor can sense an object at a distance of 90 mm. (For E3X-F: 50 mm) E32-D12 Operating position Y (mm) E32-D21L + E32-D22L Operating position Y (mm) E32-DC200E Operating position Y (mm) E3X-VGj Amplifier E3X-Aj Amplifier E3X-Fj E3X-Aj E3X-Aj E3X-Fj Amplifier Set distance X (mm) Set distance X (mm) Set distance X (mm) Sensing object Sensing object Sensing object E32-D21 Operating position Y (mm) E3X-VGj E3X-Fj E32-D11 Operating position Y (mm) E32-D33 Operating position Y (mm) E3X-Aj E3X-Aj E3X-Aj Set distance X (mm) Set distance X (mm) Set distance X (mm) Sensing object Sensing object E32-CC200 Operating position Y (mm) E32-D32L Operating position Y (mm) E32-D14L Operating position Y (mm) E3X-VGj E3X-Aj E3X-Fj E3X-Fj E3X-Aj E3X-VGj Amplifier E3X-Fj Amplifier E3X-Aj Amplifier Set distance X (mm) Set distance X (mm) Set distance X (mm) Sensing object 24 E3X E32-D24 Operating position Y (mm) E3X E32-D12F E3X-VGj E3X-Fj E3X-Aj E32-D51 E3X-Fj E3X-Aj Operating position Y (mm) E3X-Fj E3X-Aj Operating position Y (mm) Set distance X (mm) Set distance X (mm) Set distance X (mm) Sensing object Sensing object E32-D61 Operating position Y (mm) E3X-Fj E32-D73 Operating position Y (mm) E32-R16 Operating position Y (mm) E3X-Aj E3X-Aj E3X-Fj E3X-Aj Set distance X (mm) Set distance X (mm) Set distance X (mm) Sensing object Sensing object Sensing object E32-L25L Operating position Y (mm) Set distance X (mm) Operating Sensing object position Y Sensing object Set distance X Set distance X 25 E3X Parallel Operating Range (Typical) E3X-Tjj E32-TC200 Parallel operating range Y (mm) X Y E3X E32-T11L Parallel operating range Y (mm) X Y Set distance X (mm) Set distance X (mm) E32-T11L +E39-F1 Parallel operating range Y (cm) X Y E32-T11L + E39-F2 Parallel operating range Y (mm) X Y Set distance X (m) Set distance X (mm) E32-T21L Parallel operating range Y (mm) X Y E32-T14L Parallel operating range Y (mm) X Y Set distance X (mm) Set distance X (mm) E32-T17L Parallel operating range Y (cm) X Y E32-T12F Parallel operating range Y (cm) X Y Set distance X (m) Set distance X (m) 26 E3X E3X-H11 E32-TC200 Operating position Y (mm) E3X E32-TC200 + E39-F2 Operating position Y (mm) E32-T11L Operating position Y (mm) Set distance X (mm) Set distance X (mm) Set distance X (mm) E32-T11L + E39-F1 Operating position Y (mm) E32-T11L + E39-F2 Operating position Y (mm) E32-T21L Operating position Y (mm) Set distance X (mm) Set distance X (mm) Set distance X (mm) E32-T21L Operating position Y (mm) E32-T22 Operating position Y (mm) E32-T11 Operating position Y (mm) Set distance X (mm) Set distance X (mm) Set distance X (mm) E32-T21 Operating position Y (mm) E32-T14L Operating position Y (mm) E32-T24 Operating position Y (mm) Set distance X (mm) Set distance X (mm) Set distance X (mm) E32-T14 Operating position Y (mm) E32-T17L E32-T12F Operating position Y (mm) Set distance X (mm) Set distance X (mm) Operating position Y (mm) Set distance X (mm) 27 E3X E32-M21 Operating position Y (mm) E3X E32-T51 Operating position Y (mm) E32-T61 Operating position Y (mm) Set distance X (mm) Set distance X (mm) Set distance X (mm) E32-T22S Operating position Y (mm) E32-T24S Operating position Y (mm) Set distance X (mm) Set distance X (mm) E3X-Ajj/-Fjj/-VGjj E32-TC200 Operating position Y (mm) E3X-VGj E3X-Fj E3X-Aj E32-TC200 + E39-F2 Operating position Y (mm) E3X-Aj E32-T11L/-T12L Operating position Y (mm) E3X-VGj E3X-Fj E3X-Aj Set distance X (mm) Set distance X (mm) Set distance X (mm) E32-T11L + E39-F1 Operating position Y (mm) E3X-VGj E3X-Fj E3X-Aj E32-T11L + E39-F2 E3X-VGj E3X-Aj E32-T21L/-T22L E3X-Aj Operating position Y (mm) E3X-Fj Operating position Y (mm) E3X-VGj E3X-Fj Set distance X (mm) Set distance X (mm) Set distance X (mm) 28 E3X E32-TC200E E3X-VGj E3X-Aj E3X E32-T11 E3X-VGj E3X-Aj E32-T21 E3X-Aj Operating position Y (mm) Operating position Y (mm) Operating position Y (mm) E3X-Fj E3X-Fj E3X-Fj Set distance X (mm) Set distance X (mm) Set distance X (mm) E32-T14L Operating position Y (mm) E3X-VGj E3X-Fj E3X-Aj E32-T24 E3X-VGj E3X-Aj E32-T14 Operating position Y (mm) E3X-Fj E3X-Aj Operating position Y (mm) Set distance X (mm) Set distance X (mm) Set distance X (mm) E32-T17L E3X-Aj E32-T12F E3X-Aj E32-M21 E3X-Aj Operating position Y (mm) Operating position Y (mm) E3X-VGj E3X-Fj E3X-VGj E3X-Fj Operating position Y (mm) E3X-F21 Set distance X (mm) Set distance X (mm) Set distance X (mm) E32-T51 E3X-Aj E32-T61 E3X-Aj E32-T61 + E39-F1 E3X-Aj Operating position Y (mm) Operating position Y (mm) E3X-Fj Set distance X (mm) Operating position Y (mm) Set distance X (mm) Set distance X (mm) E32-T22S Operating position Y (mm) E3X-VGj E3X-Fj Set distance X (mm) E32-T24S E3X-Aj Operating position Y (mm) E3X-Aj E3X-VGj E3X-Fj Set distance X (mm) 29 E3X Number of Turns of Sensitivity Adjuster and Sensing Distance (Typical) E3X-H/E32-D11L Sensing Object: White Paper of 5 x 5 cm E3X E3X-A, -F/E32-D11L Sensing Object: White Paper of 10 x 10 cm with E3X-A and 5 x 5 cm with E3X-F Sensing distance (mm) Sensing distance (mm) E3X-Aj E3X-Fj Sensitivity adjuster Sensitivity adjuster Color Sensing (Typical) Green Light Source E3X-VGj /E32-D11L The following graph shows the relationship between colors and the number of turns of the sensitivity adjustor when the E32-D11L is in operation with the sensing distance adjusted to 5 mm. Munsell chroma (MC) White CM484 Yellow CM124 Amber CM 78 Yellow green CM157 Orange CM 85 Aqua CM263 Red CM 6 Purple CM379 Magenta CM431 Blue CM336 Green CM241 Black CM489 5 mm 10° Color paper (2.5 x 2.5 cm) Number of turns 30 E3X E3X Nomenclature E3X-Tjj E3X-H11 Stable Operation Indicator (Green Indicator) Tuning Indicator (Two Colors: red/green indicator) Tuning Button Light Reception Indicator (Red Indicator) Stable Operation Indicator (Green Indicator) Sensitivity Indicator The position of the indicator can be checked. 