0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
1110155

1110155

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    UNO2-PS/1AC/48DC/240W

  • 数据手册
  • 价格&库存
1110155 数据手册
UNO2-PS/1AC/48DC/240W - Power supply unit 1110155 https://www.phoenixcontact.com/us/products/1110155 Please be informed that the data shown in this PDF document is generated from our online catalog. Please find the complete data in the user documentation. Our general terms of use for downloads are valid. Primary-switched power supply unit, UNO POWER, Screw connection, DIN rail mounting, input: 1-phase, output: 48 V DC / 5 A, adjustable from 42 V DC ... 56 V DC Your advantages • Save space in the control cabinet with an extremely narrow overall width of just 45 mm • Save energy, thanks to a high degree of efficiency • Outdoor installation possible, with a wide temperature range of -25°C … +70°C • Simple output voltage monitoring, thanks to the floating DC OK relay contact Commercial data Item number 1110155 Packing unit 1 pc Minimum order quantity 1 pc Sales key CM15 Product key CMPV14 GTIN 4063151024840 Weight per piece (including packing) 888 g Weight per piece (excluding packing) 855 g Customs tariff number 85044095 Country of origin TH Jan 8, 2024, 9:50 AM Page 1 (19) UNO2-PS/1AC/48DC/240W - Power supply unit 1110155 https://www.phoenixcontact.com/us/products/1110155 Technical data Input data AC operation Supply system configuration Star network (TN, TT, IT (PE)) Nominal input voltage range 100 V AC ... 240 V AC Input voltage range 100 V AC ... 240 V AC -15 % ... +10 % Derating < 90 V AC (1 %/V) Typical national grid voltage 120 V AC 230 V AC Voltage type of supply voltage AC Inrush current typ. 10 A (at 25 °C) 2 Inrush current integral (I t) < 0.05 A2s Frequency range (fN) 50 Hz ... 60 Hz ±10 % Mains buffering time typ. 20 ms (120 V AC) typ. 20 ms (230 V AC) Current consumption 2.6 A (100 V AC) 2.2 A (120 V AC) 1.16 A (230 V AC) 1.2 A (240 V AC) Protective circuit Transient surge protection; Varistor, gas-filled surge arrester Switch-on time typ. 530 ms Device mains fuse 5 A internal (device protection), fast-blow Recommended breaker for input protection 10 A ... 16 A (Characteristic B, C, D, K or comparable) Discharge current to PE < 3.5 mA Output data Efficiency typ. 91.5 % (120 V AC) typ. 93 % (230 V AC) Nominal output voltage 48 V DC Setting range of the output voltage (USet) 42 V DC ... 56 V DC (≥48 V DC, constant capacity restricted 60 V DC (on (flashing green)) Electrical properties Number of phases 1.00 Insulation voltage input/output 4 kV AC (type test) 3 kV AC (routine test) Insulation voltage input / PE 3.5 kV AC (type test) 2.4 kV AC (routine test) Product properties Product type Power supply Product family UNO POWER MTBF (IEC 61709, SN 29500) > 1000000 h (25 °C) > 550000 h (40 °C) Jan 8, 2024, 9:50 AM Page 4 (19) UNO2-PS/1AC/48DC/240W - Power supply unit 1110155 https://www.phoenixcontact.com/us/products/1110155 > 280000 h (55 °C) Environmental protection directive RoHS Directive 2011/65/EU WEEE Reach Insulation characteristics Protection class I Degree of pollution 2 Dimensions Item dimensions Width 45 mm Height 130 mm Depth 129 mm 125 mm (Device depth (DIN rail mounting)) Installation dimensions Installation distance right/left (active, passive) 0 mm / 0 mm (POut ≥50% ) Installation distance top/bottom (active, passive) 30 mm / 30 mm (POut ≥50% ) Mounting Mounting type DIN rail mounting Assembly instructions alignable: 0 mm horizontally, 30 mm vertically Mounting position horizontal DIN rail NS 35, EN 60715 With protective coating No Material specifications Flammability rating according to UL 94 V0 (Housing, terminal blocks) Housing material Metal Hood version Stainless steel Side element version Aluminum Foot latch material Sheet steel, zinc-plated Housing material Aluminum (AlMg3) / sheet steel, zinc-plated Environmental and real-life conditions Ambient conditions Degree of protection IP20 Ambient temperature (operation) -25 °C ... 70 °C (> 55 °C Derating: 2.5 %/K) Ambient temperature (storage/transport) -40 °C ... 85 °C Ambient temperature (start-up type tested) -40 °C Maximum altitude ≤ 3000 m (> 2000 m, Derating: 10 %/1000 m) Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing) Shock (operation) 18 ms, 30g, per spatial direction (IEC 60068-2-27) Vibration (operation) 10 Hz ... 