0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
G6CU-1117P-US-DC24

G6CU-1117P-US-DC24

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    RELAY_19.9X14.9MM_TM

  • 描述:

    RELAY GEN PURPOSE SPST 10A 24V

  • 数据手册
  • 价格&库存
G6CU-1117P-US-DC24 数据手册
G6C PCB Power Relay Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A • SPST-NO 10A and SPST-NO + SPST-NC 8A for power switching and output that satisfy the needs for space-saving. • Small High-capacity Relays Compact: 20 × 15 × 10 mm (L × W × H). • Low power consumption: 200 mW. • Ultrasonically cleanable models is available. • Exclusive P6C model for sockets is now available. RoHS Compliant ■Model Number Legend ■Application Examples G6C- @- @ @ @ @@- @- @-@- @ 1 2 3 4 5 6 7 8 1. Relay Function None: Single-side stable U : Single-winding latching K : Double-winding latching 2. Contact Form 11: SPST-NO (1a) 21: SPST-NO (1a) + SPST-NC (1b) 3. Contact Type 1: Single 4. Enclosure rating 4: Fully sealed 7: Flux protection 5. Terminal Shape P: PCB terminals Socket mounting Terminals C: Self-clinching PCB Ideal for output applications of control equipments 9 6. Contact Material None: Standard (Ag-alloy (Cd free)) FD : AgSnIn Contacts (Suitable for DC inductive load with high inrush current) 7. Approved Standards US: UL/CSA 8. Washability None: Standard model (not compatible with ultrasonically cleanable models) U : For ultrasonically cleanable 9. Mounting None: Mounted directly to PCB P6C : Mounted to Socket 1 G 6 C G6C PCB Power Relay ■Ordering Information ●Standard Models (UL, CSA certified) Relay Function Enclosure rating Contact form Terminals Single-side stable Model G6C-1117P-US Straight PCB SPST-NO (1a) G6C-1117P-FD-US Self-clinching PCB G6C-1117C-US Flux protection Rated coil voltage Single-winding latching Model Straight PCB SPST-NO (1a) + SPST-NC (1b) G 6 C G6C-2117P-FD-US 3 VDC 3 VDC 3 VDC 5 VDC 5 VDC 6 VDC G6CU-1117P-US Relay Function Enclosure rating Contact form Terminals G6C-2117C-US G6C-1114P-US Straight PCB SPST-NO (1a) G6C-1114P-FD-US Self-clinching PCB G6C-1114C-US Fully sealed 24 VDC 24 VDC 24 VDC 5 VDC 5 VDC 12 VDC G6CU-1117P-FD-US Straight PCB SPST-NO (1a) + SPST-NC (1b) G6C-2114P-FD-US G6C-2114C-US − G6CK-1117P-FD-US − 24 VDC 3 VDC − − 5 VDC − − 12 VDC − − G6CK-1117C-US 12 VDC 24 VDC − 24 VDC 3 VDC 3 VDC 3 VDC 6 VDC 5 VDC G6CU-2117P-US 6 VDC 6 VDC 12 VDC 12 VDC 12 VDC 24 VDC 24 VDC 24 VDC 5 VDC 5 VDC 12 VDC G6CU-2117P-FD-US 12 VDC 5 VDC G6CK-2117P-FD-US 24 VDC − 24 VDC 3 VDC − 3 VDC 5 VDC 5 VDC 5 VDC 6 VDC G6CU-2117C-US − G6CK-2117C-US − 12 VDC 12 VDC 12 VDC 24 VDC − 24 VDC Rated coil voltage Single-winding latching Model Double-winding latching Rated coil voltage Model Rated coil voltage 3 VDC 3 VDC 3 VDC 5 VDC 5 VDC 5 VDC 6 VDC G6CU-1114P-US 6 VDC