H7HP-AD

H7HP-AD

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    COUNTER LCD 6 CHAR 12-24V PNL MT

  • 数据手册
  • 价格&库存
H7HP-AD 数据手册
Total Counter/Time Counter (DIN 72 x 36) H7HP • Large, easy-to-read displays: 15-mm-high characters for 6-digit models; 12-mm-high characters for 8-digit models. • High-visibility, negative transmissive LCD display with built-in red LED backlight at low power consumption. • Compact (66 mm) body. • Switch 6-digit models between total counter and time counter operation. Counters 3. Supply Voltage None: 100 to 240 VAC D: 12 to 24 VDC 4. Case Color None: Light gray (Munsell 5Y7/1) B: Black 8-digit total counter Light gray H7HP-C8 H7HP-C8D Black H7HP-C8B H7HP-C8DB Compact Total Counters and Time Counters with Easy-to-read Displays and IP66G/ NEMA4 Water and Oil Resistance Model Number Structure I Model Number Legend H7HP-@@@@ 1 234 1. Classification A: Total counter/time counter C: Total counter 2. Digits None: 6 digits 8: 8 digits Ordering Information I List of Models Supply voltage 100 to 240 VAC 12 to 24 VDC H7HP-A H7HP-AD 6-digit total counter/time counter Light gray H7HP-AB H7HP-ADB Black Total Counter/Time Counter (DIN 72 x 36) H7HP C-51 Specifications I Ratings Item Rated supply voltage External power supply Operating voltage range Power consumption Dimensions Mounting method External connections Degree of protection Display Digits Function Input mode Max. counting speeds Counting range Time specification Timing accuracy Memory backup Input Input signals Input method Count, start, gate, reset 6-digit total counter/time counter H7HP-A 50 mA at 12 VDC --H7HP-AD 8-digit total counter H7HP-C8 50 mA at 12 VDC --H7HP-C8D 100 to 240 VAC (50/60 Hz) 12 to 24 VDC (see note 1) 100 to 240 VAC (50/60 Hz) 12 to 24 VDC (see note 1) 85% to 110% of rated supply voltage 100 to 240 VAC: 6.5 VA max. 12 to 24 VDC: 0.6 W max. 72 x 36 x 66 mm (W x H x D) Flush mounting Screw terminals Panel surface: IEC IP66 (JEM standard IP66G) and NEMA Type 4 (indoors) 7-segment, negative transmissive LCD (with red backlight) 6 digits (15-mm-high characters) Total counter/time counter (selected via DIP switch) Up/down (individual) (total counter), or accumulative (time counter) 30 Hz or 5 kHz (selected via DIP switch) -99999 to 999999 0.1 to 99999.9 h/1 s to 99 h 59 min 59 s ±100 ppm (-10°C to 55°C) EEP-ROM: 200,000 operations min. Count 1 (increment), count 2 (decrement), reset, and key protection (see note 2) No-voltage input (NPN transistor input) or voltage input (PNP transistor input) (selected via DIP switch) No-voltage input (NPN transistor input) Short-circuit (ON) impedance: 1 KΩ max. Short-circuit (ON) residual voltage: 2 VDC max. Open (OFF) impedance: 100 kΩ min. Voltage input (PNP transistor input) Short-circuit (ON) impedance: 1 KΩ max. ON voltage: 9 to 24 VDC OFF voltage: 5 VDC max. Open (OFF) impedance: 100 kΩ min. No-voltage input (NPN transistor input) Short-circuit (ON) impedance: 1 KΩ max. Short-circuit (ON) residual voltage: 0.5 VDC max. Open (OFF) impedance: 100 kΩ min. Time counter: 20 ms; total counter: 20 ms or 1 ms (automatically switched according to counting speed) Time counter: 20 ms Approx. 1 s External and manual resets Approx. 1 s -9999999 to 99999999 ----8 digits (12-mm-high characters) Total counter Up/down (individual) Key protection Input response speed Reset Start Key protection Reset system Note: 1. Contains 20% ripple (p-p) max. 2. Only a non-voltage input (NPN transistor) is possible for the key protection input. Switching between the NPN and PNP input methods does not affect the key protection input, i.e., a PNP input cannot be used. C-52 Total Counter/Time Counter (DIN 72 x 36) H7HP I Characteristics Insulation resistance Dielectric strength 100 MΩ min. (at 500 VDC) 2,000 VAC, 50/60 Hz for 1 min