G5Q-1A4-EL3-HADC12

G5Q-1A4-EL3-HADC12

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    RELAYGENPURPOSSPST-NO10A12V

  • 数据手册
  • 价格&库存
G5Q-1A4-EL3-HADC12 数据手册
G5Q-EL/-EL2/-EL3 PCB Power Relay A Miniature Power Relay with high performance • IEC/EN 60335-1 conformed. • Coil insulation system: class F (UL1446) • [Type G5Q-EL] Higher performance compare with G5Q standard type. Minimum 100,000 operations durability at 10 A (250 VAC) switching. • [Type G5Q-EL2] High inrush capacity performance (Inrush current 40 A). UL508 TV3 conformed. • [Type G5Q-EL3] Ideal for motor switching 3 A with high inrush 30 A IEC/EN 60079-15 conformed. RoHS Compliant ■Model Number Legend ■Application Examples 6 4. Classification EL : For Resistive load EL2 : For Inrush load EL3 : For Motor load 2. Contact Form A : SPST-NO (1a) Home appliances Building automation Lighting control Output of control system FA I/O module - 1 2 3 4 5 1. Number of Pole 1 : 1-pole • • • • • - G 5 Q -@ @ @- @- @ -@ ——— — — — G 5 Q E L / E L 2 / E L 3 - 5. Market Code HA : Home Appliance according to IEC/EN60335-1 3. Enclosure rating None : Flux protection (-EL type only) 4 : Fully sealed (-EL2, -EL3) 6. Case Vent Hole None : No vent hole VH : Vent hole (-EL type only) ■Ordering Information Classification Contact form Enclosure rating Model Rated coil voltage G5Q-1A-EL-HA-VH 5 VDC 12 VDC 24 VDC Sealed G5Q-1A4-EL2-HA 5 VDC 12 VDC 24 VDC Sealed G5Q-1A4-EL3-HA 5 VDC 12 VDC 24 VDC -EL type (For Resistive load) SPST-NO (1a) Flux protection (Vent hole type) -EL2 type (For Inrush load) SPST-NO (1a) -EL3 type (For Motor load) SPST-NO (1a) Minimum packing unit 100 pcs/tray Note 1. When ordering, add the rated coil voltage to the model number. Example: G5Q-1A4-EL2-HA DC12 Rated coil voltage Note 2. Contact your OMRON sales representative for tube packing models. ■Ratings ●Coil Rated voltage Rated current (mA) Coil resistance (Ω) 5 VDC 80.0 63 12 VDC 33.3 360 24 VDC 16.7 1440 Must operate voltage (V) Must release voltage (V) Max. voltage (V) % of rated voltage 75% max. 5% min. 190% (at 23°C) Power consumption (mW) Approx. 400 Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. Note 2. The operating characteristics are measured at a coil temperature of 23°C. Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil. Note 4. 5 VDC of coil rated voltage is available only for –EL3 1 G5Q-EL/-EL2/-EL3 PCB Power Relay ●Contacts Load -EL type (For Resistive load) -EL2 type (For Inrush load) -EL3 type (For Motor load) SPST-NO (1a) Item Flux protection Sealed Contact type Single Contact material Ag-Alloy (Cd free) Rated load Resistive load:10 A at 250 VAC Rated carry current 10 A Max. rated voltage 277 VAC Max. rated current 10 A AC Sealed Capacitive load:Inrush 40 A (100 μs) / 1 A break at 250 VAC Motor load : Inrush 30 A (0.5 s) / 3 A break cosφ=0.5 at 250 VAC ■Characteristics Item Classification Contact resistance *1 Operate time 10 ms max. Release time 5 ms max. Insulation resistance *2 Dielectric strength Impulse withstand voltage -EL2 type (For Inrush load) -EL3 type (For Motor load) 1,000 MΩ min. (at 500 VDC) Between coil and contacts 4,000 VAC, 50/60 Hz for 1 min Between contacts of the same polarity 1,000 VAC, 50/60 Hz for 1 min Between coil and contacts 8 kV (1.2 x 50 μs) Destruction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Malfunction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Destruction 1,000 m/s2 Malfunction 100 m/s2 - G 5 Q E L / E L 2 / E L 3 -EL type (For Resistive load) 100 mΩ max. Vibration resistance Shock resistance 10,000,000 operations (18,000 operations per hour) Electrical Resistive load 100,000 operations at 23°C (operation: ON for 1 sec. OFF for 9 sec.) - Mechanical Durability Capacitive load 100,000 operations at 23°C (operation: ON for 1 sec. OFF for 3 sec.) Failure rate (P level) (reference *3) 10 mA at 5 VDC Ambient operating temperature -40°C to 85°C (with no icing or condensation) Ambient operating humidity 5% to 85% Weight Approx. 