G6CK-1114P-US 12 VDC 12 VDC 24 VDC 24 VDC 24 VDC 5 VDC 5 VDC G6CU-1114P-FD-US 12 VDC 5 VDC G6CK-1114P-FD-US 12 VDC 24 VDC 24 VDC 3 VDC − 3 VDC 5 VDC − 5 VDC 12 VDC G6CU-1114C-US 12 VDC 24 VDC G6CK-1114C-US 12 VDC 24 VDC − 24 VDC 3 VDC 3 VDC 3 VDC 6 VDC 5 VDC G6CU-2114P-US 6 VDC 5 VDC G6CK-2114P-US 6 VDC 12 VDC 12 VDC 12 VDC 24 VDC 24 VDC 24 VDC 5 VDC 5 VDC 12 VDC G6CU-2114P-FD-US 12 VDC − G6CK-2114P-FD-US 24 VDC − 24 VDC 3 VDC − − 5 VDC 5 VDC 5 VDC 6 VDC G6CU-2114C-US − Minimun packing unit 6 VDC 12 VDC 12 VDC 100 pcs/ tray 5 VDC G6CK-2117P-US G6CK-2114C-US 6 VDC 12 VDC − 12 VDC 24 VDC − 24 VDC Note. When ordering, add the rated coil voltage to the model number. Example: G6C-1117P-US DC3 Rated coil voltage However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC. 2 12 VDC 24 VDC 24 VDC Self-clinching PCB 12 VDC Minimun packing unit 6 VDC 12 VDC 5 VDC G6C-2114P-US G6CK-1117P-US 12 VDC Single-side stable Model − 12 VDC 24 VDC Self-clinching PCB Model Rated coil voltage 5 VDC 5 VDC G6C-2117P-US Double-winding latching Rated coil voltage 100 pcs/ tray G6C PCB Power Relay ●Ultrasonically Cleanable Models (UL, CSA certified) Relay Function Enclosure rating Contact form Terminals Straight PCB Single-side stable Model G6C-1114P-US-U SPST-NO (1a) Fully sealed Rated coil voltage Single-winding latching Model G6C-1114C-US-U Straight PCB G6C-2114P-US-U Self-clinching PCB G6C-2114C-US-U Model Rated coil voltage − − 5 VDC 5 VDC 5 VDC 6 VDC G6CU-1114P-US-U − G6CK-1114P-US-U 12 VDC 24 VDC − 24 VDC 12 VDC − 24 VDC − 12 VDC − − − − − − − 12 VDC − − 5 VDC − − − − − 24 VDC 100 pcs/ tray 5 VDC G6CK-2114P-US-U 24 VDC 12 VDC Minimun packing unit − 12 VDC 5 VDC SPST-NO (1a) + SPST-NC (1b) Double-winding latching 3 VDC 12 VDC Self-clinching PCB Rated coil voltage − − − Note. When ordering, add the rated coil voltage to the model number. Example: G6C-1114P-US-U DC3 Rated coil voltage However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC. ●Connecting Sockets (Sold Separately) Applicable relays Model G6C-2114P-US-P6C G6C-2117P-US-P6C G6C-1114P-US-P6C G6C-1117P-US-P6C G6CU-2114P-US-P6C G6CU-2117P-US-P6C G6CU-1114P-US-P6C G6CU-1117P-US-P6C P6C-06P G6CK-2114P-US-P6C G6CK-2117P-US-P6C G6CK-1114P-US-P6C G6CK-1117P-US-P6C P6C-08P Removal Tool P6B-Y1 Hold-down Clips P6B-C2 G 6 C Minimun packing unit 20 pcs/tube 1 Note 1. Use the G6C-@@@@P-US-P6C to mount to a P6C Socket. 2. When using by combining sockets, the rated current will be 5A due to its rated switching current. 3 G6C PCB Power Relay ■Ratings Coil: 1-Pole, Single-side Stable Type (Including models for ultrasonically cleanable) Item Rated current (mA) Rated voltage Must operate Must release voltage voltage (V) (V) Coil resistance (Ω) 3 VDC 67 45 5 VDC 40 125 6 VDC 33.3 180 12 VDC 16.7 720 24 VDC 8.3 2,880 Max. voltage (V) Power consumption (mW) % of rated voltage 70% max. 10% min. 160% (at 23°C) Approx. 