8-turn Sensitivity Adjuster Light Reception Indicator (Red Indicator) Mode Setting Selector Timer Switch ON: Timer function is ON. OFF: Timer function is OFF. Hysteresis Adjuster Timer Switch ON: Timer function is ON. OFF: Timer function is OFF. Operation Mode Selector L-ON: Output transistor is ON when light is received. D-ON: Output transistor is ON when light is not received. Mode Selector SET: The light source flashes. Set to this mode to adjust the light axis. Light Reception L-ON: Output transistor is ON Monitoring Terminal when light is received. (see note) D-ON: Output transistor is ON Monitoring is used when light is not rewith the E39-VX ceived. Beam Checker Light Reception Monitoring Terminal Monitoring is used with the E39-VX Beam Checker Note: The light reception monitoring terminal is not available with the E3X-T11. E3X-A11/-A41 E3X-VG11 E3X-A21/-A51 E3X-F21/-F51 E3X-VG21 Light Reception Indicator (Red Indicator) Sensitivity Indicator Sensitivity adjustment can be checked visually. Stable Operation Indicator (Green Indicator) Sensitivity Indicator Light Reception Indicator (Red Indicator) Stable Operation Indicator (Green Indicator) 8-turn Sensitivity Adjuster 8-turn Sensitivity Adjuster Timer Adjuster Timer Switch ON: Timer function is ON. OFF: Timer function is OFF. Mode Selector Light Reception SET: The light source Monitoring Terminal flashes. Set to this Monitoring is used mode to adjust the with the E39-VX light axis. Beam Checker L-ON: Output transistor is ON when light is received. D-ON: Output transistor is ON when light is not received. Note: Set the mode selector to L-ON or D-ON after the light axis is adjusted. Mode Selector SET: The light source flashes. Set to this mode to adjust the light axis. L-ON: Output transistor is ON when light is received. D-ON: Output transistor is ON when light is not received. Light Reception Monitoring Terminal Monitoring is used with the E39-VX Beam Checker 31 E3X E3X Operation Output Circuits Type NPN Model E3X-T21 Mode switch Light ON Output transistor ON when light is received. Light (red) Stability (green) Output circuit Tuning (red/ green) Brown Black Load Main circuit ZD Load Orange Control output ZD Blue Remote tuning input Remote bank selection input ZD : VZ = 39 V Self-diagnostis Self diagnostis tt output Dark ON ON when light is not received. Pink Purple E3X-T11 E3x-H11 E3X-A11 E3X-VG11 Light ON ON when light is received. Light (red) Brown Stability (green) Load Main circuit Black 100 mA max. ZD Blue ZD : VZ = 39 V Dark ON ON when light is not received. ON when light is received. E3X-A21 E3X-VG21 E3X-F21 Light ON Light (red) Stability (green) Brown Load (Relay) Main circuit Black ZD Control output Load (Relay) Dark ON ON when light is not received. g Orange Orange Self-diagnosis output ZD 10 K Pink Externalcheck input Blue ZD : VZ = 39 V PNP E3X-A41 Light ON ON when light is received. Light (red) Stability (green) ZD Main circuit Brown Black 100 mA max. Load Blue ZD : VZ = 39 V Dark ON ON when light is not received. E3X-A51 E3X-F51 Light ON ON when light is received. Light (red) Stability (green) 10 K ZD Orange Brown Pink External-check input Self-diagnosis output Dark ON ON when light is not received. Main circuit ZD Black Control output Load (Relay) Blue ZD : VZ = 39 V Load (Relay) 32 E3X Timing Charts Type NPN Model E3X-T21 Mode switch Light ON Output transistor ON when light is received. Light received Light not received Light indicator ON OFF (Red) Output transistor Load (relay) ON OFF Operate Release (Between brown and black) E3X Timing chart T Dark ON ON when light is not received. Light received Light not received Light indicator ON OFF (Red) Output transistor Load (relay) ON OFF Operate Release T (Between brown and black) E3X-T11 E3X-H11 E3X-A11 E3X-VG11 Light ON ON when light is received. Light received Light not received Light indicator ON OFF (Red) Output transistor Load (relay) ON OFF Operate Release (Between brown and black) Dark ON ON when light is not received. Light received Light not received Light indicator ON OFF (Red) Output transistor Load (relay) ON OFF Operate Release T (Between brown and black) E3X-A21 E3X-VG21 E3X-F21 Light ON ON when light is received. Light received Light not received Light indicator ON OFF (Red) Output transistor Load (relay) ON OFF Operate Release (Between brown and black) Dark ON ON when light is not received. Light received Light not received Light indicator ON OFF (Red) Output transistor Load (relay) ON OFF Operate Release T (Between brown and black) 33 E3X Type PNP Model E3X-A41 Mode switch Light ON Output transistor ON when light is received. Light received Light not received Light indicator ON OFF (Red) Output transistor Load (relay) ON OFF Operate Release (Between blue and black) E3X Timing chart Dark ON ON when light is not received. Light received Light not received Light indicator ON OFF (Red) Output transistor Load (relay) ON OFF Operate Release (Between blue and black) E3X-A51 E3X-F51 Light ON ON when light is received. Light received Light not received Light indicator ON OFF (Red) Output transistor Load (relay) ON OFF Operate Release T (Between blue and black) Dark ON ON when light is not received. Light received Light not received Light indicator ON OFF (Red) Output transistor Load (relay) ON OFF Operate Release T (Between blue and black) 34 E3X E3X-Tjj E3X Sensitivity Adjustment 1. Locate the sensor head in the sensing range of the E3X. 2. Set the mode selector to TUNING. 3. Locate the object at the sensing position and press the tuning button. Through-beam Model Reflective Model Reflective Model Mark Light is not received. Base The tuning indicator (red) is lit. The built-in buzzer beeps once. 4. Move the object and press the tuning button. Through-beam Model Reflective Model Reflective Model Mark Light is received.. Base If tuning is OK: The tuning indicator turns green. The built-in buzzer beeps once. If tuning is NG: The tuning indicator (red) is still lit. The built-in buzzer beeps 3 times. Change the position of the object and the sensing distance that have been set and repeat from the beginning. 5. Set the mode setting selector to RUN to complete the sensitivity setting on the E3X. The tuning indicator (green) is OFF. 6. Select the logical output required with the operation mode selector. Maximum Sensitivity Setting 1. Set the mode setting selector to TUNING. 