0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
G2R-1-SND

G2R-1-SND

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

  • 描述:

    G2R-1-SND - PCB Relay A Power Relay for a Variety of Purposes with Various Models - Omron Electronic...

  • 数据手册
  • 价格&库存
G2R-1-SND 数据手册
PCB Relay A Power Relay for a Variety of Purposes with Various Models I G2R I I I I I I I Conforms to VDE0435 (VDE approval: C250 insulation grade), UL508, CSA22.2, SEV, SEMKO. Meets VDE0700 requirements for household products according to VDE0110. Clearance and creepage distance: 8 mm/8 m. Models with CTI250 material available. High-sensitivity (360 mW) and high-capacity (16 A) types available. Double-winding latching type available. Plug-in with test button and quick-connect terminals available. Highly functional socket available. X RC+SE VDE Ordering Information Classification PCB terminal General-purpose Bifurcated contact High-capacity High-sensitivity Double-winding latching Plug-in terminal General-purpose LED indicator LED indicator with test button Diode LED indicator and diode LED indicator and diode with test button Plug-in terminal (Bifurcated crossbar contact) General-purpose LED indicator LED indicator and diode DC AC/DC DC Enclosure ratings Flux protection Fully sealed Flux protection Fully sealed Flux protection Flux protection Flux protection Unsealed AC/DC AC/DC DC DC Coil ratings AC/DC Contact form SPST-NO G2R-1A G2R-1A4 G2R-1AZ G2R-1AZ4 G2R-1A-E G2R-1A-H G2RK-1A ------------G2R-1A3-S G2R-1A3-SN G2R-1A3-SND SPDT G2R-1 G2R-14 G2R-1Z G2R-1Z4 G2R-1-E G2R-1-H G2RK-1 G2R-1-S G2R-1-SN G2R-1-SNI G2R-1-SD G2R-1-SND G2R-1-SNDI G2R-13-S G2R-13-SN G2R-13-SND DPST-NO G2R-2A G2R-2A4 ------G2R-2A-H G2RK-2A ------------------DPDT G2R-2 G2R-24 ------G2R-2-H G2RK-2 G2R-2-S G2R-2-SN G2R-2-SNI G2R-2-SD G2R-2-SND G2R-2-SNDI ------- Note: 1. When ordering, add the rated coil voltage to the model number. Example: G2R-1A 12 VDC Rated coil voltage 2. OMRON has also prepared the above relays with AgSnIn contacts, which are more tolerant of large inrush currents and physical movement compared with relays with standard contacts. When ordering, add "-ASI" to the model number. Example: G2R-1A-ASI 3. Standard, NO contact type relays are TV-3 class products in accordance with the TV standards of the UL/CSA. Models with AgSnIn contacts are TV-5 class products. Example: G2R-1A-ASI When ordering a TV-8 class model, insert "-TV8" into the model number as follows: Example: G2R-1A-TV8-ASI 4. Models with CTI250 material are also available. Contact your OMRON representative for more details. 141 G2R Model Number Legend G2R G2R 1 2 345 678 9 10 VDC S: Plug-in T: Quick-connect (upper bracket mounting) 7. Classification None: General-purpose E: High-capacity H: High-sensitivity N: LED indicator D: Diode ND: LED indicator and diode 8. Test button I: Test button Note: Applied for only SN and SND type 9. Contact Material None: AgCdO ASI: AgSnIn 10. Rated Coil Voltage Refer to Coil Ratings. 1. Relay Function None: Single-side stable K: Double-winding latching. 2. Number of Poles 1: 1 pole 2: 2 poles 3. Contact Form None: PST-NO A: 4. Contact Type None: Single Z: Bifurcated 3: Bifurcated crossbar 5. Enclosure Ratings None: Flux protection 4: Fully sealed 6. Terminals None: Straight PCB I #PDT # Accessories (Order Separately) Applicable Relay model Track/surface-mounting Socket Back-mounting Socket Terminals PCB terminals Solder terminals PCB terminals Solder terminals Model P2R-05P, P2R-057P P2R-05A P2R-08P, P2R-087P P2R-08A Connecting Sockets Number of poles 1 pole G2R-1P2RF-05-E S(N)(D)(ND)(NI)(NDI)G2R-13- P2RF-05 S (G2R-1A3-S) G2R-2-S(N)(D)(ND)(NI)(NDI) See