6.5 g Motor load 300,000 operations at 23°C (operation: ON for 1 sec. OFF for 1 sec.) Note. Values in the above table are the initial values at 23°C. *1. The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method. *2. Testing conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the electric strength was measured. *3. This value was measured at switching frequency of 120 operation/min. ■Engineering Data ●Ambient Temperature VS. Maximum Coil Voltage Maximum coil voltage (% of rated) Switching current (A) ●Maximum Switching Capacity (AC) 100 AC resistive load 10 ●Shock Malfunction Y 200 1,000 180 160 X 1,000 140 Z 1,000 120 Energized 100 De-energized 200 80 1,000 Z′ 60 800 1,000 X′ 40 1,000 Y′ 20 1 1 10 100 1000 Switching voltgate (V) 0 -40 -20 0 20 23 40 60 80 100 Ambient temperature (°C) Note. The Maximum coil voltage refers to the maximum value in a varying of operating power voltage, not a continuous voltage. 2 120 Unit: m/s2 Shock direction Sample: G5Q-1A-EL-HA-VH X X' Number of Relays: 5 pcs Y Test conditions: Shock is applied Z in ±X, ±Y, and ±Z directions three Z' times each with without energizing the Relays to check Y' the number of malfunctions. Requirement: None malfuction 100 m/s2 G5Q-EL/-EL2/-EL3 PCB Power Relay ■Actual Load Life (Reference Values) G5Q-1A4-EL2-HA 120 VAC Capacitive load Inrush: 56 A (0-P), Break: 0.2 A (rms) 200,000 operations min. (Ambient temperature: 23°C) ■Dimensions (Unit: mm) G5Q-1A-EL-HA-VH G5Q-1A4-EL2-HA G5Q-1A4-EL3-HA PCB Mounting Holes (Bottom View) Tolerance: ±0.1 mm 10.3MAX (10.0)* 20.3MAX (20.0)* . .1 (1.18) 3 -1. ±0 dia Terminal Arrangement/ Internal Connections (Bottom View) 4 (1.19) 1 2 3 7.62±0.1 15.8MAX (15.5)* 5 7.62±0.1 0.4 0.32 MAX 0.27 MAX 3.4 0.4 x 0.4 (No coil polarity) 10.16±0.1 1 7.62 10.16 * Average value 7.62 ■Approved Standards UL Recognized: CSA Certified: G 5 Q E L / E L 2 / E L 3 (File No. E41515) (File No. LR31928) - Model Coil ratings 5, 12, 24 VDC G5Q-1A4-EL2-HA 5, 12, 24 VDC EN/IEC, VDE 5, 12, 24 VDC 10 A 250 VAC Resistive 40°C 6,000 5 A 250 VAC Resistive 85°C 6,000 TV-3 40°C 25,000 1 A 120 VAC 30 A Inrush-max. 1 msec 85°C 25,000 10 A 250 VAC Resistive 40°C 50,000 1/2HP 250 VAC 40°C 50,000 1/6HP 125 VAC 40°C 50,000 - G5Q-1A4-EL3-HA Number of test operations - G5Q-1A-EL-HA-VH Contact ratings (Certified/No.40009467) Model G5Q-1A-EL-HA-VH Coil ratings 5, 12, 24 VDC G5Q-1A4-EL2-HA 5, 12, 24 VDC G5Q-1A4-EL3-HA 5, 12, 24 VDC Contact ratings Number of test operations 10 A 250 VAC (cosφ=1) 105°C 10,000 5 A 250 VAC (cosφ=1) 85°C 10,000 Peak inrush 30 A / Break 1 A 230 VAC 85°C 25,000 3 A 250 VAC (cosφ=0.4) 85°C 50,000 Creepage distance 6.4 mm min. Clearance distance 5.5 mm min. Insulation material group IIIa Type of insulation coil-contact circuit open contact circuit Reinforced Micro disconnection Rated Insulation voltage 250 V Pollution degree 2 Rated voltage system 250 V Over voltage category III Category of protection according to IEC 61810-1 RT II (Flux protection) / RT III (Sealed) Glow wire according to IEC 60335-1 ed.5 GWT 750°C min. (IEC 60695-2-11) / GWFI 850°C min. (IEC 60695-2-12) Tracking resistance according to IEC 60112 PTI 250 V min. (housing parts) Flammability class according to UL94 V-0 Coil Insulation system F Class (UL 1446) ■Precautions ●Please refer to “PCB Relays Common Precautions” for correct use. 3 G5Q-EL/-EL2/-EL3 PCB Power Relay - G 5 Q E L / E L 2 / E L 3 • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation Electronic and Mechanical Components Company 4 Contact: www.omron.com/ecb Cat. No. K284-E1-04 0118(0416)(O)
G5Q-1A4-EL3-HADC12 价格&库存

很抱歉,暂时无法提供与“G5Q-1A4-EL3-HADC12”相匹配的价格&库存,您可以联系我们找货

免费人工找货