2. Press the tuning button, at which time the object may or may not be located at the sensing position. The tuning indicator (red) is lit. The built-in buzzer beeps once. 3. Set the mode setting selector to RUN to complete the maximum sensitivity setting on the E3X. It will take approximately three seconds for the stable operation indicator or light reception indicator to be lit. After the maximum sensitivity setting is completed, the tuning indicator will turn green and then it will be automatically turned OFF in approximately three seconds. The maximum sensitivity of the E3X can be automatically set regardless of the set distance or light reception. Note: The sensitivity of the E3X-T11 and E3X-T21 are set to maximum before shipping. 35 E3X E3X-H11/-Ajj/-Fjj/-VGjj Using a sensing object, adjust Sensitivity Adjustor so that the indicators operate as described in the following table: Sensing method Through-beam With sensing object E3X Sensing Light Interrupted Indicators Green: Light ON Red: Light OFF Incident Without sensing object Green: Light ON Red: Light ON Reflective Sensing With sensing object Incident Green: Light ON Red: Light ON Without sensing object Interrupted Green: Light ON Red: Light OFF Sensing of the difference in color or shade Incident Color that has a high reflection ratio Green: Light ON Red: Light ON Interrupted Color that has a low reflection ratio Green: Light ON Red: Light OFF Retroreflective With sensing object Reflector Interrupted Green: Light ON Red: Light OFF Incident Without sensing object Reflector Green: Light ON Red: Light ON Note: 1. If the indicators operate as described in the table, the E3X can operate in stable condition within the rated temperature range. 2. Even when the green indicator is OFF, the E3X will operate stably if the operating temperature change since the initial settings is within +10°C. 36 Light Axis Adjustment with Flashing Function E3X-Tjj This function enables the user to adjust with ease the light axis of the through-beam fiber with the light source flashing. All E3X models have this function. 1. Set the mode setting selector to FLASH. 2. If the axis of the light emission fiber head and that of the light reception fiber head do not agree with each other and the amount of light reception becomes 90% of the peak value or less, the flashing function of the E3X will work. The E3X retains the peak value when the mode setting selector is set to FLASH and the axes of the fiber heads are adjusted to agree with each other. θ Mode Setting Selector Fiber for light emission Fiber for light reception Optical input The peak of light reception 90% of the peak value Lit in this range. Angle of the head (θ) Flashing Lit Flashing E3X-Ajj/-Fjj/-VGjj 1. Set the mode selector to SET. 2. Adjust the light axis by moving the fiber with the light flashing. Improper Light Axis Proper Light Axis Flashing Light ON with no flushing Light axis adjusted Mode Selector 3. Set the mode selector to L-ON or D-ON after the light axis is adjusted. 31 7 E3X Self-diagnostic Function With this function, the E3X checks changes in environmental conditions (especially a change in the ambient temperature) and self-diagnoses the resistance against the changes. The result is shown by the indicators or an output signal. Stable Operation Indicator (Green Indicator) Light Reception Indicator (Red Indicator) Displays E3X • Stable Operation Indicator: Changes in environmental conditions (changes in the ambient temperature, the operating voltage, or the volume of dust) are checked and the resistance against them are self-diagnosed. The result is shown via the indicator. Light Reception Indicator: The amount of light received is indicated by this indicator. The resistance against changes in environmental conditions is indicated by the indicator and the result is output. • • Output Amount of light 1.2 1 0.8 Operating level x 1.2 Operating level Operating level x 0.8 Control output (L-ON) ON OFF 0.3 s min. 0.3 s min. ON Self-diagnostic output* OFF Indicator Tip of the fiber connected to the light source side in the SET mode *If the self-diagnostic output is ON when the sensing object is moving at low speed, use the E3X with an ON-delay timer circuit. Remote Tuning/Remote Bank Function (E3X-T21) Remote Tuning Function Basically, the method of remote tuning is same as that of sensitivity adjustment. When the remote tuning function of the E3X is used, the E3X is tuned with the remote tuning input signal instead of the tuning button which has to be pressed. 1. Set the mode selector to RUN. 2. The following signal conditions must be given as remote tuning input conditions. Brown +V Black; control output Orange; self-diagnostis output Purple; remote bank selection Pink Blue 0 V If no remote tuning is done, cut off the purple wire at its source or connect the pink wire to the positive terminal of the power supply. 2 38 ÉÉÉÉÉ ÈÈÈ ÉÉÉÉÉ ÈÈ ÈÈÈÈ ÈÈÈ ÍÍÍÍÍ ÈÈÈÈ ÍÍÍÍÍ ÈÈ Red Green Green Green Flashing light ON Flashing E3X Power supply ON OFF E3X Remote tuning input Sensitivity setting H L T1 T2 T1 T1: 0.5 to 3 s T2: 0.5 to 1 s min. T2 Maximum sensitivity H L T2: 5 s min. Remote Bank Function The remote bank input signal allows the setting of two kinds of sensitivity adjustment values. Brown +V Black; control output Orange; self-diagnosis input Pink Purple Bank 1: SW = OFF Bank 2: SW = ON Blue 0 V To set two kinds of sensitivity adjustment values, the purple and blue wires must be connected with each other and select bank 2 to tune the E3X. Variable Hysteresis Function (E3X-H11) Sensing of Plate Level Differences (If sensing is impossible with the hysteresis value set to maximum) Reflection of light Reflection of light Reflection of light Refer to the following when using the hysteresis adjuster. ON Large hysteresis differential OFF ON Small hysteresis differential ON OFF OFF A ON B Unstable A Unstable B OFF A ON B OFF Sensing operation is not stable because zone B is within the hysteresis differential range. Reduce the sensitivity of the E3X with the sensitivity adjuster and turn off zone B. Reduce the hysteresis value with the hysteresis adjuster so that zone A will be ON. 3 39 E3X Set both the sensitivity adjuster and hysteresis adjuster to maximum. 12 SENS min max E3X min max Hysteresis differential adjuster Sensitivity adjuster Decide the position of the fiber head and that of the sensing object in zone A. (E) Locate the head in zone A and turn the sensitivity adjuster counterclockwise slowly until the stable operation indicator and light reception indicator are OFF (i.e., position E as shown in the illustration). 