G5Q-EL/-EL2/-EL3
PCB Power Relay
A Miniature Power Relay
with high performance
• IEC/EN 60335-1 conformed.
• Coil insulation system: class F (UL1446)
• [Type G5Q-EL]
Higher performance compare with G5Q standard type.
Minimum 100,000 operations durability at 10 A (250 VAC) switching.
• [Type G5Q-EL2]
High inrush capacity performance (Inrush current 40 A).
UL508 TV3 conformed.
• [Type G5Q-EL3]
Ideal for motor switching 3 A with high inrush 30 A
IEC/EN 60079-15 conformed.
RoHS Compliant
■Model Number Legend
■Application Examples
6
4. Classification
EL : For Resistive load
EL2 : For Inrush load
EL3 : For Motor load
2. Contact Form
A : SPST-NO (1a)
Home appliances
Building automation
Lighting control
Output of control system
FA I/O module
-
1 2 3 4 5
1. Number of Pole
1 : 1-pole
•
•
•
•
•
-
G 5 Q -@ @ @- @- @ -@
——— — — —
G
5
Q
E
L
/
E
L
2
/
E
L
3
-
5. Market Code
HA : Home Appliance according
to IEC/EN60335-1
3. Enclosure rating
None : Flux protection
(-EL type only)
4 : Fully sealed
(-EL2, -EL3)
6. Case Vent Hole
None : No vent hole
VH : Vent hole (-EL type only)
■Ordering Information
Classification
Contact form
Enclosure rating
Model
Rated coil voltage
G5Q-1A-EL-HA-VH
5 VDC
12 VDC
24 VDC
Sealed
G5Q-1A4-EL2-HA
5 VDC
12 VDC
24 VDC
Sealed
G5Q-1A4-EL3-HA
5 VDC
12 VDC
24 VDC
-EL type
(For Resistive load)
SPST-NO (1a)
Flux protection
(Vent hole type)
-EL2 type
(For Inrush load)
SPST-NO (1a)
-EL3 type
(For Motor load)
SPST-NO (1a)
Minimum packing unit
100 pcs/tray
Note 1. When ordering, add the rated coil voltage to the model number.
Example: G5Q-1A4-EL2-HA DC12
Rated coil voltage
Note 2. Contact your OMRON sales representative for tube packing models.
■Ratings
●Coil
Rated voltage
Rated current
(mA)
Coil resistance
(Ω)
5 VDC
80.0
63
12 VDC
33.3
360
24 VDC
16.7
1440
Must operate voltage (V)
Must release voltage (V)
Max. voltage (V)
% of rated voltage
75% max.
5% min.
190%
(at 23°C)
Power consumption
(mW)
Approx. 400
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
Note 2. The operating characteristics are measured at a coil temperature of 23°C.
Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
Note 4. 5 VDC of coil rated voltage is available only for –EL3
1
G5Q-EL/-EL2/-EL3
PCB Power Relay
●Contacts
Load
-EL type (For Resistive load)
-EL2 type (For Inrush load)
-EL3 type (For Motor load)
SPST-NO (1a)
Item
Flux protection
Sealed
Contact type
Single
Contact material
Ag-Alloy (Cd free)
Rated load
Resistive load:10 A at 250 VAC
Rated carry current
10 A
Max. rated voltage
277 VAC
Max. rated current
10 A AC
Sealed
Capacitive load:Inrush 40 A (100 μs) /
1 A break at 250 VAC
Motor load : Inrush 30 A (0.5 s) /
3 A break cosφ=0.5 at 250 VAC
■Characteristics
Item
Classification
Contact resistance *1
Operate time
10 ms max.
Release time
5 ms max.
Insulation resistance *2
Dielectric strength
Impulse withstand
voltage
-EL2 type (For Inrush load)
-EL3 type (For Motor load)
1,000 MΩ min. (at 500 VDC)
Between coil and
contacts
4,000 VAC, 50/60 Hz for 1 min
Between contacts of the
same polarity
1,000 VAC, 50/60 Hz for 1 min
Between coil and
contacts
8 kV (1.2 x 50 μs)
Destruction
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Destruction
1,000 m/s2
Malfunction
100 m/s2
-
G
5
Q
E
L
/
E
L
2
/
E
L
3
-EL type (For Resistive load)
100 mΩ max.
Vibration resistance
Shock resistance
10,000,000 operations (18,000 operations per hour)
Electrical
Resistive load
100,000 operations at 23°C
(operation: ON for 1 sec. OFF for 9
sec.)
-
Mechanical
Durability
Capacitive load
100,000 operations at 23°C
(operation: ON for 1 sec. OFF for 3
sec.)
Failure rate (P level) (reference *3)
10 mA at 5 VDC
Ambient operating temperature
-40°C to 85°C (with no icing or condensation)
Ambient operating humidity
5% to 85%
Weight
Approx. 6.5 g
Motor load
300,000 operations at 23°C
(operation: ON for 1 sec. OFF for 1
sec.)
