0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
R0605250L2

R0605250L2

  • 厂商:

    PDI

  • 封装:

  • 描述:

    R0605250L2 - Si Reverse, low current, 5 - 65 MHz, 25.0dB typ. Gain @ 65MHz, 140mA max. @ 24VDC - PRE...

  • 数据手册
  • 价格&库存
R0605250L2 数据手册
Product Specification R0605250L2 Si Reverse, low current, 5 – 65 MHz, 25.0dB typ. Gain @ 65MHz, 140mA max. @ 24VDC FEATURES • • • • • • Excellent linearity Superior return loss performance Extremely low distortion Optimal reliability Low noise Unconditionally stable under all terminations R0605250L2 APPLICATION • 5 to 65 MHz CATV SMD amplifier for reverse channel systems Si Reverse Hybrid , low current 5 – 65 MHz 25.0dB typ. Gain @ 65MHz 140mA max. @ 24VDC DESCRIPTION • Hybrid reverse SMD amplifier employing silicon dice LIMITING VALUES In accordance with the Absolute Maximum Rating System (IEC 60134) SYMBOL Vi Vov Tstg Tmb PARAMETER RF input voltage (single tone) DC supply over-voltage (5 minutes) storage temperature operating mounting base temperature MIN. - 40 - 30 MAX. 65 30 + 100 + 100 UNIT dBmV V °C °C CHARACTERISTICS Table 1: S-Parameter, Noise Figure, DC Current; VB = 24V; Tmb = 30°C; ZS = ZL = 75 Ω SYMBOL Gp SL FL S11 S22 F Itot PARAMETER power gain slope 1) flatness of frequency response input return loss output return loss noise figure total current consumption (DC) CONDITIONS f = 5 MHz f = 65 MHz f = 5 to 65 MHz f = 5 to 65 MHz f = 5 to 65 MHz f = 5 to 65 MHz f = 65 MHz MIN. 24.3 24.1 -0.2 20.0 20.0 120.0 TYP. 25.0 25.0 0.0 MAX. 25.5 0.5 ± 0.2 3.0 140.0 UNIT dB dB dB dB dB dB dB mA 2.3 130.0 Notes: 1) The slope is defined as the difference between the gain at the start frequency and the gain at the stop frequency. Page 1 of 4 2005 Aug 3 Document Revision Level D Product Specification R0605250L2 Si Reverse, low current, 5 – 65 MHz, 25.0dB typ. Gain @ 65MHz, 140mA max. @ 24VDC CHARACTERISTICS Table 2: Distortion data 5 – 65 MHz; VB = 24V; Tmb = 30°C; ZS = ZL = 75 Ω SYMBOL CTB XMOD CSO d2 STB Notes: 1) 2) 3) PARAMETER composite triple beat cross modulation composite second order distortion second order distortion third order distortion CONDITION 7 ch. flat; Vo = 50 dBmV 7 ch. flat; Vo = 50 dBmV 1) MIN. - TYP. MAX. - 68 - 58 - 68 - 70 UNIT dBc dB dBc dBc dB 7 ch. flat; Vo = 50 dBmV 1) 1) 2) 3) - - 70 7 channels, US frequency raster: T7 – T13 (7.0 to 43.0 MHz), +50 dBmV flat output level. f1 = 7 MHz; V1 = 50 dBmV; f2 = 25 MHz; V2 = 50 dBmV; fTEST = f1 + f2 = 32 MHz. f1 = 13 MHz; V1 = 50 dBmV; f2 = 25 MHz; V2 = V1; f3 = 7 MHz; V3 = V1; fTEST = f1 + f2 - f3 = 31 MHz. Composite Second Order (CSO) The CSO parameter (both sum and difference products) is defined by the NCTA. Composite Triple Beat (CTB) The CTB parameter is defined by the NCTA. Cross Modulation (XMOD) Cross modulation (XMOD) is measured at baseband (selective voltmeter method), referenced to 100% modulation of the carrier being tested. Page 2 of 4 2005 Aug 3 Document Revision Level D Product Specification R0605250L2 Si Reverse, low current, 5 – 65 MHz, 25.0dB typ. Gain @ 65MHz, 140mA max. @ 24VDC B (4x) C A (4x) D (3x) E (3x) F G I H J K L 5 4 3 All Dimensions in mm: P O Q nominal A B C D E F 2,2 ± 0,2 1,9 3,8 1,6 ± 0,2 ± 0,2 ± 0,2 M N 1 2 min 2,0 1,7 3,6 1,4 1,5 22,6 7,0 7,6 24,8 10,2 21,6 0,6 4,9 2,35 2,35 4,9 7,45 max 2,4 2,1 4,0 1,8 1,9 23,0 7,4 8,0 25,4 10,8 22,0 1,0 5,3 2,75 2,75 5,3 7,85 1,7 ± 0,2 22,8 ± 0,2 7,2 ±0,2 7,8 ± 0,2 25,1 21,8 5,1 ± 0,3 Notes: European Projection Pinning: 1 2 3 4 5 RF INPUT GND GND RF OUTPUT +VB G H I J K L M N O P Q 10,5 ± 0,3 ± 0,2 0,8 ± 0,2 ± 0,2 2,55 ± 0,2 2,55 ± 0,2 5,1 ± 0,2 7,65 ± 0,2 0 5 10mm scale Page 3 of 4 2005 Aug 3 Document Revision Level D Product Specification R0605250L2 Si Reverse, low current, 5 – 65 MHz, 25.0dB typ. Gain @ 65MHz, 140mA max. @ 24VDC DEFINITIONS Data Sheet Status Objective Product Specification Preliminary Product Specification Product Specification Limiting values Limiting values given are in accordance with the Absolute Maximum Rating System (IEC 60134). Stress above one or more of the limiting values may cause permanent damage to the device. These are stress ratings only and operation of the device at these or at any other conditions above those given in the Characteristics sections of the specification is not implied. Exposure to limiting values for extended periods may affect device reliability. Application information Where application information is given, it is advisory and does not form part of the specification. Premier Devices reserves the right to make changes without further notice to any products herein. Premier Devices makes no warranty representation or guarantee regarding the suitability of its products for any particular purpose, nor does Premier Devices assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation consequential or incidental damages. “Typical” parameters which may be provided in Premier Devices datasheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer application by customer´s technical experts. Premier Devices does not convey any license under its patent rights nor the rights of others. Premier Devices products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or other applications intended to support or sustain life, or for any other application in which the failure of the Premier Devices product could create a situation where personal injury or death may occur. Should Buyer purchase or use Premier Devices products for any such unintended or unauthorized application, Buyer shall indemnify and hold Premier Devices and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, and claim of personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that Premier Devices was negligent regarding the design or manufacture of the part. This data sheet contains target or goal specifications for product development. This data sheet contains preliminary data; supplementary data may be published later. This data sheet contains final product specifications. © Premier Devices Germany GmbH 2004 How to contact us: Premier Devices Germany GmbH Loeffelholzstrasse 20, D-90441 Nuernberg, Germany Phone: +49 (0) 911 9411 233, FAX: +49 (0) 911 9411 198, Email: sales.germany@premierdevices.com, Internet: http://www.premierdevices.de/ Page 4 of 4 2005 Aug 3 Document Revision Level D
R0605250L2 价格&库存

很抱歉,暂时无法提供与“R0605250L2”相匹配的价格&库存,您可以联系我们找货

免费人工找货