12 SENS min max When the head is located in zone B, light reception indicator is lit. YES NO S L Locate the head in zone B and turn the hysteresis adjuster counterclockwise slowly and make sure that the light reception indicator is lit. YES min max NO Set the hysteresis adjuster to maximum. min max S L S L S L (H) min max Set the hysteresis adjuster to the point where the light reception indicator is lit (i.e., position E as shown in the illustration). Locate the head in zone A and turn the sensitivity adjuster clockwise until the stable operation indicator and light reception indicator are OFF (i.e., position F as shown in the illustration). (F) (G) 12 SENS min max (E) The light reception indicator is lit when the head is located in zone B and the light reception indicator is OFF when the head is located in zone A. NO S L Locate the head in zone A and turn the sensitivity adjuster counterclockwise until the light reception indicator and stable operation indicator are OFF (i.e., position O as shown in the illustration). (G) 12 SENS min max YES Sensing is possible. S L B A 4 40 E3X External Diagnostic Input Function With this function, light projection can be stopped when desired. The operation of the sensor can be checked with this function before the E3X is placed into actual operation. E3X-Ajj Light is emitted from the projection fiber head when the self-diagnostic input is ON. The sensor, however, will not operate. NPN Type Brown (+V) Pink (externalcheck Input) ON Indicator Blue (0 V) Brown (+V) Pink (externalcheck Input) OFF Blue (0 V) External-diagnostic input (between blue and pink) LED for light projection Short Open ON OFF ON OFF E3X E3X-Fjj/-VGjj No light is emitted from the projection fiber head when self-diagnostic input is ON. Light projection stops Light By short-circuiting the pink and blue cords, light projection can be stopped (with a short-circuit current of 0.2 mA max.). PNP Type Brown (+V) ON Pink (externalcheck Input) Blue (0 V) Brown (+V) External-diagnostic input Short (between brown and pink) Open LED for light projection ON OFF ON OFF Light projection stops Indicator OFF Light Pink (externalcheck Input) Blue (0 V) By short-circuiting the brown and pink cords, light projection can be stopped (with a short-circuit current of 0.2 mA max.). Special Fiber Units The following special accessories are available (order separately). Contact your OMRON representative for the details. Appearance L Fiber Units with Special Length of Stainless Steel Tube Fiber with different lengths of stainless steel tubes are available. Applicable Models E32-TC200F (tube with 0.9 dia.) E32-TC200B/DC200F (tube with 1.2 dia.) E32-DC200B (tube with 2.5 dia.) The length can be ordered in increments of 10 mm between 10 mm min. and 120 mm max. Tolerance: +1.0 mm if L is 40 mm or less. and +2.0 if L is more than 40 mm. (Note that standard Fiber Units have a 90-mm or 40-mm long stainless steel tube.) 5 41 E3X Fiber Units with 90° Bend in Stainless Steel Tube Applicable Models E32-TC200B/TC200F/DC200F Appearance Stainless Steel Tube with a 90° Bend at the Tip Length R E3X Stainless Steel Tube with a 90° Bend at the Base Length 2 R Bending radius R 5.0 R 7.5 R 10.0 R 12.5 5.0 mm 7.5 mm 10.0 mm 12.5 mm 1 1 (+1) 10.0 mm 17.5 mm 20.0 mm 22.5 mm Bending radius R 5.0 R 7.5 R 10.0 R 12.5 10.0 mm 12.5 mm 15.0 mm 17.5 mm 1 (+1) 15.0 mm 17.5 mm 20.0 mm 22.5 mm The length overall is 120 mm max. Note: If larger 2 is required, use the E39-F11 Sleeve Bender. The length overall is 120 mm max. Note: If larger 1 is required, use the E39-F11 Sleeve Bender. Sensing Distance for Tubes with 90° Bends Model E32-TC200B Amplifier Standard E3X-Tjj E3X-H11 E3X-Ajj E32-TC200F E3X-Tjj E3X-H11 E3X-Ajj E32-DC200F E3X-Tjj E3X-H11 E3X-Ajj 270 mm 400 mm 180 mm 65 mm 100 mm 50 mm 20 mm 36 mm 18 mm Bending radius R5.0 170 mm 260 mm 110 mm 30 mm 55 mm 30 mm 15 mm 30 mm 10 mm R7.5 220 mm 330 mm 140 mm 65 mm 100 mm 50 mm 20 mm 36 mm 18 mm R10.0 240 mm 360 mm 160 mm 65 mm 100 mm 50 mm 20 mm 36 mm 18 mm R12.5 270 mm 400 mm 180 mm 65 mm 100 mm 50 mm 20 mm 36 mm 18 mm Fiber Unit with Longer Fiber Applicable Models E32-TC200/-DC200 E32-TC200B/-DC200B E32-TC200E/-DC200E E32-TC200F/-DC200F E32-TC200A Appearance The length can be ordered in increments of 1 m between 6 m min. and 20 m max.. (2-m and 5-m fiber length types are standard for E32-TC200, E32-DC200.) 6 42 E3X Fiber Length vs. Sensing Distance Through-beam Fiber Unit (Based on the sensing distance using a fiber length of 2 m as 100%) Sensing distance (%) Reflective Fiber Unit (Based on the sensing distance using a fiber length of 2 m as 100%) Sensing distance (%) E3X Fiber length (m) E3X-Ajj, E32-TC200 (Typical) Sensing distance (mm) Fiber length (m) E3X-Ajj, E32-DC200 (Typical) Sensing distance (mm) Fiber length (m) Fiber length (m) 43 7 E3X E3X Dimensions Fiber Units Through-beam (Sold in Pairs) E32-T11L M2.6 x 1.4 dia. 0.45 Two hexagon clamping nuts (T = 2.4) Two toothed washers (for M4) Optical fiber, 2.2 dia. Sensing head (nickelplated brass) M4x0.7 E32-T12L 1.4 dia. 2.4 dia. Sensing head (nickel-plated brass) 3 dia. Optical fiber, 2.2 dia. 3.2 7 3 11 (14) 3 2,000 11 (14) 2,000 E32-T21L Two hexagon clamping nuts Two toothed washers Sensing head M3 x 0.5 (nickel-plated brass) Optical fiber, 1 dia. Fiber attachment (E39-F9) 25 10 E32-T22L Sensing head, 2 dia. (stainless) Heat-shrinkable tubing Optical fiber, 1 dia. Fiber attachment (E39-F9) 25 10 0.9 dia. 0.9 dia. 1.8 dia. (2) 2.5 5.5 (1.7) 11 1.8 2,000 17 22 12 2,000 E32-TC200 Two hexagon clamping nuts Two toothed washers M2.6 x 0.45 Sensing head M4 x 0.7 (nickel-plated brass) E32-TC200B E32-TC200B4 1.0 dia. 1.2 dia max. Stainless tube (SUS304) Two hexagon clamping nuts Two toothed washers Sensing head M4 x 0.7 (nickel-plated brass) 1.0 dia. 3.2 7 3 14 2.4 Optical fiber, 2.2 dia. 2,000 3.2 7 2.4 11 90 (40) (see note) Optical fiber, 2.2 dia. 2,000 Note: The value in the parentheses is for the E32-TC200B4. Two hexagon clamping nuts Two toothed washers Sensing head M3 x 0.5 (nickel-plated brass) Optical