Note. Values in the above table are the initial values at 23°C.
*1. The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method.
*2. Testing conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the electric strength was measured.
*3. This value was measured at switching frequency of 120 operation/min.
■Engineering Data
●Ambient Temperature VS.
Maximum Coil Voltage
Maximum coil voltage (% of rated)
Switching current (A)
●Maximum Switching Capacity
(AC)
100
AC resistive load
10
●Shock Malfunction
Y
200
1,000
180
160
X
1,000
140
Z
1,000
120
Energized
100
De-energized
200
80
1,000
Z′
60
800
1,000
X′
40
1,000
Y′
20
1
1
10
100
1000
Switching voltgate (V)
0
-40
-20
0
20 23 40
60
80
100
Ambient temperature (°C)
Note. The Maximum coil voltage refers to the
maximum value in a varying of operating
power voltage, not a continuous voltage.
2
120
Unit: m/s2
Shock direction
Sample: G5Q-1A-EL-HA-VH
X
X'
Number of Relays: 5 pcs
Y
Test conditions: Shock is applied
Z
in ±X, ±Y, and ±Z directions three
Z'
times each with without
energizing the Relays to check Y'
the number of malfunctions.
Requirement: None malfuction
100 m/s2
G5Q-EL/-EL2/-EL3
PCB Power Relay
■Actual Load Life (Reference Values)
G5Q-1A4-EL2-HA
120 VAC Capacitive load
Inrush: 56 A (0-P), Break: 0.2 A (rms)
200,000 operations min. (Ambient temperature: 23°C)
■Dimensions
(Unit: mm)
G5Q-1A-EL-HA-VH
G5Q-1A4-EL2-HA
G5Q-1A4-EL3-HA
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
10.3MAX
(10.0)*
20.3MAX
(20.0)*
.
.1
(1.18)
3
-1.
±0
dia
Terminal Arrangement/
Internal Connections
(Bottom View)
4
(1.19)
1
2
3
7.62±0.1
15.8MAX
(15.5)*
5
7.62±0.1
0.4
0.32
MAX
0.27
MAX
3.4
0.4 x 0.4
(No coil polarity)
10.16±0.1
1
7.62
10.16
* Average value
7.62
■Approved Standards
UL Recognized:
CSA Certified:
G
5
Q
E
L
/
E
L
2
/
E
L
3
(File No. E41515)
(File No. LR31928)
-
Model
Coil ratings
5, 12, 24 VDC
G5Q-1A4-EL2-HA
5, 12, 24 VDC
EN/IEC, VDE
5, 12, 24 VDC
10 A 250 VAC Resistive 40°C
6,000
5 A 250 VAC Resistive 85°C
6,000
TV-3 40°C
25,000
1 A 120 VAC 30 A Inrush-max. 1 msec 85°C
25,000
10 A 250 VAC Resistive 40°C
50,000
1/2HP 250 VAC 40°C
50,000
1/6HP 125 VAC 40°C
50,000
-
G5Q-1A4-EL3-HA
Number of test
operations
-
G5Q-1A-EL-HA-VH
Contact ratings
(Certified/No.40009467)
Model
G5Q-1A-EL-HA-VH
Coil ratings
5, 12, 24 VDC
G5Q-1A4-EL2-HA
5, 12, 24 VDC
G5Q-1A4-EL3-HA
5, 12, 24 VDC
Contact ratings
Number of test
operations
10 A 250 VAC (cosφ=1) 105°C
10,000
5 A 250 VAC (cosφ=1) 85°C
10,000
Peak inrush 30 A / Break 1 A 230 VAC 85°C
25,000
3 A 250 VAC (cosφ=0.4) 85°C
50,000
Creepage distance
6.4 mm min.
Clearance distance
5.5 mm min.
Insulation material group
IIIa
Type of insulation coil-contact circuit
open contact circuit
Reinforced
Micro disconnection
Rated Insulation voltage
250 V
Pollution degree
2
Rated voltage system
250 V
Over voltage category
III
Category of protection according to IEC 61810-1
RT II (Flux protection) / RT III (Sealed)
Glow wire according to IEC 60335-1 ed.5
GWT 750°C min. (IEC 60695-2-11) / GWFI 850°C min. (IEC 60695-2-12)
Tracking resistance according to IEC 60112
PTI 250 V min. (housing parts)
Flammability class according to UL94
V-0
Coil Insulation system
F Class (UL 1446)
■Precautions
●Please refer to “PCB Relays Common Precautions” for correct use.
3
G5Q-EL/-EL2/-EL3
PCB Power Relay
-
G
5
Q
E
L
/
E
L
2
/
E
L
3
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
4
Contact: www.omron.com/ecb
Cat. No. K284-E1-04