Dimensions for details on socket size. P2RF-08-E P2RF-08 2 poles Note: Mounting Track Applicable socket Track connecting socket Description Mounting track 50 cm ( ) x 7.3 mm (t): PFP-50N 1 m ( ) x 7.3 mm (t): PFP-100N 1 m ( ) x 16 mm (t): PFP-100N2 8 8 8 Model End plate Spacer Back connecting socket Mounting plate PFP-M PFP-S P2R-P* *Used to mount several P2R-05A and P2R-08A connecting sockets side by side. 142 G2R G2R Specifications I Coil Ratings 12 VAC 50 Hz 60 Hz 93 mA 75 mA 65 W Armature OFF Armature ON 0.19 0.39 24 VAC 46.5 mA 37.5 mA 260 W 0.81 1.55 100/ (110) VAC 11 mA 9/ (10.6) mA 4,600 W 13.34 26.84 120 VAC 9.3 mA 7.5 mA 6,500 W 21 42 200/ (220) VAC 5.5 (4.0) mA 4.5 (5.3) mA 20,200 (25,000) W 51.3 102 220 VAC 5.1 mA 4.1 mA 25,000 W 57.5 117 230 VAC 240 VAC Rated voltage Rated current 4.7 (3.7) mA 4.7 mA 3.8 (3.1) mA 3.8 mA 26,850 (30,000) W 62 124 30,000 W 65.5 131 Coil resistance Coil inductance (H) (ref. value) Must operate voltage Must release voltage Max. voltage Power consumption Note: 80% max. of rated voltage 30% min. of rated voltage 140% of rated voltage (at 23•C) Approx. 0.9 VA at 60 Hz (approx. 0.7 VA at 60 Hz) 1. Rated voltage of bifurcated crossbar contact type: 100/(110) VAC, 200/(220) VAC, 230 VAC (Approx. 0.7 VA at 60 Hz) 2. Depending on the type of Relay, some Relays do not have coil specifications. Contact your OMRON representative for more details. Rated voltage Rated current (50/60 Hz) Coil resistance Coil inductance (H) (ref. value) Armature OFF Armature ON 5 VDC 106 mA 47 W 0.20 0.39 6 VDC 88.2 mA 68 W 0.28 0.55 12 VDC 43.6 mA 275 W 1.15 2.29 24 VDC 21.8 mA 1,100 W 4.27 8.55 48 VDC 11.5 mA 4,170 W 13.86 27.71 100 VDC 5.3 mA 18,860 W 67.2 93.2 Must operate voltage Must release voltage Max. voltage Power consumption Note: 70% max. of rated voltage 15% min. of rated voltage 170% of rated voltage (at 23•C) Approx. 0.53 W Rated voltage of bifurcated crossbar contact type: 12 VDC, 24 VDC High-sensitivity Relays Rated voltage Rated current (50/60 Hz) (see note 1.) Coil resistance (see note 1.) Coil inductance (H) (ref. value) Armature OFF Armature ON 5 VDC 71.4 mA 70 W 0.37 0.75 6 VDC 60 mA 100 W 0.53 1.07 12 VDC 30 mA 400 W 2.14 4.27 24 VDC 15 mA 1,600 W 7.80 15.60 48 VDC 7.5 mA 6,400 W 31.20 62.40 Must operate voltage Must release voltage Max. voltage Power consumption Note: 70% max. of rated voltage 15% min. of rated voltage 170% of rated voltage (at 23•C) Approx. 0.36 W 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of +15%/–20% (AC rated current) or ±10% (DC coil resistance). 2. LEDs are used for the built-in operation indicator. For models equipped with these indications, the VAC rated current must be increased by approximately 1 mA; the VDC rated current, by approximately 4 mA. 3. Operating characteristics are measured at a coil temperature of 23°C. 143 G2R Double-winding Latching Relays Rated voltage Set coil Rated current (see note 1.) Coil resistance (see note 1.) Coil inductance (H) (ref. value) Reset coil Rated current Coil resistance Coil inductance (H) (ref. value) Must set voltage Must reset voltage Max. voltage Power consumption Note: I Armature OFF Armature ON Armature OFF Armature ON 5 VDC 167 mA 30 W 0.073 0.146 119 mA 42 W 0.003 0.006 6 VDC 138 mA 43.5 W 0.104 0.208 100 mA 60 W 0.005 0.009 12 VDC 70.6 mA 170 W 0.42 0.83 50 mA 240 W 0.018 0.036 24 VDC 34.6 mA 694 W 1.74 3.43 25 mA 960 W 0.079 0.148 G2R 70% max. of rated voltage 70% max. of rated voltage 140% of rated voltage (at 23•C) Set coil: Approx. 850 mW; Reset coil: Approx. 