50 Hz, amplitude ±0.2 mm Jan 8, 2024, 9:50 AM Page 5 (19) UNO2-PS/1AC/48DC/240W - Power supply unit 1110155 https://www.phoenixcontact.com/us/products/1110155 50 Hz to 150 Hz, 2.3 g, 90 min. Standards and regulations Overvoltage category EN 61010-1 II (≤ 3000 m) Overvoltage category EN 62477-1 III (≤3000 m)  Safety of power supply units up to 1100 V (insulation distances) Standard designation Safety of power supply units up to 1100 V (insulation distances) Standards/specifications DIN EN 61558-2-16 Electrical safety Standard designation Electrical safety Standards/specifications IEC 61010-2-201 (SELV) Electronic equipment for use in power installations Standard designation Equipping high voltage installations with electronic equipment Standards/specifications EN 50178/VDE 0160 (PELV) Safety for measurement, control, and laboratory equipment Standard designation Safety for equipment for measurement, control, and laboratory use Standards/specifications IEC 61010-1 Protective extra-low voltage Standard designation Protective extra-low voltage Standards/specifications IEC 61010-1 (SELV) IEC 61010-2-201 (PELV) Safe isolation Standard designation Safe isolation Standards/specifications IEC 61558-2-16 IEC 61010-2-201 Limitation of harmonic line currents Standard designation Limitation of harmonic line currents Standards/specifications EN 61000-3-2 Mains voltage dips Standard designation Requirement of the semiconductor industry with regard to mains voltage dips Standards/specifications SEMI F47 - 0706 (185 V AC) Approvals UL Identification UL/C-UL Listed UL 61010-1 Jan 8, 2024, 9:50 AM Page 6 (19) UNO2-PS/1AC/48DC/240W - Power supply unit 1110155 https://www.phoenixcontact.com/us/products/1110155 UL Identification UL/C-UL Listed UL 61010-2-201 UL Identification UL/C-UL Listed ANSI/UL 121201 Class I, Division 2, Groups A, B, C, D (Hazardous Location) SIQ Identification CB scheme (IEC 61010-1, IEC 61010-2-201) EMC data Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC Interference emission Interference emission in accordance with EN 61000-6-3 (residential and commercial) and EN 61000-6-4 (industrial) EMC requirements for noise immunity EN 61000-6-2 Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU Conducted noise emission EN 55016 EN 61000-6-3 (Class B) Noise emission EN 55016 EN 61000-6-3 (Class B) Harmonic currents Standards/regulations EN 61000-3-2 EN 61000-3-2 (Class A) Frequency range 0 kHz ... 2 kHz Flicker Standards/regulations EN 61000-3-3 Frequency range 0 kHz ... 2 kHz Electrostatic discharge Standards/regulations EN 61000-4-2 Electrostatic discharge Contact discharge 6 kV (Test Level 3) Discharge in air 8 kV (Test Level 3) Comments Criterion A Electromagnetic HF field Standards/regulations EN 61000-4-3 Electromagnetic HF field Frequency range 80 MHz ... 1 GHz Test field strength 10 V/m (Test Level 3) Frequency range 1 GHz ... 6 GHz Test field strength 10 V/m (Test Level 3) Comments Criterion A Jan 8, 2024, 9:50 AM Page 7 (19) UNO2-PS/1AC/48DC/240W - Power supply unit 1110155 https://www.phoenixcontact.com/us/products/1110155 Fast transients (burst) Standards/regulations EN 61000-4-4 Fast transients (burst) Input 4 kV (Test Level 4 - asymmetrical) Output 2 kV (Test Level 3 - asymmetrical) Comments Criterion A Surge voltage load (surge) Standards/regulations EN 61000-4-5 Input 2 kV (Test Level 4 - symmetrical) 4 kV (Test Level 4 - asymmetrical) Output 1 kV (Test Level 3 - symmetrical) 2 kV (Test Level 3 - asymmetrical) Comments Criterion A Conducted interference Standards/regulations EN 61000-4-6 Conducted interference Input/Output asymmetrical Frequency range 0.15 MHz ... 