200 Coil: Single-winding Latching Type (Including models for ultrasonically cleanable) Item Rated current (mA) Rated voltage Coil resistance (Ω) 3 VDC 67 45 5 VDC 40 125 6 VDC 33.3 180 12 VDC 16.7 720 24 VDC 8.3 2,880 Must set voltage (V) Must reset voltage (V) Max. voltage (V) % of rated voltage 70% max. 70% max. 160% (at 23°C) Power consumption Set coil (mW) Reset coil (mW) 200 200 Coil: Double-winding Latching Type (Including models for ultrasonically cleanable) Item G 6 C Rated current (mA) Set coil Reset coil Coil resistance (Ω) Set coil Reset coil Must set voltage (V) Rated voltage Must reset voltage (V) Max. voltage (V) Power consumption % of rated voltage 3 VDC 93.5 93.5 32.1 5 VDC 56.0 56.0 89.3 6 VDC 46.7 46.7 129 129 12 VDC 23.3 23.3 514 514 24 VDC 11.7 11.7 2,056 2,056 Set coil (mW) Reset coil (mW) 280 280 32.1 89.3 70% max. 70% max. 130% (at 23°C) Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2. The operating characteristics are measured at a coil temperature of 23°C. 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil. Contact Contact Form Rated load Item SPST-NO (1a) Inductive load (cosφ = 0.4; L/R = 7 ms) Resistive load Inductive load (cosφ = 0.4; L/R = 7 ms) 10 A (8 A) at 250 VAC 10 A (10 A) at 30 VDC 5 A (5 A) at 250 VAC 5 A (5 A) at 30 VDC 8 A (8 A) at 250 VAC 8 A (8 A) at 30 VDC 3.5 A (3.5 A) at 250 VAC 3.5 A (3.5 A) at 30 VDC Contact type Single Contact material Rated carry current Ag-Alloy (Cd free) 10 A (10 A) Max. switching voltage Max. switching current 8 A (8 A) 380 VAC, 125 VDC 10 A (10 A) Note. The values shown in parentheses ( ) are for -FD models only. 4 SPST-NO (1a) + SPST-NC (1b) Resistive load 8 A (8 A) G6C PCB Power Relay ■Characteristics (Including models for ultrasonically cleanable) Item Classification Contact resistance *1 Operate (set) time Release (reset) time Min. set pulse width Min. reset pulse width Between coil and contacts Between contacts of the same polarity Insulation resistance *2 Between contacts of different polarity Between set and reset coils Between coil and contacts Between contacts of the same polarity Dielectric strength Between contacts of different polarity Between set and reset coils Destruction Vibration resistance Malfunction Destruction Shock resistance Malfunction Mechanical Durability Electrical Failure rate (P level) (reference value) *3 Ambient operating temperature Ambient operating humidity Weight Single-side Stable Single-winding Latching Double-winding Latching 30 mΩ max. 10 ms max. 10 ms max. 20 ms (at 23°C) 20 ms (at 23°C) − − 1,000 MΩ min. 1,000 MΩ min. 1,000 MΩ min. (SPST-NO, SPST-NC) − − 1,000 MΩ min. 2,000 VAC 50/60Hz for 1min 1,000 VAC 50/60Hz for 1min 2,000 VAC 50/60Hz for 1min (SPST-NO, SPST-NC) 250 VAC 50/60Hz for 1min 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) 1,000 m/s2 100 m/s2 50,000,000 operations min. (at 18,000 operations/hr) 100,000 operation min. (at 1,800 operations/hr under rated load) 10 mA at 5 VDC -25°C to 70°C (with no icing or condensation) 5% to 85% Approx. 