fiber, 1 dia. Fiber attachment (E39-F9) 25 10 E32-T22 Heat-shrinkable tubing 0.5 dia. Sensing head SUS303 1.4 dia. Optical fiber, 1 dia. Fiber attachment (E39-F9) 25 10 E32-TC200E 0.5 dia. 2 dia. 17 22 12 2,000 2.5 5.5 1.8 11 2,000 E32-TC200F E32-TC200F4 0.5 dia. 0.9 dia. min. Stainless tube (SUS304) Two hexagon clamping nuts Two toothed washers Sensing head M3 x 0.5 (nickel-plated brass) Optical fiber, 1 dia. Fiber attachment (E39-F9) 25 10 Note: 2.5 5.5 1.8 11 90 (40) (see note) 2,000 The value in the parentheses is for the E32-TC200F4. E32-TC200A 1.0 dia. Two hexagon clamping nuts Two toothed washers 2.6 dia. Sensing head M3 x 0.5 (nickel-plated brass) E32-T11 Sensing head (nickelSixteen, plated brass) Two hexagon clamping nuts Two toothed washers 0.265 dia. M4 x 0.7 Protective tube Optical fiber, 2.2 dia. M2.6 x 0.45 3.3 15 2,000 1.8 5.5 (1.5) 7 14 3 dia. Optical fiber, 2.2 dia. 2,000 3.2 7 2.4 (14) 1 44 E3X E32-T21 Sensing head (nickel-plated brass) M3 x 0.5 Two hexagon clamping nuts Four, 0.25 dia. Two toothed washers Protective tube Fiber attachment (E39-F9) 25 10 Optical fiber, 1 dia. E3X 2.5 5.5 1.8 11 15 2,000 E32-TC200C 1.0 dia. Two hexagon clamping nuts Two toothed washers Sensing head M4x0.7 (nickelM2.6 x 0.45 plated brass) Optical fiber, 2.2 dia. 90 2,000 (when straight) 400 (75) 22 dia. 7 3 2.4 11 E32-TC200D E32-TC200D4 Two hexagon clamping nuts Stainless Two toothed washers tube Sensing head M4 x 1.0 dia. (SUS304) 0.7 (nickel-plated 1.2 brass) dia. max. 2.4 3.2 7 11 90 (40) (see note) Optical fiber, 2.2 dia. 90 (75) 22 dia. Note: 400 The value in the parentheses is for the E32-TC200D4. 2,000 (when straight) Heat-shrinking tubing E32-T14L 45° 2.8 1.5 1 1.5 Sensing head, 3 dia. (stainless) Optical fiber, 2.2 dia. 3dia 30 35 Sensing surface 12 2,000 E32-T24 Sensing head 1 dia. SUS304 2 dia. 45% 1 0.5 1.4 dia. Protective tube Optical fiber, 1 dia. 10 Fiber attachment (E39-F9) 25 1.5 15 35 15 12 2,000 E32-T14 Heat resistive ABS Lens unit (PMMA) 4.4 dia. 7 8.2 E32-T17L Sensing head (ABS) M14 x 1 10-mm dia. lens (PMMA) Two hexagon clamping nuts Optical fiber, 2.2 dia. R3.5 10.5 7 8 Optical axis Two, 3.2 dia. Optical fiber, 2.2 dia. 19 2.5 10+0.2 9.2 16 11.2 2,000 5 23 42 10,000 E32-T12F 4-mm dia. lens Sensing head, 5 dia. Fluoride resin 4 dia. Optical fiber, 2.2 dia. 20 2,000 100 2 45 E3X E32-M21 Sensing head M3 x 0.35 (SUS303) Two hexagon clamping nuts Two toothed washers Silicone tube E3X Note: Plastic fibers, four, 1 dia. One set of silicone tubes is black while the other set is gray for easy identification when they are connected to the light source and receiver. Sleeve 13 28 1.8 11 23 2,000 E32-T51 1.5 dia. Two hexagon clamping nuts Two toothed washers Sensing head M4 x 0.7 (nickel-plated brass) Note: Resistant temperature is 150°C. Resistant temperature is 130°C when used continuously. 7 2.85 dia. 1 2.4 15 17 Optical fiber, 2.2 dia. 2,000 E32-T61 Two hexagon clamping nuts Two toothed washers 1.0 dia. M2.6 x 0.45 SUS flexible tube 2.8 dia. Sensing head M4 x 0.7 (SUS303) Hexagon clamping screw 4 dia. 5 dia. Sleeve 7 3 20 2.4 4 dia. 10 A 2,000 5 28 B (See note) 13 Note: Section A resists 300°C and section B (which is inserted to the Amplifier) resists 110°C. The operating temperature of section B must also be within the withstand temperature range of the Amplifier. 3 46 E3X Reflective E32-D11L Two, 1.4 dia. 4 dia. Two hexagon clamping nuts Two toothed washers Sensing head (nickel-plated brass) M6 x 0.75 Two optical fiber, 2.2 dia. E3X 5.2 10 3 20 2.4 2,000 E32-D12 2,000 (standard length) 3 dia. 15 135 Two, 1 dia. Sensing head (stainless) Heat-shrinkable tubing Optical fibers, two, 2.2 dia. E32-D21L Two, 0.9 dia. Two hexagon clamping nuts Two toothed washers Sensing head M4 x 0.7 (nickel-plated brass) Optical fiber, two, 1 dia. Two fiber attachments (E39-F9) 25 10 3.2 7 3 15 2.4 2,000 Two fiber attachments (E39-F9) 25 10 Optical fiber, two, 1 dia. E32-D22L Two, 0.9 dia. 2.7 dia. Sensing head 3 dia. (nickel-plated brass) 3 15 2,000 E32-DC200 Two, 1.0 dia. 4 dia. Two hexagon clamping nuts Two toothed washers Sensing head M6 x 0.75 (ADC) Optical fiber, 2.2 dia. 3 4.8 10 2.4 17 2,000 E32-DC200B E32-DC200B4 Stainless Two hexagon clamping nuts Two, 1.0 dia. tube Two toothed washers (SUS304) Sensing head M6 x 0.75 (fine screw) 2.5 dia. max. Note: 5.2 10 2.4 90 (40) (see note) 17 Optical fiber, 2.2 dia. 2,000 The value in the parentheses is for the E32-DC200B4. E32-DC200E Two, 0.5 dia. Two hexagon clamping nuts Two toothed washers Sensing head M3 x 0.5 (SUS304) Optical fiber, two, 1 dia. Two fiber attachments (E39-F9) 25 10 2.5 5.5 1.8 11 2,000 4 47 E3X E32-DC200F E32-DC200F4 Stainless tube Two, 0.5 dia. (SUS304) 1.2 dia. min. Two hexagon clamping nuts Two toothed washers Sensing head M3 x 0.5 (SUS304) Optical fiber, two, 1 dia. Fiber attachment (E39-F9) 25 10 E3X 2.5 5.5 90 (40) (see note) 1.8 11 2,000 Note: The value in the parentheses is for the E32-TC200F4. E32-D11 Sensing head Two hexagon clamping nuts (SUS303) Sixteen, Two toothed washers (10 teeth) 0.265 dia. M6 X 0.75 Protective tube Optical fiber, two, 2.2 dia. 2.4 5.2 10 17 15 2,000 E32-D21 Sensing head (nickel-plated brass) Two hexagon clamping nuts M3 x 0.5 Two toothed washers Four, 0.25 dia. Protective tube Fiber attachment (E39-F9) 25 10 Optical fiber, two, 1 dia. 2.5 5.5 1.8 11 15 2,000 E32-DC200C Two, 1.0 dia. Two hexagon clamping nuts Two toothed washers Sensing head M6 x 0.75 (nickelplated brass) (150) 22 dia. 2.4 17 Optical fiber, 2.2 x 2 dia. 90 2,000 (when straight) 5.2 10 400 E32-DC200D E32-DC200D4 Stainless Two, 1.0 dia. tube 2.5 dia. (SUS304) max. Two hexagon clamping nuts Two toothed washers Sensing head M6 x 0.75 (SUS304) (150) Note: The value in the parentheses is for the E32-DC200D4. 22 dia. Optical fiber, two, 2.2 dia. 90 2.4 5.2 10 90 17 (40) (see note) 2,000 (when straight) Sleeve 400 E32-DC9G E32-DC9G4 1.2 dia. max. Stainless tube 4 8 15 Do not bent the stainless tube in this range. 