between current-carrying terminal and exposed non-current-carrying metal parts (AC model) 1,000 VAC, 50/60 Hz for 1 min between current-carrying terminal and exposed non-current-carrying metal parts (DC model) 2,000 VAC, 50/60 Hz for 1 min between power terminals and control input terminals (AC model) 1,000 VAC, 50/60 Hz for 1 min between power terminals and control input terminals (DC model) Counters Impulse withstand voltage 3 kV (between power terminals) (1 kV for 12-to-24-VDC models) 4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) (1.5 kV for 12-to-24-VDC models) Noise immunity ±1.5 kV (between AC power terminals), ±480 V (between DC power terminals), ±480 V (between input terminals); square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) Display: Malfunction: Destruction: DIP switch: Malfunction: Destruction: 8 kV 15 kV 4 kV 8 kV Static immunity Vibration resistance Shock resistance Ambient temperature Ambient humidity EMC Destruction: 10 to 55 Hz with 0.75-mm single amplitude, four cycles each in three directions (8 minutes per cycle) Malfunction: 10 to 55 Hz with 0.5-mm single amplitude, four cycles each in three directions (8 minutes per cycle) Destruction: 294 m/s2 each in three directions Malfunction: 196 m/s2 each in three directions Operating: -10°C to 55°C (with no icing) Storage: -25°C to 65°C (with no icing) Operating: 35% to 85% E61326 EN55011 Group 1 class A EN55011 Group 1 class A EN61326 EN61000-4-2: 4 kV contact discharge (level 2) 8 kV air discharge (level 3) Immunity RF-interference: EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3); 10 V/m (Pulse-modulated, 900 MHz ±5 MHz) (level 3) Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (according to EN61000-6-2) Immunity Burst: EN61000-4-4: 2 kV power-line (level 3); 2 kV I/O signal-line (level 4) Immunity Surge: EN61000-4-5: 1 kV line to lines (power and output lines) (level 2); 2 kV line to ground (power and output lines) (level 3) Immunity Voltage Dip/Interruption: EN61000-4-11: 0.5 cycle, 100% (rated voltage) UL508, CSA22.2 No.14, conforms to EN61010-1, VDE0106/P100 Rear section: Gray smoke; Front section: 5Y7/1 (light gray) or N1.5 (black) Approx. 106 g (EMI) Emission Enclosure: Emission AC Mains: (EMS) Immunity ESD: Approved standards Case color Weight Total Counter/Time Counter (DIN 72 x 36) H7HP C-53 Connections I Terminal Arrangement Note: 1. Incremented for count 1 (CP1) inputs; decremented for count 2 (CP2) inputs. 2. Non-contact input is also available. AC Models H7HP-A 100 to 240 VAC External power supply 12 VDC 50 mA max. H7HP-C8 100 to 240 VAC External power supply 12 VDC 50 mA max. Power supply Power supply Unused Unused Unused 0V 12 VDC Power supply Power supply Unused Unused Unused 0V 12 VDC 5 6 1 Key protection input 7 2 Reset input 8 3 9 4 10 11 5 6 1 Key protection input 7 2 Reset input 8 3 9 4 10 11 Count 1 Count 2 input or input or start input gate input Count 1 Count 2 input input NPN mode PNP mode NPN mode PNP mode DC Models H7HP-AD 12 to 24 VDC H7HP-C8D 12 to 24 VDC 0V Power supply Unused Unused Unused Unused Unused 0V Power supply Unused Unused Unused Unused Unused 5 6 1 Key protection input 7 2 Reset input 8 3 9 4 10 11 5 6 1 Key protection input 7 2 Reset input 8 3 9 4 10 11 Count 1 Count 2 input or input or start input gate input Count 1 Count 2 input input NPN mode PNP mode NPN mode PNP mode Operation I DIP Switch Settings Switches 1 to 4 are all set to OFF before shipping. H7HP-C8/-C8D Pin no. 1 2 Item Unused Counting speed Unused --30 Hz --OFF --5 kHz PNP --ON H7HP-A/-AD Pin no. 1 2 3 4 Item Function Counting speed Time range Unused 30 Hz 99999.9 h --OFF Total counter 5 kHz 99 h 59 min 59 s PNP --ON Time counter 3 4 Input mode (note) NPN Note: When the setting has been changed, turned power off and on to continue. The