5.6 g − − Note. The given values are initial values. *1. Measurement conditions: 5 VDC, 1 A, voltage drop method. *2. Testing conditions: measured with a 500 VDC megohmmeter (at 250 VDC between set/reset coil). *3. This value was measured at a switching frequency of 120 operations/min. G 6 C ● Maximum Switching Capacity G6C-1114@-US G6C-1117@-US G6C-1114@-FD-US G6C-1117@-FD-US Switching current (A) Switching current (A) ■Engineering Data 50 30 AC resistive load 10 7 5 3 DC resistive load DC inductive load (L/R = 7 ms) 1 0.7 0.5 50 30 AC resistive load 10 8 5 3 2 AC inductive load (cosφ = 0.4) DC resistive load 1 0.7 0.5 0.3 0.3 0.2 0.2 0.1 DC inductive load (L/R = 7 ms) 0.1 1 3 5 7 10 30 50 100 250 380 1,000 1 3 5 7 10 30 50 100 Switching voltage (V) G6C-2114@-FD-US G6C-2117@-FD-US 50 30 AC resistive load 10 8 5 3 2 DC resistive load DC inductive load (L/R = 7 ms) 1 0.7 0.5 250 380 1,000 Switching voltage (V) AC inductive load (cosφ = 0.4) Switching current (A) G6C-2114@-US G6C-2117@-US Switching current (A) AC inductive load (cosφ = 0.4) 50 30 AC resistive load 10 8 5 3 2 1 0.7 0.5 0.3 0.3 0.2 0.2 0.1 AC inductive load (cosφ = 0.4) DC resistive load DC inductive load (L/R = 7 ms) 0.1 1 3 5 7 10 30 50 100 250 380 1,000 Switching voltage (V) 1 3 5 7 10 30 50 100 250 380 1,000 Switching voltage (V) 5 G6C ● Durability G6C-1114@-US, G6C-2114@-US G6C-1117@-US, G6C-2117@-US G6C-1114@-FD-US, G6C-2114@-FD-US G6C-1117@-FD-US, G6C-2117@-FD-US Durability (× 104 operations) Durability (x 104 operations) PCB Power Relay 500 300 G6C-2114@-US G6C-2117@-US 250 VAC resistive 30 VDC resistive 100 50 G6C-1114@-US G6C-1117@-US 250 VAC resistive 30 VDC resistive 30 10 300 100 G6C-2114@-FD-US G6C-2117@-FD-US 250 VAC resistive G6C-1114@-FD-US 30 VDC resistive G6C-1117@-FD-US 250 VAC resistive G6C-1114@ -FD-US G6C-1117@ -FD-US 30 VDC resistive 50 30 10 G6C-2114@-US 5 G6C-2117@-US 250 VAC inductive 3 (cosφ = 0.4) 30 VDC inductive (L/R = 7 ms) 1 500 0 1 2 3 4 G6C-1114@-US G6C-1117@-US 250 VAC inductive (cosφ = 0.4) 30 VDC inductive (L/R = 7 ms) 5 6 7 8 9 5 G6C-2114@-FD-US G6C-2117@-FD-US 3 250 VAC inductive (cosφ = 0.4) 30 VDC inductive (L/R = 7 ms) 1 0 1 2 3 4 10 11 G6C-1114@-FD-US G6C-1117@-FD-US 250 VAC inductive (cosφ = 0.4) 30 VDC inductive (L/R = 7 ms) 5 6 Switching current (A) 8 9 10 11 ● Ambient Temperature vs Must Operate and Must Release voltages Must Operate and Must Release voltages (%) Maximum