2
1
THIS COPY IS PROVIDED ON A RESTRICTED BASIS AND IS NOT TO BE USED IN ANY WAY DETRIMENTAL TO THE INTERESTS OF PANDUIT CORP.
W
DIMENSIONS
PANDUIT
PART #
B
STUD SIZE
L
.04
[1,0]
W
.01
[0,3]
C
in. [mm]
.015
[0,4]
M
.03
[0,8]
H
H DIA
.01
[0,3]
PN12-6HDR
#6
1.06 [26,9]
.31 [7,9]
.35 [8,9]
.91 [23,1]
.15 [3,8]
PN12-8HDR
#8
1.06 [26,9]
.31 [7,9]
.35 [8,9]
.90 [22,9]
.17 [4,3]
PN12-10HDR
#10
1.09 [27,7]
.37 [9,4]
.33 [8,4]
.89 [22,6]
.20 [5,1]
PN12-14HDR
1/4"
1.24 [31,5]
.52 [13,2]
.42 [10,7]
.98 [24,9]
.27 [6,9]
PN12-56HDR
5/16"
1.24 [31,5]
.52 [13,2]
.42 [10,7]
.98 [24,9]
.33 [8,4]
PN12-38HDR
3/8"
1.30 [33,0]
.58 [14,7]
.46 [11,7]
1.02 [25,9]
STAMPING
C RAD
L
B
M
.39 [9,9]
SERRATED
BARREL
NOTES:
1. USED FOR:
A. #16-12 AWG [ 2,0-6,0 mm2 ] SOLID OR STRANDED COPPER WIRE
B. 221 F [105 C] MAX. OPERATING TEMPERATURE
C. 600 V. MAX. VOLTAGE RATING
1000 V. IN SIGNS, FIXTURES & LUMINARIES
2. INSTALLATION TOOLS:
A. UL APPROVED: CT-600A (CT-550CH), CT-1550,
CT-1551, CT-2500 (CT-2550CH/CD-550)
B. PANDUIT APPROVED: CT-460
HOUSING
SLEEVE
.23 [5,8]
MAX. WIRE
INSUL. DIA.
[7,1+0,8
]
3. WIRE STRIP LENGTH: 9/32" +1/32
-0
-0
4. MATERIAL:
A. STAMPING: .05" [1,3 ] THK COPPER, TIN PLATED
B. HOUSING: NYLON, YELLOW
C. SLEEVE: BRASS, TIN PLATED
5. SEE www.panduit.com FOR PACKAGE QUANTITIES
INDICATED BY PART NUMBER SUFFIX
6. DIMENSIONS IN BRACKETS ARE METRIC EQUIVALENT
LISTED
587H
E52164
CERTIFIED
LR31212
TITLE
RING TERMINALS
A
3 PC, NYLON INSULATED, HEAVY DUTY
A
#16-12
CUSTOMER DRAWING
ITEM REVISION NAME
N41283BB/07
DATASET FILE NAME
N41283BB_DC/07A
MATERIAL:
UNLESS OTHERWISE SPECIFIED,
DIMENSIONAL TOLERANCES ARE: IN [mm]
.X
D10100DA/15
.XX
04
10.16.12
JBN
LCA
VMB
REVISED NOTES.
UPDATED DRAWING TO CURRENT STANDARDS.
DATE
BY
CHK
APR
DESCRIPTION
2
.XXX
ANGLES
SEE NOTES
.005 [.13]
5
DRAWING NUMBER:
THIRD ANGLE
PROJECTION
A41283
DRAWN BY
REV
.1 [2.54]
.01 [.25]
ECN
DAW
DATE
CHK
-
A41283
SIZE
SCALE
LA
N.T.S.
1
SHT 1 OF 1
A