600 mW 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2. Operating characteristics are measured at a coil temperature of 23°C. Contact Ratings Item General-purpose, quick-connect terminal 1 pole Resistive load (cosf = 1) Inductive load (cosf = 0.4; L/R = 7 ms) 2 poles Resistive load (cosf = 1) 5 A at 250 VAC; 5 A at 30 VDC 5A 380 VAC, 125 VDC 5A 1,875 VA, 150 W 1,250 VA, 150 W 10 mA at 5 VDC 500 VA, 90 W Inductive load (cosf = 0.4; L/R = 7 ms) 2 A at 250 VAC; 3 A at 30 VDC 1 pole Resistive load (cosf = 1) Inductive load (cosf = 0.4; L/R = 7 ms) High-capacity PCB/Flux Protection, Plug-in, Quick-connect Terminal Relays Number of poles Load Rated load 10 (1) A at 250 VAC; 7.5 A at 250 10 (1) A at 30 VDC VAC; 5 A at 30 VDC 10 (1) A 16 A at 250 8 A at 250 VAC; VAC; 8 A at 30 VDC 16 A at 30 VDC 16 A 380 VAC, 125 VDC 16 A 4,000 VA, 480 W 2,000 VA, 240 W Rated carry current Max. switching voltage 380 VAC, 125 VDC Max. switching current 10 (1) A Max. switching power Failure rate (reference value) Note: 2,500 (250) VA, 300 (30) W 100 mA at 5 VDC (1 mA at 5 VDC) 100 mA at 5 VDC 1. P level: l60 = 0.1 x 10–6/operation 2. ( ): Bifurcated crossbar contact type. PCB/Flux Protection Relays Item Number of poles Load 1 pole Resistive load (cosf = 1) Inductive load (cosf = 0.4; L/R = 7 ms) Bifurcated contacts 1 pole Resistive load (cosf = 1) Inductive load (cosf = 0.4; L/R = 7 ms) High-sensitivity 2 poles Resistive load (cosf = 1) Inductive load (cosf = 0.4; L/R = 7 ms) Rated load Rated carry current 5 A at 250 VAC; 2 A at 250 VAC; 5 A at 30 VDC 3 A at 30 VDC 5A 5 A at 250 VAC; 2 A at 250 VAC; 5 A at 30 VDC 3 A at 30 VDC 5A 380 VAC, 125 VDC 5A 1,250 VA, 150 W 100 mA at 5 VDC 500 VA, 90 W 3 A at 250 VAC; 1 A at 250 VAC; 3 A at 30 VDC 1.5 A at 30 VDC 3A 380 VAC, 125 VDC 3A 750 VA, 90 W 10 mA at 5 VDC 250 VA, 45 W Max. switching voltage 380 VAC, 125 VDC Max. switching current 5 A Max. switching power Failure rate (reference value) Note: 1,250 VA, 150 W 1 mA at 5 VDC 500 VA, 90 W P level: l60 = 0.1 x 10–6/operation 144 G2R PCB/Fully sealed Relays Item Number of poles Load 1 pole Resistive load (cosf = 1) Inductive load (cosf = 0.4; L/R = 7 ms) General-purpose (single contact) 2 poles Resistive load (cosf = 1) Inductive load (cosf = 0.4; L/R = 7 ms) 1 pole Resistive load (cosf = 1) Bifurcated contact G2R Inductive load (cosf = 0.4; L/R = 7 ms) Rated load Rated carry current 8 A at 250 VAC; 6 A at 250 VAC; 8 A at 30 VDC 4 A at 30 VDC 8A 4 A at 250 VAC; 1.5 A at 250 VAC; 5 A at 250 VAC; 2 A at 250 VAC; 4 A at 30 VDC 2.5 A at 30 VDC 5 A at 30 VDC 3 A at 30 VDC 4A 380 VAC, 125 VDC 4A 1,000 VA, 120 W 10 mA at 5 VDC 375 VA, 75 W 5A 380 VAC, 125 VDC 5A 1,250 VA, 150 W 1 mA at 5 VDC 500 VA, 90 W Max. switching voltage 380 VAC, 125 VDC Max. switching current 8 A Max. switching power Failure rate (reference value) Note: 2,000 VA, 240 W 100 mA at 5 VDC 1,500 VA, 120 W P level: l60 = 0.1 x 10–6/operation Latching Relays Number of poles Load 1 pole Resistive load (cosf = 1) 5 A at 250 VAC; 5 A at 30 VDC 5A Inductive load (cosf = 0.4; L/R = 7 ms) 3.5 A at 250 VAC; 2.5 A at 30 VDC 2 poles Resistive load (cosf = 1) 3 A at 250 VAC; 3 A at 30 VDC 3A 380 VAC, 125 VDC 3A 875 VA, 75 W 750 VA, 90 W 10 mA at 5 VDC 375 VA, 60 W Inductive load (cosf = 0.4; L/R = 7 ms) 1.5 A at 250 VAC; 2 A at 30 VDC Rated load Rated carry current Max. switching voltage 380 VAC, 125 VDC Max. switching current 5 A Max. switching power Failure rate (reference value) Note: I 1,250 VA, 150 W 100 mA at 5 VDC P level: l60 = 0.1 x 10-6/operation Characteristics Item 1 pole 30 mW max. (high-capacity type: 100 mW max.) 15 ms max. AC: 10 ms max.; DC: 5 ms max. (w/built-in diode: 20 ms max.) Mechanical: 18,000 operations/hr Electrical: 1,800 operations/hr (under rated load) 1,000 MW min. (at 500 VDC) 5,000 VAC, 50/60 Hz for 1 min