80 MHz Comments Criterion A Voltage 10 V (Test Level 3) Voltage dips Standards/regulations EN 61000-4-11 Voltage 230 V AC Frequency 50 Hz Voltage dip 70 % Number of periods 25 / 30 periods Comments Criterion A Voltage dip 40 % Number of periods 12 periods Additional text Test Level 2 Comments Criterion A Voltage dip 0% Number of periods 1 period Additional text Test Level 2 Comments Criterion B Criteria Criterion A Normal operating behavior within the specified limits. Criterion B Temporary impairment to operational behavior that is corrected by the device itself. Jan 8, 2024, 9:50 AM Page 8 (19) UNO2-PS/1AC/48DC/240W - Power supply unit 1110155 https://www.phoenixcontact.com/us/products/1110155 Drawings Power Factor Diagram 1,1 1,0 0,9 0,8 0,7 0,6 0,5 0,4 0,3 0    = UIn: 120 V AC/UOut : 48 V DC  = UIn: 230 V AC/UOut : 48 V DC 1 2 3 4 5 IOut [A] Power factor Jan 8, 2024, 9:50 AM Page 9 (19) UNO2-PS/1AC/48DC/240W - Power supply unit 1110155 https://www.phoenixcontact.com/us/products/1110155 Dimensional drawing UNO POWER Ord.No.1110155 45 3.1 3.2 2.1 2.2 2.3 2.4 13 + + 14 Output DC 48V 240W 42-56 V 130 DC OK Input AC 100-240V L N 1.1 1.2 1.3 Device dimensions (dimensions in mm) Jan 8, 2024, 9:50 AM Page 10 (19) UNO2-PS/1AC/48DC/240W - Power supply unit 1110155 https://www.phoenixcontact.com/us/products/1110155 Block diagram Input AC  1.1 L 1.2 N 1.3 Output DC Filter aktive PFC 2.1 Filter 2.2 + 2.3 2.4 Signal Functions UVP OVP 3.1 3.2 13 14 User Interface OTP OCP SCP UOUT DC OK Block diagram Eta [%] Diagram 96 95 94 93 92 91 90 89 88 87 86 1   2  = UIn: 120 V AC/UOut : 48 V DC  = UIn: 230 V AC/UOut : 48 V DC 3 4 5 IOut [A] Efficiency Jan 8, 2024, 9:50 AM Page 11 (19) UNO2-PS/1AC/48DC/240W - Power supply unit 1110155 https://www.phoenixcontact.com/us/products/1110155 Schematic diagram Housing Signaling PE 3.1 13 1.1 3.2 14 B Input L 1.2 N 1.3 C D A Output 2.1 2.2 2.3 2.4 + Test sections, insulation voltage Jan 8, 2024, 9:50 AM Page 12 (19) UNO2-PS/1AC/48DC/240W - Power supply unit 1110155 https://www.phoenixcontact.com/us/products/1110155 IIn [A] Diagram 2,5 2   1,5 1 0,5  = UIn: 120 V AC/UOut : 48 V DC  = UIn: 230 V AC/UOut : 48 V DC 0 0 1 2 3 4 5 IOut [A] Input current/output current Dimensional drawing 130 48 80 130 125 Device dimensions (dimensions in mm) Jan 8, 2024, 9:50 AM Page 13 (19) UNO2-PS/1AC/48DC/240W - Power supply unit 1110155 https://www.phoenixcontact.com/us/products/1110155 POut [%] Diagram 120 110 100 90 80 70 60 50 PN 100% ≤ 50°C 0 1000 2000 3000 4000 5000 H [m] Output power/installation altitude Jan 8, 2024, 9:50 AM Page 14 (19) UNO2-PS/1AC/48DC/240W - Power supply unit 1110155 https://www.phoenixcontact.com/us/products/1110155 Approvals To download certificates, visit the product detail page: https://www.phoenixcontact.com/us/products/1110155    cULus Listed Approval ID: FILE E 123528 EAC Approval ID: RU S-DE.BL08.W.00764 cULus Listed Approval ID: FILE E 199827 Jan 8, 2024, 9:50 AM Page 15 (19) UNO2-PS/1AC/48DC/240W - Power supply unit 1110155 https://www.phoenixcontact.com/us/products/1110155 Classifications ECLASS ECLASS-11.0 27040701 ECLASS-12.0 27040701 ECLASS-13.0 27040701 ETIM ETIM 9.0 EC002540 UNSPSC UNSPSC 21.0 39121000 Jan 8, 2024, 9:50 AM Page 16 (19) UNO2-PS/1AC/48DC/240W - Power supply unit 1110155 https://www.phoenixcontact.com/us/products/1110155 Environmental product compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 25; For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads” Jan 8, 2024, 9:50 AM Page 17 (19) UNO2-PS/1AC/48DC/240W - Power supply unit 1110155 https://www.phoenixcontact.com/us/products/1110155 Accessories TRIO-DIODE/48DC/2X10/1X20 - Redundancy module 2866527 https://www.phoenixcontact.com/us/products/2866527 Redundancy module with function monitoring, 48 V DC, 2x 10 A, 1x 20 A PLT-SEC-T3-230-FM-UT - Type 3 surge protection device 2907919 https://www.phoenixcontact.com/us/products/2907919 Type 2/3 surge protection, consisting of protective plug and base element with screw connection. For singlephase power supply network with integrated status indicator and remote signaling. Nominal voltage: 230 V AC/DC PLT-SEC-T3-230-FM-PT - Type 3 surge protection device 2907928 https://www.phoenixcontact.com/us/products/2907928 Type 2/3 surge protection, consisting of protective plug and base element with Push-in connection. For singlephase power supply network with integrated status indicator and remote signaling. Nominal voltage: 230 V AC/DC Jan 8, 2024, 9:50 AM Page 18 (19) UNO2-PS/1AC/48DC/240W - Power supply unit 1110155 https://www.phoenixcontact.com/us/products/1110155 Phoenix Contact 2024 © - all rights reserved https://www.phoenixcontact.com Phoenix Contact USA 586 Fulling Mill Road Middletown, PA 17057, United States (+717) 944-1300 info@phoenixcon.com Jan 8, 2024, 9:50 AM Page 19 (19)
1110155 价格&库存

很抱歉,暂时无法提供与“1110155”相匹配的价格&库存,您可以联系我们找货

免费人工找货