G9TA
AC Power Latching Relay
60 A High power latching relay
• High power switching, Compact size
• High magnetic latching force provides vibration resistance
• Low contact resistance
• PCB terminals type available
• Conforms to UL 508 (Except PCB terminals type)
RoHS Compliant
Model Number Structure
Application Examples
• Smart Meter
• PV Inverter
G9TA- 1 A
12 3 4
2. Number of poles
1: 1-Pole
1. Relay Function
U: Single-winding latching
K: Double-winding latching
3. Contact Form
A: SPST-NO
• Lighting control
• EV Charger
G
9
T
A
4. Terminal shape
TH: M5 securing screw
TW: Welding terminals
P: PCB terminals
Ordering Information
Classification
Contact Form
Single coil
SPST-NO
Double coils
Terminal Shape
M5 securing screw
Welding terminals
PCB terminals
M5 securing screw
Welding terminals
PCB terminals
Enclosure rating
Flux protection
Model
G9TA-U1ATH
G9TA-U1ATW
G9TA-U1AP
G9TA-K1ATH
G9TA-K1ATW
G9TA-K1AP
Rated coil voltage
Minimum packing unit
12 VDC
25 pcs/tray
12 VDC
Note. When ordering, add the rated coil voltage to the model number.
Example: G9TA-U1ATH DC12
Rated coil voltage
However, the notation of the coil voltage on the product case as well as on the packing will be marked as[][] VDC.
Ratings
Coil
Single-winding Latching Type
Item
Rated Voltage
DC
Rated current (mA)
Coil resistance (Ω)
Must set voltage
(V)
12
83
145
80% max.
Rated current (mA)
Coil resistance (Ω)
Must set voltage
Set coil
217
Set coil
55
Must reset
Max. voltage
voltage
% of rated voltage
80% max.
110% max.
Set coil (W)
Reset coil (W)
Approx. 1.0
Must reset
Max. voltage
voltage
% of rated voltage
80% max.
110% max.
Set coil (W)
Approx. 2.6
Power consumption
Double-winding Latching Type
Item
Rated Voltage
DC
(V)
12
Reset coil
217
Reset coil
55
80% max.
Power consumption
Reset coil (W)
Approx. 2.6
Note 1. The rated current and coil resistance were measured at a coil temperature of 23°C with tolerances of ± 10%.
Note 2. The operating characteristics are measured at a coil temperature of 23°C.
Note 3. The maximum permissible voltage is the maximum value of the fluctuation range for the Relay coil operating power supply and was measured at an ambient
temperature of 23°C.
Contacts
Item
Contact type
Contact material
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Model
Load
G9TA-U1A /G9TA-K1A
Resistive load
Inductive load (PF=0.5)
SPST-NO
Ag Alloy
60 A at 250 VAC
60 A
250 VAC
60 A
1
G9TA
AC Power Latching Relay
Characteristics
Item
G9TA-U1A
2 mΩ max.
Set time *2
30 ms max.
20 ms max.
Reset time *2
30 ms max.
20 ms max.
Minimum pulse width
100 ms
Maximum pulse width
1,000 ms
Insulation resistance *3
Dielectric strength
Impulse withstand
voltage
Vibration resistance
Shock resistance
Durability
G
9
T
A
G9TA-K1A
Contact resistance *1
1,000 MΩ min.
Between coil and contacts
4,000 VAC, 50/60 Hz for 1 min
Between contacts of the
same polarity
1,500 VAC, 50/60 Hz for 1 min
Between coil and contacts
6 kV
Destruction
10 to 150 to 10 Hz, f < 60 Hz: Constant amplitude 0.075 mm, f > 60 Hz: Constant acceleration 9.8 m/s2
Malfunction
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Destruction
1,000 m/s2
Malfunction
100 m/s2
Mechanical
100,000 operations min. (at 7,200 operations/h)
Electrical *4
5,000 operations, resistive load and then
5,000 operations, inductive load (PF=0.5) (operation: ON for 10 sec, OFF for 20 sec) *5
Ambient operating temperature
-40 to 85°C (with no icing or condensation)
Ambient operating humidity
5 to 85%
Weight
Approx. 42 g
Note. The values given above are initial values.
*1. Measurement conditions: 24 VDC, 1 A, voltage drop method.
*2. Measurement conditions: Rated operating voltage applied, not including contact bounce.
Ambient temperature: 23°C
*3. Measurement conditions: The insulation resistance was measured with a 500 VDC megohm meter at the same locations as the dielectric strength was measured.
*4. Contact your OMRON sales representative for Electrical Durability technical data.
*5. The characteristic meets IEC62055-31 test requirement.
2
G9TA
AC Power Latching Relay
Dimensions
CAD Data
(Unit: mm)
Please visit our website, which is noted on the last page.
G9TA-U1ATH
39.1 max.
Terminal arrangement/Internal Connections
(TOP VIEW)
34.5 max.
30
1
S
R
3
2
4
4
4.95
10
5
4
9.9
5
Check carefully the coil polarity of the Relay.
6.7
10
4.65
Two, I5.5 dia.
9.3
5±0.05
7.7
Two, 0.64±0.01
18.55
14.2 18 max.
3.7
1
1
CAD Data
3.7
G
9
T
A
G9TA-U1ATW
39.1 max.
Terminal arrangement/Internal Connections
(TOP VIEW)
34.5 max.
30
1
3
2
-
S
R
4
4
8.8
Check carefully the coil polarity of the Relay.
5±0.05
7.7
Two, 0.64±0.01
18.55
12 10.6
18 max.