between coil and contacts*; 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity 5,000 VAC, 50/60 Hz for 1 min between coil and contacts*; 3,000 VAC, 50/60 Hz for 1 min between contacts of different polarity 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity 50 mW max. 2 poles Standard Relays Contact resistance Operate (set) time Release (reset) time Max. operating frequency Insulation resistance Dielectric strength Vibration resistance Shock resistance Endurance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Destruction: 1,000 m/s2 Malfunction: 200 m/s2 when energized; 100m/s2 when no energized Mechanical: AC coil: 10,000,000 operations min.; DC coil: 20,000,000 operations min. (at 18,000 operations/hr) Electrical: 100,000 operations min. (at 1,800 operations/hr under rated load) Operating: -40°C to 70°C (with no icing) Operating: 5% to 85% Approx. 17 g (plug-in terminal: approx. 20 g) Ambient temperature Ambient humidity Weight Note: Values in the above table are the initial values. *2,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A socket is mounted. 145 G2R Double-winding Latching Relays Item Contact resistance Set time Reset time Min. set/reset signal width Max. operating frequency Insulation resistance Dielectric strength 30 mW max. 20 ms max. 20 ms max. 30 ms max. Mechanical:18,000 operations/hr Electrical: 1,800 operations/hr (under rated load) 1,000 MW min. (at 500 VDC) 5,000 VAC, 50/60 Hz for 1 min between coil and contacts*; 1,000 VAC, 50/60 Hz for 1 min between contacts of same pole; 1,000 VAC, 50/60 Hz for 1 min between set and reset coil 1 pole 50 mW max. 2 poles G2R 5,000 VAC, 50/60 Hz for 1 min between coil and contacts*; 3,000 VAC, 50/60 Hz for 1 min between contacts of different poles 1,000 VAC, 50/60 Hz for 1 min between contacts of same pole 1,000 VAC, 50/60 Hz for 1 min between set and reset coil Vibration resistance Shock resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Destruction: 1,000 m/s2 (approx. 100G) Malfunction: Set: 500 m/s2 (approx. 50G); 200m/s2 (approx. 20G) Reset: 100 m/s2 (approx. 10G) Mechanical: 10,000,000 operations min (at 18,000 operations/hr) Electrical: 100,000 operations min. (at 1,800 operations/hr under rated load) Operating: -40°C to 70°C (with no icing) Operating: 5% to 85% Approx. 17 g Endurance Ambient temperature Ambient humidity Weight Note: I Values in the above table are the initial values. *2,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A socket is mounted. Approved Standards Model Contact form SPDT Coil ratings 3 to 110 VDC 3 to 240 VAC Contact ratings 10 A, 30 VDC (resistive) 10 A, 250 VAC (general use) TV-3 (NO contact only) UL 508 (File No. E41643) G2R-1 G2R-14 G2R-1-H G2R-1-S G2R-1-T G2R-1A G2R-1A4 G2R-1A-H G2R-1A-S G2R-1A-T G2R-1-E G2R-1A-E G2R-2 G2R-24 G2R-2-H G2R-2-S G2R-2A G2R-2A4 G2R-2A-H G2R-2A-S G2R-1A-ASI SPST-NO SPDT SPST-NO DPDT 16 A, 30 VDC (resistive, NO contact only) 16 A, 250 VAC (general use, NO contact only) TV-3 (NO contact only); 1/3 hp, 120 VAC 5 A, 30 VDC (resistive) 5 A, 250 VAC (general use) TV-3 (NO contact only) DPST-NO SPST-NO 10 A, 30 VDC (resistive) 10 A, 250 VAC (general use) TV-5/TV-8 (NO contact only) 146 G2R CSA 22.2 No.0, No.14 (File No. LR31928) Model G2R-1 G2R-14 G2R-1-H G2R-1-S G2R-1-T G2R-1A G2R-1A4 G2R-1A-H G2R-1A-S G2R-1A-T G2R-1-E G2R-1A-E G2R-2 G2R-24 G2R-2-H G2R-2-S G2R-2A G2R-2A4 G2R-2A-H G2R-2A-S G2R-1A-ASI Contact form SPDT Coil ratings 3 to 110 VDC 3 to 240 VAC Contact ratings 10 A, 30 VDC (resistive) 10 A, 250 VAC (general use) T-3 (NO contact only) G2R SPST-NO SPDT SPST-NO DPDT 16 A, 30 VDC (resistive, N.O only) 16 A, 250 VAC (general use, NO contact only) TV-3 (NO contact