coil voltage (%) ● Ambient Temperature vs. Maximum Coil Voltage 200 180 160 140 130 120 100 100 Must operate voltage Must release voltage max. X Sample: G6C-114P-US Number of Relays: 80 5 pcs min. 60 40 max. X min. 20 80 60 10 20 23 30 40 50 60 70 80 0 -40 90 -20 0 20 Ambient temperature (°C) 40 60 80 Ambient temperature (°C) Note. The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. ● Shock Malfunction Energized (a contact) Y ● Magnetic Interference (between Relays) De-energized (b contact) 600 600 400 400 X 600 Z 600 200 X 600 400 400 Z 600 200 400 200 200 Y 200 Z' 600 200 400 200 200 200 400 Change rate on the basis of rated value (OV) (%) G 6 C 7 Switching current (A) 200 500 600 X' 400 200 Z' 600 200 400 600 X' 400 400 Shock direction 600 Y' Unit: m/s2 600 Y' Unit: m/s2 Y X X' Z Z' Y' (coil) Sample: G6C-2114P-US DC24V Number of Relays: 6 pcs Test conditions: Shock is applied in ±X, ±Y, and ±Z directions three times each with without energizing the Relays to check the number of malfunctions. Requirement: 100 m/s2 6 3 2 1 max. X min. 0 l2 Sample -1 l1 -2 (Mounting pitch) -3 Initial l1=2.54a l2=5.08a l1=5.08a l2=7.62a l1=7.62a l2=10.16a G6C PCB Power Relay ■Dimensions Flux Protection Model (Straight PCB) G6C-@117P (-FD) -US 20 max. (19.9)* Terminal Arrangement/ Internal Connections (Bottom View) PCB Mounting Holes (Bottom View) Tolerance: ±0.1 15 max. (14.9)* 1-pole 10 max. 0.3 (9.9)* 0.9 0.9 10.16 7.62 * Average value 1.11 Four, 1.1-dia. holes 1-pole 2.54 3.5 0.65 2.54 1 0.5 10.16 (2.4) Dimensions in pointed brackets < > are for the Relay mounted to Socket (-P6C). 10.16 8 − 3 4 3 4 6 5 + 7.62 (1.1) Flux Protection Model (Self-clinching PCB) G6C-@117C-US 2-pole 2.54 20 max. (19.9)* Six, 1.1-dia. holes 15 max. (14.9)* 2-pole 2.54 1 10 max. 0.3 (9.9)* 3.2 3.5 0.65 10.16 0.9 7.62 0.9 1.11 (0.8)* 0.5 10.16 (2.4) 8 − + (1.0)* 10.16 7.62 (1.1) Note: Check carefully the coil polarity of the Relay. G 6 C * Average value Fully Sealed Model (Straight PCB) G6C-@114P (-FD) -US 20 max. (19.9)* PCB Mounting Holes 1-pole (Bottom View) Tolerance: ±0.1 15 max. (14.9)* 2.54 10 max. 0.3 (9.9)* Terminal Arrangement/ Internal Connections (Bottom View) Four, 1.1-dia. holes 1-pole 2.54 1 3.5 0.65 0.9 0.9 0.5 1.11 10.16 (2.4) 10.16 7.62 * Average value 10.16 8 − 3 4 3 4 6 5 + 7.62 (1.1) Dimensions in pointed brackets < > are for the Relay mounted to Socket (-P6C). 2-pole Fully Sealed Model (Self-clinching PCB) G6C-@114C-US 2.54 20 max. (19.9)* 15 max. (14.9)* Six, 1.1-dia. holes 2-pole 2.54 1 10 max. 0.3 (9.9)* 3.2 3.5 0.65 10.16 0.9 7.62 * Average value 0.9 1.11 (0.8)* 0.5 10.16 (2.4) (1.0)* 10.16 8 − + Note: Check carefully the coil polarity of the Relay. 