14.2
1
1
CAD Data
G9TA-U1AP
39.1 max.
PCB Mounting Holes
(BOTTOM VIEW)
18 max.
8.7±0.1
5±0.1
19.05±0.1
(2.8)
(3.4)
36.7 max.
30
0.6±0.1
4±0.1
Two, I1.2±0.1
4±0.1
5.5
1
8.7
19.05
1
5
4
Two, 0.64
4
Six, I2±0.1
6-1.5
Terminal arrangement/Internal Connection
(BOTTOM VIEW)
1
2
3
-
S
R
4
-
Check carefully the coil polarity of the Relay.
CAD Data
3
G9TA
AC Power Latching Relay
(Unit: mm)
G9TA-K1ATH
39.1 max.
Terminal arrangement/Internal Connections
(TOP VIEW)
34.5 max.
S
30
2
1
3
- R
4
5
4
4
6.7
Check carefully the coil polarity of the Relay.
5
10
5
10
4.65
Two, I5.5 dia.
4.95
9.3
9.9
5±0.05
7.7
5±0.05
Three, 0.64±0.01
13.55
14.2
18 max.
3.7
1
3.7
1
G G9TA-K1ATW
9
T
A
CAD Data
39.1 max.
Terminal arrangement/Internal Connections
(TOP VIEW)
34.5 max.
30
S
1
2
3
- R
5
4
4
8.8
Check carefully the coil polarity of the Relay.
5±0.05
7.7
5±0.05
Three, 0.64±0.01
13.55
12 10.6
14.2
1
18 max.
CAD Data
1
G9TA-K1AP
PCB Mounting Holes
(BOTTOM VIEW)
18 max.
39.1 max.
8.7±0.1
14.05±0.1
5±0.1 5±0.1
(2.8)
(3.4)
36.7 max.
30
0.6±0.1
4±0.1
Three, I1.2±0.1
4±0.1
5.5
8.7
1
14.05
1
5
4
5
Three, 0.64
4
Six, I2±0.1
6-1.5
Terminal arrangement/Internal Connections
(BOTTOM VIEW)
1
2
3
4
5
S - R
Check carefully the coil polarity of the Relay.
CAD Data
Note 1. Relay is delivered as "reset" status unless specified otherwise. However, the status may change due to the shock from transportation or mounting operations.
Therefore, it is recommended the relay should be set to the expected status via a power supply before being used.
Note 2. In order to maintain "set" or "reset" status, the energizing voltage to coil & the pulse width shouldn't lower then the rated value.
Note 3. Do not energize both of set and reset coil simultaneously.
Note 4. Energizing time longer than 1,000 ms should be avoided.
4
G9TA
AC Power Latching Relay
Engineering Data
Switching current (A)
Switching current (A)
Maximum Switching Capacity
G9TA-U1A
G9TA-K1A
1000
100
60
AC Resistive Load
1000
100
60
10
AC Inductive Load (PF=0.5)
10
1
1
10
100 250
1000
Switching voltage (V)
1
1
10
100 250
1000
Switching voltage (V)
Approved Standards
The approval rating values for overseas standards are different from the performance values determined individually. Confirm the values
before use.
UL Recognized:
(File No. E41515)
Model
Contact form
G9TA-U1ATH
G9TA-U1ATW
G9TA-K1ATW
G9TA-K1ATH
SPST-NO (1a)
Coil ratings
12V DC
Contact ratings
Number of test operations
60 A, 277 V AC (Resistive) 70°C
6,000
60 A, 250 V AC (Resistive) and then 60 A,
250 V (PF=0.5), 10 sec. ON / 20 sec. OFF,
40°C
5,000 for resistive and then
5,000 for PF=0.5
G
9
T
A
Safety Precautions
• Please refer to "PCB Relays Common Precautions" for correct use.
Correct Use
Installation
• The relay contacts are polarized. Incorrect wiring may cause a
failure to break the circuit. Wire the Relay with care.
• Install the Relays in locations that are as dry as possible and
have as little dust, dirt, and harmful gas.
• Using the Relay under high temperature, high humidity, or
harmful gas may deteriorate its performance characteristics
due to condensation or corrosive materials, resulting in failure
or burn damage to the Relay.
Relay Service Life
• The electrical durability of these Relays is specified as the
number of load switching operations under a resistive load and
OMRON-specified standard testing conditions.
The coil drive circuit, ambient environment, switching
frequency, or load conditions (e.g., inductive load or capacitor
load) may reduce the service life and possibly lead to failure to
break. Always confirm the service life in the actual equipment.
Wiring
•
•
•
•
•
Be sure to tighten all screws to the appropriate torque given below.
Loose screws may result in burning due to abnormal heat generation during energization.
M5 screws: 1.57 to 2.35 N·m
Use a spring washer in order to prevent deformation and looseness.
Allow suitable slack on leads when wiring, and do not apply excessive force to the terminals.
Please check each region's Terms & Conditions by region website.
OMRON Corporation
Electronic and Mechanical Components Company
Regional Contact
Americas
https://www.components.omron.com/
Asia-Pacific
https://ecb.omron.com.sg/
Korea
https://www.omron-ecb.co.kr/
Europe
http://components.omron.eu/
China
https://www.ecb.omron.com.cn/
Japan
https://www.omron.co.jp/ecb/
© OMRON Corporation 2018-2020 All Rights Reserved.
In the interest of product improvement, specifications are subject to change without notice.
Cat. No. J220-E1-03
0120(0318)
5