only) 5 A, 30 VDC (resistive) 5 A, 250 VAC (general use) TV-3 (NO contact only) DPST-NO SPST-NO 10 A, 30 VDC (resistive) 10 A, 250 VAC (general use) TV-8 (NO contact only); 1/4 hp, 125 VAC SEV Contact form 1 pole Coil ratings 3 to 110 VDC 3 to 240 VAC Contact ratings 16 A, 250 VAC1 (AgSnIn contact) 16 A, 30 VDC1 (AgSnIn contact) 10 A, 250 VAC1 5 A, 250 VAC3 10 A, 30 VDC1 5 A, 250 VAC1 2 A, 380 VAC1 5 A, 30 VDC1 2 poles 3 to 110 VDC 3 to 240 VAC SEMKO Contact form 1 pole Coil ratings 3 to 110 VDC 6 to 240 VAC Contact ratings 10/80 A, 250 VAC 3/100 A, 250 VAC 16/128 A, 250 VAC (AgSnIn contact) 5/40 A, 250 VAC 2 poles TÜV (IEC 255) Contact form 1 pole Coil ratings 3 to 110 VDC, 6 VAC to 240 VAC (for Standard coil) 3 to 48 VDC (for K, U coil) 3 to 70 VDC (for H coil) Contact ratings 10 A, 250 VAC (cosf = 1.0) 10 A, 30 VDC (0 ms) 16 A, 250 VAC (cosf = 1.0) (AgSnIn contact) 8 A, 250 VAC (cosf = 0.4) 5 A, 250 VAC (cosf =1.0) 5 A, 30 VDC (0 ms) 2.5 A, 250 VAC (cosf = 0.4) 2 poles VDE (IEC 255, VDE 0435), IMQ Contact form 1 pole Coil ratings Contact ratings 5, 6, 9, 12, 18, 24, 48, 60, 100, 110 VDC 10 A, 250 VAC (cosf = 1.0) 12, 18, 24, 48, 50, 100/(110), 110, 120, 200/(220), 220, 230, 10 A, 30 VDC (0 ms) 240 VAC 16 A, 250 VAC (cosf = 1.0) 5, 6, 9, 12, 18, 24, 48, 60, 100, 110 VDC 5 A, 250 VAC (cosf =1.0) 12, 18, 24, 48, 50, 100/(110), 110, 120, 200/(220), 220, 230, 5 A, 30 VDC (0 ms) 240 VAC 2 poles 147 G2R G2R Engineering Data Maximum Switching Power Flux Protection/Plug-in Relays G2R-1, G2R-1A, G2R-1-S, G2R-1-T, G2R-1A-T G2R-1-E, G2R-1A-E G2R-1Z, G2R-1AZ Switching current (A) Switching current (A) Switching current (A) AC inductive load (cosφ = 0.4) AC resistive load AC inductive load (cosφ = 0.4) AC resistive load AC inductive load (cosφ = 0.4) AC resistive load DC resistive load DC inductive load (L/R = 7 ms) DC inductive load (L/R = 7 ms) DC resistive load DC resistive load DC inductive load (L/R = 7 ms) Switching voltage (V) G2R-1-H, G2R-1A-H, G2R-2 G2R-2A, G2R-2-S Switching voltage (V) G2R-2-H, G2R-2A-H Switching voltage (V) G2R-13-S, G2R-1A3-S Switching current (A) Switching current (A) Switching current (A) AC inductive load (cosφ = 0.4) AC resistive load AC inductive load (cosφ = 0.4) AC resistive load AC inductive load (cosφ = 0.4) AC resistive load DC resistive load DC inductive load (L/R = 7 ms) DC resistive load DC inductive load (L/R = 7 ms) DC resistive load DC inductive load (L/R = 7 ms) Switching voltage (V) G2RK-1A, G2RK-1 Switching voltage (V) G2RK-2A, G2RK-2 Switching voltage (V) Switching current (A) Switching current (A) AC inductive load (cosφ = 0.4) AC resistive load AC inductive load (cosφ = 0.4) AC resistive load DC resistive load DC inductive load (L/R = 7 ms) DC inductive load (L/R = 7 ms) DC resistive load Switching voltage (V) Switching voltage (V) 148 G2R Fully Sealed Relays G2R-14, G2R-1A4 G2R-24, G2R-2A4 Switching current (A) G2R-1Z4, G2R-1AZ4 Switching current (A) G2R Switching current (A) AC inductive load (cosφ = 0.4) AC resistive load AC inductive load (cosφ = 0.4) DC resistive load DC inductive load (L/R = 7 ms) AC resistive load AC inductive load (cosφ = 0.4) AC resistive load DC inductive load (L/R = 7 ms) DC resistive load DC resistive load DC inductive load (L/R = 7 ms) Switching voltage (V) Switching voltage (V) Switching voltage (V) Endurance Flux Protection/Plug-in Relays G2R-1, G2R-1A, G2R-1-S, G2R-1-T, G2R-1A-T Endurance (x10 3 operations) 5,000 G2R-1-E, G2R-1A-E Endurance (x10 3 operations) G2R-1Z, G2R-1AZ Endurance (x10 3 operations) 5,000 1,000 500 250-VAC/30-VDC resistive load 250-VAC inductive load (cosφ = 0.4) 10,000 5,000 3,000 1,000 500 300 100 250-VAC (cosφ = 0.4) /30-VDC (L/R = 7 ms) inductive load 250-VAC/30-VDC resistive load 1,000 30-VDC inductive load (L/R = 7 ms) 500 250-VAC/30-VDC resistive load 100 50 30-VDC inductive load (L/R = 7ms) 100 50 250-VAC inductive load (cosφ = 0.4) Switching current (A) G2R-1-H, G2R-1A-H, G2R-2 G2R-2A, G2R-2-S Endurance (x103 operations) Switching current (A) G2R-2-H, G2R-2A-H Endurance (x10 3 operations) Switching current (A) G2R-13-S, G2R-1A3-S Endurance (x10 3 operations) 5,000 10,000 5,000 3,000 1,000 500 300 100 50 30 250-VAC/30-VDC resistive load 30-VDC inductive load (L/R = 7 ms) 10,000 7,000 5,000 3,000 1,000 700 500 300 100 70 50 30 250-VAC/30-VDC resistive load 1,000 500 30-VDC inductive load (L/R = 7 ms) 250-VAC/30-VDC resistive load 100 50 250-VAC inductive load (cosφ = 0.4) 250-VAC inductive load (cosφ = 0.4) 250-VAC (cosφ = 0.4)/30-VDC (L/R = 7 ms) inductive load Switching current (A) Switching current (A) Switching current (A) 149 G2R G2RK-1A, G2RK-1 Endurance (x10 3 operations) G2RK-2A, G2RK-2 Endurance (x103 operations) G2R 5,000 10,000 5,000 1,000 500 250-VAC/30-VDC resistive load 250-VAC inductive load (cosφ = 0.4) 250-VAC/30-VDC resistive load 30-VDC inductive load (L/R = 7 ms) 250-VAC inductive load (cosφ = 0.4) 1,000 500 100 50 100 50 30-VDC inductive load (L/R = 7ms) Switching current (A) Switching current (A) Fully sealed Relays G2R-14, G2R-1A4 Endurance (x103 operations) G2R-24, G2R-2A4 Endurance (x10 3 operations) G2R-1Z4, G2R-1AZ4 Endurance (x10 3 operations) 5,000 5,000 5,000 1,000 500 30-VDC inductive load (L/R = 7 ms) 250-VAC/30-VDC resistive load 1,000 500 250-VAC/30-VDC resistive load 250-VAC inductive load (cosφ = 0.4) 100 50 30-VDC inductive load (L/R = 7ms) 1,000 500 250-VAC/30-VDC resistive load 30-VDC inductive load (L/R = 7 ms) 100 50 250-VAC inductive load (cosφ = 0.4) 100 50 250-VAC inductive load (cosφ = 0.4) Switching current (A) Switching current (A) Switching current (A) Ambient Temperature vs Maximum Coil Voltage Maximum coil voltage (%) DC coil AC coil Note: The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. Ambient temperature (°C) 150 G2R G2R Dimensions Note: 1. All units are in millimeters unless otherwise indicated. 2. Orientation marks are indicated as follows: Relays with PCB Terminals SPDT Relays G2R-1, G2R-1Z, G2R-1-H 29 max. (28.8)* 13 max. (12.7)* Terminal Arrangement/ Internal Connections (Bottom View) Mounting Holes (Bottom View) Tolerance: ±0.1 3.5 3.5 25.5 max. (25.3)* (0.3) (2.7) 1 5 0.5 0.3 0.16 *Average value **0.3 (-H Type) 0.5** 1 2 4 (2.1) 20 3 7.5 Five, 1.3-dia. holes The illustration shows the G2R-1. 4 (No coil polarity) SPST-NO Relays G2R-1A, G2R-1AZ, G2R-1A-H 29 max. (28.8)* 13 max. (12.7)* 1 5 4 (2.1) 20 3 7.5 3.5 (2.7) 25.5 max. (25.3)* (0.3) Four, 1.3-dia. holes The illustration shows the G2R-1A. 4 0.3 0.16 0.5** 1 (No coil polarity) SPDT/High-capacity Relays G2R-1-E 29 max. (28.8)* *Average value **0.3 (-H Type) 13 max. (12.7)* 1 2 7 3 6 4 7.5 8 5 (2.1) 15 (2.1) 5 5 Eight, 1.3-dia. holes (2.7) 25.5 max. (25.3)* (0.3) 4 0.5 0.3 0.16 0.3 1 (No coil polarity) *Average value SPST-NO/High-capacity Relays G2R-1A-E 29 max. (28.8)* 13 max. (12.7)* 5 25.5 max. (25.3)* (0.3) 1 8 3 6 4 7.5 5 (2.1) 4 0.3 0.16 *Average value 0.3 1 20 (2.1) Six, 1.3-dia. holes (2.7) (No coil polarity) 151 G2R Relays with PCB Terminals SPDT Relays G2R-14, G2R-1Z4 29 max. (28.6)* 13.5 max. (12.9)* 3.5 3.5 25.5 max. (24.8)* 1 5 1 2 4 (2.1) 20 3 7.5 G2R Terminal Arrangement/ Internal Connections (Bottom View) Mounting Holes (Bottom View) Tolerance: ±0.1 (2.7) Five, 1.3-dia. holes 4 0.3 0.5 0.16 0.5 (No coil polarity) *Average value SPST-NO Relays G2R-1A4, G2R-1AZ4 29 max. (28.6)* 13.5 max. (12.9)* 1 