7.62 (1.1) Note: Orientation marks are indicated as follows: 7 G6C PCB Power Relay Flux Protective Single-winding Latching Model (Straight PCB) G6CU-@117P (-FD) -US 20 max. (19.9)* PCB Mounting Holes (Bottom View) Tolerance: ±0.1 15 max. (14.9)* Terminal Arrangement/ Internal Connections (Bottom View) 1-pole 2.54 10 max. 0.3 (9.9)* Four, 1.1-dia. holes 1-pole 2.54 3.5 0.65 0.9 0.9 10.16 7.62 1.11 1 0.5 (2.4) Dimensions in pointed brackets < > are for the Relay mounted to Socket (-P6C). 8 10.16 4 + − S: Set coil R: Reset coil 7.62 (1.1) 2-pole 2.54 20 max. (19.9)* Six, 1.1-dia. holes 15 max. (14.9)* 2-pole 2.54 1 10max. 0.3 (9.9)* 3.2 3.5 0.65 10.16 G 6 C Fully Sealed Model Single Latching Models (Straight PCB) G6CU-@114P (-FD) -US 3 SR 10.16 * Average value Flux Protective Single-winding Latching Model (Self-clinching PCB) G6CU-@117C-US − + 0.9 7.62 0.9 1.11 (0.8)* 0.5 10.16 − + 3 4 6 5 SR (2.4) 8 + − (1.0)* 10.16 7.62 (1.1) Note: Check carefully the coil polarity of the Relay. * Average value 20 max. (19.9)* Terminal Arrangement/ Internal Connections (Bottom View) PCB Mounting Holes (Bottom View) Tolerance: ±0.1 15 max. (14.9)* 1-pole 2.54 10 max. 0.3 (9.9)* Four, 1.1-dia. holes 1-pole 2.54 1 3.5 0.65 0.9 10.16 7.62 * Average value 0.9 1.11 0.5 3 4 SR 10.16 (2.4) 10.16 Dimensions in pointed brackets < > are for the Relay mounted to Socket (-P6C). Fully Sealed Model Single Latching Models (Self-clinching PCB) G6CU-@114C-US − + 8 + − S: Set coil R: Reset coil 7.62 (1.1) 2-pole 2.54 20 max. (19.9)* Six, 1.1-dia. holes 15 max. (14.9)* 2-pole 2.54 1 10 max. 0.3 (9.9)* 3.2 3.5 0.65 10.16 0.9 7.62 * Average value 0.9 1.11 (0.8)* 0.5 10.16 − + 3 4 6 5 SR (2.4) 8 + − (1.0)* 10.16 7.62 (1.1) Note: Check carefully the coil polarity of the Relay. Note: Orientation marks are indicated as follows: 8 G6C PCB Power Relay Flux Protective Double-winding Latching Model (Straight PCB) G6CK-@117P (-FD) -US 20 max. (19.9)* PCB Mounting Holes (Bottom View) Tolerance: ±0.1 15 max. (14.9)* Terminal Arrangement/ Internal Connections (Bottom View) 1-pole 10 max. 0.3 (9.9)* 0.65 0.9 10.16 7.62 * Average value 0.9 1.11 Six, 1.1-dia. holes 1 0.5 (2.4) 2.54 7.62 8 20 max. (19.9)* 0.9 10.16 0.9 7.62 * Average value 15 max. (14.9)* Eight, 1.1-dia. holes 3 4 6 5 R 7 + 2-pole 1 0.9 1.11 (2.4) (0.8)* 0.9 10.16 7.62 * Average value 2 (1.0)* 0.5 10.16 7.62 7.62 2.54 (1.1) 8 + − R 7 + Note: Check carefully the coil polarity of the Relay. G 6 C 20 max. (19.9)* 0.9 − S PCB Mounting Holes (Bottom View) Tolerance: ±0.1 15 max. (14.9)* Terminal Arrangement/ Internal Connections (Bottom View) 1-pole 2.54 Six, 1.1-dia. holes 3.5 0.9 1.11 1-pole 2.54 1 0.5 − 2 S 10.16 (2.4) Dimensions in pointed brackets < > are for the Relay mounted to Socket (-P6C). 