display will show “0” when the power is turned back on. Input mode (note) NPN C-54 Total Counter/Time Counter (DIN 72 x 36) H7HP I Operating Modes Total Counters Reset input AC (10-2) DC (5-2) CP1 AC (10-3) DC (5-3) CP2 AC (10-4) DC (5-4) 999999 (see note) Display 0 −99999 (see note) display Note: Display values are shown for a 6-digit model. Time Counters Reset input AC (10-2) DC (5-2) Gate input AC (10-4) DC (5-4) Start input AC (10-3) DC (5-3) 99999.9h (see note) Display 0.0 h Note: 1. Display values are shown for full scale set to 99999.9 h. 2. Gate input is available only when H7HP-A settings are made. Nomenclature 2 (The figure shows the DIP switch label stuck to the rear of the case.) 1 3 1. Reset Key Resets the count value, but will not operate while the keys are protected. 2. Key Protection Indicator Lit while the keys are protected (Reset Key is disabled.). 3. DIP Switch Use to change a setting. Refer to DIP Switch Settings for details. Total Counter/Time Counter (DIN 72 x 36) H7HP C-55 Counters Dimensions Note: All units are in millimeters unless otherwise indicated. H7HP-A H7HP-C8 M3.5 terminal screw Terminal cover (provided) Panel Cutouts Panel cutouts are as shown below (according to DIN43700). Note: 1. The mounting panel thickness should be 1 to 6 mm. 2. Water resistance will be lost if Counters are mounted side-by-side. With Flush Mounting Bracket Y92S-33 rubber packing (provided) Panel Y92F-33 flush mounting adaptor (provided) C-56 Total Counter/Time Counter (DIN 72 x 36) H7HP Connections (Common) I Input Connections Note: The undermentioned is common for all H7GP/H7HP models. No-voltage Input (NPN Input Mode) Open Collector Output H7GP/H7HP Voltage Output Sensor 12 VDC (12 to 24 VDC) Sensor (12 to 24 VDC) Reset, Count 1, Count 2, Start, and Gate Inputs Specification Short-circuit (ON) impedance: 1 kΩ max. Short-circuit (ON) residual voltage: 2 VDC max. Current flow for 0-Ω short-circuit: Approx. 2 mA Open (OFF) impedance: 100 kΩ min. Note: Two-wired sensors cannot be used. Reset input Count 1 input Count 2 input Start input Gate input 0V Reset input Count 1 input Count 2 input Start input Gate input Key Protection Input Open Collector Output H7GP/H7HP Voltage Output 12 VDC (12 to 24 VDC) (12 to 24 VDC) Sensor Key Protection Inputs Specification Short-circuit (ON) impedance: Short-circuit (ON) residual voltage: Current flow for 0-Ω short-circuit: Open (OFF) impedance: 1 kΩ max. 0.5 VDC max. Approx. 0.5 mA 100 kΩ min. Sensor Key protection input 0V Key protection input Note: Two-wired sensors cannot be used. Voltage Input (PNP Input Mode) Reset, Count 1, Count 2, Start, and Gate Inputs Sensor (12 to 24 VDC) Reset, Count 1, Count 2, Start, and Gate Inputs Specification Short-circuit (ON) impedance: 1 kΩ max. ON voltage: 9 to 24 VDC OFF voltage: 5 VDC max. Open (OFF) impedance: 100 kΩ min. Note: Two-wired sensors cannot be used. Reset input Count 1 input Count 2 input Start input Gate input Total Counter/Time Counter H7GP/H7HP C-57 Counters Reset, Count 1, Count 2, Start, and Gate Inputs Precautions (Common) Note: The undermentioned is common for all H7GP/H7HP models. Power Supplies When turning the power ON and OFF, input signal reception is possible, unstable, or impossible as shown in the diagram below. Apply the power supply voltage through a relay or switch in such a way that the voltage reaches a fixed value immediately. Power supply ON OFF Other Water resistance may deteriorate depending on the environment. Periodically check water resistance. Oil resistance is not applicable to all types of oil. Be sure to test any specific oils before actual application. Labels 200 ms 0 to 90 ms 5 ms Impossible Unstable Possible 0 to 2 s Unstable Impossible Input Unit labels are included with the H7GP/H7HP and DIP switch labels are included