25.5 max. (24.8)* 5 4 (2.1) 4 0.5 0.3 0.16 *Average value 1 20 3 7.5 3.5 (2.7) Four, 1.3-dia. holes (No coil polarity) Relays with Plug-in Terminals SPDT Relays G2R-1-S, G2R-1-SD, G2R-1-SN, G2R-1-SND, G2R-1-SNI, G2R-1-SNDI G2R-13-S, G2R-13-SD, G2R-13-SN, G2R-13-SND 13 max. 29 max. (28.6)* 2.5 2 29 max. (28.2)* 5 * 0.5 4.75 7.5 5.2 5.2 17.5 4 Three 0.9 x 3 elliptic holes 20 (12.7)* Terminal Arrangement/Internal Connections (Bottom View) G2R-1-S, G2R-13-S G2R-1-SN, G2R-1-SNI, G2R-13-SN (AC) 1 2 5 4 3 5 1 2 4 3 10 G2R-1-SN, G2R-1-SNI, G2R-13-SN (DC) 1 + 2 5 4 3 G2R-1-SD, G2R-13-SD (DC) 1 + 2 5 4 3 *This terminal is SPDT only. G2R-1-SND, G2R-1-SNDI, G2R-13-SND (DC) 1 + 2 5 4 3 (After confirming coil polarity, wire correctly.) (Except G2R-1-S, G2R-13-S) *Average value 13 max. (0.511)* 7.3 max. (0.287)* 4.1 max. (0.161)* 29 max. 2.5 20(1.141)* 5 29 max. (1.141)* 0.5 4.75 7.5 5.2 5.2 17.5 *Average value 152 G2R DPDT Relays G2R-2-S, G2R-2-SD, G2R-2-SN, G2R-2-SNI, G2R-2-SNDI G2R-2-SND 29 max. (28.5)* 2.5 2 28 max. (27.0)* 8 20 7 65 8 7 13 max. (12.5)* 10 G2R Terminal Arrangement/Internal Connections (Bottom View) G2R-2-S G2R-2-SN G2R-2-SNI (AC) 1 2 34 1 2 34 65 6 0.5 7.5 55 19.4 2.6 8.9 *Average value 13 max. (0.511)* 7.3 max. (0.287)* 4.1 max. (0.161)* 4 + G2R-2-SN G2R-2-SNI (DC) 1 2 34 + G2R-2-SD (DC) 1 2 34 8 7 65 8 7 65 G2R-2-SND G2R-2-SNDI (DC) 1 + 8 7 65 2 34 (After confirming coil polarity, wire correctly.) 29 max. (1.141)* 29 max. 20 (1.141)* 6 0.5 2.6 2.4 7.5 5 5 19.4 8.9 *Average value 153 G2R Relays with PCB Terminals DPDT Relays G2R-2, G2R-2-H 29 max. (28.8)* 13 max. (12.7)* G2R Terminal Arrangement/ Internal Connections (Bottom View) Mounting Holes (Bottom View) Tolerance: ±0.1 5 5 Eight, 1.3-dia. holes (2.7) 7.5 25.5 max. (25.2)* (0.3) 1 8 0.5 0.3 0.15 *Average value 0.5 1 2 7 3 6 4 5 (2.1) 15 (2.1) 4 (No coil polarity) DPST-NO Relays G2R-2A, G2R-2A-H 29 max. (28.8)* 13 max. (12.7)* 5 Six, 1.3-dia. holes (2.7) 7.5 8 0.5 1 6 5 (2.1) 20 (2.1) 25.5 max. (25.2)* (0.3) 1 3 4 4 0.3 0.15 *Average value (No coil polarity) DPDT Relays G2R-24 29 max. (28.6)* 13.5 max. (12.8)* 5 5 Eight, 1.3-dia. holes (2.7) 7.5 8 7 6 5 (2.1) 15 (2.1) 25.5 max. (24.7)* 1 2 3 4 4 0.3 0.5 0.15 0.5 1 (No coil polarity) 13.5 max. (12.8)* 5 Six, 1.3-dia. holes (2.7) 7.5 8 6 5 (2.1) 20 (2.1) *Average value DPST-NO Relays G2R-2A4 29 max. (28.6)* 25.5 max. (24.7)* 1 3 4 4 0.5 0.3 0.15 *Average value 1 (No coil polarity) Double-winding Latching Relays with PCB Terminals SPDT Relays G2RK-1 29 max. (28.8)* 13 max. (12.8)* 5 1 S 7 + 2 R 6 5 (2.1) 4 0.3 1 0.5 *Average value 1 20 3 4 7.5 3.5 3.5 (2.7) Seven, 1.3-dia. holes 25.5 max. (25.2)* (0.3) + (After confirming coil polarity, wire correctly.) 154 G2R Double-winding Latching Relays with PCB Terminals SPST-NO Relays G2RK-1A 25.5 max. (25.2)* (0.3) + 4 *Average value 0.3 1 29 max. (28.8)* 0.5 0.16 13 max. (12.8)* 1 1 S 7 + 2 R 6 5 (2.1) 20 4 7.5 29 max. (28.8)* 13 max. (12.8)* G2R Terminal Arrangement/ Internal Connections (Bottom View) Mounting Holes (Bottom View) Tolerance: ±0.1 5 3.5 (2.7) Six, 1.3-dia. holes DPDT Relays G2RK-2 25.5 max. (25.2)* (0.3) (After confirming coil polarity, wire correctly.) 5 12 + S+ R 10 9 3 8 4 7 5 7.5 6 (2.7) (2.1) 10 (2.1) 5 5 Eight, 1.3-dia. holes (2.7) 4 0.3 *Average value 0.18 1 0.18 0.15 1 DPST-NO Relays G2RK-2A 29 max. 13 max. (After confirming coil polarity, wire correctly.) 