10 90 (40) (see note) 17 7.5 13 6 Note: The value in the parentheses is for the E32-TC200F4. Fiber attachment (E39-F9) 25 E32-D33 Two, 0.25 dia. Sensing head (SUS303) 3 dia. 0.8 dia. Heat-shrinkable tubing Optical fiber, two, 1 dia. 10 15 35 15 12 2,000 5 48 E3X E32-CC200 Sixteen, 0.25 dia. for light reception 1.0 dia. for light emission 2.5 dia. Two hexagon clamping nuts Two toothed washers Sensing head M6 x 0.75 Optical fiber, two, 2.2 dia. (nickel-plated brass) E3X 5.2 10 3 2.4 23 2,000 Note: The fiber for the light source is identified by a white line. Two fiber attachments (E39-F9) 25 E32-D32 Light source fiber (0.5 dia.) Sensing head SUS303 Optical fibers, two, 1 dia. 2 dia. 3 dia. Heat-shrinkable tubing 10 Receive fiber (0.25 dia.) x 4 15 22 2 12 2,000 Note: The fiber for the light source is identified by a white line. E32-D32L Light source (1 dia.) 15 400 2,000 (standard length) 15 1,570 Receive (0.265 dia.) x 16 Sensing head, 3 dia. (stainless) Branching box, 6 dia. (heat-resistive ABS black resin) Optical fibers, two, 2.2 dia. Note: The fiber for the light source is identified by a yellow dotted line. Optical fiber, two, 2.2 dia. Heat-shrinkable tubing E32-D14L 5.7 6 dia. 1.5 1 2 Sensing head (stainless) 45° Light baffle 30 35 12 2,000 Sensing surface E32-D24 Sensing head (SUS304) 2 dia. 3 dia. 45% Heat-shrinkable tubing Optical fibers, two, 1 dia. Two fiber attachments (E39-F9) 25 10 1 0.5 1.5 15 35 15 12 2,000 Light baffle Sensing surface E32-D12F Sensing head, 6 dia. Fluoride resin 5 dia. Optical fiber, two, 2.2 dia. 16 2,000 100 6 49 E3X E32-D51 Two, 1.5 dia. 4.9 2.4 3 13 17 2,000 Two hexagon clamping nuts Two toothed washers Optical fiber, 2.2 dia. Sensing head,M6 x 0.75* E3X *nickel-plated brass Note: 3.1 10 Resistant temperature is 150°C. Resistant temperature is 130°C when used continuously. E32-D61 1.4 dia. M4 x 0.7 Two hexagon clamping nuts Two toothed washers SUS304 Sensing head (SUS303) SUS flexible tube Hexagon clamping screw M3 x 0.75 5 dia. 3.5 dia. Sleeve 8 15 10 32 20 2.4 3 5 2,000 A 5 16.5 6.5 B (See note) 13 6.4 Note: Section A resists 300°C and section B (which is inserted to the Amplifier) resists 110°C. The operating temperature of section B must also be within the withstand temperature range of the Amplifier. Two hexagon clamping nuts Two toothed washers M4 x 0.7 (SUS303) SUS flexible tube 4 dia. 2.8 dia. E32-D73 Sensing head 2.5 dia. 1.25 dia. 1.65 dia. SUS303 Hexagon clamping screw 5 dia. Sleeve 1.0 dia. 8 15 7 5 60 5 A 2.4 20 10 2,000 B 5 16.5 6.5 C (See note) 13 6.4 Note: Section A resists 400°C, section B resists 300°C, and section C (which is inserted to the Amplifier) resists 110°C. The operating temperature of section C must also be within the withstand temperature range of the Amplifier. Two fiber attachments (E39-F9) 25 10 E32-R21 Lens (PMMA) Two hexagon clamping nuts Two washers Sensing head Silicone tube M6 x 0.75 Optical fibers, two, 1 dia. 5 dia. 2.2 10 2.8 3 11 17.8 27.8 Nameplate 27 15 7 13 14 2,000 E32-R16 10 7.2 3.2 (6) 1.5 16 1.5 3.2 4 15.2 21.5 8 Lens (PMMA) 1 17 21 22.5 16+0.2 Optical fiber, two, 2.2 dia. Standard length: 2 m Two, M3 screws (attachment) Mounting bracket (attachment) 7 50 E3X E32-L25 20 10 6.5 20 6.5 4.8 White line Optical fiber, two, 2.2 dia. Two, 3.2 dia., 6 dia. spot facing 2,000 White line 4 20 E3X E32-L25A 5 4 20 10 4.8 6.5 5 6.5 Two, 3.2 dia., 6 dia. spot facing Sensing head (ABS) 2,000 Note: The fiber for the light source is identified by a white line. Optical fiber, two, 2.2 dia. E32-L25L 4 6 16 6.5 18 25 Two, 1 dia. optical fibers 10 Two fiber attachment (E39-F9) Sensing head (PC) Two, 3.2 dia, 6 dia. counter sinking 2,000 E32-L24L 4 3.6 3.3 3.3 1.5 Optical axis 6 Two, 1 dia. optical fibers 6.5 10 4 25 18 Side view prism (PC) Two fiber attachment (E39-F9) 20 Sensing head (PC) Two, 3.2 dia, 6 dia. counter sinking 2,000 8 51 E3X Fine Through-beam E32-T22S E32-T24S 17.6 0.4 1.8 Sensing head (nickel-plate brass) 3.5 dia. 11 3.2 Optical fiber 2.2 dia. E3X 3 3.2 10 20.5 2 dia. Mounting bracket (attachment) 2,000 2 Sensing surface E32-T84S 2,000 (standard length) (see note) 4 dia. 2.9 dia. flexible tube (stainless) 4 dia. 5 dia. Sleeve 3.5 dia. Sensing head (stainless) 3 dia. Lens (2 dia.) Note: Section A resists 200°C and section B (which is inserted to the Amplifier) resists 110°C. The operating temperature of section B must also be within the withstand temperature range of the Amplifier. Slot Fiber Units E32-G14 36.3 25.2 20 9.2 R1.6 R1.6 Two, M3 R3.5 Lens (PMMA) 4 23.5 1.6 9.4 1.6 Optical fiber, 2.2 dia. Sensing head (ABS) 2,000 Mounting Holes 24 10 Optical axis 3.2 9.0 9.4 7.4 7.0 9 52 E3X Liquid Level Fiber Units E32-D82F1/E32-D82F2 (Liquid Contact Model) 6 dia. sensing head (Teflon) 9 dia. fiber connector (nickel-plate brass) Two, 2.2 dia. optical fiber (see note 2) To Amplifier Bending-prohibited length: 150 (350) (see note 1) E3X Note: 1. The value in the parentheses is for the E32-D82F2. 2. Since the 2-m optical fiber on the Amplifier side is made of plastic, the fiber is trimmable. E32-L25T (Pipe Mounting Model) Optical axis Two, 3.2 dia. lens (PC) Two, fiber attachment Two, 1 dia. optical fiber Mounting hole Sensing head (PC) 2,000 (standard length) 10 53 E3X E32-T16 10.2 4 20 3.2 2 (R) E3X Mounting Holes 4 20 20 Sensing head (ABS) 3 8.4 1.2 2 (R) 2 (R) 4.5 Two, M3 5.5 3.2 11 2.3 0.5-mm Wide Silt Seal (Sold in Pairs) 6 0.5 4 15.5 8.85 15 23 Black 27 25 20 1-mm Wide Silt Seal (Sold in Pairs) 58 43.2 Two, 3.2 dia. 4 6 1 6 dia. Lens (2 x 10) (PMMA) 2,000 Mounting bracket E39-L4 Black Fiber 2.2 dia. 33 15 23 E32-T16P Two, 3.2 dia., 6 dia counter sinking 14.5 10.7 4 0.5-mm-wide Slit Seal (Sold in Pairs) 3.4 0.5 E32-T16P with E39-L94 Mounting 35 2 4 20 4.8 19 27 20 Sensing head (2 x 11) (PMMA) 13.4 26.4 Two, M3 4 20 4 Sensing head (heat-resistive ABS) Black 12.2 3.2 1-mm-wide Slit Seal (Sold in Pairs) 2,000 3.4 1 2.2-dia. optical fiber 13.4 52 43.2 26.4 23.2 Black 2.2-dia. fiber E39-L94 Mounting Bracket 4 Sensing head 19 11 54 E3X Amplifier E3X-T11 E3X-T21 17.8 Light reception indicator 9 Stable operation indicator 12 6.5 1.2 Tuning indicator 4 E3X 59 Two, 2.4 4.2 11 32 8 8.4 25 0.4 12.5 3.9 6 22.5 13 16 35.5 3.2 dia. Mounting bracket (removable) 6 Cord: 2-m polyvinyl chloride-covered cord (4-mm dia., 3 cores*) Weight: Approx. 100 g *The cords for the E3X-T21 model has 6 cores. 3.4 22.5 2 16 E3X-H11 E3X-Ajj E3X-Fjj E3X-VGjj 15.8 Light reception indicator 9 Stable operation indicator 59 Two, 2.4 dia. 4 8 8.4 30 25 12.5 3.9 6 Cord: 2-m polyvinyl chloride-covered cord (4-mm dia., 5 cores*) Weight: Approx. 100 g *The cords for the E3X-A11, E3X-A41, and E3X-VG11 models have 3 cores. 22.5 13 16 35.5 6 Mounting bracket (removable) 3.2 dia. 3.4 22.5 2 16 12 55 E3X Reflector Reflector (Small) E39-R3 11 Adhesive tape Two, 3.5 dia. 7 20 E3X Reflector E39-R1 40.3 34 7.5 Note: Mounting bracket is attached. 0.2 59.9 52 34.8 25.4 34 38 8 1.6 2.7 19.3 Two, M3 2.6 1.2 Attachments E39-F1 Lens Kit M2.6 x 0.45 Effective depth: 3.8 Spot facing depth: 0.9 4 dia. 8.9 4 dia. 5.7 9.2 6.4 8+0.2 6.5 20.7 18 6.4 12 E39-F2 Side-view Attachment 2.8 dia. M2.6 Effective depth: 3.2 Spot facing depth: 0.9 E39-F3 Convergent Beam Conversion Kit Two, 4 dia. M3 toothed washers Two, 3.2 +0.2 dia. 0 Two, M3 x 3 Slotted head machine screw Note: One set includes two units. 3 3.6 8.5 M3 x 6 Angle fixing screw E39-F5 Side-view Diffuse Reflective Conversion Kit (for the E32-TC200A) Sensing hole Two, 3.2 dia. 12.2 Two, M3 Fiber unit mounting Two, 3.2 dia. holes (E32-TC200A) Mounting hole 2.1 4 13 2.6 4 10.5+0.1 18 5 E39-F3A Reflective Lens Unit (for the E32-D32) 4 dia. 6 dia. Lens (3.7 dia.) 23 M2 x 2 3 13 2.1 dia. 56 13 E3X Protective Spiral Tubes E39-F32A, E39-F32A5 E39-F32B, E39-F32B5 M3 x 0.5 depth: 4 6 dia. 12 L 12 Head connector 4.6 dia. End cap 3 dia. E3X Note: 1. L is as follows: E39-F32A and E39-F32B: 1,000 E39-F32A5, E39-F32B5: 500 2. A pair of E39-F32A(5)’s is sold as E39-F32B(5). Head connector 5.6 dia. End cap 4 dia. E39-F32C, E39-F32C5 M4 x 0.7 depth: 4 7 dia. 12 L 12 Note: L is as follows: E39-F32C: 1,000 E39-F32C5: 500 Head connector 7 dia. End cap 5 dia. E39-F32D, E39-F32D5 M6 x 0.75 depth: 4 8.5 dia. 12 L 12 Note: L is as follows: E39-F32D: 1,000 E39-F32D5: 500 Accessories E39-F4 Fiber Cutter Holes for standard fiber Holes for thin fiber E39-F9 Attachment for Thin Fiber E39-F10 Fiber Connector 1.1 dia. Insertion mark (2.4 dia.) 10 11.7 25 Retention clip Splice Retention clip Fiber 3.6 dia. 3.8 dia. 26 3 dia. 12.8 2.2 dia. Note: One set includes two Units. 14 57 E3X E39-G3 Manual Sensitivity Adjustment Knob Note: Cannot be used with the E3X-Tjj. E3X 10 dia. E39-G4 Protective Cover Note: Cannot be used with the E3X-Tjj. 15 58 E3X E3X Installation Connections Connection with S3D2 Sensor Controller Blue Black Brown +12 V 7 10 IN1 NORM 4 5 1 2 8 11 9 12 IN2 INV 6 3 0V Connection with S3D8 Sensor Controller Black Blue 0 V Brown +12 V IN1 Note: A maximum of two E3X Optical Fiber Photoelectric Sensors can be connected. Output Relay AND, OR Note: A maximum of eight E3X Optical Fiber Photoelectric Sensors can be connected. NPN input S3D2-AK-US S3D2-CK-US S3D2-BK-US S3D2-CC-US PNP input S3D2-AKB-US S3D2-CKB-US --S3D2-CCB-US Power supply voltage 100 to 240 VAC Functions AND, OR, and timer Flip-flop Transistor AND, OR, and timer 16 59 E3X E3X Precautions Fiber Units Tightening Force The tightening force applied to the Fiber Unit should be as follows: Screw-mounting Model Spring mounting clip Toothed washers Fiber Connection and Disconnection The E3X Amplifier has a push lock. Connect or disconnect the fibers to or from the E3X Amplifier using the following procedures: 1. Connection Nuts (attachment) Column Model Retaining screw (M 3 max.) Clamping torque 3 kgf S cm max. Insert the fibers into the E3X Amplifier and press the push lock until the Amplifier clicks to lock the fibers. The fibers will have insertion marks when they are cut with the E39-F4 (Fiber Cutter). The portion from the tips to the insertion mark should be inserted to the E3X. 2. Disconnection Be sure to press the push lock again to unlock before pulling out the fiber, otherwise the fiber may be deteriorated. Fiber Insertion If the portion from the tip to the insertion mark of the fibers are not inserted into the Amplifier Unit, the sensing distance will be reduced. Fiber units M3/M4 screw M6 screw 2-mm dia. column 3-mm dia. column E32-D14L E32-T12F E32-D12F E32-T16 E32-R21 E32-M21 Clamping torque 8 kgf S cm max. (0.78 N S m) 10 kgf S cm max. (0.98 N S m) 3 kgf S cm max. (0.29 N S m) 3 kgf S cm max. (0.29 N S m) 10 kgf S cm max. (0.98 N S m) 8 kgf S cm max. (0.78 N S m) 8 kgf S cm max. (0.78 N S m) 5 kgf S cm max. (0.49 N S m) 6 kgf S cm max. (0.59 N S m) Up to 5 mm to the tip: 5 kgf S cm max. (0.49 N S m) Up to 5 mm from the tip: 8 kgf S cm max. (0.78 N S m) 8 kgf S cm max. (0.78 N S m) Fiber unit 12.6 mm 2.2-mm dia. Fiber Insertion mark Amplifier Thin Fiber with the E39-F4 Attachment The portion from the tips to the insertion mark should be inserted into the E3X. Amplifier Fiber unit 12.6 mm E32-L25A Use a proper-sized wrench. Fiber with Fixed Length The portion from the tips to the insertion mark should be inserted into the E3X. Amplifier 12.6 mm 17 60 E3X Cutting Fiber Insert a fiber into the Fiber Cutter and determine the length of the fiber to be cut. Press down the Fiber Cutter in a single stroke to cut the fiber. When the fiber is cut, an insertion mark is inscribed on the fiber. For a 2.2-mm dia. standard fiber only. 40 mm max. 12.6 Insertion mark E3X Connection Do not pull or press the Fiber Units. The Fiber Units have a withstand force of 1 kg or 3 kg (pay utmost attention because the fibers are thin). Do not bend the Fiber Units beyond the permissible bending radius. Do not bend the edge of the Fiber Units. Correct Amplifier 2.2-dia. Fiber unit Insert a fiber into the Fiber Cutter in the direction indicated by the arrow (refer to the following figure). 2 20 mm max. Incorrect Do not apply excess force on the Fiber Units. 1 Fiber unit Fiber unit The cutting holes cannot be used twice. If the same hole is used twice, the cutting face of the fiber will be rough and the sensing distance will be reduced. Always use an unused hole. Use either one of the two holes on the right (refer to the following figure) to cut a thin fiber as follows: 1. An attachment is temporarily fitted to a thin fiber before shipment. Nylon wireholder Correct Metal holder Incorrect The Fiber Head could be broken by excessive vibration. To prevent this, the following is effective: Temporarily fitted 2. Secure the attachment after adjusting the position of it in the direction indicated by the arrow. 