7.62 + − 3 4 3 4 6 5 R 7 + S: Set coil R: Reset coil 7.62 2.54 8 (1.1) 2-pole 2.54 20 max. (19.9)* Eight, 1.1-dia. holes 15 max. (14.9)* 2-pole 2.54 1 10 max. 0.3 (9.9)* 3.2 0.65 4 2.54 10 max. 0.3 (9.9)* Fully Sealed Double-winding Latching Model (Self-clinching PCB) G6CK-@114C-US 3 (1.1) 2.54 3.5 0.65 + − 2-pole 3.2 Fully Sealed Double-winding Latching Model (Straight PCB) G6CK-@114P (-FD) -US 2 S: Set coil R: Reset coil 7.62 10 max. 0.3 (9.9)* 0.65 − S 10.16 Dimensions in pointed brackets < > are for the Relay mounted to Socket (-P6C). Flux Protective Double-winding Latching Model (Self-clinching PCB) G6CK-@117C-US 1-pole 2.54 3.5 0.9 2.54 3.5 0.9 0.9 10.16 7.62 * Average value 0.9 1.11 (0.8)* 0.5 10.16 − 2 S (2.4) (1.0)* 7.62 2.54 7.62 (1.1) 8 + − R 7 + Note: Check carefully the coil polarity of the Relay. Note: Orientation marks are indicated as follows: 9 G6C PCB Power Relay ■Connecting Sockets Dimensions Socket for single-winding latching/single-side a table Models P6C-06P PCB Mounting Holes (BOTTOM VIEW) Tolerance: ±0.1 mm 23.2max. (23)* 15max. (14.9)* Six, 1.1-dia. holes 2.54 3.1 2.54 (2.4) 10.8max. (10.6)* 7.5 3.5 0.8 10.16 * Average value 0.4 7.62 (2.61) 10.16 7.62 10.16±0.1 Socket for double-winding latching Models P6C-08P 23.2max. (23)* PCB Mounting Holes (BOTTOM VIEW) Tolerance: ±0.1 mm 15max. (14.9)* G 6 C 3.1 Eight, 1.1-dia. holes 2.54 2.54 (2.4) 10.8max. (10.6)* 7.5 3.5 0.8 * Average value 2.54 7.62 7.62 0.4 10.16±0.1 7.62 (2.61) 7.62 2.54 Note: Orientation marks are indicated as follows: 10 G6C PCB Power Relay ■Removal Tool ■Hold-down Clips P6B-Y1 P6B-C2 ■Approved Standards ●The rated values approved by each of the safety standards may be different from the performance characteristics individually defined in this catalog. UL Recognized CSA Certified Model (File No. E41643) (File No. LR31928) Number of poles Contact ratings Number of test operations 10 A, 250 VAC (General use) 80°C 10 A, 30 VDC (Resistive) 80°C 1/6 HP 125 VAC, 1/4 HP, 125 VAC 80°C 1/3 HP 250 VAC, 1/4 HP, 250 VAC 80°C 600 W, 120 VAC, (Tungsten) 80°C (excluding -FD Models) 6,000 530 VA, 20 to 265 VAC Max 2A (Pilot Duty) 80°C 43.2 VA, 30 VDC (Pilot Duty) 80°C 6,000 Coil ratings 1 12 LRA, 2.2 FLA, 30 VDC 80°C G6C ( ) 3 to 24 VDC 2 EN/IEC, VDE Certified Model Number of poles 6,000 530 VA, 20 to 265 VAC Max 2A (Pilot Duty) 80°C 43.2 VA, 30 VDC (Pilot Duty) 80°C 6,000 Coil ratings 3, 5, 6, 12, 24 VDC 2 • Single-stable: 3, 5, 6, 12, 24 VDC EN/IEC, TÜV Certified Model Number of poles 1 G6C ( ) 2 30,000 1,000 (-FD Models) (Certificate No. 40014439) 1 G6C ( ) 30,000 1,000 (-FD Models) 8 A, 250 VAC (General use) 80°C 8 A, 30 VDC (Resistive) 80°C 1/6 HP 125 VAC, 1/4 HP, 125 VAC 80°C 1/3 HP 250 VAC, 1/4 HP, 250 VAC 80°C 600 W, 120 VAC, (Tungsten) 80°C (excluding -FD Models) 12 LRA, 2.2 FLA, 30 VDC 80°C G 6 C Contact ratings 10 A, 250 VAC (cosφ = 1) 40°C 5 A, 250 VAC (cosφ = 0.4) 40°C 7 A, 250 VAC (cosφ = 1) 40°C 3.5 A, 250 VAC (cosφ = 0.4) 40°C Approved switching operations 20,000 (Registration No. R50158249) Coil ratings • Single-stable: 3, 5, 6, 12, 24 VDC • Latching: 3, 5, 6, 12, 24 VDC Contact ratings 10 A, 250 VAC (cosφ = 1) 40°C 5 A, 250 VAC (cosφ = 0.4) 40°C 10 A, 30 VDC (L/R = 0 ms) 40°C 8 A, 250 VAC (cosφ = 1) 40°C 3.5 A, 250 VAC (cosφ = 0.4) 40°C 8 A, 30 VDC (L/R = 0 ms) 40°C Approved switching operations 20,000 11 G6C PCB Power Relay ■Precautions ●Please refer to “PCB Relays Common Precautions” for correct use. Correct Use ●Mounting • Do not reverse the polarity of the coil (+, −). • When mounting more than two relays side by side, keep the gap between Relays as shown below to ensure a good heat dissipation. It may result in malfunction if heat is not dissipated smoothly from the Relay. 2.54 mm × 3 pitch min. between terminals 2.54 mm × 2 pitch min. between terminals G 6 C ●Sockets 17 mm max. for sockets 7.5 mm • When mounting the Relay, make sure to insert the Relay terminals perpendicularly and correctly into the socket contact pin. • Hold-down clips (for mounting and removal) are also available. • The P6C model has a flux-resistant construction. Do not wash it down with water. • The max. carry current of sockets is 5A. • Not applicable to the self-clinching type. ●Double-winding Latching Circuit • It is recommended to perform wiring of No.1 and No.2 of the negative (-) terminal as COM wiring, in order to improve the operation stability for Double-winding Latching. ●Using SPDT contact of the SPST-NO+SPST-NC Relay • Do not construct a circuit so that overcurrent and burning occur if the NO, NC and SPDT contacts are shortcircuited with the SPST-NO+SPST-NC Relay. Arcing may generate shortcircuiting between contacts if there is short-circuiting because of conversion to the MBB contact caused by asynchronous operation of the NO and NC contacts, the interval between the NO and NC contacts is small, or a large current is left open. ●Other precautions • This Relay is a Power Relay which is suitable for power load switching. Do not use the G6C for signal purposes such as micro load switching under 10 mA. (+) + 8 + S − 1 7 R − 2 COM Please check each region's Terms & Conditions by region website. OMRON Corporation Electronic and Mechanical Components Company Regional Contact Americas https://www.components.omron.com/ Asia-Pacific https://ecb.omron.com.sg/ Korea https://www.omron-ecb.co.kr/ Europe http://components.omron.eu/ China https://www.ecb.omron.com.cn/ Japan https://www.omron.co.jp/ecb/ © OMRON Corporation 2007-2018 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. 12 Cat. No. K018-E1-11 0318(0207)(O)
G6CU-1117P-US-DC24 价格&库存

很抱歉,暂时无法提供与“G6CU-1117P-US-DC24”相匹配的价格&库存,您可以联系我们找货

免费人工找货