5 12 + S+ R 10 9 4 7 5 6 7.5 (2.7) (2.1) 15 (2.1) 5 Six, 1.3-dia. holes (2.7) 25.5 max. (0.3) 4 0.3 1 0.18 0.15 1 (After confirming coil polarity, wire correctly.) Terminal Arrangement/Internal Connections (Bottom View) 1 2 4 3 Relays with Quick-connect Terminals SPDT Relays G2R-1-T 7.5 30.5 max. (29.7)* 5.2 17.4 Five, 1.3-dia. holes 4.75 5.2 5 0.5 8.5 (No coil polarity) Mounting Holes (Bottom View) Tolerance: ±0.1 38 Two M3 or two 3.5 dia. 29.5 max. 2.5 *Average value 45 max. (43.9)* 30.5 max. (29.7)* 14 max. (13.1)* SPST-NO Relays G2R-1A-T 7.5 Terminal Arrangement/Internal Connections (Bottom View) 1 5.2 4 5 3 17.4 Five, 1.3-dia. holes 4.75 0.5 (No coil polarity) Mounting Holes (Bottom View) 8.5 38 Two M3 or two 3.5 dia. 29.5 max. 2.5 *Average value 45 max. (43.9)* 14 max. (13.1)* Note: Model number of quick-connect terminal is 187. 155 G2R Track/Surface Mounting Sockets P2RF-05-E M3.5 screw 59 max. 48 max. 4 G2R Terminal Arrangement (Top View) Mounting Holes (for Surface Mounting) 3.2-dia. hole (11) 2 39.5 85.5 max. 3.5-dia. hole 35.5 (14) 3 (12) 39.5+0.1 5 5 16.0 max. 11.5 61 max. (A1) (A2) 1 M3 or 3.5-dia. hole Note: Pin numbers in parentheses apply to DIN standard. P2RF-08-E 2 1.5 M3 screw 63.0 max. 48.0 max. 2 3 Terminal Arrangement (Top View) Mounting Holes (for Surface Mounting) 39.5 85.5 max. 3.5 dia. hole 11.5 35.5 (21) (22) (24) 6 7 5 3 2 4 (11) (12) (14) 3.2-dia. hole 39.5+0.1 8 (A1) 1 (A2) 5 16.0 max. 61.0 max. M3 or 3.5-dia. hole P2RF-05 7 2 Five M3.5 x 8 Terminal Arrangement 4 dia. holes Mounting Holes (for Surface Mounting) 4.2 dia. hole 71.5 max. 35.5 30+0.05 4 19.5 max. 19.5 30 max. 54 max. M3 or 3.2 dia. hole P2RF-08 7 2 Eight M3.5 x 8 4 dia. holes 4.2 dia. hole 71.5 max. 35.5 30+0.05 Terminal Arrangement Mounting Holes (for Surface Mounting) 4 19.5 max. 19.5 30 max. 54 max. M3 or 3.2 dia. hole 156 G2R Back Connecting Sockets P2R-05P (1-pole) 1 6 4.5 15 1.2 4 3.5 1.5 7 4 7 36 max. 4 (5) 15 35.5 max. 6 4.5 4 7 14.5 max. G2R Terminal Arrangement Mounting Holes Tolerance: ±0.1 4 Five 1.6 dia. holes P2R-08P (2-pole) Terminal Arrangement 4 0.3 5 5 20 1 2.8 1.5 7.5 Terminal plate thickness: 0.3 36 max. (4.3) 35.5 max. 5 5 20 7 14.5 max. 7.5 Eight 1.3 dia. holes Mounting Holes P2R-05A (1-pole) 0.3 6.7 3.8 16.7 5 5 7 1.2 14.5 max. Terminal Arrangement 35.5 max. Panel Cutout Five 3 x 1.8 dia. holes 13.6+0.1 6 Terminal plate thickness: 0.3 36 max. 30.5+0.2 P2R-08A (2-pole) 7 0.3 5 5 35.5 max. 20 2.8 2.6 2.8 Eight 3 x 1.2 dia. holes 7 1.2 Recommended thickness of the panel is 1.6 to 2.0 mm 14.5 max. 7.5 Terminal plate thickness: 0.3 36 max. 157 G2R Mounting Height of Relay with Socket G2R Relay G2R Relay 36 P2R-_P Socket 30 P2R-_A Socket G2R Mounting Track PFP-100N, PFP-50N PFP-100N2 16 7.3+0.15 4.5 35+0.3 15 25 10 25 L 25 10 25 * 27+0.15 1 15 25 10 25 L 25 10 25 15 4.5 35+0.3 27 24 1 29.2 1.5 It is recommended to use a panel 1.6 to 2.0 mm thick. L: Length 1m PFP-100N 50 cm PFP-50N 1m PFP-100N2 End Plates PFP-M 10 6.2 1.8 Spacers PFP-S 5 16 12 1 50 1.8 35.5 35.3 44.3 34.8 11.5 10M4 x 8 pan head screw 1.3 4.8 16.5 Mounting Plates P2R-P 90 R2.25 10 elliptic holes 4.5 13.6 3.4 49 42+0.1 30.5 Square hole 18+0.15 9+0.1 18+0.15 9+0.1 18+0.15 18+0.15 t = 1.6 mm 72+0.2 158 G2R G2R Precautions I Mounting The above minimum mounting space is necessary due to mutual thermal interference generated by the relays. This restriction may be ignored, however, depending on the operating conditions of the relays. Consult OMRON for details. There is no restriction on the mounting direction of each relay on the PCB. When using this circuit, confirm the set and reset states and then take into account the circuit constant. When mounting a number of relays on a PCB, be sure to provide a minimum mounting space of 5 mm between the two juxtaposed relays as shown below. 5 mm min. 5 mm min. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. K013-E1-11B 159
G2R-1-SND 价格&库存

很抱歉,暂时无法提供与“G2R-1-SND”相匹配的价格&库存,您可以联系我们找货

免费人工找货