3. Insert the fiber into the E39-F4 to cut. A A one-turn loop can one-turn loop can absorb vibrations. absorb vibrations Tape Cutter E39-F4 Two holes for thin fiber Three holes for standard fiber (2.2 mm dia.) Note: Insert the fiber in the direction indicated by the arrow. 18 61 E3X Bending Radius E39-F11 Sleeve Bender The bending radius of the stainless tube should be as large as possible. The smaller the bending radius becomes, the shorter the sensing distance will be. Insert the tip of the stainless sleeve to the Sleeve Bender and bend the stainless sleeve slowly along the curve of the Sleeve Bender (refer to the figure). 1.2 dia. 1.2 dia. 1.3 dia. max. max. min. R 10 R 12.5 R 7.5 Fiber tip position mark Seal R5 E3X Handling E32-D51/-T51 Heat-resisting Fiber The bending radius of the fibers should be 35 mm min. Connecting fibers via the E39-F10 Fiber Connector is not possible. The withstand temperature of the Heat-Resisting Fibers is 150°C max. In continuous operation, the ambient temperature should be 130°C max. E32-T14/-T51 If the sensor is ON because some object in front of the lenses reflects light, attach the black seals (sold together) to the lenses. E32-T14/-G14 Stainless tube E32-L25 (A) Wafer Sensor Insert the fiber with a white line into the light projection side of the Amplifier. The tightening force of the sensor head is 8 kgf S cm (0.75 N S m). Avoid places where water could be sprayed onto the E32-L25(A). E32-T16 Slit Seal (Attachment) Peel the E32-T16 Slit Seal off the ground paper and affix the Slit Seal to the sensing face of the sensor so that the corners of the Slit Seal fit in with the corners of the sensing face. To sense an object at a distance of 30 cm max., a 0.5-mm wide Slit Seal must be used. 90o max. 10 10 Do not bend here. E32-T16 Sensing Head Attachment slit Amplifier Units Mounting Mounting 1. Mount the front part on the mounting bracket (sold together) or a DIN rail. 2. Press the back part onto the mounting bracket or the DIN rail. 3 Others When power is off: The moment power is turned off, the E3X could output a pulse signal which could affect the operation of the devices connected to it. This will happen more often if power is supplied to the E3X from an external power supply, thus affecting the connected timer and counter. Use a built-in power supply as much as possible to avoid this. If power is supplied to a photoelectric sensor through a cord that is wired together with other power lines in the same duct, the cord will be influenced by the power lines and malfunctioning of the photoelectric sensor or damage could result. Wire the cord separately or use a sealed cord to supply power to the photoelectric sensor. In the case of the cord is extended, use a wire with 0.3 mm2 max.. The total length of the cord should be 100 m max. 2 1 DIN rail Power lineline Power Dismounting By pulling back the lock (yellow) on the bottom with a flat blade screwdriver, the Amplifier can be dismounted with ease. In the case of side mounting, attach the mounting bracket on the Amplifier first, and secure the Amplifier with M3 screws and washers. The diameter of the washers should be 6 mm max. Washers (6 dia. max.) Power supply: If a standard switching regulator is used as a power supply, the frame ground (FG) terminal and the ground (G) terminal must be grounded, or otherwise the E3X can malfunction, influenced by the switching noise of the power supply. The supplied voltage must be within the rated voltage range. Unregulated full- or half-wave rectifiers must not be used as power supplies. Do not use a hammer to hit the Amplifier when mounting or the Amplifier will loose watertightness. 19 62 E3X Attachment Units Applications E39-F10 Fiber Connector Use the following procedure (refer to the figure) to connect fibers via the Fiber Connector. Splice Retention Unit Retention Unit E3X E39-F3A Reflective Unit Lens When the E39-F3A is attached to the fiber, the E3X can sense the light reflected from the interior of the E39-F3A. If this happens, adjust the sensitivity of the E3X Amplifier with Sensitivity Adjustor. Place a sensing object or white paper at the sensing distance set and adjust the insertion length of the Fiber Unit to the E39-F3A so that the light spot is as small as possible. Then fix the position of the Fiber Unit with the hexagonal wrench (attachment) Tighten Loosen A Lens Each fiber should be as close as possible before they are connected. Sensing distance will be reduced by approximately 25% when fibers are connected. Only fibers with 2.2 mm dia. can be connected. Protective Spiral Tube Insert a fiber to the Protective Spiral Tube from the head connector side (screwed) of the tube. B Insertion Fiber Unit (E32-D32) A: The focus is farther than the E39-F3A. B: The focus is closer than the E39-F3A E39-G3 Sensitivity Adjustor 1. Remove the cover of the E3X. 2. Attach the E39-G3 (refer to the figure). Protective spiral tube Fiber Unit Knob Cover Push the fiber into the Protective Spiral Tube. The tube should be straight so that the fiber is not twisted when inserted. Then turn the end cap of the spiral tube. Protective spiral tube Fiber Unit Secure the Protective Spiral Tube on a suitable place with the attached nut. Mounting panel Hexagon clamping nut 3. After the cover is attached to the case, turn the knob of the E39-F3A clockwise or counterclockwise once. To confirm that the knob has been set properly, turn the knob clockwise or counterclockwise until you hear a click (8 turns max. are necessary). Note: E3X looses watertightness if E39-G3 is attached (the enclosure rating will be IP50). Fiber Unit Protective spiral tube Toothed washer Use the attached saddle to secure the end cap of the Protective Spiral Tube. To secure the Protective Spiral Tube at a position other than the end cap, apply tape to the tube so that the portion becomes thicker in diameter. Saddle Tube End cap 20 63 E3X E3X ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. E215-E1-3 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Systems Components Division H.Q. 28F Crystal Tower Bldg. 1-2-27, Shiromi, Chuo-ku, Osaka 540 Japan Phone: 06-949-6012 Fax: 06-949-6021 Printed in Japan 0196-2M (0691) a 21 64
E32-T84S 价格&库存

很抱歉,暂时无法提供与“E32-T84S”相匹配的价格&库存,您可以联系我们找货

免费人工找货