with the H7HP Attach these labels as shown in the fol. lowing illustrations. Although the H7GP/H7HP power supply (primary side) is isolated from control circuits (secondary side) by a transformer, the primary and secondary sides of the transformer are linked by a capacitor, making it possible for high-frequency components to leak to the secondary side. Take adequate precautions against electrical shock. Do not connect input circuits to exposed parts (such as the machine body) and be sure that the power supply is turned off before wiring. Control circuit Display circuit Unit Labels H7GP H7HP Input circuit Self-diagnostic Function The following displays will appear if an error occurs. Display ---Error -99999 max. (H7HP 6-digit model) , -99999999 max. (H7HP 8-digit model) , CPU Memory Correction Press RST Key or reset input DIP Switch Labels H7HP e1 e2 Press RST Key or turn power OFF and then ON Accessories The accessories listed in the following table are included with the H7GP/H7HP Be sure you understand the use of these accessories . and use them correctly. Name Rubber packing H7GP Y92S-32 H7HP Y92S-33 Y92F-33 Flush Mounting The panel surface is water-resistive (conforming to NEMA 4 and IP66). In order to prevent the internal circuit from water penetration through the space between the counter and operating panel, attach a rubber packing between the counter and operating panel and secure the rubber packing with the Y92F-3@ flush-mounting adaptor. Be sure the rubber packing is installed in the correct direction. The wider portion must be facing the panel when installed, as shown in the following illustration. Using a flat-head screwdriver, press in the Mounting Adapter until it cannot be pressed in any further in order to ensure water-resistive performance. Wider portion facing panel Adapter Flush mounting adap- Y92F-32 tor Panel C-58 Total Counter/Time Counter H7GP/H7HP Degree of Protection IP - 6 6 G Protection Specification Code (International Protection) (IEC529) Protection against solid foreign objects Protection against harmful ingress of water Counters Examination method 2.5 to 3 m 12.5 l/min Discharging nozzle dia.: 6.3 2.5 to 3 m 100 l/min Discharging nozzle dia.: 12.5 Japan Electrical Manufacturers Association's standards (JEM1030) Protection against oil Protection Against Solid Foreign Objects Grade 5 Protection Criteria Limited ingress of dust permitted (no harmful deposit). Dust protected 6 Dust-tight Totally protected against ingress of dust. Protection Against Harmful Ingress of Water Grade 5 Protection Criteria Housing jets from all directions Protected against low-pressure Spray water from all directions for one minute per m2 of external surjets of water from all directions; face area and for a total time of no less than 3 minutes using the test limited ingress permitted. device shown below. 6 Strong hosing jets from all directions Protected against strong jets of Spray water from all directions for one minute per m2 of external surface area and for a total time of no less than 3 minutes using the test water, e.g. for use on shipdecks; limited ingress permit- device shown below. ted. JEM Standards Protection Against Oil Grade F Oilproof Protection Criteria Criteria Protected against improper op- No penetration of oil to the extent of interfering with proper operation eration due to oil drops or spray after dropping the specified cutting oil on a test device for 48 hours at from any direction. a rate of 0.5 l per hour. Protected against penetration of oil drops or spray from any direction. No penetration of oil after dropping the specified cutting oil on a test device for 48 hours at a rate of 0.5 l per hour. G Oil resistant Total Counter/Time Counter H7GP/H7HP C-59
H7HP-AD 价格&库存

很抱歉,暂时无法提供与“H7HP-AD”相匹配的价格&库存,您可以联系我们找货

免费人工找货